Zero BMS log Initial date May 20 2023 04:57:52 Pack serial number 19tb2935 Printing 7652 of 7652 log entries.. Entry Time of Log Event Conditions +--------+----------------------+--------------------------+---------------------------------- 00001 11/26/2025 15:00:09 System Turned Off 00002 11/26/2025 15:00:09 System Turned Off 00003 11/26/2025 15:00:09 System Turned Off 00004 11/26/2025 15:00:09 DEBUG: CAN Link Is Down 00005 11/26/2025 15:00:09 DEBUG: Entered Idle State 00006 11/26/2025 15:00:11 System Turned On 00007 11/26/2025 15:00:11 Rev:45,Build:2023-05-20_045619 958 banka 00008 11/26/2025 15:00:11 Pack:2019_monolith,Numbricks:4 00009 11/26/2025 15:00:11 DEBUG: Entered Running State 00010 11/26/2025 15:00:11 DEBUG: CAN NOT Receiving Syncs 00011 11/26/2025 15:00:11 DEBUG: CAN Link Is Up 00012 11/26/2025 15:00:12 DEBUG: Resetting CAN0 due to error passive mode 00013 11/26/2025 15:00:15 DEBUG: CAN Receiving Syncs 00014 11/26/2025 15:00:16 Contactor drive turned on Pack V: 101345mV, Switched V: 89403mV, Duty Cycle: 39% 00015 11/26/2025 15:00:16 Contactor was Closed Pack V: 101345mV, Switched V: 89403mV, Prechg Pct: 88%, Dischg Cur: 636mA 00016 11/26/2025 15:00:25 DEBUG: Entered Charging State 00017 11/26/2025 15:00:25 DEBUG: CAN NOT Receiving Syncs 00018 11/26/2025 15:00:26 Discharge level 061 AH, SOC: 37%, I: 0A, L:3606, l:3610, H:3623, B:017, PT:033C, BT:026C, PV:101346, M:Charge 00019 11/26/2025 15:00:27 SOC:49032,76819,61953,114800,47,43,37,7 00020 11/26/2025 15:00:27 DEBUG: CAN Receiving Syncs 00021 11/26/2025 15:10:26 Discharge level 059 AH, SOC: 45%, I:-12A, L:3648, l:3634, H:3659, B:011, PT:032C, BT:028C, PV:102374, M:Charge 00022 11/26/2025 15:10:27 SOC:37771,67656,59927,114800,48,48,45,-22 00023 11/26/2025 15:20:27 Discharge level 057 AH, SOC: 50%, I:-12A, L:3662, l:3647, H:3671, B:009, PT:032C, BT:029C, PV:102734, M:Charge 00024 11/26/2025 15:20:27 SOC:32853,64824,57856,114800,50,50,50,-23 00025 11/26/2025 15:30:27 Discharge level 055 AH, SOC: 53%, I:-12A, L:3674, l:3659, H:3682, B:008, PT:031C, BT:030C, PV:103046, M:Charge 00026 11/26/2025 15:30:27 SOC:31085,65119,55809,114800,52,51,53,-23 00027 11/26/2025 15:40:27 Discharge level 053 AH, SOC: 55%, I:-11A, L:3687, l:3672, H:3693, B:006, PT:031C, BT:030C, PV:103353, M:Charge 00028 11/26/2025 15:40:27 SOC:30350,66432,53777,114800,54,54,55,-22 00029 11/26/2025 15:50:34 Discharge level 051 AH, SOC: 57%, I:-11A, L:3699, l:3684, H:3704, B:005, PT:031C, BT:034C, PV:103661, M:Charge 00030 11/26/2025 15:50:34 SOC:29681,67786,51772,114800,55,55,57,-22 00031 11/26/2025 16:00:34 Discharge level 049 AH, SOC: 58%, I:-11A, L:3712, l:3697, H:3716, B:004, PT:030C, BT:042C, PV:103998, M:Charge 00032 11/26/2025 16:00:34 SOC:29127,69216,49804,114800,57,57,58,-22 00033 11/26/2025 16:10:34 Discharge level 047 AH, SOC: 60%, I:-12A, L:3725, l:3710, H:3729, B:004, PT:030C, BT:040C, PV:104363, M:Charge 00034 11/26/2025 16:10:34 SOC:28519,70617,47813,114800,59,59,60,-22 00035 11/26/2025 16:20:34 Discharge level 045 AH, SOC: 62%, I:-11A, L:3740, l:3725, H:3743, B:003, PT:030C, BT:042C, PV:104776, M:Charge 00036 11/26/2025 16:20:34 SOC:27943,72032,45839,114800,61,61,62,-22 00037 11/26/2025 16:30:34 Discharge level 043 AH, SOC: 63%, I:-11A, L:3755, l:3740, H:3759, B:004, PT:030C, BT:042C, PV:105194, M:Charge 00038 11/26/2025 16:30:34 SOC:27162,73235,43871,114800,62,62,63,-21 00039 11/26/2025 16:40:34 Discharge level 041 AH, SOC: 65%, I:-11A, L:3771, l:3756, H:3777, B:006, PT:030C, BT:041C, PV:105657, M:Charge 00040 11/26/2025 16:40:34 SOC:26097,74152,41905,114800,64,64,65,-22 00041 11/26/2025 16:50:34 Discharge level 039 AH, SOC: 67%, I:-11A, L:3788, l:3773, H:3795, B:007, PT:030C, BT:042C, PV:106156, M:Charge 00042 11/26/2025 16:50:34 SOC:25021,75037,39959,114800,66,66,67,-21 00043 11/26/2025 17:00:42 Discharge level 038 AH, SOC: 69%, I:-11A, L:3807, l:3792, H:3815, B:008, PT:029C, BT:041C, PV:106672, M:Charge 00044 11/26/2025 17:00:42 SOC:23823,75808,38006,114800,67,68,69,-22 00045 11/26/2025 17:10:42 Discharge level 036 AH, SOC: 71%, I:-11A, L:3827, l:3812, H:3836, B:009, PT:029C, BT:041C, PV:107234, M:Charge 00046 11/26/2025 17:10:42 SOC:22454,76379,36082,114800,69,70,71,-22 00047 11/26/2025 17:20:42 Discharge level 034 AH, SOC: 73%, I:-11A, L:3848, l:3833, H:3857, B:009, PT:029C, BT:041C, PV:107834, M:Charge 00048 11/26/2025 17:20:42 SOC:21014,76879,34157,114800,71,73,73,-21 00049 11/26/2025 17:30:42 Discharge level 032 AH, SOC: 76%, I:-11A, L:3872, l:3857, H:3880, B:008, PT:029C, BT:041C, PV:108479, M:Charge 00050 11/26/2025 17:30:42 SOC:19197,76988,32248,114800,72,75,76,-22 00051 11/26/2025 17:40:42 Discharge level 030 AH, SOC: 78%, I:-11A, L:3894, l:3879, H:3898, B:004, PT:029C, BT:042C, PV:109098, M:Charge 00052 11/26/2025 17:40:42 SOC:17522,77209,30370,114800,74,77,78,-21 00053 11/26/2025 17:50:42 Discharge level 028 AH, SOC: 80%, I:-11A, L:3917, l:3902, H:3920, B:003, PT:029C, BT:041C, PV:109722, M:Charge 00054 11/26/2025 17:50:42 SOC:15931,77486,28518,114800,76,79,80,-21 00055 11/26/2025 18:00:42 Discharge level 026 AH, SOC: 82%, I:-11A, L:3936, l:3921, H:3940, B:004, PT:029C, BT:042C, PV:110294, M:Charge 00056 11/26/2025 18:00:42 SOC:14495,77912,26672,114800,77,81,82,-21 00057 11/26/2025 18:10:50 Discharge level 024 AH, SOC: 84%, I:-11A, L:3956, l:3941, H:3960, B:004, PT:029C, BT:044C, PV:110835, M:Charge 00058 11/26/2025 18:10:50 SOC:13177,78462,24822,114800,79,83,84,-21 00059 11/26/2025 18:20:50 Discharge level 022 AH, SOC: 86%, I:-10A, L:3975, l:3961, H:3978, B:003, PT:028C, BT:043C, PV:111356, M:Charge 00060 11/26/2025 18:20:50 SOC:11842,78967,22999,114800,80,85,86,-20 00061 11/26/2025 18:30:50 Discharge level 021 AH, SOC: 87%, I:-10A, L:3994, l:3980, H:3997, B:003, PT:028C, BT:040C, PV:111874, M:Charge 00062 11/26/2025 18:30:50 SOC:10679,79620,21202,114800,82,86,87,-20 00063 11/26/2025 18:40:50 Discharge level 019 AH, SOC: 89%, I:-11A, L:4014, l:4000, H:4016, B:002, PT:028C, BT:036C, PV:112410, M:Charge 00064 11/26/2025 18:40:50 SOC:9316,80065,19412,114800,84,88,89,-20 00065 11/26/2025 18:47:17 Charged To Full 018 AH, SOC: 90%, L:4025, H:4028, B:003, PT:028C, BT:035C, PV:112741 00066 11/26/2025 18:47:17 SOC adjusted for voltage old: 8509377uAH (soc:90%), new: 8041579uAH (soc:90%), low cell: 4025 mV 00067 11/26/2025 18:50:50 Discharge level 010 AH, SOC: 91%, I:-10A, L:4031, l:4018, H:4034, B:003, PT:028C, BT:033C, PV:112920, M:Charge 00068 11/26/2025 18:50:50 SOC:7768,80781,10847,114800,91,90,91,-19 00069 11/26/2025 19:00:50 Discharge level 009 AH, SOC: 92%, I:-10A, L:4051, l:4038, H:4053, B:002, PT:028C, BT:032C, PV:113451, M:Charge 00070 11/26/2025 19:00:50 SOC:6638,81443,9074,114800,93,92,92,-20 00071 11/26/2025 19:10:50 Discharge level 007 AH, SOC: 94%, I:-10A, L:4070, l:4057, H:4073, B:003, PT:027C, BT:031C, PV:113992, M:Charge 00072 11/26/2025 19:10:50 SOC:5254,81836,7314,114800,94,94,94,-19 00073 11/26/2025 19:20:50 Discharge level 005 AH, SOC: 96%, I:-10A, L:4088, l:4075, H:4091, B:003, PT:027C, BT:031C, PV:114512, M:Charge 00074 11/26/2025 19:20:50 SOC:3737,82079,5572,114800,96,95,96,-19 00075 11/26/2025 20:08:50 DEBUG: CAN Link Is Down 00076 11/26/2025 20:08:54 Contactor was Opened Pack V: 116107mV, Switched V: 116145mV, Prechg Pct: 100%, Dischg Cur: 545mA 00077 11/26/2025 20:08:54 DEBUG: CAN Link Is Up 00078 11/26/2025 20:08:56 System Turned Off 00079 11/26/2025 20:08:57 DEBUG: CAN Link Is Down 00080 11/26/2025 20:08:57 DEBUG: Entered Idle State 00081 11/26/2025 20:09:03 Current Sensor Zeroed old: 2504mV, new: 2505mV, corrfact: 251 00082 11/26/2025 20:09:04 Discharge level 000 AH, SOC:100%, I: 0A, L:4149, l:4147, H:4152, B:003, PT:026C, BT:036C, PV:116201, M:Idle 00083 11/26/2025 20:09:04 SOC:0,82684,0,114800,100,100,100,-4 00084 11/26/2025 20:09:24 Voltage Across Contactor: 103333mV (Okay) 00085 11/26/2025 22:10:15 System Turned On 00086 11/26/2025 22:10:15 Rev:45,Build:2023-05-20_045619 958 banka 00087 11/26/2025 22:10:15 Pack:2019_monolith,Numbricks:4 00088 11/26/2025 22:10:15 DEBUG: Entered Charging State 00089 11/26/2025 22:10:15 DEBUG: CAN NOT Receiving Syncs 00090 11/26/2025 22:10:15 DEBUG: Entered Running State 00091 11/26/2025 22:10:15 DEBUG: CAN Link Is Up 00092 11/26/2025 22:10:16 DEBUG: Resetting CAN0 due to error passive mode 00093 11/26/2025 22:10:16 Discharge level 000 AH, SOC:100%, I: 0A, L:4129, l:4127, H:4132, B:003, PT:024C, BT:039C, PV:115666, M:Bike On 00094 11/26/2025 22:10:16 SOC:0,82684,0,114800,100,100,100,-3 00095 11/26/2025 22:10:19 DEBUG: CAN Receiving Syncs 00096 11/26/2025 22:10:24 Contactor drive turned on Pack V: 115658mV, Switched V: 101691mV, Duty Cycle: 34% 00097 11/26/2025 22:10:24 Contactor was Closed Pack V: 115658mV, Switched V: 101691mV, Prechg Pct: 88%, Dischg Cur: 454mA 00098 11/26/2025 22:11:16 Discharge level 000 AH, SOC:100%, I: 0A, L:4128, l:4128, H:4131, B:003, PT:024C, BT:036C, PV:115648, M:Bike On 00099 11/26/2025 22:11:16 SOC:0,82684,0,114800,100,100,100,0 00100 11/26/2025 22:12:16 Discharge level 000 AH, SOC:100%, I: 0A, L:4127, l:4127, H:4131, B:004, PT:024C, BT:035C, PV:115639, M:Bike On 00101 11/26/2025 22:12:16 SOC:3,82683,4,114800,100,100,100,0 00102 11/26/2025 22:13:16 Discharge level 000 AH, SOC:100%, I: 27A, L:4090, l:4104, H:4100, B:010, PT:024C, BT:034C, PV:114693, M:Bike On 00103 11/26/2025 22:13:16 SOC:65,82595,68,114800,100,98,100,20 00104 11/26/2025 22:14:16 Discharge level 000 AH, SOC:100%, I: -2A, L:4127, l:4128, H:4130, B:003, PT:024C, BT:032C, PV:115615, M:Bike On 00105 11/26/2025 22:14:16 SOC:244,82280,263,114800,100,100,100,1 00106 11/26/2025 22:15:16 Discharge level 000 AH, SOC:100%, I: 48A, L:4030, l:4065, H:4051, B:021, PT:024C, BT:032C, PV:113214, M:Bike On 00107 11/26/2025 22:15:16 SOC:396,81970,433,114800,100,94,100,46 00108 11/26/2025 22:16:16 Discharge level 000 AH, SOC:100%, I: 1A, L:4101, l:4113, H:4108, B:007, PT:024C, BT:031C, PV:114965, M:Bike On 00109 11/26/2025 22:16:16 SOC:706,81330,791,114800,100,99,100,16 00110 11/26/2025 22:17:16 Discharge level 001 AH, SOC: 99%, I:-19A, L:4088, l:4114, H:4097, B:009, PT:024C, BT:030C, PV:114631, M:Bike On 00111 11/26/2025 22:17:16 SOC:1434,80276,1543,114800,99,99,99,35 00112 11/26/2025 22:18:16 Discharge level 002 AH, SOC: 97%, I:106A, L:3853, l:3985, H:3902, B:049, PT:024C, BT:030C, PV:108732, M:Bike On 00113 11/26/2025 22:18:16 SOC:2753,78639,2898,114800,98,87,97,176 00114 11/26/2025 22:19:16 Discharge level 003 AH, SOC: 96%, I: 32A, L:3982, l:4047, H:4006, B:024, PT:024C, BT:029C, PV:111931, M:Bike On 00115 11/26/2025 22:19:16 SOC:3750,77383,3892,114800,97,93,96,87 00116 11/26/2025 22:20:16 Discharge level 004 AH, SOC: 95%, I: 1A, L:3981, l:4033, H:4007, B:026, PT:025C, BT:029C, PV:111957, M:Bike On 00117 11/26/2025 22:20:16 SOC:4528,76227,4705,114800,96,91,95,70 00118 11/26/2025 22:21:16 Discharge level 006 AH, SOC: 92%, I:113A, L:3796, l:3947, H:3853, B:057, PT:025C, BT:027C, PV:107317, M:Bike On 00119 11/26/2025 22:21:16 SOC:6412,74216,6590,114800,95,83,92,197 00120 11/26/2025 22:22:16 Discharge level 008 AH, SOC: 90%, I: 96A, L:3809, l:3941, H:3863, B:054, PT:025C, BT:027C, PV:107654, M:Bike On 00121 11/26/2025 22:22:16 SOC:7970,72729,8148,114800,93,82,90,171 00122 11/26/2025 22:23:16 Discharge level 010 AH, SOC: 87%, I:107A, L:3756, l:3905, H:3819, B:063, PT:026C, BT:026C, PV:106357, M:Bike On 00123 11/26/2025 22:23:16 SOC:9880,71121,10059,114800,92,79,87,197 00124 11/26/2025 22:24:16 Discharge level 011 AH, SOC: 84%, I: 90A, L:3765, l:3897, H:3826, B:061, PT:026C, BT:026C, PV:106609, M:Bike On 00125 11/26/2025 22:24:16 SOC:11384,70067,11564,114800,90,78,84,173 00126 11/26/2025 22:25:16 Discharge level 012 AH, SOC: 82%, I: 86A, L:3769, l:3888, H:3827, B:058, PT:026C, BT:026C, PV:106681, M:Bike On 00127 11/26/2025 22:25:16 SOC:12685,69381,12868,114800,89,78,82,155 00128 11/26/2025 22:26:16 Discharge level 014 AH, SOC: 80%, I: 77A, L:3777, l:3889, H:3831, B:054, PT:027C, BT:025C, PV:106812, M:Bike On 00129 11/26/2025 22:26:16 SOC:13904,68895,14096,114800,88,77,80,144 00130 11/26/2025 22:27:16 Discharge level 015 AH, SOC: 78%, I: 86A, L:3730, l:3863, H:3793, B:063, PT:027C, BT:026C, PV:105690, M:Bike On 00131 11/26/2025 22:27:16 SOC:15478,68277,15673,114800,87,75,78,170 00132 11/26/2025 22:28:16 Discharge level 017 AH, SOC: 76%, I: 0A, L:3830, l:3913, H:3862, B:032, PT:027C, BT:026C, PV:107914, M:Bike On 00133 11/26/2025 22:28:16 SOC:16939,67761,17197,114800,86,80,76,106 00134 11/26/2025 22:29:16 Discharge level 017 AH, SOC: 75%, I:-15A, L:3886, l:3922, H:3906, B:020, PT:027C, BT:026C, PV:109231, M:Bike On 00135 11/26/2025 22:29:16 SOC:17018,67761,17553,114800,85,81,75,47 00136 11/26/2025 22:30:16 Discharge level 018 AH, SOC: 75%, I: 87A, L:3749, l:3838, H:3804, B:055, PT:028C, BT:025C, PV:106099, M:Bike On 00137 11/26/2025 22:30:16 SOC:17359,67757,18112,114800,85,72,75,116 00138 11/26/2025 22:31:16 Discharge level 018 AH, SOC: 74%, I: 78A, L:3760, l:3855, H:3808, B:048, PT:028C, BT:025C, PV:106286, M:Bike On 00139 11/26/2025 22:31:16 SOC:17896,67733,18813,114800,84,74,74,124 00140 11/26/2025 22:32:16 Discharge level 019 AH, SOC: 73%, I:154A, L:3685, l:3797, H:3751, B:066, PT:028C, BT:025C, PV:104490, M:Bike On 00141 11/26/2025 22:32:17 SOC:18389,67705,19506,114800,84,68,73,147 00142 11/26/2025 22:33:16 Discharge level 019 AH, SOC: 73%, I: 56A, L:3784, l:3845, H:3827, B:043, PT:028C, BT:025C, PV:106843, M:Bike On 00143 11/26/2025 22:33:17 SOC:18621,67922,19913,114800,83,73,73,79 00144 11/26/2025 22:34:16 Discharge level 020 AH, SOC: 72%, I:-18A, L:3864, l:3889, H:3879, B:015, PT:028C, BT:024C, PV:108504, M:Bike On 00145 11/26/2025 22:34:17 SOC:19349,67767,20818,114800,82,78,72,33 00146 11/26/2025 22:35:17 Discharge level 021 AH, SOC: 72%, I: 26A, L:3825, l:3863, H:3852, B:027, PT:028C, BT:025C, PV:107658, M:Bike On 00147 11/26/2025 22:35:17 SOC:19475,68099,21107,114800,82,75,72,49 00148 11/26/2025 22:36:17 Discharge level 021 AH, SOC: 72%, I:171A, L:3625, l:3741, H:3711, B:086, PT:028C, BT:024C, PV:103258, M:Bike On 00149 11/26/2025 22:36:17 SOC:19761,68639,21442,114800,82,61,72,152 00150 11/26/2025 22:37:17 Discharge level 021 AH, SOC: 72%, I: 1A, L:3862, l:3873, H:3880, B:018, PT:028C, BT:025C, PV:108508, M:Bike On 00151 11/26/2025 22:37:17 SOC:19621,69101,21491,114800,82,76,72,14 00152 11/26/2025 22:38:17 Discharge level 021 AH, SOC: 72%, I: 31A, L:3808, l:3846, H:3838, B:030, PT:028C, BT:025C, PV:107230, M:Bike On 00153 11/26/2025 22:38:17 SOC:20004,69570,21914,114800,81,ri 00154 11/26/2025 22:42:17 SOC:21228,70221,23705,114800,80,71,70,56 00155 11/26/2025 22:43:17 Discharge level 025 AH, SOC: 68%, I:154A, L:3581, l:3724, H:3663, B:082, PT:028C, BT:025C, PV:101937, M:Bike On 00156 11/26/2025 22:43:17 SOC:22592,69773,25075,114800,79,59,68,189 00157 11/26/2025 22:44:17 Discharge level 026 AH, SOC: 65%, I: 96A, L:3617, l:3746, H:3682, B:065, PT:028C, BT:023C, PV:102618, M:Bike On 00158 11/26/2025 22:44:17 SOC:24337,68986,26830,114800,77,62,65,170 00159 11/26/2025 22:45:17 Discharge level 028 AH, SOC: 63%, I: 1A, L:3740, l:3795, H:3768, B:028, PT:029C, BT:024C, PV:105305, M:Bike On 00160 11/26/2025 22:45:17 SOC:25533,68778,28045,114800,76,68,63,73 00161 11/26/2025 22:46:17 Discharge level 028 AH, SOC: 64%, I: 1A, L:3769, l:3796, H:3789, B:020, PT:029C, BT:025C, PV:105956, M:Bike On 00162 11/26/2025 22:46:17 SOC:25617,69302,28259,114800,76,68,64,36 00163 11/26/2025 22:47:17 Discharge level 028 AH, SOC: 64%, I: 1A, L:3780, l:3799, H:3796, B:016, PT:029C, BT:025C, PV:106174, M:Bike On 00164 11/26/2025 22:47:17 SOC:25621,69936,28412,114800,76,69,64,25 00165 11/26/2025 22:47:35 Contactor was Opened Pack V: 106251mV, Switched V: 106220mV, Prechg Pct: 100%, Dischg Cur: 1273mA 00166 11/26/2025 22:47:36 System Turned Off 00167 11/26/2025 22:47:36 System Turned Off 00168 11/26/2025 22:47:36 System Turned Off 00169 11/26/2025 22:47:36 DEBUG: CAN Link Is Down 00170 11/26/2025 22:47:37 DEBUG: Entered Idle State 00171 11/26/2025 22:47:42 Current Sensor Zeroed old: 2505mV, new: 2506mV, corrfact: 250 00172 11/26/2025 22:47:44 Discharge level 028 AH, SOC: 64%, I: 0A, L:3787, l:3802, H:3801, B:014, PT:028C, BT:025C, PV:106314, M:Idle 00173 11/26/2025 22:47:44 SOC:25627,70275,28422,114800,76,69,64,20 00174 11/26/2025 22:48:05 Voltage Across Contactor: 92838mV (Okay) 00175 11/26/2025 22:48:43 System Turned On 00176 11/26/2025 22:48:43 Rev:45,Build:2023-05-20_045619 958 banka 00177 11/26/2025 22:48:43 Pack:2019_monolith,Numbricks:4 00178 11/26/2025 22:48:43 DEBUG: Entered Running State 00179 11/26/2025 22:48:43 DEBUG: CAN NOT Receiving Syncs 00180 11/26/2025 22:48:43 DEBUG: CAN Link Is Up 00181 11/26/2025 22:48:44 DEBUG: Resetting CAN0 due to error passive mode 00182 11/26/2025 22:48:44 Discharge level 028 AH, SOC: 64%, I: 0A, L:3792, l:3807, H:3806, B:014, PT:028C, BT:025C, PV:106454, M:Bike On 00183 11/26/2025 22:48:44 SOC:25622,70275,28422,114800,76,70,64,20 00184 11/26/2025 22:48:47 DEBUG: CAN Receiving Syncs 00185 11/26/2025 22:48:48 Contactor drive turned on Pack V: 106452mV, Switched V: 93341mV, Duty Cycle: 37% 00186 11/26/2025 22:48:48 Contactor was Closed Pack V: 106452mV, Switched V: 93341mV, Prechg Pct: 88%, Dischg Cur: 909mA 00187 11/26/2025 22:49:02 DEBUG: Entered Charging State 00188 11/26/2025 22:49:02 DEBUG: CAN NOT Receiving Syncs 00189 11/26/2025 22:49:03 Discharge level 028 AH, SOC: 64%, I: 1A, L:3794, l:3807, H:3807, B:013, PT:028C, BT:025C, PV:106477, M:Charge 00190 11/26/2025 22:49:03 SOC:25609,70596,28428,114800,76,70,64,18 00191 11/26/2025 22:49:04 DEBUG: CAN Receiving Syncs 00192 11/26/2025 22:59:03 Discharge level 026 AH, SOC: 73%, I:-10A, L:3865, l:3850, H:3872, B:007, PT:028C, BT:032C, PV:108317, M:Charge 00193 11/26/2025 22:59:03 SOC:17638,64535,26576,114800,77,74,73,-20 00194 11/26/2025 23:09:03 Discharge level 024 AH, SOC: 78%, I:-10A, L:3896, l:3880, H:3902, B:006, PT:028C, BT:036C, PV:109181, M:Charge 00195 11/26/2025 23:09:03 SOC:14523,63282,24731,114800,79,77,78,-20 00196 11/26/2025 23:19:03 Discharge level 022 AH, SOC: 80%, I:-10A, L:3920, l:3904, H:3927, B:007, PT:027C, BT:037C, PV:109893, M:Charge 00197 11/26/2025 23:19:03 SOC:12852,63470,22888,114800,81,80,80,-20 00198 11/26/2025 23:29:11 Discharge level 021 AH, SOC: 83%, I:-11A, L:3944, l:3928, H:3949, B:005, PT:027C, BT:039C, PV:110530, M:Charge 00199 11/26/2025 23:29:11 SOC:11514,63994,21044,114800,82,82,83,-20 00200 11/26/2025 23:39:11 Discharge level 019 AH, SOC: 84%, I:-10A, L:3965, l:3949, H:3970, B:005, PT:026C, BT:039C, PV:111116, M:Charge 00201 11/26/2025 23:39:11 SOC:10395,64703,19234,114800,84,84,84,-20 00202 11/26/2025 23:49:11 Discharge level 017 AH, SOC: 86%, I:-10A, L:3986, l:3971, H:3989, B:003, PT:026C, BT:038C, PV:111669, M:Charge 00203 11/26/2025 23:49:11 SOC:9283,65403,17442,114800,85,85,86,-20 00204 11/26/2025 23:59:11 Discharge level 015 AH, SOC: 88%, I:-10A, L:4006, l:3991, H:4009, B:003, PT:025C, BT:034C, PV:112234, M:Charge 00205 11/26/2025 23:59:11 SOC:8165,66074,15671,114800,87,87,88,-19 00206 11/27/2025 00:08:32 Charged To Full 014 AH, SOC: 90%, L:4025, H:4028, B:003, PT:025C, BT:033C, PV:112747 00207 11/27/2025 00:08:32 SOC adjusted for voltage old: 7025195uAH (soc:90%), new: 6659319uAH (soc:90%), low cell: 4025 mV 00208 11/27/2025 00:09:11 Discharge level 011 AH, SOC: 91%, I:-10A, L:4026, l:4011, H:4028, B:002, PT:025C, BT:033C, PV:112775, M:Charge 00209 11/27/2025 00:09:11 SOC:6662,66710,11366,114800,91,89,91,-20 00210 11/27/2025 00:19:11 Discharge level 009 AH, SOC: 92%, I:-10A, L:4046, l:4031, H:4049, B:003, PT:025C, BT:032C, PV:113327, M:Charge 00211 11/27/2025 00:19:11 SOC:5750,67554,9629,114800,92,91,92,-19 00212 11/27/2025 00:29:11 Discharge level 007 AH, SOC: 94%, I:-10A, L:4065, l:4050, H:4068, B:003, PT:024C, BT:031C, PV:113874, M:Charge 00213 11/27/2025 00:29:11 SOC:4552,68098,7906,114800,94,93,94,-19 00214 11/27/2025 00:39:11 Discharge level 006 AH, SOC: 96%, I:-10A, L:4085, l:4070, H:4089, B:004, PT:024C, BT:030C, PV:114428, M:Charge 00215 11/27/2025 00:39:11 SOC:3327,68595,6203,114800,95,95,96,-19 00216 11/27/2025 01:25:50 DEBUG: CAN Link Is Down 00217 11/27/2025 01:25:54 Contactor was Opened Pack V: 116171mV, Switched V: 116066mV, Prechg Pct: 100%, Dischg Cur: 363mA 00218 11/27/2025 01:25:54 DEBUG: CAN Link Is Up 00219 11/27/2025 01:25:56 System Turned Off 00220 11/27/2025 01:25:57 DEBUG: CAN Link Is Down 00221 11/27/2025 01:25:57 DEBUG: Entered Idle State 00222 11/27/2025 01:26:03 Current Sensor Zeroed old: 2506mV, new: 2507mV, corrfact: 249 00223 11/27/2025 01:26:04 Discharge level 000 AH, SOC:100%, I: 0A, L:4147, l:4144, H:4149, B:002, PT:024C, BT:031C, PV:116143, M:Idle 00224 11/27/2025 01:26:04 SOC:0,69716,0,114800,100,100,100,-4 00225 11/27/2025 01:26:24 Voltage Across Contactor: 103234mV (Okay) 00226 11/27/2025 08:07:10 System Turned On 00227 11/27/2025 08:07:10 Rev:45,Build:2023-05-20_045619 958 banka 00228 11/27/2025 08:07:10 Pack:2019_monolith,Numbricks:4 00229 11/27/2025 08:07:10 DEBUG: Entered Charging State 00230 11/27/2025 08:07:10 DEBUG: CAN NOT Receiving Syncs 00231 11/27/2025 08:07:10 DEBUG: Entered Running State 00232 11/27/2025 08:07:10 DEBUG: CAN Link Is Up 00233 11/27/2025 08:07:11 DEBUG: Resetting CAN0 due to error passive mode 00234 11/27/2025 08:07:11 Discharge level 000 AH, SOC:100%, I: 0A, L:4120, l:4117, H:4123, B:003, PT:018C, BT:038C, PV:115431, M:Bike On 00235 11/27/2025 08:07:11 SOC:1,69716,0,114800,100,99,100,-3 00236 11/27/2025 08:07:14 DEBUG: CAN Receiving Syncs 00237 11/27/2025 08:07:14 Contactor drive turned on Pack V: 115399mV, Switched V: 100903mV, Duty Cycle: 34% 00238 11/27/2025 08:07:14 Contactor was Closed Pack V: 115399mV, Switched V: 100903mV, Prechg Pct: 87%, Dischg Cur: 818mA 00239 11/27/2025 08:08:11 Discharge level 000 AH, SOC:100%, I: 1A, L:4118, l:4118, H:4122, B:004, PT:018C, BT:034C, PV:115386, M:Bike On 00240 11/27/2025 08:08:11 SOC:26,69554,16,114800,100,99,100,0 00241 11/27/2025 08:09:11 Discharge level 000 AH, SOC:100%, I: 1A, L:4118, l:4118, H:4122, B:004, PT:018C, BT:031C, PV:115377, M:Bike On 00242 11/27/2025 08:09:11 SOC:46,69378,34,114800,100,99,100,0 00243 11/27/2025 08:10:11 Discharge level 000 AH, SOC:100%, I: 1A, L:4118, l:4118, H:4121, B:003, PT:018C, BT:031C, PV:115352, M:Bike On 00244 11/27/2025 08:10:11 SOC:65,69206,53,114800,100,99,100,0 00245 11/27/2025 08:11:11 Discharge level 000 AH, SOC:100%, I: 1A, L:4095, l:4101, H:4102, B:007, PT:018C, BT:028C, PV:114769, M:Bike On 00246 11/27/2025 08:11:11 SOC:165,68953,142,114800,100,98,100,7 00247 11/27/2025 08:12:11 Discharge level 000 AH, SOC:100%, I: 0A, L:4111, l:4118, H:4114, B:003, PT:018C, BT:028C, PV:115161, M:Bike On 00248 11/27/2025 08:12:11 SOC:338,68578,307,114800,100,99,100,7 00249 11/27/2025 08:13:11 Discharge level 000 AH, SOC:100%, I: 28A, L:4023, l:4056, H:4037, B:014, PT:018C, BT:026C, PV:112846, M:Bike On 00250 11/27/2025 08:13:11 SOC:536,68191,499,114800,100,93,100,34 00251 11/27/2025 08:14:11 Discharge level 001 AH, SOC: 98%, I: 43A, L:3974, l:4041, H:3994, B:020, PT:018C, BT:026C, PV:111574, M:Bike On 00252 11/27/2025 08:14:11 SOC:1400,66773,1350,114800,99,92,98,69 00253 11/27/2025 08:15:11 Discharge level 002 AH, SOC: 97%, I: 49A, L:3940, l:4008, H:3963, B:023, PT:018C, BT:027C, PV:110670, M:Bike On 00254 11/27/2025 08:15:11 SOC:2215,65435,2184,114800,99,89,97,70 00255 11/27/2025 08:16:11 Discharge level 002 AH, SOC: 96%, I: 45A, L:3952, l:4031, H:3977, B:025, PT:018C, BT:026C, PV:111042, M:Bike On 00256 11/27/2025 08:16:11 SOC:2838,64362,2875,114800,98,91,96,81 00257 11/27/2025 08:17:11 Discharge level 003 AH, SOC: 95%, I: 0A, L:4028, l:4060, H:4040, B:012, PT:019C, BT:025C, PV:112987, M:Bike On 00258 11/27/2025 08:17:11 SOC:3486,63524,3549,114800,97,94,95,33 00259 11/27/2025 08:18:11 Discharge level 003 AH, SOC: 95%, I:126A, L:3892, l:3997, H:3925, B:033, PT:019C, BT:026C, PV:109478, M:Bike On 00260 11/27/2025 08:18:11 SOC:3740,63105,3804,114800,97,87,95,108 00261 11/27/2025 08:19:11 Discharge level 004 AH, SOC: 94%, I:128A, L:3844, l:3943, H:3884, B:040, PT:019C, BT:026C, PV:108254, M:Bike On 00262 11/27/2025 08:19:11 SOC:4126,62553,4213,114800,97,83,94,107 00263 11/27/2025 08:20:11 Discharge level 005 AH, SOC: 92%, I: 2A, L:3882, l:3946, H:3911, B:029, PT:020C, BT:024C, PV:109164, M:Bike On 00264 11/27/2025 08:20:11 SOC:5111,61460,5239,114800,96,83,92,69 00265 11/27/2025 08:21:11 Discharge level 005 AH, SOC: 91%, I: 47A, L:3910, l:3987, H:3936, B:026, PT:020C, BT:025C, PV:109908, M:Bike On 00266 11/27/2025 08:21:11 SOC:5646,60867,5813,114800,95,87,91,82 00267 11/27/2025 08:22:11 Discharge level 007 AH, SOC: 89%, I: 1A, L:3954, l:4031, H:3969, B:015, PT:020C, BT:025C, PV:110994, M:Bike On 00268 11/27/2025 08:22:11 SOC:6830,59834,7020,114800,94,90,89,81 00269 11/27/2025 08:23:11 Discharge level 007 AH, SOC: 88%, I: 0A, L:3956, l:4008, H:3971, B:015, PT:021C, BT:025C, PV:111057, M:Bike On 00270 11/27/2025 08:23:11 SOC:7517,59191,7810,114800,94,89,88,59 00271 11/27/2025 08:24:11 Discharge level 008 AH, SOC: 86%, I: 1A, L:3951, l:4005, H:3966, B:015, PT:021C, BT:024C, PV:110906, M:Bike On 00272 11/27/2025 08:24:11 SOC:8287,58546,8658,114800,93,88,86,60 00273 11/27/2025 08:25:11 Discharge level 009 AH, SOC: 85%, I:439A, L:3429, l:3752, H:3544, B:115, PT:022C, BT:025C, PV: 97918, M:Bike On 00274 11/27/2025 08:25:11 SOC:9234,58033,9616,114800,92,61,85,360 00275 11/27/2025 08:26:11 Discharge level 011 AH, SOC: 81%, I: 60A, L:3790, l:3907, H:3828, B:038, PT:022C, BT:023C, PV:106783, M:Bike On 00276 11/27/2025 08:26:11 SOC:11238,57052,11627,114800,90,79,81,139 00277 11/27/2025 08:27:11 Discharge level 012 AH, SOC: 78%, I:140A, L:3693, l:3847, H:3748, B:055, PT:023C, BT:025C, PV:104384, M:Bike On 00278 11/27/2025 08:27:11 SOC:12523,56779,12917,114800,89,73,78,182 00279 11/27/2025 08:28:11 Discharge level 014 AH, SOC: 76%, I: 60A, L:3774, l:3881, H:3815, B:041, PT:023C, BT:023C, PV:106428, M:Bike On 00280 11/27/2025 08:28:11 SOC:13699,56779,14096,114800,88,77,76,126 00281 11/27/2025 08:29:11 Discharge level 015 AH, SOC: 74%, I: 67A, L:3751, l:3864, H:3794, B:043, PT:023C, BT:023C, PV:105829, M:Bike On 00282 11/27/2025 08:29:11 SOC:14900,56891,15301,114800,87,75,74,136 00283 11/27/2025 08:30:11 Discharge level 016 AH, SOC: 72%, I: 86A, L:3708, l:3835, H:3757, B:049, PT:024C, BT:024C, PV:104731, M:Bike On 00284 11/27/2025 08:30:11 SOC:16205,57062,16614,114800,86,72,72,152 00285 11/27/2025 08:31:11 Discharge level 018 AH, SOC: 68%, I:382A, L:3371, l:3686, H:3491, B:120, PT:024C, BT:024C, PV: 96562, M:Bike On 00286 11/27/2025 08:31:11 SOC:18436,56899,18856,114800,84,54,68,377 00287 11/27/2025 08:32:11 Discharge level 021 AH, SOC: 64%, I:480A, L:3225, l:3603, H:3368, B:143, PT:025C, BT:024C, PV: 92905, M:Bike On 00288 11/27/2025 08:32:11 SOC:20850,56742,21289,114800,82,39,64,469 00289 11/27/2025 08:32:11 Discharge cutback 82% 00290 11/27/2025 08:32:12 709A 00291 11/27/2025 08:33:11 Discharge level 023 AH, SOC: 60%, I:198A, L:3459, l:3685, H:3552, B:093, PT:026C, BT:024C, PV: 98614, M:Bike On 00292 11/27/2025 08:33:11 SOC:22886,57166,23341,114800,80,54,60,293 00293 11/27/2025 08:34:11 Discharge level 025 AH, SOC: 56%, I:262A, L:3387, l:3655, H:3494, B:107, PT:027C, BT:024C, PV: 96864, M:Bike On 00294 11/27/2025 08:34:11 SOC:25295,57485,25765,114800,78,47,56,354 00295 11/27/2025 08:34:12 Discharge cutback 80% 00296 11/27/2025 08:34:12 692A 00297 11/27/2025 08:35:11 Discharge level 028 AH, SOC: 52%, I:171A, L:3481, l:3686, H:3564, B:083, PT:028C, BT:024C, PV: 99099, M:Bike On 00298 11/27/2025 08:35:11 SOC:27869,57837,28351,114800,76,53,52,286 00299 11/27/2025 08:35:12 Discharge cutback 76% 00300 11/27/2025 08:35:12 651A 00301 11/27/2025 08:36:11 Discharge level 030 AH, SOC: 50%, I:125A, L:3539, l:3695, H:3608, B:069, PT:028C, BT:024C, PV:100472, M:Bike On 00302 11/27/2025 08:36:11 SOC:29522,58906,30035,114800,74,56,50,228 00303 11/27/2025 08:36:12 Discharge cutback 85% 00304 11/27/2025 08:36:12 729A 00305 11/27/2025 08:37:11 Discharge level 032 AH, SOC: 47%, I: 32A, L:3604, l:3717, H:3651, B:047, PT:029C, BT:024C, PV:101899, M:Bike On 00306 11/27/2025 08:37:11 SOC:31591,59319,32198,114800,72,58,47,168 00307 11/27/2025 08:37:12 Discharge cutback 64% 00308 11/27/2025 08:37:12 550A 00309 11/27/2025 08:38:11 Discharge level 033 AH, SOC: 46%, I: 4A, L:3671, l:3729, H:3700, B:029, PT:030C, BT:024C, PV:103422, M:Bike On 00310 11/27/2025 08:38:12 SOC:32559,60143,33455,114800,71,60,46,89 00311 11/27/2025 08:38:12 Discharge cutback 87% 00312 11/27/2025 08:38:12 746A 00313 11/27/2025 08:39:11 Discharge level 033 AH, SOC: 48%, I: 0A, L:3706, l:3737, H:3727, B:021, PT:030C, BT:025C, PV:104249, M:Bike On 00314 11/27/2025 08:39:12 SOC:32257,61648,33527,114800,71,62,48,48 00315 11/27/2025 08:40:12 Discharge level 033 AH, SOC: 50%, I: 0A, L:3719, l:3739, H:3736, B:017, PT:030C, BT:024C, PV:104508, M:Bike On 00316 11/27/2025 08:40:12 SOC:31751,62278,33628,114800,71,62,50,33 00317 11/27/2025 08:41:12 Discharge level 036 AH, SOC: 46%, I:131A, L:3509, l:3643, H:3573, B:064, PT:031C, BT:025C, PV: 99560, M:Bike On 00318 11/27/2025 08:41:12 SOC:33972,61776,36049,114800,69,47,46,216 00319 11/27/2025 08:41:12 Discharge cutback 67% 00320 11/27/2025 08:41:12 574A 00321 11/27/2025 08:42:12 Discharge level 037 AH, SOC: 43%, I:-25A, L:3647, l:3709, H:3672, B:025, PT:031C, BT:024C, PV:102666, M:Bike On 00322 11/27/2025 08:42:12 SOC:35428,61347,37870,114800,68,58,43,100 00323 11/27/2025 08:42:12 Discharge cutback 64% 00324 11/27/2025 08:42:12 550A 00325 11/27/2025 08:43:12 Discharge level 038 AH, SOC: 44%, I: 0A, L:3666, l:3696, H:3688, B:022, PT:031C, BT:025C, PV:103150, M:Bike On 00326 11/27/2025 08:43:12 SOC:3505531,61976,38263,114800,67,58,48, 00327 11/27/2025 08:47:05 Contactor was Opened Pack V: 103872mV, Switched V: 103817mV, Prechg Pct: 100%, Dischg Cur: 545mA 00328 11/27/2025 08:47:05 System Turned Off 00329 11/27/2025 08:47:06 DEBUG: CAN Link Is Down 00330 11/27/2025 08:47:06 DEBUG: Entered Idle State 00331 11/27/2025 08:47:12 Current Sensor Zeroed old: 2507mV, new: 2504mV, corrfact: 252 00332 11/27/2025 08:47:13 Current Sensor Zeroed old: 2504mV, new: 2504mV, corrfact: 252 00333 11/27/2025 08:47:14 Discharge level 038 AH, SOC: 49%, I: 0A, L:3700, l:3707, H:3714, B:014, PT:031C, BT:026C, PV:103897, M:Idle 00334 11/27/2025 08:47:14 SOC:32176,62035,38268,114800,67,58,49,11 00335 11/27/2025 08:47:35 Voltage Across Contactor: 90809mV (Okay) 00336 11/27/2025 09:29:23 System Turned On 00337 11/27/2025 09:29:23 Rev:45,Build:2023-05-20_045619 958 banka 00338 11/27/2025 09:29:23 Pack:2019_monolith,Numbricks:4 00339 11/27/2025 09:29:23 DEBUG: Entered Running State 00340 11/27/2025 09:29:23 DEBUG: CAN NOT Receiving Syncs 00341 11/27/2025 09:29:24 DEBUG: CAN Link Is Up 00342 11/27/2025 09:29:24 DEBUG: Resetting CAN0 due to error passive mode 00343 11/27/2025 09:29:24 Discharge level 038 AH, SOC: 49%, I: 0A, L:3726, l:3733, H:3731, B:005, PT:029C, BT:029C, PV:104387, M:Bike On 00344 11/27/2025 09:29:24 SOC:32167,62035,38268,114800,67,61,49,12 00345 11/27/2025 09:29:28 DEBUG: CAN Receiving Syncs 00346 11/27/2025 09:29:32 Contactor drive turned on Pack V: 104381mV, Switched V: 92002mV, Duty Cycle: 38% 00347 11/27/2025 09:29:32 Contactor was Closed Pack V: 104381mV, Switched V: 92002mV, Prechg Pct: 88%, Dischg Cur: 636mA 00348 11/27/2025 09:30:24 Discharge level 038 AH, SOC: 50%, I: 0A, L:3707, l:3722, H:3715, B:008, PT:029C, BT:029C, PV:103935, M:Bike On 00349 11/27/2025 09:30:25 SOC:31835,62851,38370,114800,67,60,50,24 00350 11/27/2025 09:31:25 Discharge level 038 AH, SOC: 51%, I: 19A, L:3694, l:3713, H:3703, B:009, PT:029C, BT:029C, PV:103610, M:Bike On 00351 11/27/2025 09:31:25 SOC:31480,63060,38676,114800,67,59,51,30 00352 11/27/2025 09:32:25 Discharge level 038 AH, SOC: 52%, I: 32A, L:3685, l:3706, H:3697, B:012, PT:029C, BT:029C, PV:103410, M:Bike On 00353 11/27/2025 09:32:25 SOC:30972,63456,38719,114800,67,58,52,33 00354 11/27/2025 09:33:25 Discharge level 038 AH, SOC: 52%, I: 0A, L:3710, l:3720, H:3716, B:006, PT:029C, BT:029C, PV:103998, M:Bike On 00355 11/27/2025 09:33:25 SOC:30810,64110,38875,114800,67,60,52,16 00356 11/27/2025 09:34:25 Discharge level 038 AH, SOC: 53%, I:-16A, L:3728, l:3728, H:3732, B:004, PT:029C, BT:029C, PV:104445, M:Bike On 00357 11/27/2025 09:34:25 SOC:30546,64561,38976,114800,67,61,53,1 00358 11/27/2025 09:35:25 Discharge level 039 AH, SOC: 54%, I: 40A, L:3670, l:3696, H:3685, B:015, PT:029C, BT:029C, PV:103047, M:Bike On 00359 11/27/2025 09:35:25 SOC:30351,65087,39058,114800,66,56,54,39 00360 11/27/2025 09:36:25 Discharge level 039 AH, SOC: 54%, I: 21A, L:3688, l:3703, H:3699, B:011, PT:029C, BT:029C, PV:103481, M:Bike On 00361 11/27/2025 09:36:25 SOC:30300,65471,39239,114800,66,57,54,22 00362 11/27/2025 09:37:25 Discharge level 039 AH, SOC: 54%, I: 1A, L:3698, l:3708, H:3706, B:008, PT:029C, BT:029C, PV:103690, M:Bike On 00363 11/27/2025 09:37:25 SOC:30530,65478,39705,114800,66,58,54,16 00364 11/27/2025 09:38:25 Discharge level 039 AH, SOC: 54%, I: 28A, L:3666, l:3690, H:3680, B:014, PT:029C, BT:028C, PV:102927, M:Bike On 00365 11/27/2025 09:38:25 SOC:30534,65501,39979,114800,66,56,54,37 00366 11/27/2025 09:39:25 Discharge level 040 AH, SOC: 54%, I: 1A, L:3693, l:3705, H:3702, B:009, PT:029C, BT:028C, PV:103564, M:Bike On 00367 11/27/2025 09:39:25 SOC:30651,65945,40178,114800,66,58,54,17 00368 11/27/2025 09:40:25 Discharge level 040 AH, SOC: 54%, I: 1A, L:3697, l:3704, H:3705, B:008, PT:029C, BT:027C, PV:103658, M:Bike On 00369 11/27/2025 09:40:25 SOC:30724,66535,40282,114800,65,58,54,11 00370 11/27/2025 09:40:27 Contactor was Opened Pack V: 103664mV, Switched V: 103620mV, Prechg Pct: 100%, Dischg Cur: 1182mA 00371 11/27/2025 09:40:28 System Turned Off 00372 11/27/2025 09:40:29 DEBUG: CAN Link Is Down 00373 11/27/2025 09:40:29 DEBUG: Entered Idle State 00374 11/27/2025 09:40:35 Current Sensor Zeroed old: 2504mV, new: 2507mV, corrfact: 249 00375 11/27/2025 09:40:36 Discharge level 040 AH, SOC: 54%, I: 0A, L:3698, l:3704, H:3705, B:007, PT:029C, BT:028C, PV:103697, M:Idle 00376 11/27/2025 09:40:36 SOC:30718,66570,40283,114800,65,58,54,9 00377 11/27/2025 09:40:57 Voltage Across Contactor: 90743mV (Okay) 00378 11/27/2025 11:07:47 System Turned On 00379 11/27/2025 11:07:47 Rev:45,Build:2023-05-20_045619 958 banka 00380 11/27/2025 11:07:47 Pack:2019_monolith,Numbricks:4 00381 11/27/2025 11:07:47 DEBUG: Entered Running State 00382 11/27/2025 11:07:47 DEBUG: CAN NOT Receiving Syncs 00383 11/27/2025 11:07:48 DEBUG: CAN Link Is Up 00384 11/27/2025 11:07:48 DEBUG: Resetting CAN0 due to error passive mode 00385 11/27/2025 11:07:48 Discharge level 040 AH, SOC: 54%, I: 0A, L:3713, l:3720, H:3718, B:005, PT:025C, BT:025C, PV:104030, M:Bike On 00386 11/27/2025 11:07:48 SOC:30714,66570,40283,114800,65,60,54,9 00387 11/27/2025 11:07:51 DEBUG: CAN Receiving Syncs 00388 11/27/2025 11:07:52 Contactor drive turned on Pack V: 104023mV, Switched V: 91017mV, Duty Cycle: 38% 00389 11/27/2025 11:07:52 Contactor was Closed Pack V: 104023mV, Switched V: 91017mV, Prechg Pct: 87%, Dischg Cur: 545mA 00390 11/27/2025 11:08:48 Discharge level 040 AH, SOC: 55%, I: 0A, L:3712, l:3716, H:3717, B:005, PT:025C, BT:025C, PV:104010, M:Bike On 00391 11/27/2025 11:08:48 SOC:30344,66575,40283,114800,65,59,55,6 00392 11/27/2025 11:09:48 Discharge level 040 AH, SOC: 55%, I: 0A, L:3711, l:3716, H:3715, B:004, PT:025C, BT:025C, PV:103978, M:Bike On 00393 11/27/2025 11:09:48 SOC:30101,66620,40318,114800,65,59,55,6 00394 11/27/2025 11:10:48 Discharge level 040 AH, SOC: 55%, I: 18A, L:3682, l:3699, H:3690, B:008, PT:024C, BT:025C, PV:103239, M:Bike On 00395 11/27/2025 11:10:48 SOC:30011,66596,40477,114800,65,57,55,22 00396 11/27/2025 11:11:48 Discharge level 040 AH, SOC: 55%, I: 1A, L:3697, l:3708, H:3703, B:006, PT:024C, BT:025C, PV:103620, M:Bike On 00397 11/27/2025 11:11:48 SOC:30042,66587,40697,114800,65,58,55,14 00398 11/27/2025 11:12:48 Discharge level 040 AH, SOC: 55%, I: 1A, L:3695, l:3704, H:3700, B:005, PT:024C, BT:025C, PV:103552, M:Bike On 00399 11/27/2025 11:12:48 SOC:30124,66526,40939,114800,65,58,55,12 00400 11/27/2025 11:13:48 Discharge level 041 AH, SOC: 55%, I: 0A, L:3697, l:3703, H:3702, B:005, PT:024C, BT:024C, PV:103615, M:Bike On 00401 11/27/2025 11:13:48 SOC:30028,66573,41003,114800,65,58,55,8 00402 11/27/2025 11:14:48 Discharge level 041 AH, SOC: 56%, I: 0A, L:3698, l:3702, H:3704, B:006, PT:024C, BT:025C, PV:103650, M:Bike On 00403 11/27/2025 11:14:48 SOC:29878,66606,41015,114800,65,57,56,6 00404 11/27/2025 11:15:48 Discharge level 041 AH, SOC: 56%, I: 0A, L:3701, l:3703, H:3706, B:005, PT:024C, BT:025C, PV:103710, M:Bike On 00405 11/27/2025 11:15:49 SOC:29724,66625,41027,114800,65,58,56,3 00406 11/27/2025 11:16:48 Discharge level 041 AH, SOC: 56%, I: 0A, L:3701, l:3704, H:3705, B:004, PT:024C, BT:023C, PV:103694, M:Bike On 00407 11/27/2025 11:16:49 SOC:29580,66598,41053,114800,65,58,56,4 00408 11/27/2025 11:17:49 Discharge level 041 AH, SOC: 56%, I: 0A, L:3702, l:3704, H:3706, B:004, PT:024C, BT:025C, PV:103720, M:Bike On 00409 11/27/2025 11:17:49 SOC:29434,66604,41055,114800,65,58,56,2 00410 11/27/2025 11:18:49 Discharge level 041 AH, SOC: 56%, I:-12A, L:3710, l:3713, H:3715, B:005, PT:024C, BT:025C, PV:103943, M:Bike On 00411 11/27/2025 11:18:49 SOC:29440,66521,41176,114800,65,59,56,5 00412 11/27/2025 11:19:49 Discharge level 041 AH, SOC: 55%, I: 72A, L:3575, l:3646, H:3602, B:027, PT:024C, BT:024C, PV:100599, M:Bike On 00413 11/27/2025 11:19:49 SOC:30074,65967,41865,114800,64,49,55,87 00414 11/27/2025 11:19:49 Discharge cutback 87% 00415 11/27/2025 11:19:49 749A 00416 11/27/2025 11:20:49 Discharge level 042 AH, SOC: 54%, I: 0A, L:3663, l:3691, H:3672, B:009, PT:024C, BT:024C, PV:102752, M:Bike On 00417 11/27/2025 11:20:49 SOC:30479,65433,42389,114800,64,56,54,35 00418 11/27/2025 11:20:49 Discharge cutback 86% 00419 11/27/2025 11:20:49 739A 00420 11/27/2025 11:21:49 Discharge level 042 AH, SOC: 53%, I: 0A, L:3666, l:3683, H:3675, B:009, PT:024C, BT:023C, PV:102837, M:Bike On 00421 11/27/2025 11:21:49 SOC:30678,65027,42743,114800,63,55,53,21 00422 11/27/2025 11:21:49 Discharge cutback 89% 00423 11/27/2025 11:21:49 769A 00424 11/27/2025 11:22:49 Discharge level 042 AH, SOC: 54%, I: 0A, L:3676, l:3684, H:3684, B:008, PT:024C, BT:024C, PV:103088, M:Bike On 00425 11/27/2025 11:22:49 SOC:30550,65031,42748,114800,63,55,54,10 00426 11/27/2025 11:23:22 DEBUG: Entered Charging State 00427 11/27/2025 11:23:22 DEBUG: CAN NOT Receiving Syncs 00428 11/27/2025 11:23:23 Discharge level 042 AH, SOC: 54%, I: 0A, L:3679, l:3685, H:3687, B:008, PT:024C, BT:024C, PV:103168, M:Charge 00429 11/27/2025 11:23:23 SOC:30480,65031,42748,114800,63,55,54,7 00430 11/27/2025 11:23:23 DEBUG: CAN Receiving Syncs 00431 11/27/2025 11:33:23 Discharge level 040 AH, SOC: 60%, I:-12A, L:3736, l:3718, H:3744, B:008, PT:023C, BT:035C, PV:104728, M:Charge 00432 11/27/2025 11:33:23 SOC:25421,62042,40705,114800,65,60,60,-22 00433 11/27/2025 11:43:23 Discharge level 038 AH, SOC: 63%, I:-11A, L:3756, l:3738, H:3766, B:010, PT:023C, BT:037C, PV:105314, M:Charge 00434 11/27/2025 11:43:23 SOC:23235,61890,38688,114800,67,62,63,-22 00435 11/27/2025 11:53:23 Discharge level 036 AH, SOC: 66%, I:-12A, L:3776, l:3758, H:3786, B:010, PT:023C, BT:037C, PV:105868, M:Charge 00436 11/27/2025 11:53:23 SOC:21828,62479,36709,114800,69,65,66,-22 00437 11/27/2025 12:03:31 Discharge level 034 AH, SOC: 68%, I:-11A, L:3797, l:3779, H:3808, B:011, PT:023C, BT:037C, PV:106436, M:Charge 00438 11/27/2025 12:03:31 SOC:20592,63281,34689,114800,70,67,68,-22 00439 11/27/2025 12:13:31 Discharge level 032 AH, SOC: 70%, I:-12A, L:3816, l:3797, H:3829, B:013, PT:023C, BT:038C, PV:107002, M:Charge 00440 11/27/2025 12:13:31 SOC:19480,64144,32732,114800,72,69,70,-22 00441 11/27/2025 12:23:31 Discharge level 030 AH, SOC: 72%, I:-11A, L:3838, l:3820, H:3850, B:012, PT:023C, BT:036C, PV:107596, M:Charge 00442 11/27/2025 12:23:31 SOC:18339,64974,30778,114800,74,71,72,-21 00443 11/27/2025 12:33:31 Discharge level 028 AH, SOC: 74%, I:-11A, L:3861, l:3844, H:3873, B:012, PT:024C, BT:037C, PV:108245, M:Charge 00444 11/27/2025 12:33:31 SOC:17147,65731,28847,114800,75,74,74,-21 00445 11/27/2025 12:43:31 Discharge level 026 AH, SOC: 77%, I:-10A, L:3885, l:3868, H:3893, B:008, PT:024C, BT:038C, PV:108878, M:Charge 00446 11/27/2025 12:43:31 SOC:15658,66148,26960,114800,77,76,77,-20 00447 11/27/2025 12:53:31 Discharge level 025 AH, SOC: 79%, I:-11A, L:3908, l:3891, H:3913, B:005, PT:024C, BT:039C, PV:109502, M:Charge 00448 11/27/2025 12:53:31 SOC:14286,66675,25080,114800,79,78,79,-21 00449 11/27/2025 13:03:31 Discharge level 023 AH, SOC: 81%, I:-11A, L:3930, l:3913, H:3934, B:004, PT:024C, BT:041C, PV:110102, M:Charge 00450 11/27/2025 13:03:31 SOC:12998,67286,23201,114800,80,80,81,-21 00451 11/27/2025 13:13:39 Discharge level 021 AH, SOC: 83%, I:-11A, L:3950, l:3933, H:3954, B:004, PT:024C, BT:039C, PV:110674, M:Charge 00452 11/27/2025 13:13:39 SOC:11863,68053,21316,114800,82,82,83,-21 00453 11/27/2025 13:23:39 Discharge level 019 AH, SOC: 85%, I:-11A, L:3969, l:3952, H:3973, B:004, PT:023C, BT:038C, PV:111198, M:Charge 00454 11/27/2025 13:23:39 SOC:10782,68876,19432,114800,84,84,85,-21 00455 11/27/2025 13:33:39 Discharge level 017 AH, SOC: 87%, I:-11A, L:3988, l:3971, H:3992, B:004, PT:023C, BT:036C, PV:111730, M:Charge 00456 11/27/2025 13:33:39 SOC:9716,69692,17569,114800,85,86,87,-21 00457 11/27/2025 13:43:39 Discharge level 015 AH, SOC: 88%, I:-11A, L:4008, l:3991, H:4011, B:003, PT:023C, BT:032C, PV:112261, M:Charge 00458 11/27/2025 13:43:39 SOC:8652,70520,15696,114800,87,87,88,-21 00459 11/27/2025 13:52:21 Charged To Full 014 AH, SOC: 90%, L:4025, H:4027, B:002, PT:023C, BT:030C, PV:112736 00460 11/27/2025 13:52:21 SOC adjusted for voltage old: 7600191uAH (soc:90%), new: 7112133uAH (soc:90%), low cell: 4025 mV 00461 11/27/2025 13:53:39 Discharge level 011 AH, SOC: 91%, I:-11A, L:4028, l:4012, H:4030, B:002, PT:023C, BT:030C, PV:112806, M:Charge 00462 11/27/2025 13:53:39 SOC:7118,71373,11236,114800,91,89,91,-21 00463 11/27/2025 14:03:39 Discharge level 009 AH, SOC: 92%, I:-11A, L:4046, l:4030, H:4048, B:002, PT:023C, BT:029C, PV:113327, M:Charge 00464 11/27/2025 14:03:39 SOC:6216,72334,9392,114800,92,91,92,-21 00465 11/27/2025 14:13:39 Discharge level 007 AH, SOC: 94%, I:-10A, L:4065, l:4050, H:4067, B:002, PT:023C, BT:029C, PV:113840, M:Charge 00466 11/27/2025 14:13:39 SOC:5040,72990,7579,114800,94,93,94,-20 00467 11/27/2025 14:23:39 Discharge level 005 AH, SOC: 95%, I:-10A, L:4083, l:4068, H:4086, B:003, PT:023C, BT:030C, PV:114382, M:Charge 00468 11/27/2025 14:23:39 SOC:3832,73596,5786,114800,95,95,95,-20 00469 11/27/2025 15:11:59 DEBUG: CAN Link Is Down 00470 11/27/2025 15:12:03 Contactor was Opened Pack V: 116158mV, Switched V: 116027mV, Prechg Pct: 100%, Dischg Cur: 90mA 00471 11/27/2025 15:12:03 DEBUG: CAN Link Is Up 00472 11/27/2025 15:12:05 System Turned Off 00473 11/27/2025 15:12:06 DEBUG: CAN Link Is Down 00474 11/27/2025 15:12:06 DEBUG: Entered Idle State 00475 11/27/2025 15:12:12 Current Sensor Zeroed old: 2507mV, new: 2504mV, corrfact: 252 00476 11/27/2025 15:12:13 Discharge level 000 AH, SOC:100%, I: 0A, L:4146, l:4143, H:4149, B:003, PT:023C, BT:033C, PV:115960, M:Idle 00477 11/27/2025 15:12:13 SOC:0,74718,0,114800,100,100,100,-5 00478 11/27/2025 15:12:33 Voltage Across Contactor: 103252mV (Okay) 00479 11/27/2025 21:57:23 System Turned On 00480 11/27/2025 21:57:23 Rev:45,Build:2023-05-20_045619 958 banka 00481 11/27/2025 21:57:23 Pack:2019_monolith,Numbricks:4 00482 11/27/2025 21:57:23 DEBUG: Entered Charging State 00483 11/27/2025 21:57:23 DEBUG: CAN NOT Receiving Syncs 00484 11/27/2025 21:57:23 DEBUG: Entered Running State 00485 11/27/2025 21:57:24 DEBUG: CAN Link Is Up 00486 11/27/2025 21:57:24 DEBUG: Resetting CAN0 due to error passive mode 00487 11/27/2025 21:57:25 Discharge level 000 AH, SOC:100%, I: 0A, L:4118, l:4114, H:4120, B:002, PT:018C, BT:032C, PV:115348, M:Bike On 00488 11/27/2025 21:57:25 SOC:1,74718,0,114800,100,99,100,-4 00489 11/27/2025 21:57:27 DEBUG: CAN Receiving Syncs 00490 11/27/2025 21:57:32 Contactor drive turned on Pack V: 115331mV, Switched V: 101415mV, Duty Cycle: 34% 00491 11/27/2025 21:57:32 Contactor was Closed Pack V: 115331mV, Switched V: 101415mV, Prechg Pct: 88%, Dischg Cur: 545mA 00492 11/27/2025 21:58:25 Discharge level 000 AH, SOC:100%, I: 0A, L:4116, l:4115, H:4120, B:004, PT:018C, BT:031C, PV:115320, M:Bike On 00493 11/27/2025 21:58:25 SOC:70,74717,0,114800,100,99,100,-1 00494 11/27/2025 21:59:25 Discharge level 000 AH, SOC:100%, I: 1A, L:4110, l:4110, H:4114, B:004, PT:018C, BT:030C, PV:115146, M:Bike On 00495 11/27/2025 21:59:25 SOC:132,74694,5,114800,100,99,100,0 00496 11/27/2025 22:00:25 Discharge level 000 AH, SOC:100%, I: 1A, L:4104, l:4112, H:4108, B:004, PT:018C, BT:029C, PV:114983, M:Bike On 00497 11/27/2025 22:00:25 SOC:261,74482,96,114800,100,99,100,8 00498 11/27/2025 22:01:25 Discharge level 000 AH, SOC:100%, I: 23A, L:4067, l:4088, H:4077, B:010, PT:018C, BT:027C, PV:114055, M:Bike On 00499 11/27/2025 22:01:25 SOC:501,73809,363,114800,100,96,100,22 00500 11/27/2025 22:02:25 Discharge level 000 AH, SOC: 64%, I: 0A, L:3967, l:0, H:3989, B:022, PT:018C, BT:027C, PV: 7, M:None 00501 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00502 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00503 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00504 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00505 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00506 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00507 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00508 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00509 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00510 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00511 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00512 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00513 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00514 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00515 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00516 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00517 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00518 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00519 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00520 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00521 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00522 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00523 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00524 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00525 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00526 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00527 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00528 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00529 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00530 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00531 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00532 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00533 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00534 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00535 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00536 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00537 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00538 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00539 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00540 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00541 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00542 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00543 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00544 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00545 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00546 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00547 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00548 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00549 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00550 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00551 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00552 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00553 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00554 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00555 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00556 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00557 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00558 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00559 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00560 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00561 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00562 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00563 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00564 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00565 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00566 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00567 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00568 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00569 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00570 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00571 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00572 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00573 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00574 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00575 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00576 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00577 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00578 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00579 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00580 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00581 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00582 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00583 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00584 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00585 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00586 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00587 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00588 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00589 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00590 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00591 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00592 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00593 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00594 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00595 11/27/2025 22:02:25 SOC:722,73157,607,114800,100,90,100,56 00596 11/27/2025 22:03:25 Discharge level 000 AH, SOC: 99%, I: -5A, L:4112, l:4118, H:4116, B:004, PT:018C, BT:026C, PV:115184, M:Bike On 00597 11/27/2025 22:03:25 Discharge level 000 AH, SOC: 99%, I: -5A, L:4112, l:4118, H:4116, B:004, PT:018C, BT:026C, PV:115184, M:Bike On 00598 11/27/2025 22:03:25 SOC:895,72564,807,114800,100,99,99,6 00599 11/27/2025 22:04:25 Discharge level 001 AH, SOC: 98%, I: 2A, L:4069, l:4095, H:4076, B:007, PT:018C, BT:025C, PV:114058, M:Bike On 00600 11/27/2025 22:04:25 SOC:1443,71521,1361,114800,99,97,98,27 00601 11/27/2025 22:05:25 Discharge level 002 AH, SOC: 97%, I: 52A, L:3909, l:4006, H:3937, B:028, PT:018C, BT:025C, PV:109890, M:Bike On 00602 11/27/2025 22:05:25 SOC:2589,69885,2527,114800,98,89,97,100 00603 11/27/2025 22:06:25 Discharge level 004 AH, SOC: 93%, I: 71A, L:3862, l:4029, H:3895, B:033, PT:019C, BT:024C, PV:108690, M:Bike On 00604 11/27/2025 22:06:25 SOC:4867,67199,4804,114800,96,90,93,170 00605 11/27/2025 22:07:25 Discharge level 006 AH, SOC: 90%, I: 1A, L:3867, l:4005, H:3896, B:029, PT:020C, BT:023C, PV:108798, M:Bike On 00606 11/27/2025 22:07:25 SOC:6824,65195,6759,114800,95,89,90,147 00607 11/27/2025 22:08:25 Discharge level 008 AH, SOC: 87%, I:114A, L:3702, l:3889, H:3760, B:058, PT:020C, BT:023C, PV:104671, M:Bike On 00608 11/27/2025 22:08:25 SOC:8629,63586,8565,114800,93,77,87,196 00609 11/27/2025 22:09:25 Discharge level 010 AH, SOC: 84%, I: 96A, L:3718, l:3891, H:3774, B:056, PT:021C, BT:023C, PV:105141, M:Bike On 00610 11/27/2025 22:09:25 SOC:10559,62163,10498,114800,91,77,84,192 00611 11/27/2025 22:10:25 Discharge level 013 AH, SOC: 78%, I:188A, L:3524, l:3813, H:3616, B:092, PT:023C, BT:021C, PV:100396, M:Bike On 00612 11/27/2025 22:10:25 SOC:13671,60179,13626,114800,89,67,78,316 00613 11/27/2025 22:10:25 Discharge cutback 86% 00614 11/27/2025 22:10:25 742A 00615 11/27/2025 22:11:25 Discharge level 015 AH, SOC: 74%, I: 79A, L:3666, l:3849, H:3729, B:063, PT:024C, BT:021C, PV:103903, M:Bike On 00616 11/27/2025 22:11:25 SOC:15918,59454,15878,114800,87,73,74,213 00617 11/27/2025 22:12:25 Discharge level 018 AH, SOC: 69%, I: 71A, L:3694, l:3874, H:3747, B:053, PT:025C, BT:021C, PV:104521, M:Bike On 00618 11/27/2025 22:12:25 SOC:18306,59018,18273,114800,85,76,69,216 00619 11/27/2025 22:13:25 Discharge level 019 AH, SOC: 67%, I:101A, L:3650, l:3809, H:3715, B:065, PT:026C, BT:022C, PV:103538, M:Bike On 00620 11/27/2025 22:13:25 SOC:19731,59332,19744,114800,83,69,67,196 00621 11/27/2025 22:14:25 Discharge level 021 AH, SOC: 65%, I: 75A, L:3679, l:3811, H:3736, B:057, PT:026C, BT:022C, PV:104190, M:Bike On 00622 11/27/2025 22:14:25 SOC:21019,59909,21062,114800,82,69,65,164 00623 11/27/2025 22:15:25 Discharge level 022 AH, SOC: 63%, I:104A, L:3632, l:3774, H:3698, B:066, PT:027C, BT:022C, PV:103053, M:Bike On 00624 11/27/2025 22:15:25 SOC:22594,60335,22682,114800,81,65,63,183 00625 11/27/2025 22:16:25 Discharge level 023 AH, SOC: 62%, I: 1A, L:3756, l:3835, H:3785, B:029, PT:027C, BT:021C, PV:105796, M:Bike On 00626 11/27/2025 22:16:25 SOC:23457,60681,23786,114800,80,72,62,102 00627 11/27/2025 22:17:25 Discharge level 024 AH, SOC: 62%, I: 1A, L:3788, l:3825, H:3810, B:022, PT:028C, BT:021C, PV:106554, M:Bike On 00628 11/27/2025 22:17:25 SOC:23318,60887,24203,114800,79,72,62,50 00629 11/27/2025 22:18:25 Discharge level 024 AH, SOC: 62%, I: 1A, L:3784, l:3825, H:3805, B:021, PT:028C, BT:022C, PV:106414, M:Bike On 00630 11/27/2025 22:18:25 SOC:23615,61686,24721,114800,79,71,62,55 00631 11/27/2025 22:19:25 Discharge level 025 AH, SOC: 62%, I:-27A, L:3812, l:3845, H:3827, B:015, PT:028C, BT:022C, PV:107030, M:Bike On 00632 11/27/2025 22:19:25 SOC:23728,62124,25197,114800,79,73,62,44 00633 11/27/2025 22:20:25 Discharge level 025 AH, SOC: 62%, I: 58A, L:3690, l:3760, H:3736, B:046, PT:028C, BT:023C, PV:104304, M:Bike On 00634 11/27/2025 22:20:25 SOC:23900,62251,25805,114800,78,64,62,94 00635 11/27/2025 22:21:25 Discharge level 026 AH, SOC: 62%, I: 1A, L:3771, l:3809, H:3790, B:019, PT:028C, BT:023C, PV:106019, M:Bike On 00636 11/27/2025 22:21:25 SOC:24092,62468,26370,114800,78,70,62,51 00637 11/27/2025 22:22:25 Discharge level 027 AH, SOC: 61%, I: 48A, L:3708, l:3771, H:3742, B:034, PT:028C, BT:023C, PV:104562, M:Bike On 00638 11/27/2025 22:22:25 SOC:24532,62582,27118,114800,77,65,61,85 00639 11/27/2025 22:23:25 Discharge level 027 AH, SOC: 61%, I: 2A, L:3762, l:3793, H:3781, B:019, PT:028C, BT:023C, PV:105747, M:Bike On 00640 11/27/2025 22:23:25 SOC:24977,63400,27621,114800,76,68,61,42 00641 11/27/2025 22:24:25 Discharge level 028 AH, SOC: 61%, I: 1A, L:3756, l:3791, H:3775, B:019, PT:028C, BT:023C, PV:105580, M:Bike On 00642 11/27/2025 22:24:25 SOC:25474,64156,28169,114800,76,68,61,48 00643 11/27/2025 22:25:25 Discharge level 028 AH, SOC: 61%, I: 2A, L:3759, l:3787, H:3777, B:018, PT:028C, BT:024C, PV:105631, M:Bike On 00644 11/27/2025 22:25:25 SOC:25645,64682,28554,114800,76,67,61,37 00645 11/27/2025 22:26:25 Discharge level 029 AH, SOC: 61%, I: 60A, L:3700, l:3758, H:3729, B:029, PT:028C, BT:023C, PV:104220, M:Bike On 00646 11/27/2025 22:26:25 SOC:26150,65417,29086,114800,75,64,61,78 00647 11/27/2025 22:27:25 Discharge level 029 AH, SOC: 60%, I: 2A, L:3732, l:3779, H:3751, B:019, PT:028C, BT:022C, PV:104903, M:Bike On 00648 11/27/2025 22:27:25 SOC:26881,65854,29849,114800,74,66,60,64 00649 11/27/2025 22:28:25 Discharge level 031 AH, SOC: 56%, I:100A, L:3560, l:3693, H:3626, B:066, PT:029C, BT:023C, PV:101063, M:Bike On 00650 11/27/2025 22:28:25 SOC:28766,65244,31747,114800,73,55,56,182 00651 11/27/2025 22:28:25 Discharge cutback 83% 00652 11/27/2025 22:28:25 715A 00653 11/27/2025 22:29:25 Discharge level 032 AH, SOC: 55%, I: 1A, L:3698, l:3743, H:3721, B:023, PT:029C, BT:024C, PV:104058, M:Bike On 00654 11/27/2025 22:29:25 SOC:29503,65303,32617,114800,72,62,55,62 00655 11/27/2025 22:30:25 Discharge level 032 AH, SOC: 56%, I: 1A, L:3716, l:3744, H:3735, B:019, PT:029C, BT:024C, PV:104444, M:Bike On 00656 11/27/2025 22:30:25 SOC:29485,65692,32894,114800,72,62,56,38 00657 11/27/2025 22:31:25 Discharge level 032 AH, SOC: 56%, I: 1A, L:3731, l:3746, H:3747, B:016, PT:029C, BT:023C, PV:104802, M:Bike On 00658 11/27/2025 22:31:25 SOC:29511,66977,32922,114800,72,63,56,21 00659 11/27/2025 22:32:18 Contactor was Opened Pack V: 104944mV, Switched V: 104920mV, Prechg Pct: 100%, Dischg Cur: 1546mA 00660 11/27/2025 22:32:18 System Turned Off 00661 11/27/2025 22:32:19 DEBUG: CAN Link Is Down 00662 11/27/2025 22:32:19 DEBUG: Entered Idle State 00663 11/27/2025 22:32:25 Current Sensor Zeroed old: 2504mV, new: 2506mV, corrfact: 250 00664 11/27/2025 22:32:26 Discharge level 032 AH, SOC: 57%, I: 0A, L:3740, l:3750, H:3753, B:013, PT:029C, BT:024C, PV:104986, M:Idle 00665 11/27/2025 22:32:26 SOC:29529,68088,32945,114800,72,63,57,13 00666 11/27/2025 22:32:31 System Turned On 00667 11/27/2025 22:32:31 Rev:45,Build:2023-05-20_045619 958 banka 00668 11/27/2025 22:32:31 Pack:2019_monolith,Numbricks:4 00669 11/27/2025 22:32:31 DEBUG: Entered Running State 00670 11/27/2025 22:32:31 DEBUG: CAN NOT Receiving Syncs 00671 11/27/2025 22:32:31 DEBUG: CAN Link Is Up 00672 11/27/2025 22:32:32 DEBUG: Resetting CAN0 due to error passive mode 00673 11/27/2025 22:32:32 Discharge level 032 AH, SOC: 57%, I: 0A, L:3740, l:3750, H:3754, B:014, PT:029C, BT:024C, PV:104987, M:Bike On 00674 11/27/2025 22:32:32 SOC:29524,68088,32945,114800,72,63,57,13 00675 11/27/2025 22:32:35 DEBUG: CAN Receiving Syncs 00676 11/27/2025 22:32:36 Contactor drive turned on Pack V: 104985mV, Switched V: 92356mV, Duty Cycle: 38% 00677 11/27/2025 22:32:36 Contactor was Closed Pack V: 104985mV, Switched V: 92356mV, Prechg Pct: 88%, Dischg Cur: 636mA 00678 11/27/2025 22:32:38 DEBUG: Entered Charging State 00679 11/27/2025 22:32:38 DEBUG: CAN NOT Receiving Syncs 00680 11/27/2025 22:32:38 DEBUG: Entered Running State 00681 11/27/2025 22:32:39 Discharge level 032 AH, SOC: 57%, I: 0A, L:3740, l:3749, H:3754, B:014, PT:029C, BT:024C, PV:104995, M:Bike On 00682 11/27/2025 22:32:39 SOC:29480,68106,32945,114800,72,63,57,13 00683 11/27/2025 22:32:40 DEBUG: CAN Receiving Syncs 00684 11/27/2025 22:32:48 DEBUG: Entered Charging State 00685 11/27/2025 22:32:48 DEBUG: CAN NOT Receiving Syncs 00686 11/27/2025 22:32:49 Discharge level 032 AH, SOC: 57%, I: 1A, L:3741, l:3750, H:3754, B:013, PT:029C, BT:024C, PV:105008, M:Charge 00687 11/27/2025 22:32:49 SOC:29431,68153,32946,114800,72,63,57,12 00688 11/27/2025 22:32:50 DEBUG: CAN Receiving Syncs 00689 11/27/2025 22:42:49 Discharge level 031 AH, SOC: 67%, I:-12A, L:3803, l:3787, H:3812, B:009, PT:028C, BT:033C, PV:106614, M:Charge 00690 11/27/2025 22:42:49 SOC:20810,61534,31011,114800,73,68,67,-21 00691 11/27/2025 22:52:49 Discharge level 029 AH, SOC: 71%, I:-11A, L:3834, l:3818, H:3845, B:011, PT:028C, BT:034C, PV:107466, M:Charge 00692 11/27/2025 22:52:49 SOC:17604,60294,29062,114800,75,71,71,-22 00693 11/27/2025 23:02:49 Discharge level 027 AH, SOC: 74%, I:-11A, L:3862, l:3845, H:3872, B:010, PT:028C, BT:035C, PV:108244, M:Charge 00694 11/27/2025 23:02:49 SOC:15692,60324,27138,114800,77,74,74,-21 00695 11/27/2025 23:12:57 Discharge level 025 AH, SOC: 77%, I:-11A, L:3890, l:3874, H:3896, B:006, PT:027C, BT:037C, PV:108994, M:Charge 00696 11/27/2025 23:12:57 SOC:14059,60632,25213,114800,79,77,77,-21 00697 11/27/2025 23:22:57 Discharge level 023 AH, SOC: 80%, I:-11A, L:3914, l:3898, H:3919, B:005, PT:027C, BT:039C, PV:109666, M:Charge 00698 11/27/2025 23:22:57 SOC:12627,61091,23339,114800,80,79,80,-21 00699 11/27/2025 23:32:57 Discharge level 021 AH, SOC: 82%, I:-11A, L:3936, l:3920, H:3941, B:005, PT:026C, BT:039C, PV:110291, M:Charge 00700 11/27/2025 23:32:57 SOC:11435,61788,21467,114800,82,81,82,-21 00701 11/27/2025 23:42:57 Discharge level 019 AH, SOC: 84%, I:-11A, L:3958, l:3942, H:3962, B:004, PT:026C, BT:039C, PV:110881, M:Charge 00702 11/27/2025 23:42:57 SOC:10417,62639,19615,114800,83,83,84,-21 00703 11/27/2025 23:52:57 Discharge level 017 AH, SOC: 86%, I:-11A, L:3978, l:3961, H:3982, B:004, PT:025C, BT:036C, PV:111439, M:Charge 00704 11/27/2025 23:52:57 SOC:9331,63397,17789,114800,85,85,86,-21 00705 11/28/2025 00:02:57 Discharge level 015 AH, SOC: 87%, I:-10A, L:3997, l:3981, H:4001, B:004, PT:025C, BT:034C, PV:111972, M:Charge 00706 11/28/2025 00:02:57 SOC:8457,64349,15981,114800,87,86,87,-20 00707 11/28/2025 00:12:57 Discharge level 014 AH, SOC: 89%, I:-10A, L:4017, l:4001, H:4020, B:003, PT:024C, BT:035C, PV:112522, M:Charge 00708 11/28/2025 00:12:57 SOC:7349,65048,14192,114800,88,88,89,-20 00709 11/28/2025 00:18:57 Charged To Full 013 AH, SOC: 90%, L:4029, H:4033, B:004, PT:024C, BT:034C, PV:112748 00710 11/28/2025 00:18:57 SOC adjusted for voltage old: 6749283uAH (soc:90%), new: 5896867uAH (soc:91%), low cell: 4029 mV 00711 11/28/2025 00:23:05 Discharge level 009 AH, SOC: 92%, I:-10A, L:4036, l:4020, H:4041, B:005, PT:024C, BT:035C, PV:113074, M:Charge 00712 11/28/2025 00:23:05 SOC:5946,66308,9601,114800,92,90,92,-20 00713 11/28/2025 00:33:05 Discharge level 007 AH, SOC: 93%, I:-10A, L:4056, l:4040, H:4060, B:004, PT:024C, BT:036C, PV:113631, M:Charge 00714 11/28/2025 00:33:05 SOC:5110,67251,7839,114800,94,92,93,-19 00715 11/28/2025 00:43:05 Discharge level 006 AH, SOC: 95%, I:-10A, L:4076, l:4060, H:4080, B:004, PT:023C, BT:035C, PV:114186, M:Charge 00716 11/28/2025 00:43:05 SOC:3871,67779,6091,114800,95,94,95,-19 00717 11/28/2025 00:53:05 Discharge level 004 AH, SOC: 97%, I:-10A, L:4096, l:4079, H:4101, B:005, PT:023C, BT:038C, PV:114729, M:Charge 00718 11/28/2025 00:53:05 SOC:2637,68291,4362,114800,97,96,97,-19 00719 11/28/2025 01:33:36 DEBUG: CAN Link Is Down 00720 11/28/2025 01:33:40 Contactor was Opened Pack V: 115980mV, Switched V: 115987mV, Prechg Pct: 100%, Dischg Cur: 454mA 00721 11/28/2025 01:33:40 DEBUG: CAN Link Is Up 00722 11/28/2025 01:33:42 System Turned Off 00723 11/28/2025 01:33:43 DEBUG: CAN Link Is Down 00724 11/28/2025 01:33:43 DEBUG: Entered Idle State 00725 11/28/2025 01:33:49 Current Sensor Zeroed old: 2506mV, new: 2506mV, corrfact: 250 00726 11/28/2025 01:33:50 Discharge level 000 AH, SOC:100%, I: 0A, L:4145, l:4141, H:4149, B:004, PT:022C, BT:034C, PV:115986, M:Idle 00727 11/28/2025 01:33:50 SOC:0,69299,0,114800,100,100,100,-5 00728 11/28/2025 01:34:10 Voltage Across Contactor: 102484mV (Okay) 00729 11/28/2025 08:02:43 System Turned On 00730 11/28/2025 08:02:43 Rev:45,Build:2023-05-20_045619 958 banka 00731 11/28/2025 08:02:43 Pack:2019_monolith,Numbricks:4 00732 11/28/2025 08:02:43 DEBUG: Entered Charging State 00733 11/28/2025 08:02:43 DEBUG: CAN NOT Receiving Syncs 00734 11/28/2025 08:02:43 DEBUG: CAN Link Is Up 00735 11/28/2025 08:02:43 DEBUG: Entered Running State 00736 11/28/2025 08:02:44 DEBUG: Resetting CAN0 due to error passive mode 00737 11/28/2025 08:02:44 Discharge level 000 AH, SOC:100%, I: 0A, L:4118, l:4113, H:4121, B:003, PT:018C, BT:036C, PV:115360, M:Bike On 00738 11/28/2025 08:02:44 SOC:1,69299,0,114800,100,99,100,-5 00739 11/28/2025 08:02:47 DEBUG: CAN Receiving Syncs 00740 11/28/2025 08:02:48 Contactor drive turned on Pack V: 115340mV, Switched V: 101139mV, Duty Cycle: 34% 00741 11/28/2025 08:02:48 Contactor was Closed Pack V: 115340mV, Switched V: 101139mV, Prechg Pct: 88%, Dischg Cur: 454mA 00742 11/28/2025 08:03:44 Discharge level 000 AH, SOC:100%, I: 0A, L:4117, l:4116, H:4120, B:003, PT:018C, BT:033C, PV:115333, M:Bike On 00743 11/28/2025 08:03:44 SOC:63,69292,0,114800,100,99,100,-1 00744 11/28/2025 08:04:44 Discharge level 000 AH, SOC:100%, I: 0A, L:4116, l:4116, H:4120, B:004, PT:018C, BT:031C, PV:115324, M:Bike On 00745 11/28/2025 08:04:44 SOC:118,69279,2,114800,100,99,100,0 00746 11/28/2025 08:05:44 Discharge level 000 AH, SOC:100%, I: 6A, L:4098, l:4102, H:4104, B:006, PT:018C, BT:030C, PV:114848, M:Bike On 00747 11/28/2025 08:05:44 SOC:173,69260,8,114800,100,98,100,4 00748 11/28/2025 08:06:44 Discharge level 000 AH, SOC:100%, I: 31A, L:4047, l:4073, H:4059, B:012, PT:018C, BT:028C, PV:113497, M:Bike On 00749 11/28/2025 08:06:45 SOC:371,68940,179,114800,100,95,100,27 00750 11/28/2025 08:07:44 Discharge level 000 AH, SOC: 99%, I: 90A, L:3884, l:3979, H:3918, B:034, PT:018C, BT:028C, PV:109280, M:Bike On 00751 11/28/2025 08:07:45 SOC:1135,67784,946,114800,100,86,99,97 00752 11/28/2025 08:08:44 Discharge level 001 AH, SOC: 97%, I:139A, L:3765, l:3921, H:3815, B:050, PT:019C, BT:027C, PV:106171, M:Bike On 00753 11/28/2025 08:08:45 SOC:2179,66325,1964,114800,99,80,97,160 00754 11/28/2025 08:09:44 Discharge level 003 AH, SOC: 95%, I: 2A, L:4009, l:4063, H:4022, B:013, PT:019C, BT:027C, PV:112463, M:Bike On 00755 11/28/2025 08:09:45 SOC:3341,64796,3119,114800,98,94,95,58 00756 11/28/2025 08:10:44 Discharge level 003 AH, SOC: 94%, I:-26A, L:4045, l:4074, H:4054, B:009, PT:019C, BT:027C, PV:113416, M:Bike On 00757 11/28/2025 08:10:45 SOC:4149,63756,3990,114800,97,95,94,31 00758 11/28/2025 08:11:44 Discharge level 004 AH, SOC: 94%, I:-19A, L:4060, l:4076, H:4066, B:006, PT:020C, BT:026C, PV:113798, M:Bike On 00759 11/28/2025 08:11:45 SOC:4325,63384,4209,114800,97,95,94,17 00760 11/28/2025 08:12:45 Discharge level 004 AH, SOC: 93%, I: 29A, L:3993, l:4035, H:4009, B:016, PT:020C, BT:026C, PV:112089, M:Bike On 00761 11/28/2025 08:12:45 SOC:4579,62949,4509,114800,97,91,93,46 00762 11/28/2025 08:13:45 Discharge level 005 AH, SOC: 92%, I: 1A, L:4015, l:4051, H:4026, B:011, PT:020C, BT:025C, PV:112621, M:Bike On 00763 11/28/2025 08:13:45 SOC:5067,62391,5019,114800,96,93,92,41 00764 11/28/2025 08:14:45 Discharge level 005 AH, SOC: 91%, I:263A, L:3680, l:3864, H:3743, B:063, PT:020C, BT:025C, PV:103982, M:Bike On 00765 11/28/2025 08:14:45 SOC:5661,61728,5673,114800,96,76,91,210 00766 11/28/2025 08:15:45 Discharge level 006 AH, SOC: 90%, I:189A, L:3728, l:3896, H:3780, B:052, PT:021C, BT:025C, PV:105212, M:Bike On 00767 11/28/2025 08:15:45 SOC:6391,60946,6467,114800,95,79,90,191 00768 11/28/2025 08:16:45 Discharge level 007 AH, SOC: 88%, I:-40A, L:4006, l:4051, H:4014, B:008, PT:021C, BT:026C, PV:112314, M:Bike On 00769 11/28/2025 08:16:45 SOC:7520,59948,7672,114800,94,93,88,50 00770 11/28/2025 08:17:45 Discharge level 008 AH, SOC: 86%, I:332A, L:3471, l:3749, H:3558, B:087, PT:022C, BT:025C, PV: 98521, M:Bike On 00771 11/28/2025 08:17:45 SOC:8773,59063,8972,114800,93,63,86,334 00772 11/28/2025 08:18:45 Discharge level 009 AH, SOC: 84%, I: 87A, L:3784, l:3900, H:3825, B:041, PT:022C, BT:025C, PV:106639, M:Bike On 00773 11/28/2025 08:18:45 SOC:9690,58617,9917,114800,92,79,84,138 00774 11/28/2025 08:19:45 Discharge level 011 AH, SOC: 82%, I: 54A, L:3846, l:3936, H:3875, B:029, PT:023C, BT:025C, PV:108208, M:Bike On 00775 11/28/2025 08:19:45 SOC:10764,58208,11027,114800,91,82,82,110 00776 11/28/2025 08:20:45 Discharge level 012 AH, SOC: 80%, I: 97A, L:3742, l:3872, H:3787, B:045, PT:023C, BT:025C, PV:105572, M:Bike On 00777 11/28/2025 08:20:45 SOC:12032,57902,12304,114800,90,76,80,157 00778 11/28/2025 08:21:45 Discharge level 014 AH, SOC: 76%, I: 63A, L:3748, l:3900, H:3788, B:040, PT:024C, BT:025C, PV:105672, M:Bike On 00779 11/28/2025 08:21:45 SOC:13872,57414,14157,114800,88,79,76,182 00780 11/28/2025 08:22:45 Discharge level 015 AH, SOC: 73%, I: -1A, L:3863, l:3939, H:3883, B:020, PT:024C, BT:025C, PV:108548, M:Bike On 00781 11/28/2025 08:22:45 SOC:15509,57322,15841,114800,87,82,73,94 00782 11/28/2025 08:23:45 Discharge level 016 AH, SOC: 73%, I: 82A, L:3745, l:3851, H:3787, B:042, PT:025C, BT:025C, PV:105633, M:Bike On 00783 11/28/2025 08:23:45 SOC:15986,57510,16542,114800,86,74,73,130 00784 11/28/2025 08:24:45 Discharge level 018 AH, SOC: 69%, I:185A, L:3533, l:3774, H:3610, B:077, PT:025C, BT:025C, PV:100326, M:Bike On 00785 11/28/2025 08:24:45 SOC:18171,57356,18746,114800,84,65,69,297 00786 11/28/2025 08:24:45 Discharge cutback 89% 00787 11/28/2025 08:24:45 766A 00788 11/28/2025 08:25:45 Discharge level 021 AH, SOC: 64%, I: 0A, L:3721, l:3847, H:3758, B:037, PT:026C, BT:025C, PV:104905, M:Bike On 00789 11/28/2025 08:25:45 SOC:20741,57344,21337,114800,82,73,64,162 00790 11/28/2025 08:26:45 Discharge level 024 AH, SOC: 59%, I:132A, L:3561, l:3763, H:3627, B:066, PT:027C, BT:025C, PV:100987, M:Bike On 00791 11/28/2025 08:26:45 SOC:23722,57309,24331,114800,79,63,59,274 00792 11/28/2025 08:26:45 Discharge cutback 81% 00793 11/28/2025 08:26:45 695A 00794 11/28/2025 08:27:45 Discharge level 025 AH, SOC: 57%, I:145A, L:3565, l:3730, H:3631, B:066, PT:028C, BT:025C, PV:101100, M:Bike On 00795 11/28/2025 08:27:45 SOC:25177,58285,25834,114800,78,60,57,235 00796 11/28/2025 08:28:45 Discharge level 027 AH, SOC: 54%, I:130A, L:3574, l:3725, H:3634, B:060, PT:029C, BT:026C, PV:101252, M:Bike On 00797 11/28/2025 08:28:45 SOC:27164,58982,27864,114800,76,59,54,217 00798 11/28/2025 08:28:45 Discharge cutback 89% 00799 11/28/2025 08:28:45 763A 00800 11/28/2025 08:29:45 Discharge level 029 AH, SOC: 52%, I:116A, L:3571, l:3714, H:3630, B:059, PT:030C, BT:026C, PV:101155, M:Bike On 00801 11/28/2025 08:29:45 SOC:28927,59818,29695,114800,75,57,52,217 00802 11/28/2025 08:29:45 Discharge cutback 88% 00803 11/28/2025 08:29:45 759A 00804 11/28/2025 08:30:45 Discharge level 031 AH, SOC: 50%, I:226A, L:3458, l:3638, H:3541, B:083, PT:030C, BT:026C, PV: 98450, M:Bike On 00805 11/28/2025 08:30:45 SOC:30559,60827,31363,114800,73,47,50,287 00806 11/28/2025 08:30:45 Discharge cutback 85% 00807 11/28/2025 08:30:45 729A 00808 11/28/2025 08:31:45 Discharge level 032 AH, SOC: 50%, I: 1A, L:3698, l:3745, H:3723, B:025, PT:030C, BT:025C, PV:104086, M:Bike On 00809 11/28/2025 08:31:45 SOC:30931,61625,32109,114800,73,62,50,75 00810 11/28/2025 08:32:45 Discharge level 032 AH, SOC: 51%, I: 0A, L:3700, l:3746, H:3721, B:021, PT:031C, BT:026C, PV:104064, M:Bike On 00811 11/28/2025 08:32:45 SOC:31223,62555,32750,114800,72,63,51,74 00812 11/28/2025 08:33:45 Discharge level 032 AH, SOC: 52%, I: 1A, L:3722, l:3745, H:3739, B:017, PT:031C, BT:026C, PV:104606, M:Bike On 00813 11/28/2025 08:33:45 SOC:30942,63731,32847,114800,72,63,52,36 00814 11/28/2025 08:34:45 Discharge level 033 AH, SOC: 52%, I: 59A, L:3653, l:3713, H:3682, B:029, PT:031C, BT:026C, PV:102886, M:Bike On 00815 11/28/2025 08:34:45 SOC:31662,64689,33726,114800,71,58,52,95 00816 11/28/2025 08:35:45 Discharge level 034 AH, SOC: 52%, I: 41A, L:3666, l:3713, H:3691, B:025, PT:031C, BT:025C, PV:103182, M:Bike On 00817 11/28/2025 08:35:45 SOC:31870,65508,34218,114800,71,59,52,78 00818 11/28/2025 08:36:45 Discharge level 034 AH, SOC: 52%, I: 1A, L:3711, l:3731, H:3727, B:016, PT:031C, BT:027C, PV:104251, M:Bike On 00819 11/28/2025 08:36:45 SOC:31791,66229,34496,114800,70,61,52,33 00820 11/28/2025 08:37:45 Discharge level 034 AH, SOC: 54%, I: 0A, L:3722, l:3733, H:3735, B:013, PT:031C, BT:026C, PV:104506, M:Bike On 00821 11/28/2025 08:37:45 SOC:31770,67664,34520,114800,70,61,54,18 00822 11/28/2025 08:37:59 Contactor was Opened Pack V: 104556mV, Switched V: 104526mV, Prechg Pct: 100%, Dischg Cur: 636mA 00823 11/28/2025 08:37:59 System Turned Off 00824 11/28/2025 08:38:00 DEBUG: CAN Link Is Down 00825 11/28/2025 08:38:00 DEBUG: Entered Idle State 00826 11/28/2025 08:38:06 Current Sensor Zeroed old: 2506mV, new: 2504mV, corrfact: 252 00827 11/28/2025 08:38:07 Discharge level 034 AH, SOC: 54%, I: 0A, L:3726, l:3736, H:3739, B:013, PT:031C, BT:027C, PV:104595, M:Idle 00828 11/28/2025 08:38:07 SOC:31684,67806,34521,114800,70,62,54,16 00829 11/28/2025 08:38:29 Voltage Across Contactor: 91642mV (Okay) 00830 11/28/2025 09:32:12 System Turned On 00831 11/28/2025 09:32:12 Rev:45,Build:2023-05-20_045619 958 banka 00832 11/28/2025 09:32:12 Pack:2019_monolith,Numbricks:4 00833 11/28/2025 09:32:12 DEBUG: Entered Running State 00834 11/28/2025 09:32:12 DEBUG: CAN NOT Receiving Syncs 00835 11/28/2025 09:32:12 DEBUG: CAN Link Is Up 00836 11/28/2025 09:32:13 DEBUG: Resetting CAN0 due to error passive mode 00837 11/28/2025 09:32:13 Discharge level 034 AH, SOC: 54%, I: 0A, L:3755, l:3765, H:3760, B:005, PT:029C, BT:029C, PV:105223, M:Bike On 00838 11/28/2025 09:32:13 SOC:31676,67806,34521,114800,70,65,54,16 00839 11/28/2025 09:32:16 DEBUG: CAN Receiving Syncs 00840 11/28/2025 09:32:17 Contactor drive turned on Pack V: 105216mV, Switched V: 92278mV, Duty Cycle: 38% 00841 11/28/2025 09:32:17 Contactor was Closed Pack V: 105216mV, Switched V: 92278mV, Prechg Pct: 88%, Dischg Cur: 636mA 00842 11/28/2025 09:33:13 Discharge level 034 AH, SOC: 55%, I: 0A, L:3755, l:3763, H:3759, B:004, PT:029C, BT:029C, PV:105205, M:Bike On 00843 11/28/2025 09:33:13 SOC:31318,68863,34534,114800,70,65,55,11 00844 11/28/2025 09:34:13 Discharge level 034 AH, SOC: 56%, I: 1A, L:3738, l:3758, H:3743, B:005, PT:029C, BT:029C, PV:104747, M:Bike On 00845 11/28/2025 09:34:13 SOC:31311,69654,34883,114800,70,64,56,30 00846 11/28/2025 09:35:13 Discharge level 035 AH, SOC: 56%, I: 1A, L:3722, l:3738, H:3731, B:009, PT:029C, BT:029C, PV:104360, M:Bike On 00847 11/28/2025 09:35:13 SOC:30969,69882,35106,114800,70,62,56,23 00848 11/28/2025 09:36:13 Discharge level 035 AH, SOC: 56%, I: 32A, L:3698, l:3726, H:3711, B:013, PT:029C, BT:029C, PV:103766, M:Bike On 00849 11/28/2025 09:36:13 SOC:30908,70094,35469,114800,70,60,56,42 00850 11/28/2025 09:37:13 Discharge level 035 AH, SOC: 57%, I: 27A, L:3706, l:3728, H:3717, B:011, PT:029C, BT:029C, PV:103960, M:Bike On 00851 11/28/2025 09:37:13 SOC:30713,70772,35536,114800,70,61,57,32 00852 11/28/2025 09:38:13 Discharge level 036 AH, SOC: 56%, I:180A, L:3513, l:3633, H:3563, B:050, PT:029C, BT:029C, PV: 99248, M:Bike On 00853 11/28/2025 09:38:13 SOC:31489,70442,36577,114800,69,46,56,178 00854 11/28/2025 09:39:13 Discharge level 036 AH, SOC: 56%, I: 1A, L:3713, l:3730, H:3720, B:007, PT:029C, BT:029C, PV:104099, M:Bike On 00855 11/28/2025 09:39:13 SOC:31360,70682,36765,114800,68,61,56,25 00856 11/28/2025 09:40:13 Discharge level 037 AH, SOC: 56%, I: 14A, L:3698, l:3720, H:3708, B:010, PT:029C, BT:028C, PV:103744, M:Bike On 00857 11/28/2025 09:40:13 SOC:31464,71097,37026,114800,68,60,56,32 00858 11/28/2025 09:41:13 Discharge level 037 AH, SOC: 56%, I: -3A, L:3717, l:3728, H:3724, B:007, PT:028C, BT:029C, PV:104204, M:Bike On 00859 11/28/2025 09:41:13 SOC:31592,71631,37245,114800,68,61,56,17 00860 11/28/2025 09:42:13 Discharge level 037 AH, SOC: 57%, I: 1A, L:3718, l:3725, H:3724, B:006, PT:028C, BT:028C, PV:104215, M:Bike On 00861 11/28/2025 09:42:13 SOC:31619,72279,37319,114800,68,60,57,11 00862 11/28/2025 09:42:27 Contactor was Opened Pack V: 104239mV, Switched V: 104172mV, Prechg Pct: 100%, Dischg Cur: 1091mA 00863 11/28/2025 09:42:27 System Turned Off 00864 11/28/2025 09:42:28 DEBUG: CAN Link Is Down 00865 11/28/2025 09:42:28 DEBUG: Entered Idle State 00866 11/28/2025 09:42:34 Current Sensor Zeroed old: 2504mV, new: 2507mV, corrfact: 249 00867 11/28/2025 09:42:35 Discharge level 037 AH, SOC: 57%, I: 0A, L:3720, l:3726, H:3726, B:006, PT:028C, BT:028C, PV:104271, M:Idle 00868 11/28/2025 09:42:36 SOC:31617,72446,37323,114800,68,60,57,9 00869 11/28/2025 09:42:57 Voltage Across Contactor: 90837mV (Okay) 00870 11/28/2025 10:56:51 System Turned On 00871 11/28/2025 10:56:51 Rev:45,Build:2023-05-20_045619 958 banka 00872 11/28/2025 10:56:51 Pack:2019_monolith,Numbricks:4 00873 11/28/2025 10:56:51 DEBUG: Entered Running State 00874 11/28/2025 10:56:51 DEBUG: CAN NOT Receiving Syncs 00875 11/28/2025 10:56:51 DEBUG: CAN Link Is Up 00876 11/28/2025 10:56:52 DEBUG: Resetting CAN0 due to error passive mode 00877 11/28/2025 10:56:52 Discharge level 037 AH, SOC: 57%, I: 0A, L:3733, l:3740, H:3738, B:005, PT:025C, BT:025C, PV:104599, M:Bike On 00878 11/28/2025 10:56:52 SOC:31612,72446,37323,114800,68,62,57,9 00879 11/28/2025 10:56:55 DEBUG: CAN Receiving Syncs 00880 11/28/2025 10:56:56 Contactor drive turned on Pack V: 104591mV, Switched V: 91687mV, Duty Cycle: 38% 00881 11/28/2025 10:56:56 Contactor was Closed Pack V: 104591mV, Switched V: 91687mV, Prechg Pct: 88%, Dischg Cur: 545mA 00882 11/28/2025 10:57:52 Discharge level 037 AH, SOC: 57%, I: 0A, L:3732, l:3737, H:3737, B:005, PT:025C, BT:025C, PV:104583, M:Bike On 00883 11/28/2025 10:57:52 SOC:31226,72451,37323,114800,68,62,57,6 00884 11/28/2025 10:58:52 Discharge level 037 AH, SOC: 58%, I: 0A, L:3732, l:3735, H:3737, B:005, PT:025C, BT:025C, PV:104575, M:Bike On 00885 11/28/2025 10:58:52 SOC:30873,72451,37323,114800,68,62,58,5 00886 11/28/2025 10:59:52 Discharge level 037 AH, SOC: 58%, I: 1A, L:3714, l:3735, H:3719, B:005, PT:025C, BT:026C, PV:104094, M:Bike On 00887 11/28/2025 10:59:52 SOC:30878,72510,37538,114800,68,61,58,27 00888 11/28/2025 11:00:52 Discharge level 037 AH, SOC: 58%, I: 0A, L:3722, l:3728, H:3727, B:005, PT:025C, BT:026C, PV:104300, M:Bike On 00889 11/28/2025 11:00:52 SOC:30736,72429,37690,114800,68,61,58,8 00890 11/28/2025 11:01:52 Discharge level 037 AH, SOC: 58%, I: 0A, L:3716, l:3726, H:3720, B:004, PT:025C, BT:026C, PV:104122, M:Bike On 00891 11/28/2025 11:01:52 SOC:30759,72330,37929,114800,67,60,58,13 00892 11/28/2025 11:02:52 Discharge level 038 AH, SOC: 58%, I: 10A, L:3699, l:3713, H:3706, B:007, PT:025C, BT:026C, PV:103700, M:Bike On 00893 11/28/2025 11:02:52 SOC:30795,72436,38079,114800,67,59,58,19 00894 11/28/2025 11:03:52 Discharge level 038 AH, SOC: 58%, I: 1A, L:3708, l:3721, H:3713, B:005, PT:025C, BT:026C, PV:103901, M:Bike On 00895 11/28/2025 11:03:52 SOC:30935,72234,38388,114800,67,60,58,17 00896 11/28/2025 11:04:52 Discharge level 038 AH, SOC: 57%, I: 0A, L:3695, l:3711, H:3703, B:008, PT:025C, BT:026C, PV:103602, M:Bike On 00897 11/28/2025 11:04:52 SOC:31172,72083,38746,114800,67,59,57,21 00898 11/28/2025 11:05:52 Discharge level 039 AH, SOC: 56%, I: 38A, L:3642, l:3686, H:3658, B:016, PT:025C, BT:024C, PV:102278, M:Bike On 00899 11/28/2025 11:05:52 SOC:31641,71812,39296,114800,66,55,56,58 00900 11/28/2025 11:06:52 Discharge level 039 AH, SOC: 56%, I: 70A, L:3601, l:3655, H:3627, B:026, PT:025C, BT:026C, PV:101296, M:Bike On 00901 11/28/2025 11:06:52 SOC:31969,71597,39729,114800,66,51,56,72 00902 11/28/2025 11:07:52 Discharge level 040 AH, SOC: 55%, I: 0A, L:3685, l:3705, H:3692, B:007, PT:025C, BT:026C, PV:103329, M:Bike On 00903 11/28/2025 11:07:52 SOC:32158,71308,40083,114800,66,58,55,27 00904 11/28/2025 11:08:52 Discharge level 040 AH, SOC: 56%, I: 0A, L:3693, l:3702, H:3700, B:007, PT:025C, BT:026C, PV:103535, M:Bike On 00905 11/28/2025 11:08:52 SOC:32065,71282,40138,114800,66,57,56,12 00906 11/28/2025 11:09:52 Discharge level 040 AH, SOC: 56%, I: 0A, L:3697, l:3703, H:3705, B:008, PT:025C, BT:025C, PV:103654, M:Bike On 00907 11/28/2025 11:09:52 SOC:31913,71282,40138,114800,66,57,56,7 00908 11/28/2025 11:10:52 Discharge level 040 AH, SOC: 56%, I: 0A, L:3700, l:3704, H:3706, B:006, PT:025C, BT:025C, PV:103703, M:Bike On 00909 11/28/2025 11:10:52 SOC:31746,71293,40145,114800,66,58,56,5 00910 11/28/2025 11:11:02 DEBUG: Entered Charging State 00911 11/28/2025 11:11:02 DEBUG: CAN NOT Receiving Syncs 00912 11/28/2025 11:11:03 Discharge level 040 AH, SOC: 56%, I: 0A, L:3700, l:3704, H:3706, B:006, PT:024C, BT:025C, PV:103714, M:Charge 00913 11/28/2025 11:11:03 SOC:31719,71293,40145,114800,66,58,56,5 00914 11/28/2025 11:11:03 DEBUG: CAN Receiving Syncs 00915 11/28/2025 11:21:03 Discharge level 038 AH, SOC: 61%, I:-12A, L:3751, l:3734, H:3761, B:010, PT:024C, BT:036C, PV:105175, M:Charge 00916 11/28/2025 11:21:03 SOC:26692,68284,38163,114800,67,62,61,-22 00917 11/28/2025 11:31:03 Discharge level 036 AH, SOC: 65%, I:-11A, L:3775, l:3757, H:3786, B:011, PT:024C, BT:038C, PV:105833, M:Charge 00918 11/28/2025 11:31:03 SOC:24152,67758,36167,114800,69,65,65,-22 00919 11/28/2025 11:41:03 Discharge level 034 AH, SOC: 68%, I:-12A, L:3796, l:3778, H:3809, B:013, PT:024C, BT:038C, PV:106434, M:Charge 00920 11/28/2025 11:41:03 SOC:22348,67956,34184,114800,71,67,68,-22 00921 11/28/2025 11:51:11 Discharge level 032 AH, SOC: 70%, I:-11A, L:3819, l:3801, H:3832, B:013, PT:024C, BT:038C, PV:107070, M:Charge 00922 11/28/2025 11:51:11 SOC:20823,68465,32168,114800,72,69,70,-22 00923 11/28/2025 12:01:11 Discharge level 030 AH, SOC: 72%, I:-12A, L:3843, l:3825, H:3856, B:013, PT:024C, BT:038C, PV:107729, M:Charge 00924 11/28/2025 12:01:11 SOC:19319,68947,30200,114800,74,72,72,-22 00925 11/28/2025 12:11:11 Discharge level 028 AH, SOC: 75%, I:-11A, L:3866, l:3849, H:3876, B:010, PT:024C, BT:037C, PV:108371, M:Charge 00926 11/28/2025 12:11:11 SOC:17757,69343,28257,114800,76,74,75,-22 00927 11/28/2025 12:21:11 Discharge level 026 AH, SOC: 77%, I:-11A, L:3892, l:3875, H:3899, B:007, PT:024C, BT:038C, PV:109078, M:Charge 00928 11/28/2025 12:21:11 SOC:16113,69655,26319,114800,78,77,77,-22 00929 11/28/2025 12:31:11 Discharge level 024 AH, SOC: 80%, I:-11A, L:3915, l:3898, H:3919, B:004, PT:024C, BT:041C, PV:109690, M:Charge 00930 11/28/2025 12:31:11 SOC:14579,70049,24410,114800,79,79,80,-21 00931 11/28/2025 12:41:11 Discharge level 022 AH, SOC: 82%, I:-10A, L:3936, l:3920, H:3940, B:004, PT:024C, BT:041C, PV:110272, M:Charge 00932 11/28/2025 12:41:11 SOC:13245,70636,22507,114800,81,81,82,-21 00933 11/28/2025 12:51:11 Discharge level 020 AH, SOC: 83%, I:-11A, L:3956, l:3940, H:3959, B:003, PT:024C, BT:039C, PV:110819, M:Charge 00934 11/28/2025 12:51:11 SOC:12165,71451,20631,114800,83,83,83,-21 00935 11/28/2025 13:01:11 Discharge level 018 AH, SOC: 85%, I:-11A, L:3976, l:3960, H:3979, B:003, PT:024C, BT:038C, PV:111372, M:Charge 00936 11/28/2025 13:01:11 SOC:11000,72181,18754,114800,84,85,85,-21 00937 11/28/2025 13:11:18 Discharge level 016 AH, SOC: 87%, I:-11A, L:3995, l:3979, H:3998, B:003, PT:024C, BT:033C, PV:111910, M:Charge 00938 11/28/2025 13:11:18 SOC:9723,72824,16855,114800,86,86,87,-21 00939 11/28/2025 13:21:18 Discharge level 015 AH, SOC: 89%, I:-10A, L:4014, l:3999, H:4016, B:002, PT:024C, BT:032C, PV:112427, M:Charge 00940 11/28/2025 13:21:18 SOC:8526,73495,15005,114800,87,88,89,-20 00941 11/28/2025 13:27:15 Charged To Full 013 AH, SOC: 90%, L:4025, H:4028, B:003, PT:024C, BT:031C, PV:112744 00942 11/28/2025 13:27:15 SOC adjusted for voltage old: 7811215uAH (soc:90%), new: 7386666uAH (soc:90%), low cell: 4025 mV 00943 11/28/2025 13:31:18 Discharge level 010 AH, SOC: 91%, I:-10A, L:4033, l:4018, H:4035, B:002, PT:024C, BT:030C, PV:112953, M:Charge 00944 11/28/2025 13:31:18 SOC:7143,74362,10749,114800,91,90,91,-20 00945 11/28/2025 13:41:18 Discharge level 008 AH, SOC: 92%, I:-10A, L:4052, l:4037, H:4056, B:004, PT:024C, BT:030C, PV:113503, M:Charge 00946 11/28/2025 13:41:18 SOC:6089,75152,8924,114800,93,92,92,-20 00947 11/28/2025 13:51:18 Discharge level 007 AH, SOC: 94%, I:-10A, L:4072, l:4057, H:4075, B:003, PT:024C, BT:030C, PV:114045, M:Charge 00948 11/28/2025 13:51:18 SOC:4819,75713,7113,114800,94,94,94,-20 00949 11/28/2025 14:01:18 Discharge level 005 AH, SOC: 96%, I:-10A, L:4089, l:4074, H:4093, B:004, PT:024C, BT:032C, PV:114567, M:Charge 00950 11/28/2025 14:01:18 SOC:3417,76124,5318,114800,96,95,96,-20 00951 11/28/2025 14:45:19 DEBUG: CAN Link Is Down 00952 11/28/2025 14:45:23 DEBUG: CAN Link Is Up 00953 11/28/2025 14:45:23 Contactor was Opened Pack V: 115939mV, Switched V: 116066mV, Prechg Pct: 100%, Dischg Cur: 90mA 00954 11/28/2025 14:45:26 System Turned Off 00955 11/28/2025 14:45:26 DEBUG: CAN Link Is Down 00956 11/28/2025 14:45:27 DEBUG: Entered Idle State 00957 11/28/2025 14:45:32 Current Sensor Zeroed old: 2507mV, new: 2505mV, corrfact: 251 00958 11/28/2025 14:45:34 Discharge level 000 AH, SOC:100%, I: 0A, L:4147, l:4144, H:4149, B:002, PT:024C, BT:034C, PV:116134, M:Idle 00959 11/28/2025 14:45:34 SOC:0,77009,0,114800,100,100,100,-5 00960 11/28/2025 14:45:53 Voltage Across Contactor: 103109mV (Okay) 00961 11/29/2025 05:52:07 System Turned On 00962 11/29/2025 05:52:07 Rev:45,Build:2023-05-20_045619 958 banka 00963 11/29/2025 05:52:07 Pack:2019_monolith,Numbricks:4 00964 11/29/2025 05:52:07 DEBUG: Entered Charging State 00965 11/29/2025 05:52:07 DEBUG: CAN NOT Receiving Syncs 00966 11/29/2025 05:52:07 DEBUG: Entered Running State 00967 11/29/2025 05:52:07 DEBUG: CAN Link Is Up 00968 11/29/2025 05:52:08 DEBUG: Resetting CAN0 due to error passive mode 00969 11/29/2025 05:52:08 Discharge level 000 AH, SOC:100%, I: 0A, L:4115, l:4110, H:4116, B:001, PT:016C, BT:022C, PV:115235, M:Bike On 00970 11/29/2025 05:52:08 SOC:1,77009,0,114800,100,99,100,-4 00971 11/29/2025 05:52:11 DEBUG: CAN Receiving Syncs 00972 11/29/2025 05:52:11 Contactor drive turned on Pack V: 115205mV, Switched V: 100785mV, Duty Cycle: 34% 00973 11/29/2025 05:52:11 Contactor was Closed Pack V: 115205mV, Switched V: 100785mV, Prechg Pct: 87%, Dischg Cur: 454mA 00974 11/29/2025 05:53:08 Discharge level 000 AH, SOC:100%, I: 0A, L:4114, l:4113, H:4115, B:001, PT:016C, BT:021C, PV:115207, M:Bike On 00975 11/29/2025 05:53:08 SOC:73,77008,0,114800,100,99,100,-1 00976 11/29/2025 05:54:08 Discharge level 000 AH, SOC:100%, I: 0A, L:4112, l:4112, H:4114, B:002, PT:016C, BT:022C, PV:115177, M:Bike On 00977 11/29/2025 05:54:08 SOC:139,76974,6,114800,100,99,100,0 00978 11/29/2025 05:55:08 Discharge level 000 AH, SOC:100%, I: 0A, L:4115, l:4119, H:4117, B:002, PT:016C, BT:022C, PV:115254, M:Bike On 00979 11/29/2025 05:55:08 SOC:275,76688,101,114800,100,99,100,4 00980 11/29/2025 05:56:08 Discharge level 000 AH, SOC:100%, I:-15A, L:4131, l:4126, H:4135, B:004, PT:016C, BT:022C, PV:115731, M:Bike On 00981 11/29/2025 05:56:08 SOC:485,76086,298,114800,100,100,100,-5 00982 11/29/2025 05:57:08 Discharge level 000 AH, SOC:100%, I: 1A, L:4095, l:4101, H:4099, B:004, PT:016C, BT:021C, PV:114729, M:Bike On 00983 11/29/2025 05:57:08 SOC:554,75609,387,114800,100,98,100,5 00984 11/29/2025 05:58:08 Discharge level 000 AH, SOC:100%, I: 1A, L:4100, l:4105, H:4103, B:003, PT:016C, BT:022C, PV:114854, M:Bike On 00985 11/29/2025 05:58:08 SOC:682,75106,520,114800,100,98,100,5 00986 11/29/2025 05:59:08 Discharge level 000 AH, SOC:100%, I: 1A, L:4099, l:4103, H:4102, B:003, PT:016C, BT:022C, PV:114835, M:Bike On 00987 11/29/2025 05:59:08 SOC:717,74826,559,114800,100,98,100,4 00988 11/29/2025 06:00:08 Discharge level 001 AH, SOC: 99%, I: 1A, L:4057, l:4083, H:4065, B:008, PT:016C, BT:022C, PV:113736, M:Bike On 00989 11/29/2025 06:00:08 SOC:1407,73642,1241,114800,99,96,99,23 00990 11/29/2025 06:01:08 Discharge level 001 AH, SOC: 98%, I: 56A, L:3937, l:4001, H:3963, B:026, PT:016C, BT:022C, PV:110651, M:Bike On 00991 11/29/2025 06:01:08 SOC:1816,72771,1635,114800,99,88,98,58 00992 11/29/2025 06:02:00 Contactor was Opened Pack V: 114092mV, Switched V: 114057mV, Prechg Pct: 100%, Dischg Cur: 818mA 00993 11/29/2025 06:02:00 System Turned Off 00994 11/29/2025 06:02:01 DEBUG: CAN Link Is Down 00995 11/29/2025 06:02:01 DEBUG: Entered Idle State 00996 11/29/2025 06:02:07 SOC adjusted for voltage old: 1923639uAH (soc:98%), new: 3623076uAH (soc:95%), low cell: 4074 mV 00997 11/29/2025 06:02:08 Discharge level 005 AH, SOC: 95%, I: 0A, L:4073, l:4084, H:4080, B:007, PT:016C, BT:022C, PV:114050, M:Idle 00998 11/29/2025 06:02:08 SOC:3623,72461,5740,114800,95,96,95,11 00999 11/29/2025 06:02:30 Voltage Across Contactor: 99418mV (Okay) 01000 11/29/2025 06:06:31 System Turned On 01001 11/29/2025 06:06:31 Rev:45,Build:2023-05-20_045619 958 banka 01002 11/29/2025 06:06:31 Pack:2019_monolith,Numbricks:4 01003 11/29/2025 06:06:31 DEBUG: Entered Running State 01004 11/29/2025 06:06:31 DEBUG: CAN NOT Receiving Syncs 01005 11/29/2025 06:06:32 DEBUG: CAN Link Is Up 01006 11/29/2025 06:06:32 DEBUG: Resetting CAN0 due to error passive mode 01007 11/29/2025 06:06:33 Discharge level 005 AH, SOC: 98%, I: 0A, L:4086, l:4097, H:4090, B:004, PT:016C, BT:028C, PV:114476, M:Bike On 01008 11/29/2025 06:06:33 SOC:1923,72461,5740,114800,95,97,98,11 01009 11/29/2025 06:06:36 DEBUG: CAN Receiving Syncs 01010 11/29/2025 06:06:41 Contactor drive turned on Pack V: 114457mV, Switched V: 101139mV, Duty Cycle: 35% 01011 11/29/2025 06:06:41 Contactor was Closed Pack V: 114457mV, Switched V: 101139mV, Prechg Pct: 88%, Dischg Cur: 545mA 01012 11/29/2025 06:07:33 Discharge level 005 AH, SOC: 98%, I: 1A, L:4084, l:4091, H:4089, B:005, PT:016C, BT:027C, PV:114442, M:Bike On 01013 11/29/2025 06:07:33 SOC:1945,72406,5755,114800,95,97,98,7 01014 11/29/2025 06:08:33 Discharge level 005 AH, SOC: 98%, I: 1A, L:4084, l:4089, H:4089, B:005, PT:016C, BT:026C, PV:114442, M:Bike On 01015 11/29/2025 06:08:33 SOC:1962,72356,5769,114800,95,97,98,5 01016 11/29/2025 06:09:33 Discharge level 005 AH, SOC: 98%, I: 21A, L:4036, l:4059, H:4046, B:010, PT:016C, BT:025C, PV:113164, M:Bike On 01017 11/29/2025 06:09:33 SOC:2106,71948,5928,114800,95,94,98,23 01018 11/29/2025 06:10:33 Discharge level 006 AH, SOC: 97%, I:-12A, L:4090, l:4090, H:4094, B:004, PT:016C, BT:025C, PV:114562, M:Bike On 01019 11/29/2025 06:10:33 SOC:2187,71656,6009,114800,95,97,97,0 01020 11/29/2025 06:11:33 Discharge level 006 AH, SOC: 97%, I:-18A, L:4089, l:4097, H:4093, B:004, PT:017C, BT:025C, PV:114553, M:Bike On 01021 11/29/2025 06:11:33 SOC:2542,70855,6389,114800,95,97,97,8 01022 11/29/2025 06:12:33 Discharge level 007 AH, SOC: 96%, I: 0A, L:3989, l:4033, H:4006, B:017, PT:017C, BT:024C, PV:111967, M:Bike On 01023 11/29/2025 06:12:33 SOC:3182,69676,7036,114800,94,91,96,43 01024 11/29/2025 06:13:33 Discharge level 007 AH, SOC: 95%, I: 87A, L:3799, l:3917, H:3843, B:044, PT:017C, BT:024C, PV:107053, M:Bike On 01025 11/29/2025 06:13:33 SOC:3993,68309,7894,114800,94,81,95,115 01026 11/29/2025 06:14:33 Discharge level 008 AH, SOC: 93%, I: 1A, L:3996, l:4048, H:4008, B:012, PT:017C, BT:024C, PV:112089, M:Bike On 01027 11/29/2025 06:14:33 SOC:4724,67103,8667,114800,93,93,93,50 01028 11/29/2025 06:15:33 Discharge level 008 AH, SOC: 93%, I:-12A, L:4040, l:4059, H:4047, B:007, PT:017C, BT:023C, PV:113263, M:Bike On 01029 11/29/2025 06:15:33 SOC:4950,66616,8919,114800,93,94,93,19 01030 11/29/2025 06:16:33 Discharge level 009 AH, SOC: 93%, I: 12A, L:4002, l:4026, H:4014, B:012, PT:017C, BT:024C, PV:112270, M:Bike On 01031 11/29/2025 06:16:33 SOC:5126,66284,9102,114800,93,90,93,24 01032 11/29/2025 06:17:33 Discharge level 009 AH, SOC: 93%, I: 15A, L:4015, l:4036, H:4025, B:010, PT:018C, BT:024C, PV:112596, M:Bike On 01033 11/29/2025 06:17:33 SOC:5218,66091,9196,114800,92,91,93,21 01034 11/29/2025 06:18:33 Discharge level 009 AH, SOC: 92%, I:113A, L:3782, l:3883, H:3825, B:043, PT:018C, BT:024C, PV:106513, M:Bike On 01035 11/29/2025 06:18:33 SOC:5428,65776,9419,114800,92,77,92,102 01036 11/29/2025 06:19:33 Discharge level 009 AH, SOC: 91%, I: 1A, L:3974, l:4007, H:3990, B:016, PT:018C, BT:023C, PV:111564, M:Bike On 01037 11/29/2025 06:19:33 SOC:5864,65142,9871,114800,92,89,91,34 01038 11/29/2025 06:20:33 Discharge level 010 AH, SOC: 91%, I: 5A, L:4006, l:4029, H:4015, B:009, PT:018C, BT:024C, PV:112337, M:Bike On 01039 11/29/2025 06:20:33 SOC:6083,64852,10098,114800,92,91,91,24 01040 11/29/2025 06:21:33 Discharge level 011 AH, SOC: 90%, I: 1A, L:3941, l:4032, H:3956, B:015, PT:018C, BT:024C, PV:110590, M:Bike On 01041 11/29/2025 06:21:33 SOC:6980,63850,11013,114800,91,91,90,91 01042 11/29/2025 06:21:33 Discharge cutback 86% 01043 11/29/2025 06:21:33 742A 01044 11/29/2025 06:22:33 Discharge level 012 AH, SOC: 87%, I:102A, L:3770, l:3903, H:3808, B:038, PT:019C, BT:023C, PV:106133, M:Bike On 01045 11/29/2025 06:22:33 SOC:8199,62642,12345,114800,90,78,87,131 01046 11/29/2025 06:23:33 Discharge level 013 AH, SOC: 85%, I:135A, L:3730, l:3888, H:3773, B:043, PT:019C, BT:024C, PV:105105, M:Bike On 01047 11/29/2025 06:23:33 SOC:9500,61509,13736,114800,89,78,85,165 01048 11/29/2025 06:24:33 Discharge level 014 AH, SOC: 83%, I:137A, L:3699, l:3852, H:3747, B:048, PT:020C, BT:024C, PV:104303, M:Bike On 01049 11/29/2025 06:24:33 SOC:10331,60660,14760,114800,88,73,83,158 01050 11/29/2025 06:25:33 Discharge level 015 AH, SOC: 82%, I:101A, L:3749, l:3874, H:3790, B:041, PT:020C, BT:024C, PV:105623, M:Bike On 01051 11/29/2025 06:25:33 SOC:10962,59914,15622,114800,87,77,82,138 01052 11/29/2025 06:26:33 Discharge level 017 AH, SOC: 79%, I:183A, L:3602, l:3805, H:3662, B:060, PT:021C, BT:024C, PV:101806, M:Bike On 01053 11/29/2025 06:26:33 SOC:12448,58866,17285,114800,85,68,79,222 01054 11/29/2025 06:27:33 Discharge level 018 AH, SOC: 77%, I: 99A, L:3746, l:3887, H:3782, B:036, PT:022C, BT:024C, PV:105488, M:Bike On 01055 11/29/2025 06:27:33 SOC:13549,58213,18575,114800,84,78,77,165 01056 11/29/2025 06:28:33 Discharge level 020 AH, SOC: 75%, I:105A, L:3718, l:3847, H:3758, B:040, PT:022C, BT:023C, PV:104798, M:Bike On 01057 11/29/2025 06:28:33 SOC:14773,57433,20096,114800,83,74,75,155 01058 11/29/2025 06:29:33 Discharge level 020 AH, SOC: 74%, I: 1A, L:3854, l:3902, H:3872, B:018, PT:023C, BT:024C, PV:108247, M:Bike On 01059 11/29/2025 06:29:33 SOC:15320,57309,20886,114800,82,79,74,57 01060 11/29/2025 06:30:33 Discharge level 021 AH, SOC: 74%, I:-18A, L:3893, l:3923, H:3904, B:011, PT:023C, BT:024C, PV:109236, M:Bike On 01061 11/29/2025 06:30:33 SOC:15480,57825,21148,114800,82,81,74,36 01062 11/29/2025 06:31:33 Discharge level 022 AH, SOC: 73%, I: 1A, L:3855, l:3901, H:3869, B:014, PT:024C, BT:024C, PV:108233, M:Bike On 01063 11/29/2025 06:31:33 SOC:16084,57570,22060,114800,81,79,73,57 01064 11/29/2025 06:32:33 Discharge level 022 AH, SOC: 72%, I: 1A, L:3711, l:3813, H:3749, B:038, PT:024C, BT:025C, PV:104634, M:Bike On 01065 11/29/2025 06:32:33 SOC:16610,57488,22824,114800,81,70,72,126 01066 11/29/2025 06:32:33 Discharge cutback 88% 01067 11/29/2025 06:32:33 759A 01068 11/29/2025 06:33:33 Discharge level 024 AH, SOC: 70%, I: 0A, L:3800, l:3880, H:3820, B:020, PT:024C, BT:025C, PV:106804, M:Bike On 01069 11/29/2025 06:33:33 SOC:17606,57251,24064,114800,80,77,70,99 01070 11/29/2025 06:34:33 Discharge level 025 AH, SOC: 68%, I: 81A, L:3703, l:3798, H:3741, B:038, PT:025C, BT:024C, PV:104404, M:Bike On 01071 11/29/2025 06:34:33 SOC:18287,56958,25118,114800,79,69,68,121 01072 11/29/2025 06:35:33 Discharge level 025 AH, SOC: 68%, I: 0A, L:3810, l:3851, H:3827, B:017, PT:025C, BT:024C, PV:107040, M:Bike On 01073 11/29/2025 06:35:33 SOC:18774,57048,25869,114800,78,74,68,52 01074 11/29/2025 06:36:33 Discharge level 026 AH, SOC: 68%, I: 45A, L:3764, l:3829, H:3788, B:024, PT:025C, BT:025C, PV:105863, M:Bike On 01075 11/29/2025 06:36:33 SOC:18722,57056,26223,114800,78,72,68,83 01076 11/29/2025 06:37:33 Discharge level 026 AH, SOC: 67%, I:-30A, L:3853, l:3866, H:3862, B:009, PT:026C, BT:024C, PV:108028, M:Bike On 01077 11/29/2025 06:37:33 SOC:18903,56612,26939,114800,77,76,67,16 01078 11/29/2025 06:38:33 Discharge level 027 AH, SOC: 66%, I: 1A, L:3794, l:3832, H:3809, B:015, PT:026C, BT:025C, PV:106535, M:Bike On 01079 11/29/2025 06:38:33 SOC:19637,56547,27904,114800,76,72,66,50 01080 11/29/2025 06:39:33 Discharge level 028 AH, SOC: 66%, I: 1A, L:3788, l:3821, H:3804, B:016, PT:026C, BT:025C, PV:106404, M:Bike On 01081 11/29/2025 06:39:33 SOC:20001,57211,28330,114800,76,71,66,43 01082 11/29/2025 06:40:23 Contactor was Opened Pack V: 106915mV, Switched V: 106850mV, Prechg Pct: 100%, Dischg Cur: 1000mA 01083 11/29/2025 06:40:23 System Turned Off 01084 11/29/2025 06:40:24 DEBUG: CAN Link Is Down 01085 11/29/2025 06:40:24 DEBUG: Entered Idle State 01086 11/29/2025 06:40:30 Current Sensor Zeroed old: 2505mV, new: 2506mV, corrfact: 250 01087 11/29/2025 06:40:31 Discharge level 028 AH, SOC: 66%, I: 0A, L:3812, l:3830, H:3825, B:013, PT:026C, BT:026C, PV:106990, M:Idle 01088 11/29/2025 06:40:32 SOC:20002,57646,28508,114800,76,72,66,25 01089 11/29/2025 06:40:53 Voltage Across Contactor: 94187mV (Okay) 01090 11/29/2025 07:07:31 System Turned On 01091 11/29/2025 07:07:31 Rev:45,Build:2023-05-20_045619 958 banka 01092 11/29/2025 07:07:31 Pack:2019_monolith,Numbricks:4 01093 11/29/2025 07:07:31 DEBUG: Entered Running State 01094 11/29/2025 07:07:31 DEBUG: CAN NOT Receiving Syncs 01095 11/29/2025 07:07:31 DEBUG: CAN Link Is Up 01096 11/29/2025 07:07:32 DEBUG: Resetting CAN0 due to error passive mode 01097 11/29/2025 07:07:32 Discharge level 028 AH, SOC: 66%, I: 0A, L:3852, l:3870, H:3861, B:009, PT:026C, BT:027C, PV:107983, M:Bike On 01098 11/29/2025 07:07:32 SOC:19996,57646,28508,114800,76,76,66,24 01099 11/29/2025 07:07:35 DEBUG: CAN Receiving Syncs 01100 11/29/2025 07:07:35 Contactor drive turned on Pack V: 107968mV, Switched V: 94641mV, Duty Cycle: 37% 01101 11/29/2025 07:07:35 Contactor was Closed Pack V: 107968mV, Switched V: 94641mV, Prechg Pct: 88%, Dischg Cur: 636mA 01102 11/29/2025 07:08:32 Discharge level 028 AH, SOC: 67%, I: 0A, L:3851, l:3862, H:3860, B:009, PT:026C, BT:027C, PV:107965, M:Bike On 01103 11/29/2025 07:08:32 SOC:19841,58760,28520,114800,76,75,67,15 01104 11/29/2025 07:09:32 Discharge level 028 AH, SOC: 67%, I: 18A, L:3825, l:3845, H:3835, B:010, PT:026C, BT:027C, PV:107278, M:Bike On 01105 11/29/2025 07:09:32 SOC:19764,59588,28651,114800,76,74,67,27 01106 11/29/2025 07:10:32 Discharge level 028 AH, SOC: 68%, I: 44A, L:3794, l:3833, H:3806, B:012, PT:026C, BT:027C, PV:106442, M:Bike On 01107 11/29/2025 07:10:32 SOC:19599,59667,28916,114800,75,72,68,52 01108 11/29/2025 07:11:32 Discharge level 029 AH, SOC: 67%, I: 55A, L:3753, l:3812, H:3767, B:014, PT:026C, BT:027C, PV:105331, M:Bike On 01109 11/29/2025 07:11:32 SOC:20081,59921,29565,114800,75,70,67,78 01110 11/29/2025 07:12:32 Discharge level 031 AH, SOC: 64%, I: 0A, L:3740, l:3823, H:3752, B:012, PT:027C, BT:027C, PV:104962, M:Bike On 01111 11/29/2025 07:12:32 SOC:21905,59511,31465,114800,73,71,64,111 01112 11/29/2025 07:12:32 Discharge cutback 83% 01113 11/29/2025 07:12:32 715A 01114 11/29/2025 07:13:32 Discharge level 034 AH, SOC: 57%, I:156A, L:3493, l:3694, H:3551, B:058, PT:028C, BT:027C, PV: 98817, M:Bike On 01115 11/29/2025 07:13:32 SOC:25239,58567,34806,114800,70,55,57,285 01116 11/29/2025 07:13:32 Discharge cutback 77% 01117 11/29/2025 07:13:32 665A 01118 11/29/2025 07:14:32 Discharge level 036 AH, SOC: 55%, I: 99A, L:3593, l:3705, H:3632, B:039, PT:028C, BT:027C, PV:101319, M:Bike On 01119 11/29/2025 07:14:32 SOC:26483,58374,36358,114800,69,57,55,167 01120 11/29/2025 07:15:32 Discharge level 036 AH, SOC: 55%, I: 24A, L:3687, l:3740, H:3706, B:019, PT:029C, BT:027C, PV:103614, M:Bike On 01121 11/29/2025 07:15:32 SOC:26644,58617,36897,114800,68,62,55,79 01122 11/29/2025 07:16:32 Discharge level 037 AH, SOC: 55%, I:-40A, L:3751, l:3775, H:3757, B:006, PT:029C, BT:027C, PV:105128, M:Bike On 01123 11/29/2025 07:16:32 SOC:26669,58739,37379,114800,68,66,55,37 01124 11/29/2025 07:17:32 Discharge level 038 AH, SOC: 53%, I:377A, L:3329, l:3553, H:3427, B:098, PT:029C, BT:028C, PV: 94953, M:Bike On 01125 11/29/2025 07:17:32 SOC:27784,58496,38817,114800,67,30,53,351 01126 11/29/2025 07:17:32 Discharge cutback 85% 01127 11/29/2025 07:17:32 736A 01128 11/29/2025 07:18:32 Discharge level 040 AH, SOC: 50%, I:193A, L:3478, l:3617, H:3539, B:061, PT:029C, BT:028C, PV: 98492, M:Bike On 01129 11/29/2025 07:18:32 SOC:29065,58123,40389,114800,65,43,50,221 01130 11/29/2025 07:18:32 Discharge cutback 82% 01131 11/29/2025 07:18:32 702A 01132 11/29/2025 07:19:32 Discharge level 041 AH, SOC: 50%, I:-19A, L:3691, l:3724, H:3703, B:012, PT:030C, BT:028C, PV:103600, M:Bike On 01133 11/29/2025 07:19:32 SOC:29346,57710,41240,114800,65,60,50,52 01134 11/29/2025 07:19:32 Discharge cutback 82% 01135 11/29/2025 07:19:32 705A 01136 11/29/2025 07:20:32 Discharge level 042 AH, SOC: 48%, I:-26A, L:3679, l:3720, H:3691, B:012, PT:030C, BT:028C, PV:103271, M:Bike On 01137 11/29/2025 07:20:32 SOC:30015,57364,42371,114800,64,60,48,66 01138 11/29/2025 07:20:32 Discharge cutback 83% 01139 11/29/2025 07:20:32 712A 01140 11/29/2025 07:21:32 Discharge level 043 AH, SOC: 47%, I: 41A, L:3627, l:3685, H:3650, B:023, PT:030C, BT:027C, PV:102022, M:Bike On 01141 11/29/2025 07:21:32 SOC:30264,56852,43252,114800,63,55,47,93 01142 11/29/2025 07:21:32 Discharge cutback 84% 01143 11/29/2025 07:21:32 725A 01144 11/29/2025 07:22:32 Discharge level 044 AH, SOC: 46%, I: 58A, L:3595, l:3658, H:3625, B:030, PT:030C, BT:028C, PV:101262, M:Bike On 01145 11/29/2025 07:22:32 SOC:30748,56256,44312,114800,62,51,46,106 01146 11/29/2025 07:22:32 Discharge cutback 81% 01147 11/29/2025 07:22:32 695A 01148 11/29/2025 07:23:32 Discharge level 044 AH, SOC: 46%, I: 20A, L:3650, l:3684, H:3666, B:016, PT:030C, BT:027C, PV:102546, M:Bike On 01149 11/29/2025 07:23:32 SOC:30511,56130,44686,114800,62,55,46,57 01150 11/29/2025 07:23:32 Discharge cutback 87% 01151 11/29/2025 07:23:32 749A 01152 11/29/2025 07:24:32 Discharge level 045 AH, SOC: 46%, I: 1A, L:3662, l:3685, H:3675, B:013, PT:030C, BT:028C, PV:102825, M:Bike On 01153 11/29/2025 07:24:32 SOC:30561,56242,45183,114800,61,55,46,39 01154 11/29/2025 07:24:32 Discharge cutback 89% 01155 11/29/2025 07:24:32 766A 01156 11/29/2025 07:24:45 Contactor was Opened Pack V: 102947mV, Switched V: 102872mV, Prechg Pct: 100%, Dischg Cur: 1000mA 01157 11/29/2025 07:24:46 System Turned Off 01158 11/29/2025 07:24:47 DEBUG: CAN Link Is Down 01159 11/29/2025 07:24:47 DEBUG: Entered Idle State 01160 11/29/2025 07:24:52 Current Sensor Zeroed old: 2506mV, new: 2504mV, corrfact: 252 01161 11/29/2025 07:24:54 Discharge level 045 AH, SOC: 46%, I: 0A, L:3669, l:3686, H:3682, B:013, PT:030C, BT:028C, PV:103020, M:Idle 01162 11/29/2025 07:24:54 SOC:30553,56551,45187,114800,61,55,46,29 01163 11/29/2025 07:25:15 Voltage Across Contactor: 90249mV (Okay) 01164 11/29/2025 07:41:13 System Turned On 01165 11/29/2025 07:41:13 Rev:45,Build:2023-05-20_045619 958 banka 01166 11/29/2025 07:41:13 Pack:2019_monolith,Numbricks:4 01167 11/29/2025 07:41:13 DEBUG: Entered Running State 01168 11/29/2025 07:41:13 DEBUG: CAN NOT Receiving Syncs 01169 11/29/2025 07:41:14 DEBUG: CAN Link Is Up 01170 11/29/2025 07:41:14 DEBUG: Resetting CAN0 due to error passive mode 01171 11/29/2025 07:41:14 Discharge level 045 AH, SOC: 46%, I: 0A, L:3697, l:3715, H:3704, B:007, PT:030C, BT:028C, PV:103658, M:Bike On 01172 11/29/2025 07:41:14 SOC:30545,56551,45187,114800,61,59,46,29 01173 11/29/2025 07:41:17 DEBUG: CAN Receiving Syncs 01174 11/29/2025 07:41:22 Contactor drive turned on Pack V: 103650mV, Switched V: 91766mV, Duty Cycle: 38% 01175 11/29/2025 07:41:22 Contactor was Closed Pack V: 103650mV, Switched V: 91766mV, Prechg Pct: 89%, Dischg Cur: 1091mA 01176 11/29/2025 07:42:14 Discharge level 045 AH, SOC: 48%, I: 1A, L:3696, l:3708, H:3703, B:007, PT:030C, BT:028C, PV:103634, M:Bike On 01177 11/29/2025 07:42:14 SOC:30555,58351,45216,114800,61,58,48,19 01178 11/29/2025 07:43:14 Discharge level 045 AH, SOC: 49%, I: 1A, L:3696, l:3704, H:3703, B:007, PT:030C, BT:028C, PV:103630, M:Bike On 01179 11/29/2025 07:43:14 SOC:30583,59919,45245,114800,61,58,49,14 01180 11/29/2025 07:44:14 Discharge level 045 AH, SOC: 51%, I: 1A, L:3698, l:3704, H:3705, B:007, PT:030C, BT:029C, PV:103655, M:Bike On 01181 11/29/2025 07:44:14 SOC:30575,61240,45268,114800,61,58,51,10 01182 11/29/2025 07:45:14 Discharge level 046 AH, SOC: 49%, I:236A, L:3436, l:3580, H:3499, B:063, PT:030C, BT:029C, PV: 97321, M:Bike On 01183 11/29/2025 07:45:14 SOC:31555,61475,46303,114800,60,35,49,230 01184 11/29/2025 07:45:14 Discharge cutback 80% 01185 11/29/2025 07:45:14 685A 01186 11/29/2025 07:46:14 Discharge level 047 AH, SOC: 47%, I:-22A, L:3655, l:3691, H:3665, B:010, PT:030C, BT:029C, PV:102537, M:Bike On 01187 11/29/2025 07:46:14 SOC:32667,60937,47671,114800,59,56,47,58 01188 11/29/2025 07:46:14 Discharge cutback 78% 01189 11/29/2025 07:46:14 668A 01190 11/29/2025 07:47:14 Discharge level 049 AH, SOC: 44%, I:180A, L:3428, l:3574, H:3487, B:059, PT:030C, BT:029C, PV: 97069, M:Bike On 01191 11/29/2025 07:47:14 SOC:34207,60232,49350,114800,58,34,44,246 01192 11/29/2025 07:47:14 Discharge cutback 68% 01193 11/29/2025 07:47:15 587A 01194 11/29/2025 07:48:14 Discharge level 051 AH, SOC: 39%, I: 67A, L:3514, l:3612, H:3550, B:036, PT:031C, BT:029C, PV: 99102, M:Bike On 01195 11/29/2025 07:48:14 SOC:36679,59221,51842,114800,55,42,39,166 01196 11/29/2025 07:48:14 Discharge cutback 64% 01197 11/29/2025 07:48:15 550A 01198 11/29/2025 07:49:14 Discharge level 054 AH, SOC: 32%, I:247A, L:3286, l:3508, H:3373, B:087, PT:032C, BT:029C, PV: 93624, M:Bike On 01199 11/29/2025 07:49:14 SOC:39524,58000,54706,114800,53,12,32,368 01200 11/29/2025 07:49:14 Discharge cutback 44% 01201 11/29/2025 07:49:15 381A 01202 11/29/2025 07:50:14 Discharge level 055 AH, SOC: 32%, I: 1A, L:3559, l:3625, H:3585, B:026, PT:032C, BT:029C, PV:100200, M:Bike On 01203 11/29/2025 07:50:14 SOC:40176,58643,55617,114800,52,45,32,115 01204 11/29/2025 07:50:15 Discharge cutback 66% 01205 11/29/2025 07:50:15 567A 01206 11/29/2025 07:51:14 Discharge level 055 AH, SOC: 34%, I: 1A, L:3602, l:3633, H:3620, B:018, PT:032C, BT:029C, PV:101256, M:Bike On 01207 11/29/2025 07:51:14 SOC:39934,60154,55673,114800,52,47,34,54 01208 11/29/2025 07:51:15 Discharge cutback 78% 01209 11/29/2025 07:51:15 668A 01210 11/29/2025 07:52:14 Discharge level 056 AH, SOC: 34%, I:149A, L:3446, l:3551, H:3502, B:056, PT:032C, BT:030C, PV: 97573, M:Bike On 01211 11/29/2025 07:52:14 SOC:40813,61084,56675,114800,51,28,34,183 01212 11/29/2025 07:52:15 Discharge cutback 71% 01213 11/29/2025 07:52:15 607A 01214 11/29/2025 07:53:14 Discharge level 057 AH, SOC: 34%, I: -4A, L:3595, l:3628, H:3613, B:018, PT:032C, BT:030C, PV:101049, M:Bike On 01215 11/29/2025 07:53:15 SOC:40951,61569,57245,114800,51,46,34,57 01216 11/29/2025 07:53:15 Discharge cutback 73% 01217 11/29/2025 07:53:15 631A 01218 11/29/2025 07:54:14 Discharge level 057 AH, SOC: 35%, I: 1A, L:3605, l:3625, H:3621, B:016, PT:032C, BT:030C, PV:101315, M:Bike On 01219 11/29/2025 07:54:15 SOC:40880,62728,57437,114800,50,46,35,35 01220 11/29/2025 07:54:15 Discharge cutback 79% 01221 11/29/2025 07:54:15 682A 01222 11/29/2025 07:55:14 Discharge level 057 AH, SOC: 37%, I: 1A, L:3615, l:3629, H:3629, B:014, PT:032C, BT:028C, PV:101538, M:Bike On 01223 11/29/2025 07:55:15 SOC:40899,64492,57464,114800,50,46,37,24 01224 11/29/2025 07:55:15 Discharge cutback 82% 01225 11/29/2025 07:55:15 705A 01226 11/29/2025 07:55:29 Contactor was Opened Pack V: 101574mV, Switched V: 101454mV, Prechg Pct: 100%, Dischg Cur: 909mA 01227 11/29/2025 07:55:29 System Turned Off 01228 11/29/2025 07:55:30 DEBUG: CAN Link Is Down 01229 11/29/2025 07:55:30 DEBUG: Entered Idle State 01230 11/29/2025 07:55:37 Discharge level 057 AH, SOC: 37%, I: 0A, L:3618, l:3630, H:3632, B:014, PT:032C, BT:030C, PV:101607, M:Idle 01231 11/29/2025 07:55:37 SOC:40884,64862,57469,114800,50,46,37,21 01232 11/29/2025 07:55:59 Voltage Across Contactor: 88737mV (Okay) 01233 11/30/2025 03:53:32 System Turned On 01234 11/30/2025 03:53:32 Rev:45,Build:2023-05-20_045619 958 banka 01235 11/30/2025 03:53:32 Pack:2019_monolith,Numbricks:4 01236 11/30/2025 03:53:32 DEBUG: Entered Running State 01237 11/30/2025 03:53:32 DEBUG: CAN NOT Receiving Syncs 01238 11/30/2025 03:53:33 DEBUG: CAN Link Is Up 01239 11/30/2025 03:53:33 DEBUG: Resetting CAN0 due to error passive mode 01240 11/30/2025 03:53:34 Discharge level 057 AH, SOC: 37%, I: 0A, L:3644, l:3668, H:3652, B:008, PT:015C, BT:020C, PV:102188, M:Bike On 01241 11/30/2025 03:53:34 SOC:40873,64862,57469,114800,50,53,37,21 01242 11/30/2025 03:53:34 Discharge cutback 88% 01243 11/30/2025 03:53:34 759A 01244 11/30/2025 03:53:37 DEBUG: CAN Receiving Syncs 01245 11/30/2025 03:53:41 Contactor drive turned on Pack V: 102172mV, Switched V: 90427mV, Duty Cycle: 39% 01246 11/30/2025 03:53:41 Contactor was Closed Pack V: 102172mV, Switched V: 90427mV, Prechg Pct: 89%, Dischg Cur: 545mA 01247 11/30/2025 03:53:55 DEBUG: Entered Charging State 01248 11/30/2025 03:53:55 DEBUG: CAN NOT Receiving Syncs 01249 11/30/2025 03:53:56 Discharge level 057 AH, SOC: 38%, I: 0A, L:3643, l:3665, H:3651, B:008, PT:015C, BT:020C, PV:102170, M:Charge 01250 11/30/2025 03:53:56 SOC:40548,64878,57469,114800,50,52,38,19 01251 11/30/2025 03:53:56 DEBUG: CAN Link Is Down 01252 11/30/2025 03:53:56 Contactor was Opened Pack V: 102170mV, Switched V: 102163mV, Prechg Pct: 100%, Dischg Cur: 818mA 01253 11/30/2025 03:53:56 DEBUG: CAN Link Is Up 01254 11/30/2025 03:53:56 DEBUG: CAN Receiving Syncs 01255 11/30/2025 03:53:58 DEBUG: Entered Running State 01256 11/30/2025 03:53:58 DEBUG: CAN NOT Receiving Syncs 01257 11/30/2025 03:53:59 Discharge level 057 AH, SOC: 38%, I: 0A, L:3643, l:3664, H:3652, B:009, PT:015C, BT:020C, PV:102175, M:Bike On 01258 11/30/2025 03:53:59 SOC:40531,64878,57469,114800,50,52,38,19 01259 11/30/2025 03:53:59 Discharge cutback 88% 01260 11/30/2025 03:53:59 759A 01261 11/30/2025 03:54:00 DEBUG: CAN Receiving Syncs 01262 11/30/2025 03:54:00 Contactor drive turned on Pack V: 102172mV, Switched V: 89718mV, Duty Cycle: 39% 01263 11/30/2025 03:54:00 Contactor was Closed Pack V: 102172mV, Switched V: 89718mV, Prechg Pct: 88%, Dischg Cur: 363mA 01264 11/30/2025 03:54:02 Contactor was Opened Pack V: 102171mV, Switched V: 102163mV, Prechg Pct: 100%, Dischg Cur: 818mA 01265 11/30/2025 03:54:03 System Turned Off 01266 11/30/2025 03:54:03 DEBUG: CAN Link Is Down 01267 11/30/2025 03:54:03 DEBUG: Entered Idle State 01268 11/30/2025 03:54:04 System Turned On 01269 11/30/2025 03:54:04 Rev:45,Build:2023-05-20_045619 958 banka 01270 11/30/2025 03:54:04 Pack:2019_monolith,Numbricks:4 01271 11/30/2025 03:54:04 DEBUG: Entered Running State 01272 11/30/2025 03:54:04 DEBUG: CAN NOT Receiving Syncs 01273 11/30/2025 03:54:05 DEBUG: CAN Link Is Up 01274 11/30/2025 03:54:05 DEBUG: Resetting CAN0 due to error passive mode 01275 11/30/2025 03:54:06 DEBUG: CAN Receiving Syncs 01276 11/30/2025 03:54:07 DEBUG: CAN NOT Receiving Syncs 01277 11/30/2025 03:54:09 DEBUG: CAN Receiving Syncs 01278 11/30/2025 03:54:09 Contactor drive turned on Pack V: 102164mV, Switched V: 90466mV, Duty Cycle: 39% 01279 11/30/2025 03:54:09 Contactor was Closed Pack V: 102164mV, Switched V: 90466mV, Prechg Pct: 89%, Dischg Cur: 545mA 01280 11/30/2025 03:54:11 DEBUG: Entered Charging State 01281 11/30/2025 03:54:11 DEBUG: CAN NOT Receiving Syncs 01282 11/30/2025 03:54:12 Discharge level 057 AH, SOC: 38%, I: 0A, L:3643, l:3663, H:3651, B:008, PT:015C, BT:020C, PV:102168, M:Charge 01283 11/30/2025 03:54:12 SOC:40368,64888,57469,114800,50,52,38,18 01284 11/30/2025 03:54:13 DEBUG: CAN Receiving Syncs 01285 11/30/2025 04:04:12 Discharge level 052 AH, SOC: 57%, I:-31A, L:3764, l:3700, H:3779, B:015, PT:016C, BT:030C, PV:105607, M:Charge 01286 11/30/2025 04:04:12 SOC:23377,53252,52212,114800,55,57,57,-56 01287 11/30/2025 04:14:12 Discharge level 046 AH, SOC: 64%, I:-32A, L:3796, l:3730, H:3816, B:020, PT:017C, BT:034C, PV:106538, M:Charge 01288 11/30/2025 04:14:12 SOC:19861,55038,46921,114800,60,61,64,-60 01289 11/30/2025 04:24:12 Discharge level 041 AH, SOC: 70%, I:-31A, L:3838, l:3776, H:3859, B:021, PT:018C, BT:035C, PV:107725, M:Charge 01290 11/30/2025 04:24:12 SOC:18142,58532,41721,114800,64,66,70,-59 01291 11/30/2025 04:34:20 Discharge level 036 AH, SOC: 75%, I:-30A, L:3888, l:3831, H:3910, B:022, PT:019C, BT:037C, PV:109143, M:Charge 01292 11/30/2025 04:34:20 SOC:16014,61672,36467,114800,69,72,75,-58 01293 11/30/2025 04:44:20 Discharge level 031 AH, SOC: 80%, I:-30A, L:3941, l:3889, H:3959, B:018, PT:021C, BT:037C, PV:110591, M:Charge 01294 11/30/2025 04:44:20 SOC:13174,63936,31376,114800,73,78,80,-57 01295 11/30/2025 04:54:20 Discharge level 026 AH, SOC: 85%, I:-28A, L:3991, l:3945, H:4006, B:015, PT:021C, BT:037C, PV:111939, M:Charge 01296 11/30/2025 04:54:20 SOC:10253,65987,26420,114800,77,83,85,-55 01297 11/30/2025 05:02:18 Charged To Full 022 AH, SOC: 89%, L:4029, H:4044, B:015, PT:022C, BT:038C, PV:112747 01298 11/30/2025 05:02:18 SOC adjusted for voltage old: 8093574uAH (soc:89%), new: 6095653uAH (soc:91%), low cell: 4029 mV 01299 11/30/2025 05:04:20 Discharge level 009 AH, SOC: 91%, I:-29A, L:4041, l:3997, H:4056, B:015, PT:022C, BT:039C, PV:113320, M:Charge 01300 11/30/2025 05:04:20 SOC:6367,69006,9330,114800,92,88,91,-55 01301 11/30/2025 05:09:16 DEBUG: Entered Standby State 01302 11/30/2025 05:09:16 DEBUG: CAN NOT Receiving Syncs 01303 11/30/2025 05:09:17 System Turned Off 01304 11/30/2025 05:09:17 DEBUG: CAN Link Is Down 01305 11/30/2025 05:09:18 DEBUG: CAN Receiving Syncs 01306 11/30/2025 05:09:18 DEBUG: Entered Idle State 01307 11/30/2025 05:09:18 Contactor was Opened Pack V: 112844mV, Switched V: 112758mV, Prechg Pct: 100%, Dischg Cur: 818mA 01308 11/30/2025 05:09:23 Current Sensor Zeroed old: 2504mV, new: 2508mV, corrfact: 248 01309 11/30/2025 05:09:24 System Turned On 01310 11/30/2025 05:09:24 Rev:45,Build:2023-05-20_045619 958 banka 01311 11/30/2025 05:09:24 Pack:2019_monolith,Numbricks:4 01312 11/30/2025 05:09:24 SOC adjusted for voltage old: 5892952uAH (soc:92%), new: 7094278uAH (soc:90%), low cell: 4024 mV 01313 11/30/2025 05:09:24 DEBUG: Entered Standby State 01314 11/30/2025 05:09:24 DEBUG: CAN NOT Receiving Syncs 01315 11/30/2025 05:09:25 DEBUG: Entered Running State 01316 11/30/2025 05:09:25 DEBUG: CAN Link Is Up 01317 11/30/2025 05:09:26 Discharge level 011 AH, SOC: 90%, I: 0A, L:4023, l:4001, H:4028, B:005, PT:022C, BT:039C, PV:112702, M:Bike On 01318 11/30/2025 05:09:26 SOC:7096,70942,11480,114800,90,88,90,-28 01319 11/30/2025 05:09:27 DEBUG: CAN Receiving Syncs 01320 11/30/2025 05:09:27 Contactor drive turned on Pack V: 112686mV, Switched V: 99918mV, Duty Cycle: 35% 01321 11/30/2025 05:09:27 Contactor was Closed Pack V: 112686mV, Switched V: 99918mV, Prechg Pct: 89%, Dischg Cur: 454mA 01322 11/30/2025 05:10:07 Contactor was Opened Pack V: 112407mV, Switched V: 112324mV, Prechg Pct: 100%, Dischg Cur: 454mA 01323 11/30/2025 05:10:07 System Turned Off 01324 11/30/2025 05:10:08 DEBUG: CAN Link Is Down 01325 11/30/2025 05:10:08 DEBUG: Entered Idle State 01326 11/30/2025 05:10:14 Current Sensor Zeroed old: 2508mV, new: 2504mV, corrfact: 252 01327 11/30/2025 05:10:15 Discharge level 011 AH, SOC: 90%, I: 0A, L:4013, l:4003, H:4016, B:003, PT:022C, BT:036C, PV:112285, M:Idle 01328 11/30/2025 05:10:15 SOC:7188,70926,11483,114800,90,88,90,-13 01329 11/30/2025 05:10:36 Voltage Across Contactor: 99447mV (Okay) 01330 11/30/2025 08:24:26 System Turned On 01331 11/30/2025 08:24:26 Rev:45,Build:2023-05-20_045619 958 banka 01332 11/30/2025 08:24:26 Pack:2019_monolith,Numbricks:4 01333 11/30/2025 08:24:27 DEBUG: Entered Running State 01334 11/30/2025 08:24:27 DEBUG: CAN NOT Receiving Syncs 01335 11/30/2025 08:24:27 DEBUG: CAN Link Is Up 01336 11/30/2025 08:24:27 DEBUG: Resetting CAN0 due to error passive mode 01337 11/30/2025 08:24:28 Discharge level 011 AH, SOC: 90%, I: 0A, L:3974, l:3963, H:3979, B:005, PT:021C, BT:034C, PV:111370, M:Bike On 01338 11/30/2025 08:24:28 SOC:7192,70926,11483,114800,90,85,90,-13 01339 11/30/2025 08:24:31 DEBUG: CAN Receiving Syncs 01340 11/30/2025 08:24:31 Contactor drive turned on Pack V: 111348mV, Switched V: 97476mV, Duty Cycle: 36% 01341 11/30/2025 08:24:31 Contactor was Closed Pack V: 111348mV, Switched V: 97476mV, Prechg Pct: 88%, Dischg Cur: 636mA 01342 11/30/2025 08:25:28 Discharge level 011 AH, SOC: 90%, I: 1A, L:3969, l:3967, H:3974, B:005, PT:021C, BT:034C, PV:111236, M:Bike On 01343 11/30/2025 08:25:28 SOC:7429,70485,11535,114800,90,85,90,-2 01344 11/30/2025 08:25:34 Contactor was Opened Pack V: 111297mV, Switched V: 111222mV, Prechg Pct: 100%, Dischg Cur: 1091mA 01345 11/30/2025 08:25:35 System Turned Off 01346 11/30/2025 08:25:35 DEBUG: CAN Link Is Down 01347 11/30/2025 08:25:35 DEBUG: Entered Idle State 01348 11/30/2025 08:25:41 Current Sensor Zeroed old: 2504mV, new: 2507mV, corrfact: 249 01349 11/30/2025 08:25:42 SOC adjusted for voltage old: 7439410uAH (soc:90%), new: 9859273uAH (soc:86%), low cell: 3973 mV 01350 11/30/2025 08:25:43 Discharge level 016 AH, SOC: 86%, I: 0A, L:3972, l:3968, H:3977, B:005, PT:021C, BT:033C, PV:111273, M:Idle 01351 11/30/2025 08:25:43 SOC:9859,70423,16072,114800,86,85,86,-5 01352 11/30/2025 08:26:04 Voltage Across Contactor: 98499mV (Okay) 01353 11/30/2025 09:17:49 DEBUG: Adjusted System time sec from 11/30/2025 09:18:48 (1764519528) to 11/30/2025 09:17:49 (1764519469) 01354 11/30/2025 10:05:45 System Turned On 01355 11/30/2025 10:05:45 Rev:45,Build:2023-05-20_045619 958 banka 01356 11/30/2025 10:05:46 Pack:2019_monolith,Numbricks:4 01357 11/30/2025 10:05:46 DEBUG: Entered Running State 01358 11/30/2025 10:05:46 DEBUG: CAN NOT Receiving Syncs 01359 11/30/2025 10:05:46 DEBUG: CAN Link Is Up 01360 11/30/2025 10:05:47 DEBUG: Resetting CAN0 due to error passive mode 01361 11/30/2025 10:05:47 Discharge level 016 AH, SOC: 90%, I: 0A, L:3971, l:3967, H:3975, B:004, PT:020C, BT:033C, PV:111289, M:Bike On 01362 11/30/2025 10:05:47 SOC:7442,70423,16072,114800,86,85,90,-5 01363 11/30/2025 10:05:50 DEBUG: CAN Receiving Syncs 01364 11/30/2025 10:05:50 Contactor drive turned on Pack V: 111265mV, Switched V: 97555mV, Duty Cycle: 36% 01365 11/30/2025 10:05:50 Contactor was Closed Pack V: 111265mV, Switched V: 97555mV, Prechg Pct: 88%, Dischg Cur: 636mA 01366 11/30/2025 10:06:47 Discharge level 016 AH, SOC: 90%, I: 0A, L:3970, l:3967, H:3974, B:004, PT:020C, BT:032C, PV:111261, M:Bike On 01367 11/30/2025 10:06:47 SOC:7736,70420,16072,114800,86,85,90,-3 01368 11/30/2025 10:07:47 Discharge level 016 AH, SOC: 89%, I: 46A, L:3889, l:3926, H:3904, B:015, PT:020C, BT:031C, PV:109152, M:Bike On 01369 11/30/2025 10:07:47 SOC:8132,70024,16259,114800,86,81,89,39 01370 11/30/2025 10:08:47 Discharge level 016 AH, SOC: 88%, I: 46A, L:3864, l:3913, H:3884, B:020, PT:020C, BT:030C, PV:108523, M:Bike On 01371 11/30/2025 10:08:47 SOC:8708,69329,16670,114800,86,80,88,52 01372 11/30/2025 10:09:47 Discharge level 016 AH, SOC: 87%, I: -9A, L:3961, l:3967, H:3967, B:006, PT:020C, BT:029C, PV:111027, M:Bike On 01373 11/30/2025 10:09:47 SOC:9111,68758,16950,114800,86,85,87,6 01374 11/30/2025 10:10:47 Discharge level 016 AH, SOC: 87%, I: 0A, L:3949, l:3954, H:3956, B:007, PT:020C, BT:029C, PV:110718, M:Bike On 01375 11/30/2025 10:10:47 SOC:9259,68517,16979,114800,86,84,87,6 01376 11/30/2025 10:11:47 Discharge level 017 AH, SOC: 86%, I: 67A, L:3784, l:3859, H:3813, B:029, PT:020C, BT:027C, PV:106404, M:Bike On 01377 11/30/2025 10:11:47 SOC:9868,67607,17533,114800,85,75,86,79 01378 11/30/2025 10:12:47 Discharge level 017 AH, SOC: 85%, I: 0A, L:3916, l:3945, H:3925, B:009, PT:020C, BT:027C, PV:109822, M:Bike On 01379 11/30/2025 10:12:47 SOC:10320,66937,17924,114800,85,83,85,30 01380 11/30/2025 10:13:47 Discharge level 018 AH, SOC: 85%, I: 0A, L:3925, l:3938, H:3934, B:009, PT:020C, BT:027C, PV:110075, M:Bike On 01381 11/30/2025 10:13:47 SOC:10575,66630,18095,114800,85,82,85,14 01382 11/30/2025 10:14:27 Contactor was Opened Pack V: 110207mV, Switched V: 110158mV, Prechg Pct: 100%, Dischg Cur: 545mA 01383 11/30/2025 10:14:27 System Turned Off 01384 11/30/2025 10:14:28 DEBUG: CAN Link Is Down 01385 11/30/2025 10:14:28 DEBUG: Entered Idle State 01386 11/30/2025 10:14:34 Current Sensor Zeroed old: 2507mV, new: 2504mV, corrfact: 252 01387 11/30/2025 10:14:34 SOC adjusted for voltage old: 10671036uAH (soc:84%), new: 11988736uAH (soc:82%), low cell: 3932 mV 01388 11/30/2025 10:14:35 Discharge level 020 AH, SOC: 82%, I: 0A, L:3932, l:3940, H:3940, B:008, PT:020C, BT:026C, PV:110165, M:Idle 01389 11/30/2025 10:14:35 SOC:11988,66604,20664,114800,82,83,82,8 01390 11/30/2025 10:14:57 Voltage Across Contactor: 97077mV (Okay) 01391 11/30/2025 10:16:16 System Turned On 01392 11/30/2025 10:16:16 Rev:45,Build:2023-05-20_045619 958 banka 01393 11/30/2025 10:16:16 Pack:2019_monolith,Numbricks:4 01394 11/30/2025 10:16:16 DEBUG: Entered Running State 01395 11/30/2025 10:16:16 DEBUG: CAN NOT Receiving Syncs 01396 11/30/2025 10:16:17 DEBUG: CAN Link Is Up 01397 11/30/2025 10:16:17 DEBUG: Resetting CAN0 due to error passive mode 01398 11/30/2025 10:16:18 Discharge level 020 AH, SOC: 84%, I: 0A, L:3937, l:3945, H:3945, B:008, PT:020C, BT:027C, PV:110393, M:Bike On 01399 11/30/2025 10:16:18 SOC:10671,66604,20664,114800,82,83,84,8 01400 11/30/2025 10:16:21 DEBUG: CAN Receiving Syncs 01401 11/30/2025 10:16:21 Contactor drive turned on Pack V: 110374mV, Switched V: 96768mV, Duty Cycle: 36% 01402 11/30/2025 10:16:21 Contactor was Closed Pack V: 110374mV, Switched V: 96768mV, Prechg Pct: 88%, Dischg Cur: 363mA 01403 11/30/2025 10:16:23 DEBUG: Entered Charging State 01404 11/30/2025 10:16:23 DEBUG: CAN NOT Receiving Syncs 01405 11/30/2025 10:16:24 Discharge level 020 AH, SOC: 84%, I: 0A, L:3937, l:3945, H:3945, B:008, PT:020C, BT:027C, PV:110383, M:Charge 01406 11/30/2025 10:16:24 SOC:10677,66603,20664,114800,82,83,84,8 01407 11/30/2025 10:16:24 DEBUG: CAN Receiving Syncs 01408 11/30/2025 10:19:09 Charged To Full 019 AH, SOC: 87%, L:4030, H:4041, B:011, PT:020C, BT:030C, PV:112752 01409 11/30/2025 10:19:09 SOC adjusted for voltage old: 9012679uAH (soc:87%), new: 5958129uAH (soc:91%), low cell: 4030 mV 01410 11/30/2025 10:26:24 Discharge level 006 AH, SOC: 93%, I:-29A, L:4085, l:4036, H:4102, B:017, PT:020C, BT:035C, PV:114580, M:Charge 01411 11/30/2025 10:26:24 SOC:5008,68733,6862,114800,95,92,93,-53 01412 11/30/2025 10:36:24 Discharge level 002 AH, SOC: 98%, I:-29A, L:4141, l:4095, H:4161, B:020, PT:021C, BT:037C, PV:116174, M:Charge 01413 11/30/2025 10:36:24 SOC:1560,70052,2112,114800,99,97,98,-54 01414 11/30/2025 10:44:51 DEBUG: Entered Standby State 01415 11/30/2025 10:44:51 DEBUG: CAN NOT Receiving Syncs 01416 11/30/2025 10:44:52 System Turned Off 01417 11/30/2025 10:44:53 DEBUG: CAN Link Is Down 01418 11/30/2025 10:44:53 DEBUG: Entered Idle State 01419 11/30/2025 10:44:53 Contactor was Opened Pack V: 115525mV, Switched V: 115436mV, Prechg Pct: 100%, Dischg Cur: 636mA 01420 11/30/2025 10:44:59 Current Sensor Zeroed old: 2504mV, new: 2507mV, corrfact: 249 01421 11/30/2025 10:45:00 Discharge level 000 AH, SOC:100%, I: 0A, L:4120, l:4103, H:4128, B:008, PT:021C, BT:038C, PV:115132, M:Idle 01422 11/30/2025 10:45:00 SOC:0,71248,0,114800,100,98,100,-20 01423 11/30/2025 10:45:21 Voltage Across Contactor: 101490mV (Okay) 01424 11/30/2025 10:46:43 System Turned On 01425 11/30/2025 10:46:43 Rev:45,Build:2023-05-20_045619 958 banka 01426 11/30/2025 10:46:43 Pack:2019_monolith,Numbricks:4 01427 11/30/2025 10:46:43 DEBUG: Entered Standby State 01428 11/30/2025 10:46:43 DEBUG: Entered Running State 01429 11/30/2025 10:46:43 DEBUG: CAN Link Is Up 01430 11/30/2025 10:46:44 DEBUG: Resetting CAN0 due to error passive mode 01431 11/30/2025 10:46:44 Discharge level 000 AH, SOC:100%, I: 0A, L:4106, l:4090, H:4111, B:005, PT:021C, BT:036C, PV:115036, M:Bike On 01432 11/30/2025 10:46:44 SOC:3,71248,0,114800,100,97,100,-19 01433 11/30/2025 10:46:47 DEBUG: CAN Receiving Syncs 01434 11/30/2025 10:46:47 Contactor drive turned on Pack V: 115016mV, Switched V: 101021mV, Duty Cycle: 34% 01435 11/30/2025 10:46:47 Contactor was Closed Pack V: 115016mV, Switched V: 101021mV, Prechg Pct: 88%, Dischg Cur: 545mA 01436 11/30/2025 10:47:44 Discharge level 000 AH, SOC:100%, I: 0A, L:4102, l:4096, H:4107, B:005, PT:021C, BT:034C, PV:114903, M:Bike On 01437 11/30/2025 10:47:44 SOC:153,71082,7,114800,100,97,100,-7 01438 11/30/2025 10:48:44 Discharge level 000 AH, SOC:100%, I: 1A, L:4085, l:4096, H:4088, B:003, PT:021C, BT:031C, PV:114408, M:Bike On 01439 11/30/2025 10:48:44 SOC:515,70471,280,114800,100,97,100,13 01440 11/30/2025 10:49:44 Discharge level 000 AH, SOC: 99%, I: 59A, L:3985, l:4024, H:4003, B:018, PT:021C, BT:031C, PV:111881, M:Bike On 01441 11/30/2025 10:49:44 SOC:752,70040,427,114800,100,90,99,45 01442 11/30/2025 10:50:44 Discharge level 000 AH, SOC: 99%, I: 1A, L:4054, l:4067, H:4063, B:009, PT:021C, BT:031C, PV:113650, M:Bike On 01443 11/30/2025 10:50:44 SOC:1013,69526,612,114800,100,94,99,16 01444 11/30/2025 10:51:44 Discharge level 000 AH, SOC: 99%, I: 0A, L:4081, l:4087, H:4085, B:004, PT:021C, BT:030C, PV:114327, M:Bike On 01445 11/30/2025 10:51:44 SOC:1216,69136,731,114800,100,96,99,7 01446 11/30/2025 10:52:44 Discharge level 000 AH, SOC: 99%, I: 71A, L:3968, l:4013, H:3991, B:023, PT:021C, BT:029C, PV:111472, M:Bike On 01447 11/30/2025 10:52:44 SOC:1302,68811,770,114800,100,89,99,52 01448 11/30/2025 10:53:44 Discharge level 001 AH, SOC: 97%, I:299A, L:3522, l:3761, H:3614, B:092, PT:021C, BT:028C, PV:100102, M:Bike On 01449 11/30/2025 10:53:44 SOC:2235,67377,1674,114800,99,65,97,278 01450 11/30/2025 10:54:44 Discharge level 002 AH, SOC: 96%, I: 44A, L:3946, l:4015, H:3967, B:021, PT:021C, BT:026C, PV:110859, M:Bike On 01451 11/30/2025 10:54:44 SOC:3276,65792,2695,114800,98,89,96,80 01452 11/30/2025 10:55:44 Discharge level 003 AH, SOC: 94%, I: 51A, L:3901, l:3981, H:3930, B:029, PT:021C, BT:027C, PV:109727, M:Bike On 01453 11/30/2025 10:55:44 SOC:4328,64168,3746,114800,97,86,94,92 01454 11/30/2025 10:56:44 Discharge level 004 AH, SOC: 92%, I:131A, L:3782, l:3897, H:3831, B:049, PT:022C, BT:027C, PV:106748, M:Bike On 01455 11/30/2025 10:56:44 SOC:5187,62899,4602,114800,96,79,92,141 01456 11/30/2025 10:57:44 Discharge level 005 AH, SOC: 90%, I: 1A, L:3948, l:4001, H:3967, B:019, PT:022C, BT:027C, PV:110889, M:Bike On 01457 11/30/2025 10:57:44 SOC:6271,61581,5703,114800,96,88,90,65 01458 11/30/2025 10:58:44 Discharge level 005 AH, SOC: 90%, I: 0A, L:3977, l:4003, H:3990, B:013, PT:022C, BT:026C, PV:111597, M:Bike On 01459 11/30/2025 10:58:44 SOC:6513,61223,5942,114800,95,88,90,32 01460 11/30/2025 10:59:44 Discharge level 006 AH, SOC: 89%, I: 1A, L:3988, l:4005, H:3999, B:011, PT:022C, BT:026C, PV:111856, M:Bike On 01461 11/30/2025 10:59:44 SOC:6705,60946,6142,114800,95,89,89,21 01462 11/30/2025 11:00:44 Discharge level 006 AH, SOC: 89%, I: 0A, L:3975, l:4001, H:3986, B:011, PT:022C, BT:025C, PV:111519, M:Bike On 01463 11/30/2025 11:00:44 SOC:7045,60607,6476,114800,95,88,89,31 01464 11/30/2025 11:01:44 Discharge level 006 AH, SOC: 89%, I: 1A, L:3991, l:4002, H:3999, B:008, PT:022C, BT:026C, PV:111905, M:Bike On 01465 11/30/2025 11:01:44 SOC:7091,60525,6528,114800,95,88,89,13 01466 11/30/2025 11:02:00 Contactor was Opened Pack V: 111949mV, Switched V: 111931mV, Prechg Pct: 100%, Dischg Cur: 909mA 01467 11/30/2025 11:02:01 System Turned Off 01468 11/30/2025 11:02:02 DEBUG: CAN Link Is Down 01469 11/30/2025 11:02:02 DEBUG: Entered Idle State 01470 11/30/2025 11:02:07 Current Sensor Zeroed old: 2507mV, new: 2504mV, corrfact: 252 01471 11/30/2025 11:02:09 Discharge level 006 AH, SOC: 89%, I: 0A, L:3995, l:4004, H:4003, B:008, PT:022C, BT:025C, PV:111958, M:Idle 01472 11/30/2025 11:02:09 SOC:7096,60516,6532,114800,95,88,89,11 01473 11/30/2025 11:02:30 Voltage Across Contactor: 99053mV (Okay) 01474 11/30/2025 11:18:58 System Turned On 01475 11/30/2025 11:18:58 Rev:45,Build:2023-05-20_045619 958 banka 01476 11/30/2025 11:18:58 Pack:2019_monolith,Numbricks:4 01477 11/30/2025 11:18:58 DEBUG: Entered Running State 01478 11/30/2025 11:18:58 DEBUG: CAN NOT Receiving Syncs 01479 11/30/2025 11:18:59 DEBUG: CAN Link Is Up 01480 11/30/2025 11:18:59 DEBUG: Resetting CAN0 due to error passive mode 01481 11/30/2025 11:19:00 Discharge level 006 AH, SOC: 89%, I: 0A, L:4007, l:4017, H:4013, B:006, PT:022C, BT:035C, PV:112326, M:Bike On 01482 11/30/2025 11:19:00 SOC:7095,60516,6532,114800,95,90,89,11 01483 11/30/2025 11:19:03 DEBUG: CAN Receiving Syncs 01484 11/30/2025 11:19:03 Contactor drive turned on Pack V: 112294mV, Switched V: 98304mV, Duty Cycle: 35% 01485 11/30/2025 11:19:03 Contactor was Closed Pack V: 112294mV, Switched V: 98304mV, Prechg Pct: 88%, Dischg Cur: 909mA 01486 11/30/2025 11:20:00 Discharge level 006 AH, SOC: 89%, I: 1A, L:4006, l:4013, H:4011, B:005, PT:022C, BT:033C, PV:112282, M:Bike On 01487 11/30/2025 11:20:00 SOC:7088,60645,6548,114800,95,89,89,8 01488 11/30/2025 11:21:00 Discharge level 006 AH, SOC: 88%, I: -4A, L:4009, l:4021, H:4012, B:003, PT:022C, BT:031C, PV:112320, M:Bike On 01489 11/30/2025 11:21:00 SOC:7274,60522,6758,114800,95,90,88,13 01490 11/30/2025 11:22:00 Discharge level 007 AH, SOC: 88%, I: 1A, L:3973, l:3998, H:3982, B:009, PT:022C, BT:031C, PV:111423, M:Bike On 01491 11/30/2025 11:22:00 SOC:7683,60170,7200,114800,94,88,88,29 01492 11/30/2025 11:23:00 Discharge level 007 AH, SOC: 87%, I:135A, L:3738, l:3853, H:3793, B:055, PT:022C, BT:029C, PV:105624, M:Bike On 01493 11/30/2025 11:23:00 SOC:8119,59750,7679,114800,94,74,87,129 01494 11/30/2025 11:24:00 Discharge level 009 AH, SOC: 84%, I: 2A, L:3919, l:3975, H:3933, B:014, PT:022C, BT:028C, PV:109999, M:Bike On 01495 11/30/2025 11:24:00 SOC:9466,58669,9072,114800,93,86,84,67 01496 11/30/2025 11:25:00 Discharge level 010 AH, SOC: 81%, I: 1A, L:3869, l:3945, H:3890, B:021, PT:023C, BT:027C, PV:108749, M:Bike On 01497 11/30/2025 11:25:00 SOC:11150,57628,10758,114800,91,83,81,90 01498 11/30/2025 11:26:00 Discharge level 012 AH, SOC: 78%, I: 94A, L:3702, l:3853, H:3752, B:050, PT:023C, BT:026C, PV:104569, M:Bike On 01499 11/30/2025 11:26:00 SOC:12878,56737,12500,114800,90,74,78,177 01500 11/30/2025 11:26:00 Discharge cutback 89% 01501 11/30/2025 11:26:00 763A 01502 11/30/2025 11:27:00 Discharge level 014 AH, SOC: 74%, I: 3A, L:3787, l:3923, H:3813, B:026, PT:024C, BT:026C, PV:106521, M:Bike On 01503 11/30/2025 11:27:00 SOC:14790,55941,14416,114800,88,81,74,163 01504 11/30/2025 11:27:00 Discharge cutback 78% 01505 11/30/2025 11:27:00 668A 01506 11/30/2025 11:28:00 Discharge level 016 AH, SOC: 70%, I: 1A, L:3791, l:3880, H:3815, B:024, PT:025C, BT:026C, PV:106612, M:Bike On 01507 11/30/2025 11:28:00 SOC:17033,55388,16727,114800,86,77,70,110 01508 11/30/2025 11:29:00 Discharge level 017 AH, SOC: 70%, I:191A, L:3593, l:3752, H:3663, B:070, PT:026C, BT:026C, PV:101915, M:Bike On 01509 11/30/2025 11:29:00 SOC:17303,56237,17043,114800,86,63,70,196 01510 11/30/2025 11:30:00 Discharge level 017 AH, SOC: 69%, I: 80A, L:3721, l:3817, H:3761, B:040, PT:026C, BT:026C, PV:104953, M:Bike On 01511 11/30/2025 11:30:00 SOC:17757,56554,17691,114800,85,70,69,118 01512 11/30/2025 11:31:00 Discharge level 018 AH, SOC: 69%, I: 0A, L:3827, l:3864, H:3841, B:014, PT:026C, BT:025C, PV:107437, M:Bike On 01513 11/30/2025 11:31:00 SOC:18151,56991,18250,114800,85,75,69,47 01514 11/30/2025 11:32:00 Discharge level 018 AH, SOC: 68%, I: 1A, L:3821, l:3856, H:3836, B:015, PT:026C, BT:025C, PV:107303, M:Bike On 01515 11/30/2025 11:32:00 SOC:18382,57426,18668,114800,84,75,68,44 01516 11/30/2025 11:32:52 Contactor was Opened Pack V: 107798mV, Switched V: 107795mV, Prechg Pct: 100%, Dischg Cur: 909mA 01517 11/30/2025 11:32:53 System Turned Off 01518 11/30/2025 11:32:53 DEBUG: CAN Link Is Down 01519 11/30/2025 11:32:53 DEBUG: Entered Idle State 01520 11/30/2025 11:33:00 Discharge level 018 AH, SOC: 69%, I: 0A, L:3844, l:3861, H:3856, B:012, PT:026C, BT:026C, PV:107862, M:Idle 01521 11/30/2025 11:33:00 SOC:18324,58154,18700,114800,84,75,69,22 01522 11/30/2025 11:33:22 Voltage Across Contactor: 94705mV (Okay) 01523 11/30/2025 11:43:21 System Turned On 01524 11/30/2025 11:43:21 Rev:45,Build:2023-05-20_045619 958 banka 01525 11/30/2025 11:43:21 Pack:2019_monolith,Numbricks:4 01526 11/30/2025 11:43:21 DEBUG: Entered Running State 01527 11/30/2025 11:43:21 DEBUG: CAN NOT Receiving Syncs 01528 11/30/2025 11:43:21 DEBUG: CAN Link Is Up 01529 11/30/2025 11:43:22 DEBUG: Resetting CAN0 due to error passive mode 01530 11/30/2025 11:43:22 Discharge level 018 AH, SOC: 69%, I: 0A, L:3868, l:3885, H:3878, B:010, PT:026C, BT:024C, PV:108462, M:Bike On 01531 11/30/2025 11:43:22 SOC:18319,58154,18700,114800,84,77,69,22 01532 11/30/2025 11:43:25 DEBUG: CAN Receiving Syncs 01533 11/30/2025 11:43:26 Contactor drive turned on Pack V: 108447mV, Switched V: 95074mV, Duty Cycle: 37% 01534 11/30/2025 11:43:26 Contactor was Closed Pack V: 108447mV, Switched V: 95074mV, Prechg Pct: 88%, Dischg Cur: 545mA 01535 11/30/2025 11:44:22 Discharge level 018 AH, SOC: 70%, I: 1A, L:3862, l:3878, H:3872, B:010, PT:026C, BT:024C, PV:108313, M:Bike On 01536 11/30/2025 11:44:22 SOC:18232,58960,18779,114800,84,77,70,20 01537 11/30/2025 11:45:22 Discharge level 019 AH, SOC: 70%, I:102A, L:3723, l:3800, H:3759, B:036, PT:026C, BT:025C, PV:104919, M:Bike On 01538 11/30/2025 11:45:22 SOC:18388,59507,19121,114800,84,69,70,95 01539 11/30/2025 11:46:22 Discharge level 019 AH, SOC: 70%, I: 1A, L:3848, l:3865, H:3858, B:010, PT:026C, BT:024C, PV:107907, M:Bike On 01540 11/30/2025 11:46:22 SOC:18493,60202,19333,114800,84,76,70,21 01541 11/30/2025 11:47:22 Discharge level 019 AH, SOC: 70%, I: 31A, L:3815, l:3841, H:3830, B:015, PT:026C, BT:025C, PV:107088, M:Bike On 01542 11/30/2025 11:47:22 SOC:18353,60723,19384,114800,84,73,70,32 01543 11/30/2025 11:48:22 Discharge level 019 AH, SOC: 71%, I: 1A, L:3856, l:3863, H:3864, B:008, PT:026C, BT:024C, PV:108091, M:Bike On 01544 11/30/2025 11:48:22 SOC:18195,61132,19434,114800,84,75,71,9 01545 11/30/2025 11:49:22 Discharge level 019 AH, SOC: 71%, I:-21A, L:3872, l:3873, H:3881, B:009, PT:026C, BT:024C, PV:108537, M:Bike On 01546 11/30/2025 11:49:22 SOC:18343,61594,19671,114800,83,76,71,1 01547 11/30/2025 11:50:22 Discharge level 020 AH, SOC: 70%, I: 7A, L:3831, l:3851, H:3841, B:010, PT:026C, BT:025C, PV:107428, M:Bike On 01548 11/30/2025 11:50:22 SOC:18581,61899,20027,114800,83,74,70,25 01549 11/30/2025 11:51:22 Discharge level 020 AH, SOC: 70%, I: 1A, L:3796, l:3831, H:3811, B:015, PT:026C, BT:025C, PV:106558, M:Bike On 01550 11/30/2025 11:51:22 SOC:19092,62093,20583,114800,83,72,70,44 01551 11/30/2025 11:52:22 Discharge level 021 AH, SOC: 69%, I:-14A, L:3828, l:3854, H:3835, B:007, PT:026C, BT:023C, PV:107257, M:Bike On 01552 11/30/2025 11:52:22 SOC:19511,62170,21104,114800,82,75,69,32 01553 11/30/2025 11:53:22 Discharge level 021 AH, SOC: 68%, I: 58A, L:3729, l:3786, H:3755, B:026, PT:026C, BT:025C, PV:104901, M:Bike On 01554 11/30/2025 11:53:22 SOC:19962,62282,21633,114800,82,67,68,71 01555 11/30/2025 11:54:22 Discharge level 022 AH, SOC: 68%, I: -9A, L:3817, l:3835, H:3824, B:007, PT:026C, BT:025C, PV:106966, M:Bike On 01556 11/30/2025 11:54:22 SOC:20215,62365,22027,114800,81,73,68,22 01557 11/30/2025 11:55:22 Discharge level 022 AH, SOC: 68%, I: 1A, L:3815, l:3825, H:3824, B:009, PT:025C, BT:025C, PV:106950, M:Bike On 01558 11/30/2025 11:55:22 SOC:20144,62839,22045,114800,81,72,68,13 01559 11/30/2025 11:56:22 Discharge level 022 AH, SOC: 69%, I: 0A, L:3821, l:3827, H:3829, B:008, PT:025C, BT:025C, PV:107099, M:Bike On 01560 11/30/2025 11:56:22 SOC:20036,63184,22057,114800,81,72,69,8 01561 11/30/2025 11:57:22 Discharge level 022 AH, SOC: 69%, I: 0A, L:3823, l:3828, H:3830, B:007, PT:025C, BT:024C, PV:107158, M:Bike On 01562 11/30/2025 11:57:22 SOC:19937,63501,22068,114800,81,72,69,6 01563 11/30/2025 11:58:22 Discharge level 022 AH, SOC: 69%, I: 1A, L:3824, l:3828, H:3832, B:008, PT:025C, BT:025C, PV:107196, M:Bike On 01564 11/30/2025 11:58:22 SOC:19847,63793,22080,114800,81,72,69,5 01565 11/30/2025 11:59:22 Discharge level 022 AH, SOC: 70%, I: 0A, L:3826, l:3829, H:3834, B:008, PT:025C, BT:025C, PV:107239, M:Bike On 01566 11/30/2025 11:59:22 SOC:19765,64061,22092,114800,81,72,70,4 01567 11/30/2025 12:00:22 Discharge level 022 AH, SOC: 70%, I: 0A, L:3827, l:3830, H:3835, B:008, PT:025C, BT:025C, PV:107254, M:Bike On 01568 11/30/2025 12:00:22 SOC:19690,64309,22103,114800,81,72,70,3 01569 11/30/2025 12:01:22 Discharge level 022 AH, SOC: 70%, I: 1A, L:3827, l:3830, H:3835, B:008, PT:025C, BT:025C, PV:107264, M:Bike On 01570 11/30/2025 12:01:22 SOC:19620,64532,22115,114800,81,72,70,3 01571 11/30/2025 12:02:11 DEBUG: Entered Charging State 01572 11/30/2025 12:02:11 DEBUG: CAN NOT Receiving Syncs 01573 11/30/2025 12:02:12 Discharge level 022 AH, SOC: 70%, I: 0A, L:3827, l:3829, H:3835, B:008, PT:025C, BT:025C, PV:107261, M:Charge 01574 11/30/2025 12:02:12 SOC:19610,64760,22141,114800,81,72,70,3 01575 11/30/2025 12:02:12 DEBUG: CAN Receiving Syncs 01576 11/30/2025 12:12:12 Discharge level 020 AH, SOC: 76%, I:-10A, L:3890, l:3874, H:3897, B:007, PT:025C, BT:032C, PV:109012, M:Charge 01577 11/30/2025 12:12:12 SOC:14965,62002,20287,114800,83,77,76,-20 01578 11/30/2025 12:22:12 Discharge level 018 AH, SOC: 80%, I:-11A, L:3918, l:3901, H:3923, B:005, PT:025C, BT:038C, PV:109787, M:Charge 01579 11/30/2025 12:22:12 SOC:12728,61655,18415,114800,84,79,80,-21 01580 11/30/2025 12:32:12 Discharge level 016 AH, SOC: 82%, I:-11A, L:3941, l:3924, H:3946, B:005, PT:024C, BT:038C, PV:110439, M:Charge 01581 11/30/2025 12:32:12 SOC:11339,62141,16556,114800,86,81,82,-20 01582 11/30/2025 12:42:20 Discharge level 014 AH, SOC: 84%, I:-10A, L:3964, l:3948, H:3967, B:003, PT:024C, BT:038C, PV:111035, M:Charge 01583 11/30/2025 12:42:20 SOC:10185,62841,14720,114800,88,83,84,-20 01584 11/30/2025 12:52:20 Discharge level 012 AH, SOC: 86%, I:-10A, L:3984, l:3968, H:3988, B:004, PT:024C, BT:034C, PV:111601, M:Charge 01585 11/30/2025 12:52:20 SOC:9056,63521,12929,114800,89,85,86,-20 01586 11/30/2025 13:02:20 Discharge level 011 AH, SOC: 88%, I:-10A, L:4004, l:3988, H:4007, B:003, PT:024C, BT:033C, PV:112150, M:Charge 01587 11/30/2025 13:02:20 SOC:7993,64241,11165,114800,91,87,88,-20 01588 11/30/2025 13:12:20 Discharge level 009 AH, SOC: 90%, I:-10A, L:4023, l:4008, H:4027, B:004, PT:024C, BT:031C, PV:112696, M:Charge 01589 11/30/2025 13:12:20 SOC:6904,64905,9430,114800,92,89,90,-19 01590 11/30/2025 13:14:01 Charged To Full 009 AH, SOC: 90%, L:4027, H:4030, B:003, PT:024C, BT:034C, PV:112752 01591 11/30/2025 13:14:01 SOC adjusted for voltage old: 6757556uAH (soc:90%), new: 5854510uAH (soc:91%), low cell: 4027 mV 01592 11/30/2025 13:22:20 Discharge level 008 AH, SOC: 92%, I:-10A, L:4043, l:4028, H:4046, B:003, PT:024C, BT:034C, PV:113239, M:Charge 01593 11/30/2025 13:22:20 SOC:5752,66395,8899,114800,93,91,92,-19 01594 11/30/2025 13:32:20 Discharge level 007 AH, SOC: 93%, I:-10A, L:4062, l:4047, H:4066, B:004, PT:023C, BT:036C, PV:113792, M:Charge 01595 11/30/2025 13:32:20 SOC:4802,67178,7185,114800,94,93,93,-19 01596 11/30/2025 13:42:20 Discharge level 005 AH, SOC: 95%, I:-10A, L:4081, l:4066, H:4085, B:004, PT:023C, BT:035C, PV:114320, M:Charge 01597 11/30/2025 13:42:20 SOC:3622,67723,5480,114800,96,94,95,-19 01598 11/30/2025 13:52:28 Discharge level 003 AH, SOC: 97%, I:-10A, L:4101, l:4086, H:4106, B:005, PT:023C, BT:038C, PV:114880, M:Charge 01599 11/30/2025 13:52:28 SOC:2372,68210,3763,114800,97,96,97,-19 01600 11/30/2025 14:32:30 DEBUG: CAN Link Is Down 01601 11/30/2025 14:32:34 Contactor was Opened Pack V: 116016mV, Switched V: 116066mV, Prechg Pct: 100%, Dischg Cur: 363mA 01602 11/30/2025 14:32:34 DEBUG: CAN Link Is Up 01603 11/30/2025 14:32:36 System Turned Off 01604 11/30/2025 14:32:37 DEBUG: CAN Link Is Down 01605 11/30/2025 14:32:37 DEBUG: Entered Idle State 01606 11/30/2025 14:32:44 Discharge level 000 AH, SOC:100%, I: 0A, L:4146, l:4143, H:4149, B:003, PT:023C, BT:035C, PV:116000, M:Idle 01607 11/30/2025 14:32:44 SOC:0,68949,0,114800,100,100,100,-4 01608 11/30/2025 14:33:04 Voltage Across Contactor: 103064mV (Okay) 01609 11/30/2025 21:54:40 System Turned On 01610 11/30/2025 21:54:40 Rev:45,Build:2023-05-20_045619 958 banka 01611 11/30/2025 21:54:41 Pack:2019_monolith,Numbricks:4 01612 11/30/2025 21:54:41 DEBUG: Entered Charging State 01613 11/30/2025 21:54:41 DEBUG: CAN NOT Receiving Syncs 01614 11/30/2025 21:54:41 DEBUG: Entered Running State 01615 11/30/2025 21:54:41 DEBUG: CAN Link Is Up 01616 11/30/2025 21:54:41 DEBUG: Resetting CAN0 due to error passive mode 01617 11/30/2025 21:54:42 Discharge level 000 AH, SOC:100%, I: 0A, L:4118, l:4115, H:4120, B:002, PT:017C, BT:021C, PV:115345, M:Bike On 01618 11/30/2025 21:54:42 SOC:1,68949,0,114800,100,99,100,-3 01619 11/30/2025 21:54:45 DEBUG: CAN Receiving Syncs 01620 11/30/2025 21:54:50 Contactor drive turned on Pack V: 115324mV, Switched V: 102281mV, Duty Cycle: 34% 01621 11/30/2025 21:54:50 Contactor was Closed Pack V: 115324mV, Switched V: 102281mV, Prechg Pct: 89%, Dischg Cur: 363mA 01622 11/30/2025 21:55:42 Discharge level 000 AH, SOC:100%, I: 1A, L:4116, l:4116, H:4118, B:002, PT:017C, BT:022C, PV:115281, M:Bike On 01623 11/30/2025 21:55:42 SOC:51,68894,6,114800,100,99,100,0 01624 11/30/2025 21:56:42 Discharge level 000 AH, SOC:100%, I: 1A, L:4115, l:4115, H:4118, B:003, PT:017C, BT:022C, PV:115268, M:Bike On 01625 11/30/2025 21:56:42 SOC:82,68759,24,114800,100,99,100,0 01626 11/30/2025 21:57:42 Discharge level 000 AH, SOC:100%, I: 1A, L:4100, l:4114, H:4104, B:004, PT:017C, BT:022C, PV:114859, M:Bike On 01627 11/30/2025 21:57:42 SOC:324,68223,263,114800,100,99,100,13 01628 11/30/2025 21:58:42 Discharge level 000 AH, SOC:100%, I: 1A, L:4105, l:4111, H:4108, B:003, PT:017C, BT:021C, PV:114990, M:Bike On 01629 11/30/2025 21:58:42 SOC:375,67948,331,114800,100,99,100,6 01630 11/30/2025 21:59:42 Discharge level 000 AH, SOC:100%, I: 0A, L:4070, l:4087, H:4079, B:009, PT:017C, BT:022C, PV:114093, M:Bike On 01631 11/30/2025 21:59:42 SOC:568,67451,537,114800,100,96,100,17 01632 11/30/2025 22:00:42 Discharge level 000 AH, SOC:100%, I: 1A, L:4099, l:4106, H:4102, B:003, PT:017C, BT:022C, PV:114825, M:Bike On 01633 11/30/2025 22:00:42 SOC:626,67131,616,114800,100,98,100,6 01634 11/30/2025 22:01:42 Discharge level 001 AH, SOC: 99%, I: 2A, L:4070, l:4103, H:4077, B:007, PT:017C, BT:021C, PV:114070, M:Bike On 01635 11/30/2025 22:01:42 SOC:1138,66183,1132,114800,100,98,99,32 01636 11/30/2025 22:02:42 Discharge level 002 AH, SOC: 97%, I: 1A, L:3992, l:4071, H:4009, B:017, PT:017C, BT:021C, PV:112043, M:Bike On 01637 11/30/2025 22:02:42 SOC:2356,64586,2349,114800,98,95,97,76 01638 11/30/2025 22:03:42 Discharge level 003 AH, SOC: 95%, I:180A, L:3693, l:3896, H:3753, B:060, PT:018C, BT:021C, PV:104288, M:Bike On 01639 11/30/2025 22:03:42 SOC:3497,63035,3487,114800,97,78,95,198 01640 11/30/2025 22:04:42 Discharge level 004 AH, SOC: 93%, I: 80A, L:3824, l:3942, H:3864, B:040, PT:018C, BT:020C, PV:107667, M:Bike On 01641 11/30/2025 22:04:42 SOC:4478,61866,4463,114800,97,83,93,120 01642 11/30/2025 22:05:42 Discharge level 005 AH, SOC: 91%, I: 69A, L:3820, l:3948, H:3859, B:039, PT:018C, BT:020C, PV:107561, M:Bike On 01643 11/30/2025 22:05:42 SOC:5747,60484,5732,114800,96,83,91,129 01644 11/30/2025 22:06:42 Discharge level 007 AH, SOC: 88%, I:105A, L:3740, l:3911, H:3791, B:051, PT:019C, BT:020C, PV:105543, M:Bike On 01645 11/30/2025 22:06:42 SOC:7198,59241,7184,114800,94,79,88,170 01646 11/30/2025 22:07:42 Discharge level 009 AH, SOC: 85%, I:149A, L:3634, l:3857, H:3701, B:067, PT:019C, BT:020C, PV:102883, M:Bike On 01647 11/30/2025 22:07:42 SOC:9059,57907,9047,114800,93,73,85,218 01648 11/30/2025 22:08:42 Discharge level 011 AH, SOC: 81%, I:103A, L:3681, l:3880, H:3739, B:058, PT:020C, BT:021C, PV:104099, M:Bike On 01649 11/30/2025 22:08:42 SOC:11061,56886,11054,114800,91,76,81,204 01650 11/30/2025 22:09:42 Discharge level 013 AH, SOC: 77%, I: 0A, L:3831, l:3967, H:3859, B:028, PT:021C, BT:021C, PV:107795, M:Bike On 01651 11/30/2025 22:09:42 SOC:13284,55970,13310,114800,89,84,77,138 01652 11/30/2025 22:10:42 Discharge level 014 AH, SOC: 74%, I: 75A, L:3716, l:3859, H:3769, B:053, PT:022C, BT:020C, PV:105049, M:Bike On 01653 11/30/2025 22:10:42 SOC:14779,55644,14894,114800,88,74,74,155 01654 11/30/2025 22:11:42 Discharge level 015 AH, SOC: 74%, I: 2A, L:3857, l:3929, H:3882, B:025, PT:022C, BT:020C, PV:108497, M:Bike On 01655 11/30/2025 22:11:42 SOC:14996,55916,15354,114800,87,81,74,78 01656 11/30/2025 22:12:42 Discharge level 016 AH, SOC: 73%, I: 47A, L:3814, l:3893, H:3846, B:032, PT:023C, BT:021C, PV:107416, M:Bike On 01657 11/30/2025 22:12:42 SOC:15595,56011,16186,114800,86,78,73,92 01658 11/30/2025 22:13:42 Discharge level 016 AH, SOC: 73%, I:-13A, L:3889, l:3916, H:3905, B:016, PT:023C, BT:020C, PV:109222, M:Bike On 01659 11/30/2025 22:13:42 SOC:15601,56234,16530,114800,86,80,73,32 01660 11/30/2025 22:14:42 Discharge level 016 AH, SOC: 73%, I: 80A, L:3737, l:3820, H:3790, B:053, PT:023C, BT:021C, PV:105681, M:Bike On 01661 11/30/2025 22:14:42 SOC:15680,56597,16866,114800,86,71,73,97 01662 11/30/2025 22:15:42 Discharge level 017 AH, SOC: 73%, I: 21A, L:3856, l:3890, H:3880, B:024, PT:023C, BT:021C, PV:108439, M:Bike On 01663 11/30/2025 22:15:42 SOC:15688,56971,17129,114800,86,78,73,39 01664 11/30/2025 22:16:42 Discharge level 017 AH, SOC: 72%, I:141A, L:3637, l:3760, H:3711, B:074, PT:023C, BT:021C, PV:103293, M:Bike On 01665 11/30/2025 22:16:42 SOC:16249,57337,17790,114800,85,64,72,143 01666 11/30/2025 22:17:42 Discharge level 018 AH, SOC: 71%, I: 1A, L:3833, l:3878, H:3859, B:026, PT:024C, BT:021C, PV:107855, M:Bike On 01667 11/30/2025 22:17:42 SOC:17072,57724,18647,114800,84,77,71,53 01668 11/30/2025 22:18:42 Discharge level 019 AH, SOC: 70%, I: 1A, L:3839, l:3887, H:3858, B:019, PT:024C, BT:022C, PV:107884, M:Bike On 01669 11/30/2025 22:18:42 SOC:17413,57593,19339,114800,84,77,70,56 01670 11/30/2025 22:19:42 Discharge level 020 AH, SOC: 69%, I: 56A, L:3773, l:3842, H:3806, B:033, PT:024C, BT:022C, PV:106299, M:Bike On 01671 11/30/2025 22:19:42 SOC:18008,58018,20023,114800,83,73,69,82 01672 11/30/2025 22:20:42 Discharge level 020 AH, SOC: 70%, I: 48A, L:3803, l:3852, H:3831, B:028, PT:024C, BT:021C, PV:107041, M:Bike On 01673 11/30/2025 22:20:42 SOC:18046,58474,20289,114800,83,74,70,59 01674 11/30/2025 22:21:42 Discharge level 020 AH, SOC: 69%, I: 41A, L:3793, l:3845, H:3821, B:028, PT:024C, BT:022C, PV:106762, M:Bike On 01675 11/30/2025 22:21:42 SOC:18349,58802,20785,114800,82,73,69,62 01676 11/30/2025 22:22:42 Discharge level 021 AH, SOC: 69%, I: 1A, L:3833, l:3869, H:3850, B:017, PT:024C, BT:021C, PV:107688, M:Bike On 01677 11/30/2025 22:22:42 SOC:18535,59153,21186,114800,82,76,69,43 01678 11/30/2025 22:23:42 Discharge level 021 AH, SOC: 70%, I: 1A, L:3843, l:3867, H:3859, B:016, PT:024C, BT:022C, PV:107927, M:Bike On 01679 11/30/2025 22:23:42 SOC:18380,59332,21390,114800,82,76,70,29 01680 11/30/2025 22:24:42 Discharge level 021 AH, SOC: 69%, I: 0A, L:3838, l:3861, H:3855, B:017, PT:024C, BT:021C, PV:107808, M:Bike On 01681 11/30/2025 22:24:42 SOC:18602,59931,21695,114800,82,75,69,28 01682 11/30/2025 22:25:42 Discharge level 022 AH, SOC: 69%, I: 1A, L:3821, l:3853, H:3838, B:017, PT:024C, BT:022C, PV:107329, M:Bike On 01683 11/30/2025 22:25:42 SOC:19080,59918,22392,114800,81,74,69,39 01684 11/30/2025 22:26:42 Discharge level 023 AH, SOC: 68%, I: 71A, L:3712, l:3789, H:3751, B:039, PT:025C, BT:022C, PV:104722, M:Bike On 01685 11/30/2025 22:26:42 SOC:19693,59921,23175,114800,80,67,68,92 01686 11/30/2025 22:27:42 Discharge level 023 AH, SOC: 67%, I: 72A, L:3709, l:3793, H:3747, B:038, PT:025C, BT:021C, PV:104606, M:Bike On 01687 11/30/2025 22:27:42 SOC:20475,60230,23973,114800,80,68,67,101 01688 11/30/2025 22:28:42 Discharge level 024 AH, SOC: 65%, I: 1A, L:3782, l:3826, H:3799, B:017, PT:025C, BT:023C, PV:106250, M:Bike On 01689 11/30/2025 22:28:42 SOC:21285,60350,24859,114800,79,71,65,53 01690 11/30/2025 22:29:42 Discharge level 026 AH, SOC: 62%, I:102A, L:3587, l:3732, H:3650, B:063, PT:025C, BT:023C, PV:101676, M:Bike On 01691 11/30/2025 22:29:42 SOC:23167,59828,26759,114800,77,60,62,175 01692 11/30/2025 22:30:42 Discharge level 027 AH, SOC: 61%, I: 0A, L:3744, l:3792, H:3764, B:020, PT:025C, BT:021C, PV:105262, M:Bike On 01693 11/30/2025 22:30:42 SOC:23938,60354,27568,114800,76,68,61,60 01694 11/30/2025 22:31:42 Discharge level 027 AH, SOC: 61%, I: 31A, L:3727, l:3772, H:3751, B:024, PT:025C, BT:023C, PV:104853, M:Bike On 01695 11/30/2025 22:31:42 SOC:24039,60979,27855,114800,76,66,61,56 01696 11/30/2025 22:32:42 Discharge level 027 AH, SOC: 62%, I: 1A, L:3776, l:3794, H:3790, B:014, PT:025C, BT:022C, PV:106008, M:Bike On 01697 11/30/2025 22:32:42 SOC:24004,61807,27968,114800,76,68,62,22 01698 11/30/2025 22:33:09 Contactor was Opened Pack V: 106126mV, Switched V: 106102mV, Prechg Pct: 100%, Dischg Cur: 909mA 01699 11/30/2025 22:33:10 System Turned Off 01700 11/30/2025 22:33:11 DEBUG: CAN Link Is Down 01701 11/30/2025 22:33:11 DEBUG: Entered Idle State 01702 11/30/2025 22:33:16 Current Sensor Zeroed old: 2504mV, new: 2506mV, corrfact: 250 01703 11/30/2025 22:33:18 Discharge level 027 AH, SOC: 62%, I: 0A, L:3783, l:3796, H:3796, B:013, PT:025C, BT:023C, PV:106176, M:Idle 01704 11/30/2025 22:33:18 SOC:24009,62328,27979,114800,76,69,62,17 01705 11/30/2025 22:33:39 Voltage Across Contactor: 92846mV (Okay) 01706 11/30/2025 22:34:15 System Turned On 01707 11/30/2025 22:34:15 Rev:45,Build:2023-05-20_045619 958 banka 01708 11/30/2025 22:34:15 Pack:2019_monolith,Numbricks:4 01709 11/30/2025 22:34:15 DEBUG: Entered Running State 01710 11/30/2025 22:34:15 DEBUG: CAN NOT Receiving Syncs 01711 11/30/2025 22:34:15 DEBUG: CAN Link Is Up 01712 11/30/2025 22:34:16 DEBUG: Resetting CAN0 due to error passive mode 01713 11/30/2025 22:34:16 Discharge level 027 AH, SOC: 62%, I: 0A, L:3789, l:3802, H:3801, B:012, PT:025C, BT:022C, PV:106311, M:Bike On 01714 11/30/2025 22:34:16 SOC:24004,62328,27979,114800,76,69,62,17 01715 11/30/2025 22:34:19 DEBUG: CAN Receiving Syncs 01716 11/30/2025 22:34:19 Contactor drive turned on Pack V: 106306mV, Switched V: 93223mV, Duty Cycle: 37% 01717 11/30/2025 22:34:20 Contactor was Closed Pack V: 106306mV, Switched V: 93223mV, Prechg Pct: 88%, Dischg Cur: 636mA 01718 11/30/2025 22:34:21 DEBUG: Entered Charging State 01719 11/30/2025 22:34:21 DEBUG: CAN NOT Receiving Syncs 01720 11/30/2025 22:34:22 Discharge level 027 AH, SOC: 62%, I: 0A, L:3789, l:3802, H:3801, B:012, PT:025C, BT:023C, PV:106316, M:Charge 01721 11/30/2025 22:34:22 SOC:23970,62344,27979,114800,76,69,62,16 01722 11/30/2025 22:34:23 DEBUG: CAN Receiving Syncs 01723 11/30/2025 22:44:22 Discharge level 026 AH, SOC: 73%, I:-11A, L:3861, l:3844, H:3868, B:007, PT:025C, BT:030C, PV:108211, M:Charge 01724 11/30/2025 22:44:22 SOC:15622,55926,26111,114800,78,74,73,-20 01725 11/30/2025 22:54:22 Discharge level 024 AH, SOC: 77%, I:-11A, L:3895, l:3878, H:3901, B:006, PT:025C, BT:033C, PV:109141, M:Charge 01726 11/30/2025 22:54:22 SOC:12609,54813,24226,114800,79,77,77,-21 01727 11/30/2025 23:04:22 Discharge level 022 AH, SOC: 80%, I:-11A, L:3920, l:3903, H:3926, B:006, PT:025C, BT:037C, PV:109867, M:Charge 01728 11/30/2025 23:04:22 SOC:11165,55241,22370,114800,81,79,80,-21 01729 11/30/2025 23:14:30 Discharge level 020 AH, SOC: 83%, I:-10A, L:3944, l:3928, H:3948, B:004, PT:024C, BT:039C, PV:110509, M:Charge 01730 11/30/2025 23:14:30 SOC:10048,55999,20513,114800,83,82,83,-20 01731 11/30/2025 23:24:30 Discharge level 018 AH, SOC: 85%, I:-10A, L:3965, l:3949, H:3969, B:004, PT:024C, BT:038C, PV:111100, M:Charge 01732 11/30/2025 23:24:30 SOC:9053,56840,18697,114800,84,84,85,-20 01733 11/30/2025 23:34:30 Discharge level 016 AH, SOC: 86%, I:-10A, L:3986, l:3969, H:3990, B:004, PT:023C, BT:035C, PV:111669, M:Charge 01734 11/30/2025 23:34:30 SOC:8110,57707,16905,114800,86,85,86,-20 01735 11/30/2025 23:44:30 Discharge level 015 AH, SOC: 88%, I:-10A, L:4006, l:3990, H:4010, B:004, PT:023C, BT:030C, PV:112234, M:Charge 01736 11/30/2025 23:44:30 SOC:7139,58536,15123,114800,87,87,88,-20 01737 11/30/2025 23:54:30 Discharge level 013 AH, SOC: 90%, I:-10A, L:4027, l:4011, H:4030, B:003, PT:023C, BT:030C, PV:112795, M:Charge 01738 11/30/2025 23:54:30 SOC:6125,59307,13355,114800,89,89,90,-19 01739 11/30/2025 23:54:31 Charged To Full 013 AH, SOC: 90%, L:4027, H:4030, B:003, PT:023C, BT:030C, PV:112793 01740 11/30/2025 23:54:31 SOC adjusted for voltage old: 6124770uAH (soc:90%), new: 5337847uAH (soc:91%), low cell: 4027 mV 01741 12/01/2025 00:04:30 Discharge level 008 AH, SOC: 92%, I:-10A, L:4047, l:4030, H:4051, B:004, PT:022C, BT:032C, PV:113356, M:Charge 01742 12/01/2025 00:04:30 SOC:5072,60807,8585,114800,93,91,92,-19 01743 12/01/2025 00:14:30 Discharge level 006 AH, SOC: 94%, I:-10A, L:4067, l:4050, H:4071, B:004, PT:022C, BT:034C, PV:113921, M:Charge 01744 12/01/2025 00:14:30 SOC:4037,61529,6847,114800,95,93,94,-19 01745 12/01/2025 00:24:38 Discharge level 005 AH, SOC: 96%, I:-10A, L:4087, l:4070, H:4091, B:004, PT:022C, BT:033C, PV:114486, M:Charge 01746 12/01/2025 00:24:38 SOC:2894,62147,5106,114800,96,95,96,-19 01747 12/01/2025 01:10:00 DEBUG: CAN Link Is Down 01748 12/01/2025 01:10:04 Contactor was Opened Pack V: 116013mV, Switched V: 115987mV, Prechg Pct: 100%, Dischg Cur: 636mA 01749 12/01/2025 01:10:04 DEBUG: CAN Link Is Up 01750 12/01/2025 01:10:06 System Turned Off 01751 12/01/2025 01:10:07 DEBUG: CAN Link Is Down 01752 12/01/2025 01:10:07 DEBUG: Entered Idle State 01753 12/01/2025 01:10:13 Current Sensor Zeroed old: 2506mV, new: 2507mV, corrfact: 249 01754 12/01/2025 01:10:14 Discharge level 000 AH, SOC:100%, I: 0A, L:4145, l:4141, H:4147, B:002, PT:022C, BT:034C, PV:116095, M:Idle 01755 12/01/2025 01:10:14 SOC:0,63559,0,114800,100,100,100,-5 01756 12/01/2025 01:10:34 Voltage Across Contactor: 103184mV (Okay) 01757 12/01/2025 07:58:56 System Turned On 01758 12/01/2025 07:58:56 Rev:45,Build:2023-05-20_045619 958 banka 01759 12/01/2025 07:58:56 Pack:2019_monolith,Numbricks:4 01760 12/01/2025 07:58:56 DEBUG: Entered Charging State 01761 12/01/2025 07:58:56 DEBUG: CAN NOT Receiving Syncs 01762 12/01/2025 07:58:57 DEBUG: Entered Running State 01763 12/01/2025 07:58:57 DEBUG: CAN Link Is Up 01764 12/01/2025 07:58:57 DEBUG: Resetting CAN0 due to error passive mode 01765 12/01/2025 07:58:58 Discharge level 000 AH, SOC:100%, I: 0A, L:4119, l:4115, H:4121, B:002, PT:018C, BT:022C, PV:115370, M:Bike On 01766 12/01/2025 07:58:58 SOC:1,63559,0,114800,100,99,100,-4 01767 12/01/2025 07:59:00 DEBUG: CAN Receiving Syncs 01768 12/01/2025 07:59:01 Contactor drive turned on Pack V: 115320mV, Switched V: 100982mV, Duty Cycle: 34% 01769 12/01/2025 07:59:01 Contactor was Closed Pack V: 115320mV, Switched V: 100982mV, Prechg Pct: 88%, Dischg Cur: 818mA 01770 12/01/2025 07:59:58 Discharge level 000 AH, SOC:100%, I: 1A, L:4117, l:4117, H:4119, B:002, PT:018C, BT:023C, PV:115308, M:Bike On 01771 12/01/2025 07:59:58 SOC:32,63438,14,114800,100,99,100,0 01772 12/01/2025 08:00:58 Discharge level 000 AH, SOC:100%, I: 1A, L:4117, l:4117, H:4119, B:002, PT:018C, BT:022C, PV:115295, M:Bike On 01773 12/01/2025 08:00:58 SOC:62,63317,29,114800,100,99,100,0 01774 12/01/2025 08:01:58 Discharge level 000 AH, SOC:100%, I: 1A, L:4117, l:4117, H:4118, B:001, PT:018C, BT:022C, PV:115288, M:Bike On 01775 12/01/2025 08:01:58 SOC:90,63202,44,114800,100,99,100,0 01776 12/01/2025 08:02:58 Discharge level 000 AH, SOC:100%, I: 2A, L:4077, l:4086, H:4083, B:006, PT:018C, BT:024C, PV:114246, M:Bike On 01777 12/01/2025 08:02:58 SOC:275,62904,208,114800,100,96,100,9 01778 12/01/2025 08:03:58 Discharge level 000 AH, SOC:100%, I: 1A, L:4106, l:4110, H:4109, B:003, PT:018C, BT:023C, PV:115035, M:Bike On 01779 12/01/2025 08:03:58 SOC:382,62661,313,114800,100,99,100,5 01780 12/01/2025 08:04:58 Discharge level 000 AH, SOC: 99%, I: 2A, L:4080, l:4111, H:4086, B:006, PT:018C, BT:023C, PV:114350, M:Bike On 01781 12/01/2025 08:04:58 SOC:1052,61647,974,114800,100,99,99,32 01782 12/01/2025 08:05:58 Discharge level 002 AH, SOC: 96%, I:145A, L:3795, l:3996, H:3841, B:046, PT:019C, BT:023C, PV:106952, M:Bike On 01783 12/01/2025 08:05:58 SOC:2568,60017,2484,114800,98,87,96,206 01784 12/01/2025 08:06:58 Discharge level 003 AH, SOC: 95%, I: 53A, L:3923, l:4004, H:3947, B:024, PT:019C, BT:023C, PV:110198, M:Bike On 01785 12/01/2025 08:06:58 SOC:3330,59181,3237,114800,98,88,95,89 01786 12/01/2025 08:07:58 Discharge level 004 AH, SOC: 93%, I: 1A, L:4003, l:4051, H:4014, B:011, PT:019C, BT:023C, PV:112275, M:Bike On 01787 12/01/2025 08:07:58 SOC:4453,58118,4398,114800,97,93,93,52 01788 12/01/2025 08:08:58 Discharge level 004 AH, SOC: 93%, I:112A, L:3883, l:3976, H:3916, B:033, PT:020C, BT:023C, PV:109227, M:Bike On 01789 12/01/2025 08:08:58 SOC:4564,57892,4565,114800,97,85,93,100 01790 12/01/2025 08:09:58 Discharge level 005 AH, SOC: 92%, I: 0A, L:4028, l:4063, H:4036, B:008, PT:020C, BT:023C, PV:112936, M:Bike On 01791 12/01/2025 08:09:58 SOC:4970,57433,5029,114800,96,94,92,40 01792 12/01/2025 08:10:58 Discharge level 005 AH, SOC: 91%, I: 1A, L:3963, l:4006, H:3983, B:020, PT:020C, BT:023C, PV:111338, M:Bike On 01793 12/01/2025 08:10:58 SOC:5364,57105,5458,114800,96,89,91,49 01794 12/01/2025 08:11:58 Discharge level 006 AH, SOC: 90%, I: 46A, L:3913, l:3976, H:3937, B:024, PT:020C, BT:024C, PV:109967, M:Bike On 01795 12/01/2025 08:11:58 SOC:5948,56584,6130,114800,95,86,90,72 01796 12/01/2025 08:12:58 Discharge level 007 AH, SOC: 88%, I: 1A, L:3973, l:4025, H:3985, B:012, PT:021C, BT:023C, PV:111464, M:Bike On 01797 12/01/2025 08:12:58 SOC:6824,56084,7013,114800,94,90,88,59 01798 12/01/2025 08:13:58 Discharge level 007 AH, SOC: 87%, I: 68A, L:3821, l:3913, H:3858, B:037, PT:021C, BT:024C, PV:107587, M:Bike On 01799 12/01/2025 08:13:58 SOC:7668,55617,7895,114800,94,80,87,103 01800 12/01/2025 08:14:58 Discharge level 008 AH, SOC: 86%, I: 1A, L:3978, l:4021, H:3990, B:012, PT:021C, BT:024C, PV:111610, M:Bike On 01801 12/01/2025 08:14:58 SOC:8214,55364,8502,114800,93,90,86,48 01802 12/01/2025 08:15:58 Discharge level 009 AH, SOC: 85%, I: 44A, L:3878, l:3947, H:3905, B:027, PT:021C, BT:024C, PV:109060, M:Bike On 01803 12/01/2025 08:15:58 SOC:8814,55132,9180,114800,93,83,85,82 01804 12/01/2025 08:16:58 Discharge level 010 AH, SOC: 81%, I: 1A, L:3899, l:3975, H:3917, B:018, PT:022C, BT:023C, PV:109526, M:Bike On 01805 12/01/2025 08:16:58 SOC:10408,54426,10833,114800,91,86,81,90 01806 12/01/2025 08:17:58 Discharge level 013 AH, SOC: 75%, I:133A, L:3644, l:3857, H:3698, B:054, PT:023C, BT:024C, PV:102974, M:Bike On 01807 12/01/2025 08:17:58 SOC:13488,53394,13930,114800,88,74,75,255 01808 12/01/2025 08:18:58 Discharge level 016 AH, SOC: 70%, I:172A, L:3558, l:3805, H:3630, B:072, PT:024C, BT:024C, PV:100894, M:Bike On 01809 12/01/2025 08:18:58 SOC:16046,53171,16506,114800,86,68,70,295 01810 12/01/2025 08:19:58 Discharge level 018 AH, SOC: 66%, I:248A, L:3450, l:3732, H:3541, B:091, PT:025C, BT:023C, PV: 98242, M:Bike On 01811 12/01/2025 08:19:58 SOC:18235,53554,18703,114800,84,60,66,349 01812 12/01/2025 08:20:58 Discharge level 021 AH, SOC: 62%, I: 0A, L:3721, l:3869, H:3755, B:034, PT:026C, BT:024C, PV:104877, M:Bike On 01813 12/01/2025 08:20:58 SOC:20779,53914,21281,114800,82,75,62,191 01814 12/01/2025 08:20:58 Discharge cutback 83% 01815 12/01/2025 08:20:58 712A 01816 12/01/2025 08:21:58 Discharge level 023 AH, SOC: 58%, I:185A, L:3480, l:3716, H:3562, B:082, PT:027C, BT:024C, PV: 99012, M:Bike On 01817 12/01/2025 08:21:58 SOC:23204,54384,23749,114800,80,57,58,321 01818 12/01/2025 08:21:58 Discharge cutback 82% 01819 12/01/2025 08:21:58 709A 01820 12/01/2025 08:22:58 Discharge level 026 AH, SOC: 53%, I:126A, L:3568, l:3743, H:3630, B:062, PT:029C, BT:025C, PV:101117, M:Bike On 01821 12/01/2025 08:22:58 SOC:25953,54968,26548,114800,77,61,53,253 01822 12/01/2025 08:22:58 Discharge cutback 85% 01823 12/01/2025 08:22:58 729A 01824 12/01/2025 08:23:58 Discharge level 029 AH, SOC: 49%, I:261A, L:3390, l:3643, H:3490, B:100, PT:030C, BT:024C, PV: 96884, M:Bike On 01825 12/01/2025 08:23:58 SOC:28793,55605,29404,114800,75,45,49,387 01826 12/01/2025 08:23:58 Discharge cutback 74% 01827 12/01/2025 08:23:58 634A 01828 12/01/2025 08:24:58 Discharge level 032 AH, SOC: 44%, I:247A, L:3376, l:3625, H:3477, B:101, PT:031C, BT:025C, PV: 96545, M:Bike On 01829 12/01/2025 08:24:58 SOC:31805,56086,32442,114800,72,42,44,402 01830 12/01/2025 08:24:58 Discharge cutback 61% 01831 12/01/2025 08:24:58 523A 01832 12/01/2025 08:25:58 Discharge level 035 AH, SOC: 39%, I:309A, L:3322, l:3585, H:3433, B:111, PT:032C, BT:025C, PV: 95241, M:Bike On 01833 12/01/2025 08:25:58 SOC:34542,56609,35301,114800,70,33,39,442 01834 12/01/2025 08:25:58 Discharge cutback 60% 01835 12/01/2025 08:25:58 519A 01836 12/01/2025 08:26:58 Discharge level 038 AH, SOC: 33%, I:-44A, L:3594, l:3702, H:3629, B:035, PT:034C, BT:025C, PV:101403, M:Bike On 01837 12/01/2025 08:26:58 SOC:38134,56809,38962,114800,67,57,33,195 01838 12/01/2025 08:26:58 Discharge cutback 56% 01839 12/01/2025 08:26:58 486A 01840 12/01/2025 08:27:58 Discharge level 039 AH, SOC: 34%, I: 34A, L:3601, l:3674, H:3638, B:037, PT:034C, BT:025C, PV:101624, M:Bike On 01841 12/01/2025 08:27:58 SOC:38050,57642,39713,114800,66,53,34,132 01842 12/01/2025 08:27:58 Discharge cutback 79% 01843 12/01/2025 08:27:58 678A 01844 12/01/2025 08:28:58 Discharge level 040 AH, SOC: 36%, I: 0A, L:3643, l:3683, H:3670, B:027, PT:035C, BT:026C, PV:102611, M:Bike On 01845 12/01/2025 08:28:58 SOC:37870,59124,40151,114800,66,55,36,75 01846 12/01/2025 08:28:58 Discharge cutback 86% 01847 12/01/2025 08:28:58 742A 01848 12/01/2025 08:29:58 Discharge level 041 AH, SOC: 37%, I:216A, L:3486, l:3609, H:3548, B:062, PT:035C, BT:025C, PV: 98877, M:Bike On 01849 12/01/2025 08:29:58 SOC:38385,60268,41203,114800,65,42,37,228 01850 12/01/2025 08:29:58 Discharge cutback 82% 01851 12/01/2025 08:29:58 709A 01852 12/01/2025 08:30:58 Discharge level 041 AH, SOC: 38%, I:-14A, L:3654, l:3683, H:3674, B:020, PT:035C, BT:025C, PV:102758, M:Bike On 01853 12/01/2025 08:30:58 SOC:38082,60727,41789,114800,64,55,38,54 01854 12/01/2025 08:30:58 Discharge cutback 84% 01855 12/01/2025 08:30:58 722A 01856 12/01/2025 08:31:58 Discharge level 041 AH, SOC: 40%, I: 1A, L:3658, l:3678, H:3677, B:019, PT:035C, BT:027C, PV:102861, M:Bike On 01857 12/01/2025 08:31:58 SOC:37684,61882,41954,114800,64,54,40,37 01858 12/01/2025 08:32:58 Discharge level 041 AH, SOC: 41%, I: 0A, L:3668, l:3681, H:3684, B:016, PT:035C, BT:027C, PV:103077, M:Bike On 01859 12/01/2025 08:32:58 SOC:37272,63128,41971,114800,64,55,41,24 01860 12/01/2025 08:33:07 Contactor was Opened Pack V: 103103mV, Switched V: 103030mV, Prechg Pct: 100%, Dischg Cur: 636mA 01861 12/01/2025 08:33:08 System Turned Off 01862 12/01/2025 08:33:08 DEBUG: CAN Link Is Down 01863 12/01/2025 08:33:08 DEBUG: Entered Idle State 01864 12/01/2025 08:33:14 Current Sensor Zeroed old: 2507mV, new: 2504mV, corrfact: 252 01865 12/01/2025 08:33:16 Discharge level 041 AH, SOC: 42%, I: 0A, L:3670, l:3681, H:3687, B:017, PT:035C, BT:026C, PV:103133, M:Idle 01866 12/01/2025 08:33:16 SOC:37187,63309,41972,114800,64,55,42,22 01867 12/01/2025 08:33:37 Voltage Across Contactor: 89513mV (Okay) 01868 12/01/2025 09:29:26 System Turned On 01869 12/01/2025 09:29:26 Rev:45,Build:2023-05-20_045619 958 banka 01870 12/01/2025 09:29:26 Pack:2019_monolith,Numbricks:4 01871 12/01/2025 09:29:26 DEBUG: Entered Running State 01872 12/01/2025 09:29:26 DEBUG: CAN NOT Receiving Syncs 01873 12/01/2025 09:29:26 DEBUG: CAN Link Is Up 01874 12/01/2025 09:29:27 DEBUG: Resetting CAN0 due to error passive mode 01875 12/01/2025 09:29:27 Discharge level 041 AH, SOC: 42%, I: 0A, L:3703, l:3715, H:3707, B:004, PT:032C, BT:031C, PV:103744, M:Bike On 01876 12/01/2025 09:29:27 SOC:37176,63309,41972,114800,64,59,42,22 01877 12/01/2025 09:29:30 DEBUG: CAN Receiving Syncs 01878 12/01/2025 09:29:30 Contactor drive turned on Pack V: 103741mV, Switched V: 90820mV, Duty Cycle: 38% 01879 12/01/2025 09:29:30 Contactor was Closed Pack V: 103741mV, Switched V: 90820mV, Prechg Pct: 88%, Dischg Cur: 636mA 01880 12/01/2025 09:30:27 Discharge level 041 AH, SOC: 44%, I: 1A, L:3701, l:3711, H:3706, B:005, PT:032C, BT:031C, PV:103713, M:Bike On 01881 12/01/2025 09:30:27 SOC:37071,65859,41998,114800,64,59,44,17 01882 12/01/2025 09:31:27 Discharge level 042 AH, SOC: 45%, I:-23A, L:3703, l:3714, H:3708, B:005, PT:032C, BT:031C, PV:103759, M:Bike On 01883 12/01/2025 09:31:27 SOC:37111,67152,42441,114800,64,59,45,21 01884 12/01/2025 09:32:27 Discharge level 042 AH, SOC: 46%, I: 1A, L:3687, l:3698, H:3694, B:007, PT:032C, BT:031C, PV:103371, M:Bike On 01885 12/01/2025 09:32:27 SOC:36422,67369,42602,114800,63,57,46,19 01886 12/01/2025 09:33:27 Discharge level 043 AH, SOC: 47%, I: 64A, L:3631, l:3668, H:3648, B:017, PT:032C, BT:031C, PV:101994, M:Bike On 01887 12/01/2025 09:33:27 SOC:36421,67981,43038,114800,63,52,47,65 01888 12/01/2025 09:34:27 Discharge level 043 AH, SOC: 47%, I: 1A, L:3664, l:3686, H:3676, B:012, PT:032C, BT:030C, PV:102850, M:Bike On 01889 12/01/2025 09:34:27 SOC:36383,68602,43369,114800,63,55,47,38 01890 12/01/2025 09:35:27 Discharge level 044 AH, SOC: 47%, I: 1A, L:3660, l:3679, H:3671, B:011, PT:032C, BT:031C, PV:102698, M:Bike On 01891 12/01/2025 09:35:27 SOC:36832,68610,44159,114800,62,54,47,33 01892 12/01/2025 09:35:27 Discharge cutback 88% 01893 12/01/2025 09:35:27 759A 01894 12/01/2025 09:36:27 Discharge level 044 AH, SOC: 47%, I: 1A, L:3662, l:3677, H:3673, B:011, PT:032C, BT:030C, PV:102762, M:Bike On 01895 12/01/2025 09:36:27 SOC:36910,69479,44393,114800,62,54,47,27 01896 12/01/2025 09:37:27 Discharge level 044 AH, SOC: 48%, I: 80A, L:3591, l:3635, H:3619, B:028, PT:032C, BT:030C, PV:101116, M:Bike On 01897 12/01/2025 09:37:27 SOC:36960,70088,44657,114800,62,47,48,77 01898 12/01/2025 09:38:27 Discharge level 044 AH, SOC: 48%, I: 1A, L:3664, l:3673, H:3675, B:011, PT:032C, BT:030C, PV:102815, M:Bike On 01899 12/01/2025 09:38:27 SOC:37018,70796,44842,114800,61,53,48,17 01900 12/01/2025 09:38:52 Contactor was Opened Pack V: 102881mV, Switched V: 102833mV, Prechg Pct: 100%, Dischg Cur: 1546mA 01901 12/01/2025 09:38:52 System Turned Off 01902 12/01/2025 09:38:53 DEBUG: CAN Link Is Down 01903 12/01/2025 09:38:53 DEBUG: Entered Idle State 01904 12/01/2025 09:38:59 Current Sensor Zeroed old: 2504mV, new: 2507mV, corrfact: 249 01905 12/01/2025 09:39:01 Discharge level 044 AH, SOC: 49%, I: 0A, L:3668, l:3675, H:3679, B:011, PT:032C, BT:029C, PV:102926, M:Idle 01906 12/01/2025 09:39:01 SOC:37023,71238,44852,114800,61,54,49,12 01907 12/01/2025 09:39:22 Voltage Across Contactor: 89895mV (Okay) 01908 12/01/2025 11:04:47 System Turned On 01909 12/01/2025 11:04:47 Rev:45,Build:2023-05-20_045619 958 banka 01910 12/01/2025 11:04:47 Pack:2019_monolith,Numbricks:4 01911 12/01/2025 11:04:47 DEBUG: Entered Running State 01912 12/01/2025 11:04:47 DEBUG: CAN NOT Receiving Syncs 01913 12/01/2025 11:04:47 DEBUG: CAN Link Is Up 01914 12/01/2025 11:04:48 DEBUG: Resetting CAN0 due to error passive mode 01915 12/01/2025 11:04:48 Discharge level 044 AH, SOC: 49%, I: 0A, L:3685, l:3693, H:3689, B:004, PT:026C, BT:026C, PV:103256, M:Bike On 01916 12/01/2025 11:04:48 SOC:37017,71238,44852,114800,61,56,49,12 01917 12/01/2025 11:04:51 DEBUG: CAN Receiving Syncs 01918 12/01/2025 11:04:51 Contactor drive turned on Pack V: 103236mV, Switched V: 90427mV, Duty Cycle: 39% 01919 12/01/2025 11:04:51 Contactor was Closed Pack V: 103236mV, Switched V: 90427mV, Prechg Pct: 88%, Dischg Cur: 909mA 01920 12/01/2025 11:05:48 Discharge level 044 AH, SOC: 49%, I: 1A, L:3683, l:3689, H:3689, B:006, PT:026C, BT:025C, PV:103223, M:Bike On 01921 12/01/2025 11:05:48 SOC:36877,72282,44868,114800,61,56,49,8 01922 12/01/2025 11:06:48 Discharge level 044 AH, SOC: 50%, I: 1A, L:3682, l:3686, H:3688, B:006, PT:026C, BT:025C, PV:103216, M:Bike On 01923 12/01/2025 11:06:48 SOC:36790,73183,44885,114800,61,55,50,6 01924 12/01/2025 11:07:48 Discharge level 045 AH, SOC: 50%, I:103A, L:3560, l:3622, H:3590, B:030, PT:026C, BT:025C, PV:100250, M:Bike On 01925 12/01/2025 11:07:48 SOC:36789,73277,45169,114800,61,45,50,88 01926 12/01/2025 11:07:48 Discharge cutback 89% 01927 12/01/2025 11:07:48 769A 01928 12/01/2025 11:08:48 Discharge level 045 AH, SOC: 50%, I: 1A, L:3664, l:3677, H:3672, B:008, PT:026C, BT:025C, PV:102769, M:Bike On 01929 12/01/2025 11:08:48 SOC:36875,73388,45454,114800,61,54,50,19 01930 12/01/2025 11:09:48 Discharge level 045 AH, SOC: 50%, I:-33A, L:3683, l:3693, H:3690, B:007, PT:026C, BT:025C, PV:103228, M:Bike On 01931 12/01/2025 11:09:48 SOC:37217,73432,45893,114800,61,56,50,14 01932 12/01/2025 11:09:48 Discharge cutback 84% 01933 12/01/2025 11:09:48 725A 01934 12/01/2025 11:10:48 Discharge level 046 AH, SOC: 50%, I: 1A, L:3639, l:3660, H:3651, B:012, PT:026C, BT:025C, PV:102149, M:Bike On 01935 12/01/2025 11:10:48 SOC:37349,73342,46222,114800,60,51,50,29 01936 12/01/2025 11:10:48 Discharge cutback 87% 01937 12/01/2025 11:10:48 746A 01938 12/01/2025 11:11:48 Discharge level 046 AH, SOC: 48%, I: 1A, L:3635, l:3661, H:3645, B:010, PT:026C, BT:025C, PV:102007, M:Bike On 01939 12/01/2025 11:11:48 SOC:38017,72961,46968,114800,60,52,48,37 01940 12/01/2025 11:11:48 Discharge cutback 81% 01941 12/01/2025 11:11:48 698A 01942 12/01/2025 11:12:48 Discharge level 047 AH, SOC: 48%, I: 28A, L:3613, l:3653, H:3629, B:016, PT:026C, BT:025C, PV:101491, M:Bike On 01943 12/01/2025 11:12:48 SOC:38286,72980,47328,114800,59,50,48,54 01944 12/01/2025 11:12:48 Discharge cutback 82% 01945 12/01/2025 11:12:48 702A 01946 12/01/2025 11:13:48 Discharge level 047 AH, SOC: 48%, I: 1A, L:3640, l:3655, H:3650, B:010, PT:026C, BT:025C, PV:102149, M:Bike On 01947 12/01/2025 11:13:48 SOC:38352,72859,47592,114800,59,51,48,21 01948 12/01/2025 11:13:48 Discharge cutback 84% 01949 12/01/2025 11:13:48 725A 01950 12/01/2025 11:14:48 Discharge level 047 AH, SOC: 48%, I: 1A, L:3648, l:3656, H:3658, B:010, PT:026C, BT:025C, PV:102351, M:Bike On 01951 12/01/2025 11:14:48 SOC:38314,73371,47614,114800,59,51,48,12 01952 12/01/2025 11:14:48 Discharge cutback 89% 01953 12/01/2025 11:14:48 763A 01954 12/01/2025 11:15:11 Contactor was Opened Pack V: 102428mV, Switched V: 102400mV, Prechg Pct: 100%, Dischg Cur: 636mA 01955 12/01/2025 11:15:12 System Turned Off 01956 12/01/2025 11:15:12 DEBUG: CAN Link Is Down 01957 12/01/2025 11:15:12 DEBUG: Entered Idle State 01958 12/01/2025 11:15:18 Current Sensor Zeroed old: 2507mV, new: 2504mV, corrfact: 252 01959 12/01/2025 11:15:20 Discharge level 047 AH, SOC: 48%, I: 0A, L:3652, l:3658, H:3662, B:010, PT:026C, BT:025C, PV:102464, M:Idle 01960 12/01/2025 11:15:20 SOC:38295,73550,47622,114800,59,51,48,9 01961 12/01/2025 11:15:23 System Turned On 01962 12/01/2025 11:15:23 Rev:45,Build:2023-05-20_045619 958 banka 01963 12/01/2025 11:15:23 Pack:2019_monolith,Numbricks:4 01964 12/01/2025 11:15:23 DEBUG: Entered Running State 01965 12/01/2025 11:15:23 DEBUG: CAN NOT Receiving Syncs 01966 12/01/2025 11:15:24 DEBUG: CAN Link Is Up 01967 12/01/2025 11:15:24 DEBUG: Resetting CAN0 due to error passive mode 01968 12/01/2025 11:15:25 Discharge level 047 AH, SOC: 48%, I: 0A, L:3653, l:3659, H:3662, B:009, PT:026C, BT:025C, PV:102462, M:Bike On 01969 12/01/2025 11:15:25 SOC:38292,73550,47622,114800,59,51,48,9 01970 12/01/2025 11:15:28 DEBUG: CAN Receiving Syncs 01971 12/01/2025 11:15:28 Contactor drive turned on Pack V: 102460mV, Switched V: 90230mV, Duty Cycle: 39% 01972 12/01/2025 11:15:28 Contactor was Closed Pack V: 102460mV, Switched V: 90230mV, Prechg Pct: 88%, Dischg Cur: 636mA 01973 12/01/2025 11:15:30 DEBUG: Entered Charging State 01974 12/01/2025 11:15:30 DEBUG: CAN NOT Receiving Syncs 01975 12/01/2025 11:15:31 Discharge level 047 AH, SOC: 48%, I: 0A, L:3653, l:3659, H:3662, B:009, PT:026C, BT:025C, PV:102467, M:Charge 01976 12/01/2025 11:15:31 SOC:38275,73556,47622,114800,59,51,48,9 01977 12/01/2025 11:15:31 DEBUG: CAN Receiving Syncs 01978 12/01/2025 11:25:31 Discharge level 045 AH, SOC: 55%, I:-12A, L:3705, l:3689, H:3711, B:006, PT:026C, BT:032C, PV:103830, M:Charge 01979 12/01/2025 11:25:31 SOC:31102,68373,45670,114800,61,56,55,-21 01980 12/01/2025 11:35:31 Discharge level 043 AH, SOC: 59%, I:-12A, L:3723, l:3706, H:3729, B:006, PT:025C, BT:037C, PV:104354, M:Charge 01981 12/01/2025 11:35:31 SOC:28284,67539,43702,114800,62,58,59,-22 01982 12/01/2025 11:45:31 Discharge level 041 AH, SOC: 61%, I:-11A, L:3740, l:3724, H:3747, B:007, PT:025C, BT:036C, PV:104823, M:Charge 01983 12/01/2025 11:45:31 SOC:26648,67873,41748,114800,64,60,61,-21 01984 12/01/2025 11:55:39 Discharge level 039 AH, SOC: 63%, I:-11A, L:3757, l:3740, H:3765, B:008, PT:025C, BT:037C, PV:105305, M:Charge 01985 12/01/2025 11:55:39 SOC:25580,68788,39781,114800,66,62,63,-22 01986 12/01/2025 12:05:39 Discharge level 037 AH, SOC: 65%, I:-11A, L:3774, l:3757, H:3783, B:009, PT:025C, BT:039C, PV:105780, M:Charge 01987 12/01/2025 12:05:39 SOC:24438,69625,37818,114800,68,65,65,-21 01988 12/01/2025 12:15:39 Discharge level 035 AH, SOC: 67%, I:-11A, L:3792, l:3775, H:3803, B:011, PT:025C, BT:039C, PV:106301, M:Charge 01989 12/01/2025 12:15:39 SOC:23377,70498,35900,114800,69,66,67,-22 01990 12/01/2025 12:25:39 Discharge level 033 AH, SOC: 69%, I:-12A, L:3811, l:3794, H:3822, B:011, PT:025C, BT:038C, PV:106832, M:Charge 01991 12/01/2025 12:25:39 SOC:22231,71300,33968,114800,71,69,69,-22 01992 12/01/2025 12:35:39 Discharge level 032 AH, SOC: 71%, I:-11A, L:3831, l:3814, H:3843, B:012, PT:025C, BT:038C, PV:107387, M:Charge 01993 12/01/2025 12:35:39 SOC:20856,71851,32059,114800,73,71,71,-21 01994 12/01/2025 12:45:39 Discharge level 030 AH, SOC: 74%, I:-11A, L:3853, l:3836, H:3864, B:011, PT:025C, BT:038C, PV:107986, M:Charge 01995 12/01/2025 12:45:39 SOC:19439,72332,30179,114800,74,73,74,-21 01996 12/01/2025 12:55:39 Discharge level 028 AH, SOC: 76%, I:-11A, L:3876, l:3860, H:3885, B:009, PT:025C, BT:038C, PV:108626, M:Charge 01997 12/01/2025 12:55:39 SOC:17894,72684,28299,114800,76,75,76,-21 01998 12/01/2025 13:05:47 Discharge level 026 AH, SOC: 78%, I:-11A, L:3900, l:3884, H:3905, B:005, PT:025C, BT:039C, PV:109272, M:Charge 01999 12/01/2025 13:05:47 SOC:16321,73015,26413,114800,77,78,78,-21 02000 12/01/2025 13:15:47 Discharge level 024 AH, SOC: 80%, I:-10A, L:3922, l:3906, H:3925, B:003, PT:025C, BT:042C, PV:109870, M:Charge 02001 12/01/2025 13:15:47 SOC:14691,73270,24544,114800,79,80,80,-20 02002 12/01/2025 13:25:47 Discharge level 022 AH, SOC: 82%, I:-10A, L:3942, l:3927, H:3946, B:004, PT:025C, BT:040C, PV:110435, M:Charge 02003 12/01/2025 13:25:47 SOC:13556,73966,22731,114800,81,81,82,-20 02004 12/01/2025 13:35:47 Discharge level 020 AH, SOC: 84%, I:-11A, L:3960, l:3944, H:3964, B:004, PT:025C, BT:041C, PV:110954, M:Charge 02005 12/01/2025 13:35:47 SOC:12279,74516,20922,114800,82,83,84,-20 02006 12/01/2025 13:45:47 Discharge level 019 AH, SOC: 86%, I:-11A, L:3980, l:3964, H:3983, B:003, PT:025C, BT:039C, PV:111503, M:Charge 02007 12/01/2025 13:45:47 SOC:11010,75087,19099,114800,84,85,86,-21 02008 12/01/2025 13:55:47 Discharge level 017 AH, SOC: 87%, I:-11A, L:3999, l:3983, H:4003, B:004, PT:025C, BT:035C, PV:112047, M:Charge 02009 12/01/2025 13:55:47 SOC:9908,75833,17267,114800,85,87,87,-21 02010 12/01/2025 14:05:47 Discharge level 015 AH, SOC: 89%, I:-11A, L:4018, l:4002, H:4021, B:003, PT:025C, BT:032C, PV:112545, M:Charge 02011 12/01/2025 14:05:47 SOC:8691,76447,15453,114800,87,88,89,-20 02012 12/01/2025 14:09:00 Charged To Full 014 AH, SOC: 90%, L:4025, H:4028, B:003, PT:025C, BT:031C, PV:112741 02013 12/01/2025 14:09:00 SOC adjusted for voltage old: 8144726uAH (soc:90%), new: 7649202uAH (soc:90%), low cell: 4025 mV 02014 12/01/2025 14:15:47 Discharge level 010 AH, SOC: 91%, I:-10A, L:4037, l:4022, H:4040, B:003, PT:025C, BT:031C, PV:113084, M:Charge 02015 12/01/2025 14:15:47 SOC:7218,77297,10254,114800,92,90,91,-20 02016 12/01/2025 14:25:47 Discharge level 008 AH, SOC: 93%, I:-11A, L:4057, l:4042, H:4059, B:002, PT:025C, BT:030C, PV:113626, M:Charge 02017 12/01/2025 14:25:47 SOC:5934,77837,8448,114800,93,92,93,-20 02018 12/01/2025 14:35:55 Discharge level 006 AH, SOC: 95%, I:-11A, L:4076, l:4061, H:4080, B:004, PT:024C, BT:033C, PV:114176, M:Charge 02019 12/01/2025 14:35:55 SOC:4551,78283,6637,114800,95,94,95,-20 02020 12/01/2025 14:45:55 Discharge level 004 AH, SOC: 97%, I:-10A, L:4096, l:4081, H:4099, B:003, PT:024C, BT:034C, PV:114724, M:Charge 02021 12/01/2025 14:45:55 SOC:3117,78654,4850,114800,96,96,97,-20 02022 12/01/2025 15:27:16 DEBUG: CAN Link Is Down 02023 12/01/2025 15:27:20 DEBUG: CAN Link Is Up 02024 12/01/2025 15:27:20 Contactor was Opened Pack V: 116051mV, Switched V: 116066mV, Prechg Pct: 100%, Dischg Cur: 363mA 02025 12/01/2025 15:27:22 System Turned Off 02026 12/01/2025 15:27:23 DEBUG: CAN Link Is Down 02027 12/01/2025 15:27:23 DEBUG: Entered Idle State 02028 12/01/2025 15:27:30 Discharge level 000 AH, SOC:100%, I: 0A, L:4146, l:4143, H:4149, B:003, PT:024C, BT:034C, PV:116140, M:Idle 02029 12/01/2025 15:27:30 SOC:0,79294,0,114800,100,100,100,-4 02030 12/01/2025 15:27:50 Voltage Across Contactor: 103280mV (Okay) 02031 12/01/2025 22:24:04 System Turned On 02032 12/01/2025 22:24:04 Rev:45,Build:2023-05-20_045619 958 banka 02033 12/01/2025 22:24:04 Pack:2019_monolith,Numbricks:4 02034 12/01/2025 22:24:04 DEBUG: Entered Charging State 02035 12/01/2025 22:24:04 DEBUG: CAN NOT Receiving Syncs 02036 12/01/2025 22:24:05 DEBUG: CAN Link Is Up 02037 12/01/2025 22:24:05 DEBUG: Entered Running State 02038 12/01/2025 22:24:05 DEBUG: Resetting CAN0 due to error passive mode 02039 12/01/2025 22:24:06 Discharge level 000 AH, SOC:100%, I: 0A, L:4118, l:4115, H:4122, B:004, PT:018C, BT:025C, PV:115361, M:Bike On 02040 12/01/2025 22:24:06 SOC:1,79294,0,114800,100,99,100,-4 02041 12/01/2025 22:24:08 DEBUG: CAN Receiving Syncs 02042 12/01/2025 22:24:13 Contactor drive turned on Pack V: 115350mV, Switched V: 101848mV, Duty Cycle: 34% 02043 12/01/2025 22:24:13 Contactor was Closed Pack V: 115350mV, Switched V: 101848mV, Prechg Pct: 88%, Dischg Cur: 363mA 02044 12/01/2025 22:25:06 Discharge level 000 AH, SOC:100%, I: 1A, L:4116, l:4116, H:4118, B:002, PT:018C, BT:025C, PV:115283, M:Bike On 02045 12/01/2025 22:25:06 SOC:64,79237,8,114800,100,99,100,0 02046 12/01/2025 22:26:06 Discharge level 000 AH, SOC:100%, I: 71A, L:3949, l:4012, H:3975, B:026, PT:018C, BT:025C, PV:110986, M:Bike On 02047 12/01/2025 22:26:06 SOC:321,78661,262,114800,100,89,100,65 02048 12/01/2025 22:27:06 Discharge level 000 AH, SOC: 99%, I: 1A, L:4067, l:4099, H:4075, B:008, PT:018C, BT:025C, PV:114015, M:Bike On 02049 12/01/2025 22:27:06 SOC:925,77417,874,114800,100,97,99,33 02050 12/01/2025 22:28:06 Discharge level 001 AH, SOC: 99%, I: 40A, L:4036, l:4084, H:4049, B:013, PT:018C, BT:024C, PV:113229, M:Bike On 02051 12/01/2025 22:28:06 SOC:1190,76679,1162,114800,99,96,99,49 02052 12/01/2025 22:29:06 Discharge level 001 AH, SOC: 98%, I: 0A, L:4070, l:4096, H:4078, B:008, PT:018C, BT:024C, PV:114099, M:Bike On 02053 12/01/2025 22:29:06 SOC:1567,75720,1590,114800,99,97,98,27 02054 12/01/2025 22:30:06 Discharge level 002 AH, SOC: 97%, I: 1A, L:4039, l:4082, H:4049, B:010, PT:019C, BT:024C, PV:113260, M:Bike On 02055 12/01/2025 22:30:06 SOC:2457,74260,2513,114800,98,96,97,44 02056 12/01/2025 22:31:06 Discharge level 004 AH, SOC: 95%, I:-43A, L:3912, l:3992, H:3938, B:026, PT:019C, BT:024C, PV:109919, M:Bike On 02057 12/01/2025 22:31:06 SOC:3982,72084,4104,114800,97,87,95,87 02058 12/01/2025 22:32:06 Discharge level 006 AH, SOC: 92%, I:-36A, L:3995, l:4072, H:4004, B:009, PT:021C, BT:024C, PV:112048, M:Bike On 02059 12/01/2025 22:32:06 SOC:5988,69669,6150,114800,95,94,92,83 02060 12/01/2025 22:33:06 Discharge level 007 AH, SOC: 90%, I:293A, L:3508, l:3775, H:3597, B:089, PT:022C, BT:023C, PV: 99715, M:Bike On 02061 12/01/2025 22:33:06 SOC:6900,68543,7080,114800,94,64,90,303 02062 12/01/2025 22:34:06 Discharge level 010 AH, SOC: 85%, I:175A, L:3617, l:3860, H:3688, B:071, PT:023C, BT:023C, PV:102562, M:Bike On 02063 12/01/2025 22:34:06 SOC:9988,65825,10168,114800,92,75,85,291 02064 12/01/2025 22:35:06 Discharge level 012 AH, SOC: 81%, I:157A, L:3592, l:3836, H:3669, B:077, PT:024C, BT:022C, PV:102048, M:Bike On 02065 12/01/2025 22:35:06 SOC:12648,64099,12831,114800,89,72,81,297 02066 12/01/2025 22:36:06 Discharge level 015 AH, SOC: 77%, I:108A, L:3668, l:3848, H:3729, B:061, PT:025C, BT:022C, PV:103900, M:Bike On 02067 12/01/2025 22:36:06 SOC:15105,63017,15308,114800,87,73,77,223 02068 12/01/2025 22:37:06 Discharge level 018 AH, SOC: 71%, I:251A, L:3471, l:3762, H:3573, B:102, PT:027C, BT:022C, PV: 99221, M:Bike On 02069 12/01/2025 22:37:06 SOC:18239,62024,18445,114800,84,63,71,370 02070 12/01/2025 22:38:06 Discharge level 019 AH, SOC: 69%, I:228A, L:3535, l:3767, H:3623, B:088, PT:028C, BT:023C, PV:100735, M:Bike On 02071 12/01/2025 22:38:06 SOC:19613,61977,19982,114800,83,64,69,305 02072 12/01/2025 22:39:06 Discharge level 021 AH, SOC: 66%, I: 1A, L:3719, l:3847, H:3760, B:041, PT:029C, BT:023C, PV:105018, M:Bike On 02073 12/01/2025 22:39:06 SOC:21519,61997,21964,114800,81,73,66,170 02074 12/01/2025 22:40:06 Discharge level 022 AH, SOC: 65%, I: 2A, L:3766, l:3838, H:3795, B:029, PT:029C, BT:023C, PV:106095, M:Bike On 02075 12/01/2025 22:40:06 SOC:21998,61886,22916,114800,81,72,65,99 02076 12/01/2025 22:41:06 Discharge level 023 AH, SOC: 65%, I: 51A, L:3751, l:3817, H:3784, B:033, PT:030C, BT:022C, PV:105742, M:Bike On 02077 12/01/2025 22:41:06 SOC:21883,62288,23209,114800,80,70,65,90 02078 12/01/2025 22:42:06 Discharge level 023 AH, SOC: 66%, I:-10A, L:3812, l:3843, H:3830, B:018, PT:030C, BT:024C, PV:107132, M:Bike On 02079 12/01/2025 22:42:06 SOC:21861,62469,23638,114800,80,73,66,43 02080 12/01/2025 22:43:06 Discharge level 024 AH, SOC: 65%, I:226A, L:3563, l:3703, H:3644, B:081, PT:030C, BT:023C, PV:101431, M:Bike On 02081 12/01/2025 22:43:06 SOC:22041,62975,24062,114800,80,56,65,200 02082 12/01/2025 22:44:06 Discharge level 025 AH, SOC: 64%, I:251A, L:3549, l:3716, H:3629, B:080, PT:030C, BT:023C, PV:100995, M:Bike On 02083 12/01/2025 22:44:06 SOC:23055,62973,25255,114800,79,58,64,239 02084 12/01/2025 22:45:06 Discharge level 026 AH, SOC: 61%, I: 0A, L:3747, l:3807, H:3768, B:021, PT:031C, BT:024C, PV:105378, M:Bike On 02085 12/01/2025 22:45:06 SOC:24482,62684,26837,114800,77,69,61,87 02086 12/01/2025 22:45:06 Discharge cutback 89% 02087 12/01/2025 22:45:06 769A 02088 12/01/2025 22:46:06 Discharge level 028 AH, SOC: 60%, I:-25A, L:3746, l:3790, H:3767, B:021, PT:031C, BT:023C, PV:105354, M:Bike On 02089 12/01/2025 22:46:06 SOC:25408,62326,28068,114800,76,68,60,67 02090 12/01/2025 22:47:06 Discharge level 028 AH, SOC: 59%, I: 1A, L:3734, l:3782, H:3754, B:020, PT:032C, BT:025C, PV:104997, M:Bike On 02091 12/01/2025 22:47:06 SOC:25726,62022,28867,114800,75,67,59,74 02092 12/01/2025 22:48:06 Discharge level 029 AH, SOC: 59%, I: 0A, L:3749, l:3775, H:3768, B:019, PT:032C, BT:023C, PV:105385, M:Bike On 02093 12/01/2025 22:48:06 SOC:25677,62326,29181,114800,75,66,59,40 02094 12/01/2025 22:49:06 Discharge level 029 AH, SOC: 60%, I: 10A, L:3749, l:3772, H:3767, B:018, PT:032C, BT:025C, PV:105356, M:Bike On 02095 12/01/2025 22:49:06 SOC:25646,62712,29458,114800,75,66,60,36 02096 12/01/2025 22:50:06 Discharge level 029 AH, SOC: 60%, I: 1A, L:3758, l:3776, H:3773, B:015, PT:032C, BT:024C, PV:105536, M:Bike On 02097 12/01/2025 22:50:06 SOC:25736,63540,29648,114800,75,66,60,28 02098 12/01/2025 22:51:06 Discharge level 030 AH, SOC: 60%, I: 1A, L:3750, l:3776, H:3764, B:014, PT:032C, BT:024C, PV:105285, M:Bike On 02099 12/01/2025 22:51:06 SOC:25693,63404,30067,114800,74,66,60,39 02100 12/01/2025 22:52:06 Discharge level 030 AH, SOC: 59%, I: 1A, L:3727, l:3766, H:3744, B:017, PT:032C, BT:025C, PV:104724, M:Bike On 02101 12/01/2025 22:52:06 SOC:26297,63297,30914,114800,74,65,59,59 02102 12/01/2025 22:53:06 Discharge level 031 AH, SOC: 58%, I: 1A, L:3730, l:3757, H:3746, B:016, PT:032C, BT:025C, PV:104781, M:Bike On 02103 12/01/2025 22:53:06 SOC:26676,63231,31562,114800,73,64,58,42 02104 12/01/2025 22:54:06 Discharge level 032 AH, SOC: 58%, I: 42A, L:3672, l:3719, H:3704, B:032, PT:032C, BT:025C, PV:103508, M:Bike On 02105 12/01/2025 22:54:06 SOC:26917,63454,32020,114800,73,59,58,72 02106 12/01/2025 22:55:06 Discharge level 033 AH, SOC: 55%, I:496A, L:3215, l:3499, H:3378, B:163, PT:032C, BT:025C, PV: 93275, M:Bike On 02107 12/01/2025 22:55:06 SOC:28645,62853,33759,114800,71,7,55,442 02108 12/01/2025 22:55:06 Discharge cutback 75% 02109 12/01/2025 22:55:06 641A 02110 12/01/2025 22:56:06 Discharge level 036 AH, SOC: 49%, I:213A, L:3391, l:3593, H:3493, B:102, PT:033C, BT:025C, PV: 97033, M:Bike On 02111 12/01/2025 22:56:06 SOC:31518,61159,36639,114800,69,34,49,323 02112 12/01/2025 22:56:06 Discharge cutback 58% 02113 12/01/2025 22:56:06 499A 02114 12/01/2025 22:57:06 Discharge level 037 AH, SOC: 47%, I:-28A, L:3670, l:3707, H:3692, B:022, PT:033C, BT:026C, PV:103250, M:Bike On 02115 12/01/2025 22:57:06 SOC:32391,60891,37780,114800,68,58,47,62 02116 12/01/2025 22:57:06 Discharge cutback 81% 02117 12/01/2025 22:57:06 698A 02118 12/01/2025 22:58:06 Discharge level 038 AH, SOC: 48%, I: -2A, L:3675, l:3704, H:3695, B:020, PT:033C, BT:026C, PV:103331, M:Bike On 02119 12/01/2025 22:58:06 SOC:32337,61521,38062,114800,67,57,48,49 02120 12/01/2025 22:58:56 Contactor was Opened Pack V: 103583mV, Switched V: 103581mV, Prechg Pct: 100%, Dischg Cur: 1546mA 02121 12/01/2025 22:58:57 System Turned Off 02122 12/01/2025 22:58:58 DEBUG: CAN Link Is Down 02123 12/01/2025 22:58:58 DEBUG: Entered Idle State 02124 12/01/2025 22:59:04 Current Sensor Zeroed old: 2504mV, new: 2507mV, corrfact: 249 02125 12/01/2025 22:59:05 Discharge level 038 AH, SOC: 49%, I: 0A, L:3688, l:3704, H:3705, B:017, PT:033C, BT:025C, PV:103636, M:Idle 02126 12/01/2025 22:59:05 SOC:32340,62793,38087,114800,67,58,49,28 02127 12/01/2025 22:59:10 System Turned On 02128 12/01/2025 22:59:10 Rev:45,Build:2023-05-20_045619 958 banka 02129 12/01/2025 22:59:10 Pack:2019_monolith,Numbricks:4 02130 12/01/2025 22:59:10 DEBUG: Entered Running State 02131 12/01/2025 22:59:10 DEBUG: CAN NOT Receiving Syncs 02132 12/01/2025 22:59:10 DEBUG: CAN Link Is Up 02133 12/01/2025 22:59:11 DEBUG: Resetting CAN0 due to error passive mode 02134 12/01/2025 22:59:11 Discharge level 038 AH, SOC: 49%, I: 0A, L:3688, l:3705, H:3705, B:017, PT:033C, BT:026C, PV:103643, M:Bike On 02135 12/01/2025 22:59:11 SOC:32334,62793,38087,114800,67,58,49,28 02136 12/01/2025 22:59:14 DEBUG: CAN Receiving Syncs 02137 12/01/2025 22:59:15 Contactor drive turned on Pack V: 103649mV, Switched V: 91214mV, Duty Cycle: 38% 02138 12/01/2025 22:59:15 Contactor was Closed Pack V: 103649mV, Switched V: 91214mV, Prechg Pct: 88%, Dischg Cur: 909mA 02139 12/01/2025 22:59:20 DEBUG: Entered Charging State 02140 12/01/2025 22:59:20 DEBUG: CAN NOT Receiving Syncs 02141 12/01/2025 22:59:21 Discharge level 038 AH, SOC: 49%, I: 1A, L:3690, l:3706, H:3706, B:016, PT:033C, BT:025C, PV:103674, M:Charge 02142 12/01/2025 22:59:21 SOC:32303,62933,38089,114800,67,58,49,26 02143 12/01/2025 22:59:21 DEBUG: CAN Receiving Syncs 02144 12/01/2025 23:09:21 Discharge level 036 AH, SOC: 60%, I:-12A, L:3753, l:3740, H:3758, B:005, PT:032C, BT:035C, PV:105159, M:Charge 02145 12/01/2025 23:09:21 SOC:21940,54567,36172,114800,69,63,60,-20 02146 12/01/2025 23:19:21 Discharge level 034 AH, SOC: 66%, I:-11A, L:3776, l:3762, H:3783, B:007, PT:032C, BT:036C, PV:105833, M:Charge 02147 12/01/2025 23:19:21 SOC:18501,53076,34241,114800,71,65,66,-21 02148 12/01/2025 23:29:21 Discharge level 032 AH, SOC: 69%, I:-11A, L:3799, l:3785, H:3808, B:009, PT:031C, BT:038C, PV:106469, M:Charge 02149 12/01/2025 23:29:21 SOC:17147,53657,32324,114800,72,68,69,-21 02150 12/01/2025 23:39:29 Discharge level 030 AH, SOC: 71%, I:-11A, L:3822, l:3807, H:3833, B:011, PT:031C, BT:038C, PV:107133, M:Charge 02151 12/01/2025 23:39:29 SOC:15946,54408,30392,114800,74,70,71,-21 02152 12/01/2025 23:49:29 Discharge level 028 AH, SOC: 73%, I:-11A, L:3846, l:3831, H:3856, B:010, PT:030C, BT:038C, PV:107803, M:Charge 02153 12/01/2025 23:49:29 SOC:14987,55358,28501,114800,76,72,73,-21 02154 12/01/2025 23:59:29 Discharge level 026 AH, SOC: 76%, I:-11A, L:3871, l:3856, H:3880, B:009, PT:030C, BT:038C, PV:108494, M:Charge 02155 12/01/2025 23:59:29 SOC:13768,56041,26619,114800,77,75,76,-21 02156 12/02/2025 00:09:29 Discharge level 024 AH, SOC: 78%, I:-11A, L:3896, l:3881, H:3901, B:005, PT:029C, BT:039C, PV:109165, M:Charge 02157 12/02/2025 00:09:29 SOC:12587,56739,24759,114800,79,77,78,-21 02158 12/02/2025 00:19:29 Discharge level 022 AH, SOC: 81%, I:-11A, L:3919, l:3904, H:3924, B:005, PT:029C, BT:042C, PV:109806, M:Charge 02159 12/02/2025 00:19:29 SOC:11476,57496,22909,114800,81,80,81,-21 02160 12/02/2025 00:29:29 Discharge level 021 AH, SOC: 82%, I:-10A, L:3940, l:3925, H:3945, B:005, PT:028C, BT:041C, PV:110394, M:Charge 02161 12/02/2025 00:29:29 SOC:10535,58419,21064,114800,82,81,82,-20 02162 12/02/2025 00:39:29 Discharge level 019 AH, SOC: 84%, I:-11A, L:3960, l:3945, H:3964, B:004, PT:028C, BT:039C, PV:110946, M:Charge 02163 12/02/2025 00:39:29 SOC:9607,59333,19240,114800,84,83,84,-20 02164 12/02/2025 00:49:37 Discharge level 017 AH, SOC: 86%, I:-11A, L:3980, l:3965, H:3983, B:003, PT:027C, BT:038C, PV:111498, M:Charge 02165 12/02/2025 00:49:37 SOC:8627,60207,17406,114800,85,85,86,-20 02166 12/02/2025 00:59:37 Discharge level 015 AH, SOC: 88%, I:-11A, L:3999, l:3984, H:4003, B:004, PT:027C, BT:034C, PV:112031, M:Charge 02167 12/02/2025 00:59:37 SOC:7739,61128,15616,114800,87,87,88,-20 02168 12/02/2025 01:09:37 Discharge level 013 AH, SOC: 89%, I:-10A, L:4019, l:4004, H:4022, B:003, PT:027C, BT:031C, PV:112574, M:Charge 02169 12/02/2025 01:09:37 SOC:6835,62031,13828,114800,88,89,89,-20 02170 12/02/2025 01:12:37 Charged To Full 013 AH, SOC: 90%, L:4025, H:4028, B:003, PT:026C, BT:030C, PV:112733 02171 12/02/2025 01:12:37 SOC adjusted for voltage old: 6459860uAH (soc:90%), new: 6219760uAH (soc:90%), low cell: 4025 mV 02172 12/02/2025 01:19:37 Discharge level 010 AH, SOC: 91%, I:-10A, L:4039, l:4024, H:4042, B:003, PT:026C, BT:033C, PV:113115, M:Charge 02173 12/02/2025 01:19:37 SOC:5756,62987,10240,114800,92,90,91,-20 02174 12/02/2025 01:29:37 Discharge level 008 AH, SOC: 93%, I:-10A, L:4057, l:4042, H:4061, B:004, PT:026C, BT:033C, PV:113651, M:Charge 02175 12/02/2025 01:29:37 SOC:4690,63697,8485,114800,93,92,93,-20 02176 12/02/2025 01:39:37 Discharge level 006 AH, SOC: 95%, I:-10A, L:4077, l:4063, H:4081, B:004, PT:025C, BT:035C, PV:114203, M:Charge 02177 12/02/2025 01:39:37 SOC:3557,64322,6745,114800,95,94,95,-19 02178 12/02/2025 01:49:37 Discharge level 005 AH, SOC: 97%, I:-10A, L:4096, l:4082, H:4100, B:004, PT:025C, BT:036C, PV:114747, M:Charge 02179 12/02/2025 01:49:37 SOC:2377,64891,5016,114800,96,96,97,-19 02180 12/02/2025 02:30:26 DEBUG: CAN Link Is Down 02181 12/02/2025 02:30:30 Contactor was Opened Pack V: 116174mV, Switched V: 116066mV, Prechg Pct: 100%, Dischg Cur: 545mA 02182 12/02/2025 02:30:30 DEBUG: CAN Link Is Up 02183 12/02/2025 02:30:32 System Turned Off 02184 12/02/2025 02:30:33 DEBUG: CAN Link Is Down 02185 12/02/2025 02:30:33 DEBUG: Entered Idle State 02186 12/02/2025 02:30:40 Discharge level 000 AH, SOC:100%, I: 0A, L:4147, l:4144, H:4150, B:003, PT:024C, BT:033C, PV:116038, M:Idle 02187 12/02/2025 02:30:40 SOC:0,65961,0,114800,100,100,100,-4 02188 12/02/2025 02:31:00 Voltage Across Contactor: 103163mV (Okay) 02189 12/02/2025 07:57:00 System Turned On 02190 12/02/2025 07:57:00 Rev:45,Build:2023-05-20_045619 958 banka 02191 12/02/2025 07:57:00 Pack:2019_monolith,Numbricks:4 02192 12/02/2025 07:57:00 DEBUG: Entered Charging State 02193 12/02/2025 07:57:00 DEBUG: CAN NOT Receiving Syncs 02194 12/02/2025 07:57:00 DEBUG: Entered Running State 02195 12/02/2025 07:57:00 DEBUG: CAN Link Is Up 02196 12/02/2025 07:57:01 DEBUG: Resetting CAN0 due to error passive mode 02197 12/02/2025 07:57:01 Discharge level 000 AH, SOC:100%, I: 0A, L:4120, l:4117, H:4124, B:004, PT:020C, BT:034C, PV:115455, M:Bike On 02198 12/02/2025 07:57:01 SOC:0,65961,0,114800,100,99,100,-4 02199 12/02/2025 07:57:04 DEBUG: CAN Receiving Syncs 02200 12/02/2025 07:57:04 Contactor drive turned on Pack V: 115433mV, Switched V: 101218mV, Duty Cycle: 34% 02201 12/02/2025 07:57:05 Contactor was Closed Pack V: 115433mV, Switched V: 101218mV, Prechg Pct: 88%, Dischg Cur: 909mA 02202 12/02/2025 07:57:06 DEBUG: Entered Charging State 02203 12/02/2025 07:57:06 DEBUG: CAN NOT Receiving Syncs 02204 12/02/2025 07:57:07 SOC adjusted for voltage old: 5137uAH (soc:100%), new: 0uAH (soc:100%), low cell: 4120 mV 02205 12/02/2025 07:57:07 Discharge level 000 AH, SOC:100%, I: 1A, L:4120, l:4118, H:4124, B:004, PT:020C, BT:033C, PV:115437, M:Charge 02206 12/02/2025 07:57:07 SOC:0,65957,0,114800,100,99,100,-3 02207 12/02/2025 07:57:08 DEBUG: CAN Receiving Syncs 02208 12/02/2025 07:59:31 DEBUG: Entered Running State 02209 12/02/2025 07:59:31 DEBUG: CAN NOT Receiving Syncs 02210 12/02/2025 07:59:32 Discharge level 000 AH, SOC:100%, I: 0A, L:4136, l:4128, H:4139, B:003, PT:020C, BT:034C, PV:115864, M:Bike On 02211 12/02/2025 07:59:32 SOC:0,65962,0,114800,100,100,100,-9 02212 12/02/2025 07:59:33 DEBUG: CAN Receiving Syncs 02213 12/02/2025 08:00:32 Discharge level 000 AH, SOC:100%, I: 0A, L:4129, l:4128, H:4133, B:004, PT:020C, BT:032C, PV:115689, M:Bike On 02214 12/02/2025 08:00:32 SOC:15,65962,16,114800,100,100,100,-2 02215 12/02/2025 08:01:32 Discharge level 000 AH, SOC:100%, I: -2A, L:4119, l:4127, H:4123, B:004, PT:020C, BT:031C, PV:115414, M:Bike On 02216 12/02/2025 08:01:32 SOC:264,65659,259,114800,100,100,100,9 02217 12/02/2025 08:02:32 Discharge level 000 AH, SOC: 99%, I: 9A, L:3979, l:4018, H:4001, B:022, PT:020C, BT:029C, PV:111764, M:Bike On 02218 12/02/2025 08:02:32 SOC:808,64900,812,114800,100,90,99,43 02219 12/02/2025 08:03:32 Discharge level 001 AH, SOC: 98%, I: 12A, L:3976, l:4020, H:3996, B:020, PT:020C, BT:028C, PV:111656, M:Bike On 02220 12/02/2025 08:03:32 SOC:1483,64041,1475,114800,99,90,98,51 02221 12/02/2025 08:04:32 Discharge level 002 AH, SOC: 96%, I: 1A, L:3995, l:4050, H:4010, B:015, PT:020C, BT:028C, PV:112099, M:Bike On 02222 12/02/2025 08:04:32 SOC:2988,62599,2999,114800,98,93,96,64 02223 12/02/2025 08:05:32 Discharge level 003 AH, SOC: 95%, I:102A, L:3840, l:3958, H:3877, B:037, PT:021C, BT:028C, PV:108073, M:Bike On 02224 12/02/2025 08:05:32 SOC:3689,61829,3737,114800,97,84,95,136 02225 12/02/2025 08:06:32 Discharge level 004 AH, SOC: 94%, I: 1A, L:4034, l:4062, H:4045, B:011, PT:021C, BT:028C, PV:113147, M:Bike On 02226 12/02/2025 08:06:32 SOC:3968,61445,4060,114800,97,94,94,32 02227 12/02/2025 08:07:32 Discharge level 004 AH, SOC: 93%, I: 0A, L:4038, l:4070, H:4047, B:009, PT:021C, BT:027C, PV:113231, M:Bike On 02228 12/02/2025 08:07:32 SOC:4452,60966,4571,114800,97,95,93,39 02229 12/02/2025 08:08:32 Discharge level 004 AH, SOC: 93%, I: 28A, L:3996, l:4031, H:4012, B:016, PT:021C, BT:028C, PV:112162, M:Bike On 02230 12/02/2025 08:08:32 SOC:4522,60874,4680,114800,96,91,93,43 02231 12/02/2025 08:09:32 Discharge level 005 AH, SOC: 92%, I: 60A, L:3917, l:3981, H:3944, B:027, PT:021C, BT:026C, PV:110113, M:Bike On 02232 12/02/2025 08:09:32 SOC:5021,60453,5203,114800,96,86,92,79 02233 12/02/2025 08:10:32 Discharge level 006 AH, SOC: 91%, I: 50A, L:3934, l:4002, H:3957, B:023, PT:022C, BT:026C, PV:110543, M:Bike On 02234 12/02/2025 08:10:32 SOC:5832,59839,6019,114800,95,88,91,83 02235 12/02/2025 08:11:32 Discharge level 007 AH, SOC: 89%, I: 2A, L:3931, l:4012, H:3952, B:021, PT:022C, BT:027C, PV:110437, M:Bike On 02236 12/02/2025 08:11:32 SOC:6892,58933,7101,114800,94,89,89,99 02237 12/02/2025 08:12:32 Discharge level 007 AH, SOC: 88%, I: 40A, L:3926, l:3983, H:3949, B:023, PT:022C, BT:025C, PV:110338, M:Bike On 02238 12/02/2025 08:12:32 SOC:7325,58679,7593,114800,94,86,88,69 02239 12/02/2025 08:13:32 Discharge level 008 AH, SOC: 86%, I: 82A, L:3818, l:3919, H:3856, B:038, PT:023C, BT:026C, PV:107550, M:Bike On 02240 12/02/2025 08:13:32 SOC:8384,57957,8726,114800,93,81,86,126 02241 12/02/2025 08:14:32 Discharge level 010 AH, SOC: 83%, I: 80A, L:3778, l:3912, H:3818, B:040, PT:023C, BT:027C, PV:106470, M:Bike On 02242 12/02/2025 08:14:32 SOC:9986,57164,10336,114800,91,80,83,165 02243 12/02/2025 08:15:32 Discharge level 011 AH, SOC: 81%, I: 92A, L:3766, l:3891, H:3808, B:042, PT:024C, BT:026C, PV:106180, M:Bike On 02244 12/02/2025 08:15:32 SOC:11113,56959,11485,114800,90,78,81,156 02245 12/02/2025 08:16:32 Discharge level 013 AH, SOC: 78%, I:117A, L:3711, l:3863, H:3760, B:049, PT:024C, BT:027C, PV:104787, M:Bike On 02246 12/02/2025 08:16:32 SOC:12875,56628,13261,114800,89,75,78,189 02247 12/02/2025 08:17:32 Discharge level 016 AH, SOC: 72%, I:111A, L:3651, l:3851, H:3707, B:056, PT:026C, BT:026C, PV:103252, M:Bike On 02248 12/02/2025 08:17:32 SOC:15727,55932,16119,114800,86,74,72,255 02249 12/02/2025 08:18:32 Discharge level 016 AH, SOC: 71%, I:237A, L:3587, l:3774, H:3660, B:073, PT:026C, BT:026C, PV:101767, M:Bike On 02250 12/02/2025 08:18:32 SOC:16253,56025,16988,114800,86,65,71,237 02251 12/02/2025 08:19:32 Discharge level 017 AH, SOC: 71%, I: 66A, L:3799, l:3871, H:3830, B:031, PT:027C, BT:026C, PV:106963, M:Bike On 02252 12/02/2025 08:19:32 SOC:16403,56285,17472,114800,85,76,71,95 02253 12/02/2025 08:20:32 Discharge level 017 AH, SOC: 72%, I:-13A, L:3890, l:3910, H:3904, B:014, PT:027C, BT:027C, PV:109210, M:Bike On 02254 12/02/2025 08:20:32 SOC:16293,56907,17582,114800,85,80,72,26 02255 12/02/2025 08:21:32 Discharge level 017 AH, SOC: 72%, I: 1A, L:3867, l:3898, H:3884, B:017, PT:027C, BT:027C, PV:108626, M:Bike On 02256 12/02/2025 08:21:32 SOC:16467,57479,17934,114800,85,79,72,41 02257 12/02/2025 08:22:32 Discharge level 018 AH, SOC: 71%, I: 87A, L:3751, l:3828, H:3790, B:039, PT:027C, BT:027C, PV:105743, M:Bike On 02258 12/02/2025 08:22:32 SOC:16920,57766,18629,114800,84,72,71,101 02259 12/02/2025 08:23:32 Discharge level 019 AH, SOC: 70%, I: 16A, L:3840, l:3878, H:3858, B:018, PT:027C, BT:026C, PV:107901, M:Bike On 02260 12/02/2025 08:23:32 SOC:17434,58055,19361,114800,84,77,70,50 02261 12/02/2025 08:24:32 Discharge level 019 AH, SOC: 71%, I: 18A, L:3836, l:3870, H:3856, B:020, PT:027C, BT:026C, PV:107808, M:Bike On 02262 12/02/2025 08:24:32 SOC:17664,58890,19643,114800,83,76,71,46 02263 12/02/2025 08:25:32 Discharge level 019 AH, SOC: 71%, I: 1A, L:3866, l:3878, H:3881, B:015, PT:027C, BT:026C, PV:108554, M:Bike On 02264 12/02/2025 08:25:32 SOC:17600,59407,19809,114800,83,77,71,17 02265 12/02/2025 08:26:32 Discharge level 019 AH, SOC: 71%, I: 58A, L:3802, l:3845, H:3829, B:027, PT:027C, BT:027C, PV:106971, M:Bike On 02266 12/02/2025 08:26:32 SOC:17470,59822,19934,114800,83,73,71,58 02267 12/02/2025 08:27:32 Discharge level 020 AH, SOC: 72%, I: 0A, L:3870, l:3879, H:3884, B:014, PT:027C, BT:027C, PV:108634, M:Bike On 02268 12/02/2025 08:27:32 SOC:17458,60385,20077,114800,83,77,72,13 02269 12/02/2025 08:28:32 Discharge level 020 AH, SOC: 72%, I: -2A, L:3881, l:3884, H:3893, B:012, PT:027C, BT:026C, PV:108896, M:Bike On 02270 12/02/2025 08:28:32 SOC:17201,60680,20106,114800,83,77,72,4 02271 12/02/2025 08:29:32 Discharge level 020 AH, SOC: 72%, I: 1A, L:3849, l:3878, H:3866, B:017, PT:027C, BT:027C, PV:108098, M:Bike On 02272 12/02/2025 08:29:32 SOC:17281,60805,20420,114800,83,77,72,39 02273 12/02/2025 08:30:32 Discharge level 020 AH, SOC: 72%, I: 34A, L:3822, l:3854, H:3843, B:021, PT:027C, BT:026C, PV:107443, M:Bike On 02274 12/02/2025 08:30:32 SOC:17368,61126,20676,114800,82,74,72,42 02275 12/02/2025 08:31:32 Discharge level 020 AH, SOC: 72%, I: 0A, L:3869, l:3876, H:3882, B:013, PT:027C, BT:027C, PV:108577, M:Bike On 02276 12/02/2025 08:31:33 SOC:17252,61428,20757,114800,82,77,72,9 02277 12/02/2025 08:31:42 Contactor was Opened Pack V: 108606mV, Switched V: 108544mV, Prechg Pct: 100%, Dischg Cur: 636mA 02278 12/02/2025 08:31:43 System Turned Off 02279 12/02/2025 08:31:44 DEBUG: CAN Link Is Down 02280 12/02/2025 08:31:44 DEBUG: Entered Idle State 02281 12/02/2025 08:31:49 Current Sensor Zeroed old: 2507mV, new: 2504mV, corrfact: 252 02282 12/02/2025 08:31:51 Discharge level 020 AH, SOC: 72%, I: 0A, L:3871, l:3877, H:3884, B:013, PT:027C, BT:027C, PV:108645, M:Idle 02283 12/02/2025 08:31:51 SOC:17216,61485,20758,114800,82,77,72,8 02284 12/02/2025 08:32:12 Voltage Across Contactor: 95659mV (Okay) 02285 12/02/2025 09:21:10 System Turned On 02286 12/02/2025 09:21:10 Rev:45,Build:2023-05-20_045619 958 banka 02287 12/02/2025 09:21:10 Pack:2019_monolith,Numbricks:4 02288 12/02/2025 09:21:10 DEBUG: Entered Running State 02289 12/02/2025 09:21:10 DEBUG: CAN NOT Receiving Syncs 02290 12/02/2025 09:21:10 DEBUG: CAN Link Is Up 02291 12/02/2025 09:21:11 DEBUG: Resetting CAN0 due to error passive mode 02292 12/02/2025 09:21:11 Discharge level 020 AH, SOC: 73%, I: 0A, L:3894, l:3900, H:3903, B:009, PT:025C, BT:038C, PV:109221, M:Bike On 02293 12/02/2025 09:21:11 SOC:17212,61485,20758,114800,82,79,73,8 02294 12/02/2025 09:21:14 DEBUG: CAN Receiving Syncs 02295 12/02/2025 09:21:19 Contactor drive turned on Pack V: 109197mV, Switched V: 96177mV, Duty Cycle: 36% 02296 12/02/2025 09:21:19 Contactor was Closed Pack V: 109197mV, Switched V: 96177mV, Prechg Pct: 88%, Dischg Cur: 1091mA 02297 12/02/2025 09:22:11 Discharge level 020 AH, SOC: 73%, I: 1A, L:3894, l:3898, H:3903, B:009, PT:025C, BT:035C, PV:109196, M:Bike On 02298 12/02/2025 09:22:11 SOC:17140,62379,20777,114800,82,79,73,5 02299 12/02/2025 09:23:11 Discharge level 020 AH, SOC: 73%, I: 19A, L:3866, l:3881, H:3878, B:012, PT:025C, BT:035C, PV:108494, M:Bike On 02300 12/02/2025 09:23:11 SOC:17154,63296,20834,114800,82,77,73,19 02301 12/02/2025 09:24:11 Discharge level 021 AH, SOC: 73%, I: 56A, L:3813, l:3851, H:3837, B:024, PT:025C, BT:034C, PV:107178, M:Bike On 02302 12/02/2025 09:24:11 SOC:17287,63954,21029,114800,82,74,73,48 02303 12/02/2025 09:25:11 Discharge level 021 AH, SOC: 74%, I: 1A, L:3878, l:3886, H:3888, B:010, PT:025C, BT:032C, PV:108781, M:Bike On 02304 12/02/2025 09:25:11 SOC:17352,64394,21229,114800,82,78,74,10 02305 12/02/2025 09:26:11 Discharge level 021 AH, SOC: 74%, I: 6A, L:3871, l:3881, H:3881, B:010, PT:025C, BT:031C, PV:108589, M:Bike On 02306 12/02/2025 09:26:11 SOC:17438,65025,21354,114800,82,77,74,13 02307 12/02/2025 09:27:11 Discharge level 021 AH, SOC: 73%, I: 1A, L:3862, l:3880, H:3872, B:010, PT:025C, BT:030C, PV:108327, M:Bike On 02308 12/02/2025 09:27:11 SOC:17709,65339,21704,114800,82,77,73,23 02309 12/02/2025 09:28:11 Discharge level 023 AH, SOC: 71%, I:-31A, L:3856, l:3879, H:3861, B:005, PT:026C, BT:030C, PV:108047, M:Bike On 02310 12/02/2025 09:28:11 SOC:19066,64804,23161,114800,80,77,71,30 02311 12/02/2025 09:29:11 Discharge level 024 AH, SOC: 69%, I:156A, L:3581, l:3750, H:3632, B:051, PT:026C, BT:030C, PV:101142, M:Bike On 02312 12/02/2025 09:29:11 SOC:20364,64366,24529,114800,79,63,69,215 02313 12/02/2025 09:30:11 Discharge level 025 AH, SOC: 68%, I: 41A, L:3742, l:3803, H:3763, B:021, PT:026C, BT:029C, PV:105167, M:Bike On 02314 12/02/2025 09:30:11 SOC:21016,64428,25292,114800,78,69,68,77 02315 12/02/2025 09:31:11 Discharge level 026 AH, SOC: 67%, I: 32A, L:3741, l:3801, H:3760, B:019, PT:026C, BT:029C, PV:105099, M:Bike On 02316 12/02/2025 09:31:11 SOC:21764,64650,26064,114800,78,69,67,76 02317 12/02/2025 09:32:11 Discharge level 026 AH, SOC: 66%, I: 0A, L:3778, l:3814, H:3788, B:010, PT:026C, BT:029C, PV:105982, M:Bike On 02318 12/02/2025 09:32:11 SOC:22335,64913,26694,114800,77,71,66,48 02319 12/02/2025 09:33:11 Discharge level 027 AH, SOC: 65%, I: 20A, L:3750, l:3799, H:3764, B:014, PT:027C, BT:028C, PV:105284, M:Bike On 02320 12/02/2025 09:33:11 SOC:23209,64841,27642,114800,76,69,65,65 02321 12/02/2025 09:34:05 Contactor was Opened Pack V: 106021mV, Switched V: 105984mV, Prechg Pct: 100%, Dischg Cur: 1546mA 02322 12/02/2025 09:34:06 System Turned Off 02323 12/02/2025 09:34:06 DEBUG: CAN Link Is Down 02324 12/02/2025 09:34:06 DEBUG: Entered Idle State 02325 12/02/2025 09:34:12 Current Sensor Zeroed old: 2504mV, new: 2507mV, corrfact: 249 02326 12/02/2025 09:34:14 Discharge level 027 AH, SOC: 65%, I: 0A, L:3784, l:3803, H:3792, B:008, PT:027C, BT:028C, PV:106111, M:Idle 02327 12/02/2025 09:34:14 SOC:23245,65370,27757,114800,76,69,65,25 02328 12/02/2025 09:34:35 Voltage Across Contactor: 93220mV (Okay) 02329 12/02/2025 09:36:16 System Turned On 02330 12/02/2025 09:36:16 Rev:45,Build:2023-05-20_045619 958 banka 02331 12/02/2025 09:36:16 Pack:2019_monolith,Numbricks:4 02332 12/02/2025 09:36:16 DEBUG: Entered Running State 02333 12/02/2025 09:36:16 DEBUG: CAN NOT Receiving Syncs 02334 12/02/2025 09:36:17 DEBUG: CAN Link Is Up 02335 12/02/2025 09:36:17 DEBUG: Resetting CAN0 due to error passive mode 02336 12/02/2025 09:36:17 Discharge level 027 AH, SOC: 65%, I: 0A, L:3798, l:3817, H:3805, B:007, PT:027C, BT:028C, PV:106453, M:Bike On 02337 12/02/2025 09:36:17 SOC:23240,65370,27757,114800,76,71,65,25 02338 12/02/2025 09:36:21 DEBUG: CAN Receiving Syncs 02339 12/02/2025 09:36:25 Contactor drive turned on Pack V: 106455mV, Switched V: 94168mV, Duty Cycle: 37% 02340 12/02/2025 09:36:25 Contactor was Closed Pack V: 106455mV, Switched V: 94168mV, Prechg Pct: 88%, Dischg Cur: 545mA 02341 12/02/2025 09:37:17 Discharge level 027 AH, SOC: 66%, I: 0A, L:3800, l:3811, H:3806, B:006, PT:027C, BT:028C, PV:106505, M:Bike On 02342 12/02/2025 09:37:17 SOC:22878,65377,27758,114800,76,70,66,15 02343 12/02/2025 09:38:17 Discharge level 027 AH, SOC: 66%, I: 0A, L:3788, l:3808, H:3795, B:007, PT:027C, BT:028C, PV:106184, M:Bike On 02344 12/02/2025 09:38:17 SOC:22924,65685,27969,114800,76,70,66,27 02345 12/02/2025 09:39:17 Discharge level 028 AH, SOC: 66%, I: 1A, L:3787, l:3801, H:3793, B:006, PT:027C, BT:028C, PV:106152, M:Bike On 02346 12/02/2025 09:39:17 SOC:23033,65932,28235,114800,76,69,66,19 02347 12/02/2025 09:40:17 Discharge level 028 AH, SOC: 66%, I: 1A, L:3786, l:3798, H:3793, B:007, PT:026C, BT:028C, PV:106133, M:Bike On 02348 12/02/2025 09:40:18 SOC:23119,66341,28404,114800,76,69,66,15 02349 12/02/2025 09:41:17 Discharge level 028 AH, SOC: 66%, I: 1A, L:3785, l:3798, H:3792, B:007, PT:026C, BT:028C, PV:106081, M:Bike On 02350 12/02/2025 09:41:18 SOC:23246,66789,28573,114800,76,69,66,18 02351 12/02/2025 09:42:18 Discharge level 028 AH, SOC: 66%, I: 35A, L:3736, l:3774, H:3749, B:013, PT:026C, BT:028C, PV:104850, M:Bike On 02352 12/02/2025 09:42:18 SOC:23403,66964,28842,114800,75,66,66,49 02353 12/02/2025 09:43:18 Discharge level 029 AH, SOC: 66%, I: 1A, L:3781, l:3791, H:3787, B:006, PT:026C, BT:028C, PV:105980, M:Bike On 02354 12/02/2025 09:43:18 SOC:23479,67214,29008,114800,75,68,66,13 02355 12/02/2025 09:44:18 Discharge level 029 AH, SOC: 65%, I: 68A, L:3672, l:3739, H:3697, B:025, PT:026C, BT:028C, PV:103260, M:Bike On 02356 12/02/2025 09:44:18 SOC:24037,67144,29629,114800,75,62,65,86 02357 12/02/2025 09:45:18 Discharge level 030 AH, SOC: 64%, I: 1A, L:3752, l:3780, H:3759, B:007, PT:026C, BT:027C, PV:105182, M:Bike On 02358 12/02/2025 09:45:18 SOC:24471,67068,30166,114800,74,67,64,37 02359 12/02/2025 09:46:18 Discharge level 030 AH, SOC: 64%, I: 1A, L:3756, l:3775, H:3763, B:007, PT:026C, BT:026C, PV:105291, M:Bike On 02360 12/02/2025 09:46:18 SOC:24654,67039,30495,114800,74,66,64,25 02361 12/02/2025 09:47:18 Discharge level 030 AH, SOC: 64%, I: 0A, L:3766, l:3775, H:3772, B:006, PT:026C, BT:027C, PV:105558, M:Bike On 02362 12/02/2025 09:47:18 SOC:24631,67406,30517,114800,74,66,64,12 02363 12/02/2025 09:47:39 Contactor was Opened Pack V: 105600mV, Switched V: 105590mV, Prechg Pct: 100%, Dischg Cur: 1091mA 02364 12/02/2025 09:47:39 System Turned Off 02365 12/02/2025 09:47:40 DEBUG: CAN Link Is Down 02366 12/02/2025 09:47:40 DEBUG: Entered Idle State 02367 12/02/2025 09:47:46 Current Sensor Zeroed old: 2507mV, new: 2504mV, corrfact: 252 02368 12/02/2025 09:47:48 Discharge level 030 AH, SOC: 64%, I: 0A, L:3769, l:3776, H:3776, B:007, PT:026C, BT:027C, PV:105648, M:Idle 02369 12/02/2025 09:47:48 SOC:24620,67529,30524,114800,74,66,64,9 02370 12/02/2025 09:48:09 Voltage Across Contactor: 92543mV (Okay) 02371 12/02/2025 09:48:37 System Turned On 02372 12/02/2025 09:48:37 Rev:45,Build:2023-05-20_045619 958 banka 02373 12/02/2025 09:48:37 Pack:2019_monolith,Numbricks:4 02374 12/02/2025 09:48:37 DEBUG: Entered Running State 02375 12/02/2025 09:48:37 DEBUG: CAN NOT Receiving Syncs 02376 12/02/2025 09:48:38 DEBUG: CAN Link Is Up 02377 12/02/2025 09:48:38 DEBUG: Resetting CAN0 due to error passive mode 02378 12/02/2025 09:48:39 Discharge level 030 AH, SOC: 64%, I: 0A, L:3772, l:3779, H:3778, B:006, PT:026C, BT:027C, PV:105721, M:Bike On 02379 12/02/2025 09:48:39 SOC:24617,67529,30524,114800,74,67,64,9 02380 12/02/2025 09:48:42 DEBUG: CAN Receiving Syncs 02381 12/02/2025 09:48:47 DEBUG: Entered Charging State 02382 12/02/2025 09:48:47 Contactor drive turned on Pack V: 105723mV, Switched V: 91490mV, Duty Cycle: 38% 02383 12/02/2025 09:48:47 Contactor was Closed Pack V: 105723mV, Switched V: 91490mV, Prechg Pct: 87%, Dischg Cur: 636mA 02384 12/02/2025 09:48:47 DEBUG: CAN NOT Receiving Syncs 02385 12/02/2025 09:48:48 DEBUG: CAN Link Is Down 02386 12/02/2025 09:48:48 Discharge level 030 AH, SOC: 64%, I: 1A, L:3772, l:3779, H:3779, B:007, PT:026C, BT:027C, PV:105726, M:Charge 02387 12/02/2025 09:48:48 SOC:24587,67532,30524,114800,74,67,64,9 02388 12/02/2025 09:48:48 Contactor was Opened Pack V: 105725mV, Switched V: 105708mV, Prechg Pct: 100%, Dischg Cur: 909mA 02389 12/02/2025 09:48:48 DEBUG: CAN Link Is Up 02390 12/02/2025 09:48:48 DEBUG: CAN Receiving Syncs 02391 12/02/2025 09:48:50 DEBUG: Entered Running State 02392 12/02/2025 09:48:50 DEBUG: CAN NOT Receiving Syncs 02393 12/02/2025 09:48:51 Discharge level 030 AH, SOC: 64%, I: 0A, L:3772, l:3778, H:3779, B:007, PT:026C, BT:027C, PV:105727, M:Bike On 02394 12/02/2025 09:48:51 SOC:24583,67532,30524,114800,74,67,64,8 02395 12/02/2025 09:48:52 DEBUG: CAN Receiving Syncs 02396 12/02/2025 09:48:52 DEBUG: Entered Charging State 02397 12/02/2025 09:48:52 DEBUG: CAN NOT Receiving Syncs 02398 12/02/2025 09:48:53 Contactor drive turned on Pack V: 105728mV, Switched V: 92356mV, Duty Cycle: 38% 02399 12/02/2025 09:48:53 Contactor was Closed Pack V: 105728mV, Switched V: 92356mV, Prechg Pct: 87%, Dischg Cur: 636mA 02400 12/02/2025 09:48:54 Discharge level 030 AH, SOC: 64%, I: 0A, L:3772, l:3778, H:3778, B:006, PT:026C, BT:026C, PV:105732, M:Charge 02401 12/02/2025 09:48:54 SOC:24579,67532,30524,114800,74,67,64,8 02402 12/02/2025 09:48:54 DEBUG: CAN Link Is Down 02403 12/02/2025 09:48:54 DEBUG: CAN Link Is Up 02404 12/02/2025 09:48:54 DEBUG: Entered Running State 02405 12/02/2025 09:48:54 Contactor was Opened Pack V: 105737mV, Switched V: 105708mV, Prechg Pct: 100%, Dischg Cur: 818mA 02406 12/02/2025 09:48:55 Discharge level 030 AH, SOC: 64%, I: 0A, L:3772, l:3778, H:3779, B:007, PT:026C, BT:027C, PV:105736, M:Bike On 02407 12/02/2025 09:48:55 SOC:24575,67532,30524,114800,74,67,64,8 02408 12/02/2025 09:48:55 DEBUG: CAN Receiving Syncs 02409 12/02/2025 09:48:58 Contactor drive turned on Pack V: 105736mV, Switched V: 93971mV, Duty Cycle: 38% 02410 12/02/2025 09:48:58 Contactor was Closed Pack V: 105736mV, Switched V: 93971mV, Prechg Pct: 89%, Dischg Cur: 545mA 02411 12/02/2025 09:49:03 DEBUG: Entered Charging State 02412 12/02/2025 09:49:03 DEBUG: CAN NOT Receiving Syncs 02413 12/02/2025 09:49:04 Discharge level 030 AH, SOC: 64%, I: 0A, L:3772, l:3778, H:3779, B:007, PT:026C, BT:027C, PV:105740, M:Charge 02414 12/02/2025 09:49:04 SOC:24548,67535,30524,114800,74,67,64,8 02415 12/02/2025 09:49:04 DEBUG: CAN Link Is Down 02416 12/02/2025 09:49:04 Contactor was Opened Pack V: 105742mV, Switched V: 105747mV, Prechg Pct: 100%, Dischg Cur: 909mA 02417 12/02/2025 09:49:04 DEBUG: CAN Link Is Up 02418 12/02/2025 09:49:04 DEBUG: CAN Receiving Syncs 02419 12/02/2025 09:49:06 DEBUG: Entered Running State 02420 12/02/2025 09:49:06 DEBUG: CAN NOT Receiving Syncs 02421 12/02/2025 09:49:07 Discharge level 030 AH, SOC: 64%, I: 0A, L:3773, l:3779, H:3779, B:006, PT:026C, BT:027C, PV:105742, M:Bike On 02422 12/02/2025 09:49:07 SOC:24544,67535,30524,114800,74,67,64,7 02423 12/02/2025 09:49:07 Discharge cutback 89% 02424 12/02/2025 09:49:07 766A 02425 12/02/2025 09:49:07 System Turned Off 02426 12/02/2025 09:49:08 DEBUG: CAN Receiving Syncs 02427 12/02/2025 09:49:08 DEBUG: CAN Link Is Down 02428 12/02/2025 09:49:08 DEBUG: Entered Idle State 02429 12/02/2025 09:49:10 System Turned On 02430 12/02/2025 09:49:10 Rev:45,Build:2023-05-20_045619 958 banka 02431 12/02/2025 09:49:10 Pack:2019_monolith,Numbricks:4 02432 12/02/2025 09:49:10 DEBUG: Entered Running State 02433 12/02/2025 09:49:10 DEBUG: CAN NOT Receiving Syncs 02434 12/02/2025 09:49:10 DEBUG: CAN Link Is Up 02435 12/02/2025 09:49:11 DEBUG: Resetting CAN0 due to error passive mode 02436 12/02/2025 09:49:14 DEBUG: CAN Receiving Syncs 02437 12/02/2025 09:49:14 Contactor drive turned on Pack V: 105747mV, Switched V: 93774mV, Duty Cycle: 38% 02438 12/02/2025 09:49:14 Contactor was Closed Pack V: 105747mV, Switched V: 93774mV, Prechg Pct: 89%, Dischg Cur: 545mA 02439 12/02/2025 09:49:24 DEBUG: Entered Charging State 02440 12/02/2025 09:49:24 DEBUG: CAN NOT Receiving Syncs 02441 12/02/2025 09:49:25 Discharge level 030 AH, SOC: 64%, I: 0A, L:3773, l:3778, H:3779, B:006, PT:026C, BT:027C, PV:105759, M:Charge 02442 12/02/2025 09:49:25 SOC:24497,67564,30525,114800,74,67,64,7 02443 12/02/2025 09:49:26 DEBUG: CAN Receiving Syncs 02444 12/02/2025 09:59:25 Discharge level 028 AH, SOC: 70%, I:-11A, L:3831, l:3815, H:3842, B:011, PT:026C, BT:035C, PV:107397, M:Charge 02445 12/02/2025 09:59:25 SOC:19341,64332,28638,114800,76,71,70,-20 02446 12/02/2025 10:09:25 Discharge level 026 AH, SOC: 74%, I:-11A, L:3862, l:3846, H:3870, B:008, PT:026C, BT:036C, PV:108231, M:Charge 02447 12/02/2025 10:09:25 SOC:16813,63710,26750,114800,77,74,74,-21 02448 12/02/2025 10:19:25 Discharge level 024 AH, SOC: 77%, I:-11A, L:3890, l:3874, H:3895, B:005, PT:026C, BT:038C, PV:109002, M:Charge 02449 12/02/2025 10:19:25 SOC:14852,63637,24879,114800,79,77,77,-21 02450 12/02/2025 10:29:33 Discharge level 022 AH, SOC: 80%, I:-10A, L:3915, l:3899, H:3919, B:004, PT:026C, BT:040C, PV:109701, M:Charge 02451 12/02/2025 10:29:33 SOC:13228,63915,22994,114800,80,79,80,-21 02452 12/02/2025 10:39:33 Discharge level 021 AH, SOC: 82%, I:-10A, L:3936, l:3921, H:3941, B:005, PT:025C, BT:041C, PV:110315, M:Charge 02453 12/02/2025 10:39:33 SOC:11980,64541,21136,114800,82,81,82,-20 02454 12/02/2025 10:49:33 Discharge level 019 AH, SOC: 84%, I:-11A, L:3957, l:3942, H:3962, B:005, PT:025C, BT:042C, PV:110884, M:Charge 02455 12/02/2025 10:49:33 SOC:10854,65258,19311,114800,84,83,84,-20 02456 12/02/2025 10:59:33 Discharge level 017 AH, SOC: 86%, I:-10A, L:3977, l:3962, H:3980, B:003, PT:025C, BT:041C, PV:111416, M:Charge 02457 12/02/2025 10:59:33 SOC:9759,65967,17526,114800,85,85,86,-20 02458 12/02/2025 11:09:33 Discharge level 015 AH, SOC: 87%, I:-10A, L:3994, l:3980, H:3998, B:004, PT:025C, BT:037C, PV:111907, M:Charge 02459 12/02/2025 11:09:33 SOC:8835,66796,15791,114800,87,86,87,-19 02460 12/02/2025 11:19:33 Discharge level 014 AH, SOC: 89%, I:-10A, L:4014, l:4000, H:4017, B:003, PT:025C, BT:037C, PV:112446, M:Charge 02461 12/02/2025 11:19:33 SOC:7751,67450,14072,114800,88,88,89,-19 02462 12/02/2025 11:25:04 Charged To Full 013 AH, SOC: 90%, L:4025, H:4027, B:002, PT:025C, BT:035C, PV:112739 02463 12/02/2025 11:25:04 SOC adjusted for voltage old: 7163620uAH (soc:90%), new: 6781082uAH (soc:90%), low cell: 4025 mV 02464 12/02/2025 11:29:33 Discharge level 010 AH, SOC: 91%, I:-10A, L:4034, l:4020, H:4036, B:002, PT:025C, BT:034C, PV:112981, M:Charge 02465 12/02/2025 11:29:33 SOC:6527,68334,10710,114800,91,90,91,-19 02466 12/02/2025 11:39:33 Discharge level 008 AH, SOC: 93%, I:-10A, L:4053, l:4039, H:4055, B:002, PT:025C, BT:031C, PV:113512, M:Charge 02467 12/02/2025 11:39:33 SOC:5454,69004,8986,114800,93,92,93,-19 02468 12/02/2025 11:49:33 Discharge level 007 AH, SOC: 94%, I:-10A, L:4073, l:4059, H:4075, B:002, PT:025C, BT:031C, PV:114064, M:Charge 02469 12/02/2025 11:49:33 SOC:4232,69509,7277,114800,94,94,94,-19 02470 12/02/2025 11:59:41 Discharge level 005 AH, SOC: 96%, I:-10A, L:4093, l:4078, H:4095, B:002, PT:025C, BT:030C, PV:114630, M:Charge 02471 12/02/2025 11:59:41 SOC:2983,70028,5527,114800,96,96,96,-20 02472 12/02/2025 12:43:33 DEBUG: CAN Link Is Down 02473 12/02/2025 12:43:37 Contactor was Opened Pack V: 115917mV, Switched V: 116066mV, Prechg Pct: 100%, Dischg Cur: 545mA 02474 12/02/2025 12:43:37 DEBUG: CAN Link Is Up 02475 12/02/2025 12:43:40 System Turned Off 02476 12/02/2025 12:43:40 DEBUG: CAN Link Is Down 02477 12/02/2025 12:43:41 DEBUG: Entered Idle State 02478 12/02/2025 12:43:47 Discharge level 000 AH, SOC:100%, I: 0A, L:4147, l:4145, H:4150, B:003, PT:024C, BT:035C, PV:116043, M:Idle 02479 12/02/2025 12:43:47 SOC:0,70888,0,114800,100,100,100,-3 02480 12/02/2025 12:44:07 Voltage Across Contactor: 103137mV (Okay) 02481 12/03/2025 06:07:52 System Turned On 02482 12/03/2025 06:07:52 Rev:45,Build:2023-05-20_045619 958 banka 02483 12/03/2025 06:07:52 Pack:2019_monolith,Numbricks:4 02484 12/03/2025 06:07:52 DEBUG: Entered Charging State 02485 12/03/2025 06:07:52 DEBUG: CAN NOT Receiving Syncs 02486 12/03/2025 06:07:52 DEBUG: Entered Running State 02487 12/03/2025 06:07:52 DEBUG: CAN Link Is Up 02488 12/03/2025 06:07:53 DEBUG: Resetting CAN0 due to error passive mode 02489 12/03/2025 06:07:53 Discharge level 000 AH, SOC:100%, I: 0A, L:4118, l:4114, H:4120, B:002, PT:016C, BT:023C, PV:115344, M:Bike On 02490 12/03/2025 06:07:53 SOC:1,70888,0,114800,100,99,100,-3 02491 12/03/2025 06:07:56 DEBUG: CAN Receiving Syncs 02492 12/03/2025 06:08:01 Contactor drive turned on Pack V: 115319mV, Switched V: 102084mV, Duty Cycle: 34% 02493 12/03/2025 06:08:01 Contactor was Closed Pack V: 115319mV, Switched V: 102084mV, Prechg Pct: 89%, Dischg Cur: 545mA 02494 12/03/2025 06:08:53 Discharge level 000 AH, SOC:100%, I: 0A, L:4116, l:4116, H:4118, B:002, PT:016C, BT:024C, PV:115299, M:Bike On 02495 12/03/2025 06:08:53 SOC:66,70874,3,114800,100,99,100,0 02496 12/03/2025 06:09:53 Discharge level 000 AH, SOC:100%, I: 0A, L:4101, l:4115, H:4104, B:003, PT:016C, BT:023C, PV:114877, M:Bike On 02497 12/03/2025 06:09:53 SOC:300,70381,210,114800,100,99,100,13 02498 12/03/2025 06:10:53 Discharge level 000 AH, SOC:100%, I: 1A, L:4025, l:4043, H:4042, B:017, PT:016C, BT:023C, PV:112968, M:Bike On 02499 12/03/2025 06:10:53 SOC:543,69811,445,114800,100,92,100,16 02500 12/03/2025 06:11:53 Discharge level 000 AH, SOC:100%, I: 1A, L:4096, l:4106, H:4100, B:004, PT:016C, BT:023C, PV:114763, M:Bike On 02501 12/03/2025 06:11:53 SOC:676,69446,565,114800,100,98,100,9 02502 12/03/2025 06:12:53 Discharge level 000 AH, SOC:100%, I: 1A, L:4094, l:4100, H:4098, B:004, PT:016C, BT:023C, PV:114701, M:Bike On 02503 12/03/2025 06:12:53 SOC:665,69235,571,114800,100,97,100,5 02504 12/03/2025 06:13:53 Discharge level 000 AH, SOC: 99%, I: 1A, L:4088, l:4100, H:4093, B:005, PT:016C, BT:023C, PV:114527, M:Bike On 02505 12/03/2025 06:13:53 SOC:875,68774,766,114800,100,97,99,10 02506 12/03/2025 06:14:53 Discharge level 001 AH, SOC: 98%, I: 1A, L:4063, l:4097, H:4071, B:008, PT:016C, BT:023C, PV:113903, M:Bike On 02507 12/03/2025 06:14:53 SOC:1428,67723,1305,114800,99,97,98,31 02508 12/03/2025 06:15:53 Discharge level 001 AH, SOC: 97%, I: 1A, L:4046, l:4080, H:4055, B:009, PT:016C, BT:023C, PV:113424, M:Bike On 02509 12/03/2025 06:15:53 SOC:2100,66634,1999,114800,99,96,97,31 02510 12/03/2025 06:16:53 Discharge level 002 AH, SOC: 96%, I: 15A, L:4017, l:4071, H:4028, B:011, PT:016C, BT:023C, PV:112659, M:Bike On 02511 12/03/2025 06:16:53 SOC:2714,65542,2704,114800,98,95,96,50 02512 12/03/2025 06:17:53 Discharge level 003 AH, SOC: 95%, I:-32A, L:4068, l:4111, H:4073, B:005, PT:017C, BT:023C, PV:114004, M:Bike On 02513 12/03/2025 06:17:53 SOC:3700,64109,3786,114800,97,99,95,42 02514 12/03/2025 06:18:53 Discharge level 004 AH, SOC: 94%, I: 27A, L:3954, l:4014, H:3973, B:019, PT:018C, BT:023C, PV:111007, M:Bike On 02515 12/03/2025 06:18:53 SOC:4355,63261,4461,114800,97,89,94,58 02516 12/03/2025 06:19:53 Discharge level 004 AH, SOC: 93%, I: 34A, L:3925, l:3978, H:3951, B:026, PT:018C, BT:023C, PV:110317, M:Bike On 02517 12/03/2025 06:19:53 SOC:4630,62772,4758,114800,96,86,93,53 02518 12/03/2025 06:20:53 Discharge level 005 AH, SOC: 92%, I: 1A, L:3961, l:4000, H:3984, B:023, PT:018C, BT:023C, PV:111306, M:Bike On 02519 12/03/2025 06:20:53 SOC:5111,62111,5258,114800,96,88,92,40 02520 12/03/2025 06:21:53 Discharge level 005 AH, SOC: 92%, I: 1A, L:4020, l:4038, H:4029, B:009, PT:018C, BT:023C, PV:112724, M:Bike On 02521 12/03/2025 06:21:53 SOC:5193,61932,5386,114800,96,92,92,19 02522 12/03/2025 06:22:53 Discharge level 005 AH, SOC: 92%, I: 1A, L:4016, l:4035, H:4026, B:010, PT:018C, BT:022C, PV:112637, M:Bike On 02523 12/03/2025 06:22:53 SOC:5430,61546,5685,114800,96,91,92,19 02524 12/03/2025 06:23:53 Discharge level 005 AH, SOC: 91%, I: 1A, L:4015, l:4036, H:4024, B:009, PT:018C, BT:023C, PV:112573, M:Bike On 02525 12/03/2025 06:23:53 SOC:5630,61276,5919,114800,95,91,91,21 02526 12/03/2025 06:24:53 Discharge level 006 AH, SOC: 91%, I: 1A, L:4020, l:4032, H:4028, B:008, PT:018C, BT:023C, PV:112712, M:Bike On 02527 12/03/2025 06:24:53 SOC:5721,61164,6039,114800,95,91,91,12 02528 12/03/2025 06:25:01 Contactor was Opened Pack V: 112744mV, Switched V: 112758mV, Prechg Pct: 100%, Dischg Cur: 1182mA 02529 12/03/2025 06:25:02 System Turned Off 02530 12/03/2025 06:25:03 DEBUG: CAN Link Is Down 02531 12/03/2025 06:25:03 DEBUG: Entered Idle State 02532 12/03/2025 06:25:09 Current Sensor Zeroed old: 2504mV, new: 2504mV, corrfact: 252 02533 12/03/2025 06:25:10 Discharge level 006 AH, SOC: 91%, I: 0A, L:4023, l:4033, H:4032, B:009, PT:018C, BT:022C, PV:112758, M:Idle 02534 12/03/2025 06:25:10 SOC:5723,61171,6041,114800,95,91,91,10 02535 12/03/2025 06:25:31 Voltage Across Contacto error passive mo 02536 12/03/2025 06:39:54 Discharge level 006 AH, SOC: 91%, I: 0A, L:4040, l:4051, H:4046, B:006, PT:018C, BT:033C, PV:113262, M:Bike On 02537 12/03/2025 06:39:54 SOC:5722,61171,6041,114800,95,93,91,11 02538 12/03/2025 06:39:57 DEBUG: CAN Receiving Syncs 02539 12/03/2025 06:39:58 Contactor drive turned on Pack V: 113225mV, Switched V: 99052mV, Duty Cycle: 35% 02540 12/03/2025 06:39:58 Contactor was Closed Pack V: 113225mV, Switched V: 99052mV, Prechg Pct: 87%, Dischg Cur: 818mA 02541 12/03/2025 06:40:54 Discharge level 006 AH, SOC: 91%, I: 14A, L:4018, l:4036, H:4028, B:010, PT:018C, BT:031C, PV:112705, M:Bike On 02542 12/03/2025 06:40:54 SOC:5746,61454,6076,114800,95,91,91,18 02543 12/03/2025 06:41:54 Discharge level 006 AH, SOC: 91%, I: 1A, L:4030, l:4040, H:4038, B:008, PT:018C, BT:029C, PV:113000, M:Bike On 02544 12/03/2025 06:41:54 SOC:5928,61453,6279,114800,95,92,91,10 02545 12/03/2025 06:42:54 Discharge level 006 AH, SOC: 91%, I: 1A, L:4008, l:4028, H:4020, B:012, PT:018C, BT:029C, PV:112458, M:Bike On 02546 12/03/2025 06:42:54 SOC:6090,61537,6443,114800,95,91,91,20 02547 12/03/2025 06:43:54 Discharge level 006 AH, SOC: 91%, I: 1A, L:4023, l:4034, H:4031, B:008, PT:018C, BT:028C, PV:112817, M:Bike On 02548 12/03/2025 06:43:54 SOC:6146,61526,6554,114800,95,91,91,12 02549 12/03/2025 06:44:54 Discharge level 006 AH, SOC: 90%, I: 1A, L:4019, l:4030, H:4027, B:008, PT:018C, BT:027C, PV:112701, M:Bike On 02550 12/03/2025 06:44:54 SOC:6249,61432,6720,114800,95,91,90,11 02551 12/03/2025 06:45:54 Discharge level 006 AH, SOC: 90%, I: 68A, L:3911, l:3984, H:3935, B:024, PT:018C, BT:026C, PV:109886, M:Bike On 02552 12/03/2025 06:45:54 SOC:6407,61242,6950,114800,94,87,90,73 02553 12/03/2025 06:46:54 Discharge level 008 AH, SOC: 88%, I: 1A, L:3893, l:3976, H:3916, B:023, PT:019C, BT:026C, PV:109389, M:Bike On 02554 12/03/2025 06:46:54 SOC:7409,60092,8051,114800,93,85,88,82 02555 12/03/2025 06:47:54 Discharge level 009 AH, SOC: 86%, I: 47A, L:3859, l:3952, H:3885, B:026, PT:020C, BT:025C, PV:108472, M:Bike On 02556 12/03/2025 06:47:54 SOC:8740,58975,9545,114800,92,83,86,97 02557 12/03/2025 06:48:54 Discharge level 010 AH, SOC: 85%, I: 32A, L:3890, l:3952, H:3912, B:022, PT:020C, BT:025C, PV:109294, M:Bike On 02558 12/03/2025 06:48:54 SOC:9321,58585,10201,114800,92,83,85,65 02559 12/03/2025 06:49:54 Discharge level 011 AH, SOC: 82%, I: 0A, L:3901, l:3969, H:3917, B:016, PT:021C, BT:025C, PV:109532, M:Bike On 02560 12/03/2025 06:49:54 SOC:10472,57618,11513,114800,90,85,82,76 02561 12/03/2025 06:50:54 Discharge level 011 AH, SOC: 82%, I: 67A, L:3810, l:3894, H:3846, B:036, PT:021C, BT:024C, PV:107300, M:Bike On 02562 12/03/2025 06:50:54 SOC:10635,57723,11746,114800,90,78,82,93 02563 12/03/2025 06:51:54 Discharge level 012 AH, SOC: 82%, I: 28A, L:3889, l:3937, H:3909, B:020, PT:022C, BT:025C, PV:109273, M:Bike On 02564 12/03/2025 06:51:54 SOC:10934,57667,12148,114800,90,82,82,57 02565 12/03/2025 06:52:54 Discharge level 012 AH, SOC: 81%, I: 0A, L:3910, l:3944, H:3927, B:017, PT:022C, BT:025C, PV:109825, M:Bike On 02566 12/03/2025 06:52:54 SOC:11390,57677,12656,114800,89,83,81,40 02567 12/03/2025 06:53:54 Discharge level 013 AH, SOC: 80%, I: 0A, L:3902, l:3946, H:3918, B:016, PT:022C, BT:025C, PV:109586, M:Bike On 02568 12/03/2025 06:53:54 SOC:11908,57522,13284,114800,89,83,80,52 02569 12/03/2025 06:54:54 Discharge level 013 AH, SOC: 80%, I: 1A, L:3928, l:3945, H:3941, B:013, PT:022C, BT:024C, PV:110246, M:Bike On 02570 12/03/2025 06:54:54 SOC:11868,57586,13426,114800,89,83,80,20 02571 12/03/2025 06:55:54 Discharge level 013 AH, SOC: 80%, I: 0A, L:3938, l:3947, H:3950, B:012, PT:022C, BT:024C, PV:110519, M:Bike On 02572 12/03/2025 06:55:54 SOC:11770,57846,13435,114800,89,83,80,11 02573 12/03/2025 06:56:54 Discharge level 013 AH, SOC: 80%, I: 0A, L:3943, l:3949, H:3955, B:012, PT:022C, BT:025C, PV:110652, M:Bike On 02574 12/03/2025 06:56:54 SOC:11673,58068,13446,114800,89,83,80,7 02575 12/03/2025 06:57:54 Discharge level 013 AH, SOC: 81%, I: 0A, L:3947, l:3951, H:3957, B:010, PT:022C, BT:024C, PV:110731, M:Bike On 02576 12/03/2025 06:57:55 SOC:11480,58078,13446,114800,89,84,81,5 02577 12/03/2025 06:58:54 Discharge level 013 AH, SOC: 81%, I: 0A, L:3949, l:3952, H:3959, B:010, PT:022C, BT:025C, PV:110781, M:Bike On 02578 12/03/2025 06:58:55 SOC:11273,58086,13446,114800,89,84,81,4 02579 12/03/2025 06:59:54 Discharge level 013 AH, SOC: 81%, I: 0A, L:3950, l:3953, H:3960, B:010, PT:022C, BT:024C, PV:110818, M:Bike On 02580 12/03/2025 06:59:55 SOC:11087,58094,13447,114800,89,84,81,3 02581 12/03/2025 07:00:55 Discharge level 013 AH, SOC: 82%, I: 0A, L:3952, l:3954, H:3961, B:009, PT:022C, BT:025C, PV:110849, M:Bike On 02582 12/03/2025 07:00:55 SOC:10918,58100,13447,114800,89,84,82,3 02583 12/03/2025 07:01:55 Discharge level 013 AH, SOC: 82%, I: 0A, L:3952, l:3954, H:3962, B:010, PT:022C, BT:025C, PV:110875, M:Bike On 02584 12/03/2025 07:01:55 SOC:10766,58110,13447,114800,89,84,82,2 02585 12/03/2025 07:02:55 Discharge level 013 AH, SOC: 82%, I: 0A, L:3953, l:3955, H:3962, B:009, PT:022C, BT:025C, PV:110888, M:Bike On 02586 12/03/2025 07:02:55 SOC:10628,58116,13448,114800,89,84,82,2 02587 12/03/2025 07:03:55 Discharge level 013 AH, SOC: 82%, I: 0A, L:3953, l:3954, H:3963, B:010, PT:022C, BT:026C, PV:110904, M:Bike On 02588 12/03/2025 07:03:55 SOC:10501,58118,13448,114800,89,84,82,2 02589 12/03/2025 07:04:55 Discharge level 013 AH, SOC: 83%, I: 0A, L:3955, l:3956, H:3964, B:009, PT:022C, BT:024C, PV:110919, M:Bike On 02590 12/03/2025 07:04:55 SOC:10386,58119,13448,114800,89,84,83,2 02591 12/03/2025 07:04:59 Contactor was Opened Pack V: 110916mV, Switched V: 110907mV, Prechg Pct: 100%, Dischg Cur: 818mA 02592 12/03/2025 07:04:59 System Turned Off 02593 12/03/2025 07:05:00 DEBUG: CAN Link Is Down 02594 12/03/2025 07:05:00 DEBUG: Entered Idle State 02595 12/03/2025 07:05:03 System Turned On 02596 12/03/2025 07:05:03 Rev:45,Build:2023-05-20_045619 958 banka 02597 12/03/2025 07:05:03 Pack:2019_monolith,Numbricks:4 02598 12/03/2025 07:05:03 DEBUG: Entered Running State 02599 12/03/2025 07:05:03 DEBUG: CAN NOT Receiving Syncs 02600 12/03/2025 07:05:04 DEBUG: CAN Link Is Up 02601 12/03/2025 07:05:04 DEBUG: Resetting CAN0 due to error passive mode 02602 12/03/2025 07:05:08 DEBUG: CAN Receiving Syncs 02603 12/03/2025 07:05:08 Contactor drive turned on Pack V: 110923mV, Switched V: 98540mV, Duty Cycle: 36% 02604 12/03/2025 07:05:08 Contactor was Closed Pack V: 110923mV, Switched V: 98540mV, Prechg Pct: 89%, Dischg Cur: 636mA 02605 12/03/2025 07:05:10 DEBUG: Entered Charging State 02606 12/03/2025 07:05:10 DEBUG: CAN NOT Receiving Syncs 02607 12/03/2025 07:05:11 Discharge level 013 AH, SOC: 83%, I: 0A, L:3954, l:3955, H:3964, B:010, PT:022C, BT:025C, PV:110924, M:Charge 02608 12/03/2025 07:05:11 SOC:10365,58121,13448,114800,89,84,83,1 02609 12/03/2025 07:05:11 DEBUG: CAN Receiving Syncs 02610 12/03/2025 07:15:11 Discharge level 011 AH, SOC: 89%, I:-10A, L:4016, l:3999, H:4021, B:005, PT:022C, BT:033C, PV:112536, M:Charge 02611 12/03/2025 07:15:11 SOC:6715,56357,11592,114800,90,88,89,-20 02612 12/03/2025 07:19:01 Charged To Full 010 AH, SOC: 90%, L:4026, H:4030, B:004, PT:022C, BT:035C, PV:112743 02613 12/03/2025 07:19:02 SOC adjusted for voltage old: 6024870uAH (soc:90%), new: 5075024uAH (soc:91%), low cell: 4026 mV 02614 12/03/2025 07:25:11 Discharge level 009 AH, SOC: 92%, I:-10A, L:4042, l:4026, H:4044, B:002, PT:022C, BT:033C, PV:113217, M:Charge 02615 12/03/2025 07:25:11 SOC:5017,57470,9203,114800,92,91,92,-20 02616 12/03/2025 07:35:11 Discharge level 007 AH, SOC: 94%, I:-10A, L:4065, l:4049, H:4068, B:003, PT:022C, BT:033C, PV:113853, M:Charge 02617 12/03/2025 07:35:11 SOC:3940,58220,7393,114800,94,93,94,-20 02618 12/03/2025 07:45:19 Discharge level 005 AH, SOC: 96%, I:-10A, L:4086, l:4071, H:4089, B:003, PT:022C, BT:033C, PV:114462, M:Charge 02619 12/03/2025 07:45:19 SOC:2748,58848,5592,114800,96,95,96,-19 02620 12/03/2025 07:55:19 Discharge level 003 AH, SOC: 98%, I:-10A, L:4109, l:4093, H:4112, B:003, PT:022C, BT:035C, PV:115095, M:Charge 02621 12/03/2025 07:55:19 SOC:1561,59445,3825,114800,97,97,98,-20 02622 12/03/2025 08:28:30 DEBUG: CAN Link Is Down 02623 12/03/2025 08:28:34 Contactor was Opened Pack V: 116137mV, Switched V: 116066mV, Prechg Pct: 100%, Dischg Cur: 363mA 02624 12/03/2025 08:28:34 DEBUG: CAN Link Is Up 02625 12/03/2025 08:28:37 System Turned Off 02626 12/03/2025 08:28:37 DEBUG: CAN Link Is Down 02627 12/03/2025 08:28:38 DEBUG: Entered Idle State 02628 12/03/2025 08:28:44 Discharge level 000 AH, SOC:100%, I: 0A, L:4146, l:4143, H:4149, B:003, PT:022C, BT:033C, PV:116005, M:Idle 02629 12/03/2025 08:28:44 SOC:0,60126,0,114800,100,100,100,-4 02630 12/03/2025 08:29:04 Voltage Across Contactor: 103133mV (Okay) 02631 12/03/2025 09:23:12 System Turned On 02632 12/03/2025 09:23:12 Rev:45,Build:2023-05-20_045619 958 banka 02633 12/03/2025 09:23:12 Pack:2019_monolith,Numbricks:4 02634 12/03/2025 09:23:12 DEBUG: Entered Charging State 02635 12/03/2025 09:23:12 DEBUG: CAN NOT Receiving Syncs 02636 12/03/2025 09:23:12 DEBUG: Entered Running State 02637 12/03/2025 09:23:12 DEBUG: CAN Link Is Up 02638 12/03/2025 09:23:13 DEBUG: Resetting CAN0 due to error passive mode 02639 12/03/2025 09:23:13 Discharge level 000 AH, SOC:100%, I: 0A, L:4131, l:4129, H:4134, B:003, PT:021C, BT:028C, PV:115723, M:Bike On 02640 12/03/2025 09:23:13 SOC:0,60126,0,114800,100,100,100,-3 02641 12/03/2025 09:23:16 DEBUG: CAN Receiving Syncs 02642 12/03/2025 09:23:21 Contactor drive turned on Pack V: 115711mV, Switched V: 102084mV, Duty Cycle: 34% 02643 12/03/2025 09:23:21 Contactor was Closed Pack V: 115711mV, Switched V: 102084mV, Prechg Pct: 88%, Dischg Cur: 636mA 02644 12/03/2025 09:24:13 Discharge level 000 AH, SOC:100%, I: 0A, L:4129, l:4129, H:4132, B:003, PT:021C, BT:027C, PV:115672, M:Bike On 02645 12/03/2025 09:24:13 SOC:13,60120,15,114800,100,100,100,0 02646 12/03/2025 09:25:13 Discharge level 000 AH, SOC:100%, I: 1A, L:4119, l:4128, H:4123, B:004, PT:021C, BT:027C, PV:115405, M:Bike On 02647 12/03/2025 09:25:13 SOC:181,59921,188,114800,100,100,100,12 02648 12/03/2025 09:26:13 Discharge level 000 AH, SOC:100%, I: 8A, L:4093, l:4107, H:4101, B:008, PT:021C, BT:027C, PV:114733, M:Bike On 02649 12/03/2025 09:26:13 SOC:481,59543,500,114800,100,98,100,18 02650 12/03/2025 09:27:13 Discharge level 000 AH, SOC: 99%, I: 1A, L:4107, l:4117, H:4112, B:005, PT:021C, BT:026C, PV:115073, M:Bike On 02651 12/03/2025 09:27:13 SOC:653,59322,686,114800,100,99,99,13 02652 12/03/2025 09:28:13 Discharge level 000 AH, SOC: 99%, I: 1A, L:4110, l:4116, H:4115, B:005, PT:021C, BT:027C, PV:115167, M:Bike On 02653 12/03/2025 09:28:13 SOC:676,59174,751,114800,100,99,99,8 02654 12/03/2025 09:29:13 Discharge level 000 AH, SOC: 99%, I: 1A, L:4102, l:4111, H:4108, B:006, PT:021C, BT:026C, PV:114961, M:Bike On 02655 12/03/2025 09:29:13 SOC:848,58992,936,114800,100,99,99,11 02656 12/03/2025 09:30:13 Discharge level 001 AH, SOC: 99%, I: 2A, L:4063, l:4079, H:4075, B:012, PT:021C, BT:026C, PV:113954, M:Bike On 02657 12/03/2025 09:30:13 SOC:1138,58616,1254,114800,99,96,99,21 02658 12/03/2025 09:31:13 Discharge level 001 AH, SOC: 98%, I:-12A, L:4108, l:4118, H:4111, B:003, PT:021C, BT:026C, PV:115073, M:Bike On 02659 12/03/2025 09:31:13 SOC:1612,58083,1771,114800,99,99,98,13 02660 12/03/2025 09:32:13 Discharge level 002 AH, SOC: 97%, I: 1A, L:4046, l:4063, H:4060, B:014, PT:021C, BT:026C, PV:113518, M:Bike On 02661 12/03/2025 09:32:13 SOC:1875,57738,2076,114800,99,94,97,22 02662 12/03/2025 09:33:13 Discharge level 002 AH, SOC: 97%, I: 1A, L:4081, l:4092, H:4089, B:008, PT:021C, BT:025C, PV:114416, M:Bike On 02663 12/03/2025 09:33:13 SOC:2068,57563,2287,114800,99,97,97,14 02664 12/03/2025 09:33:23 Contactor was Opened Pack V: 114463mV, Switched V: 114451mV, Prechg Pct: 100%, Dischg Cur: 909mA 02665 12/03/2025 09:33:23 System Turned Off 02666 12/03/2025 09:33:24 DEBUG: CAN Link Is Down 02667 12/03/2025 09:33:24 DEBUG: Entered Idle State 02668 12/03/2025 09:33:30 Current Sensor Zeroed old: 2504mV, new: 2506mV, corrfact: 250 02669 12/03/2025 09:33:31 Discharge level 002 AH, SOC: 97%, I: 0A, L:4086, l:4095, H:4092, B:006, PT:021C, BT:025C, PV:114415, M:Idle 02670 12/03/2025 09:33:31 SOC:2071,57578,2290,114800,99,97,97,11 02671 12/03/2025 09:33:53 Voltage Across Contactor: 101438mV (Okay) 02672 12/03/2025 10:54:22 System Turned On 02673 12/03/2025 10:54:22 Rev:45,Build:2023-05-20_045619 958 banka 02674 12/03/2025 10:54:22 Pack:2019_monolith,Numbricks:4 02675 12/03/2025 10:54:22 DEBUG: Entered Running State 02676 12/03/2025 10:54:22 DEBUG: CAN NOT Receiving Syncs 02677 12/03/2025 10:54:22 DEBUG: CAN Link Is Up 02678 12/03/2025 10:54:23 DEBUG: Resetting CAN0 due to error passive mode 02679 12/03/2025 10:54:23 Discharge level 002 AH, SOC: 97%, I: 0A, L:4101, l:4111, H:4104, B:003, PT:019C, BT:026C, PV:114880, M:Bike On 02680 12/03/2025 10:54:23 SOC:2069,57578,2290,114800,99,99,97,11 02681 12/03/2025 10:54:26 DEBUG: CAN Receiving Syncs 02682 12/03/2025 10:54:26 Contactor drive turned on Pack V: 114836mV, Switched V: 100588mV, Duty Cycle: 35% 02683 12/03/2025 10:54:26 Contactor was Closed Pack V: 114836mV, Switched V: 100588mV, Prechg Pct: 88%, Dischg Cur: 454mA 02684 12/03/2025 10:55:23 Discharge level 002 AH, SOC: 97%, I: 0A, L:4099, l:4105, H:4102, B:003, PT:019C, BT:024C, PV:114830, M:Bike On 02685 12/03/2025 10:55:23 SOC:2054,57756,2305,114800,98,98,97,7 02686 12/03/2025 10:56:23 Discharge level 002 AH, SOC: 97%, I: -3A, L:4107, l:4114, H:4110, B:003, PT:019C, BT:024C, PV:115046, M:Bike On 02687 12/03/2025 10:56:23 SOC:2086,57853,2369,114800,98,99,97,7 02688 12/03/2025 10:57:23 Discharge level 002 AH, SOC: 97%, I: 45A, L:4001, l:4041, H:4020, B:019, PT:019C, BT:025C, PV:112336, M:Bike On 02689 12/03/2025 10:57:23 SOC:2183,57636,2554,114800,98,92,97,41 02690 12/03/2025 10:58:23 Discharge level 002 AH, SOC: 96%, I: 1A, L:4069, l:4089, H:4077, B:008, PT:019C, BT:024C, PV:114066, M:Bike On 02691 12/03/2025 10:58:23 SOC:2499,57302,2902,114800,98,96,96,21 02692 12/03/2025 10:59:23 Discharge level 003 AH, SOC: 96%, I: 1A, L:4075, l:4085, H:4081, B:006, PT:019C, BT:024C, PV:114212, M:Bike On 02693 12/03/2025 10:59:23 SOC:2578,57016,3084,114800,98,96,96,11 02694 12/03/2025 11:00:23 Discharge level 003 AH, SOC: 96%, I: 1A, L:4080, l:4086, H:4085, B:005, PT:019C, BT:024C, PV:114338, M:Bike On 02695 12/03/2025 11:00:23 SOC:2583,57077,3097,114800,98,96,96,6 02696 12/03/2025 11:01:23 Discharge level 003 AH, SOC: 95%, I: 1A, L:4057, l:4088, H:4064, B:007, PT:019C, BT:023C, PV:113722, M:Bike On 02697 12/03/2025 11:01:23 SOC:2917,56748,3451,114800,97,96,95,32 02698 12/03/2025 11:02:23 Discharge level 005 AH, SOC: 92%, I:100A, L:3841, l:3972, H:3879, B:038, PT:020C, BT:022C, PV:108185, M:Bike On 02699 12/03/2025 11:02:23 SOC:4858,55051,5506,114800,96,85,92,140 02700 12/03/2025 11:03:23 Discharge level 005 AH, SOC: 91%, I: 0A, L:3996, l:4036, H:4011, B:015, PT:020C, BT:022C, PV:112154, M:Bike On 02701 12/03/2025 11:03:23 SOC:5231,54672,5967,114800,95,91,91,43 02702 12/03/2025 11:04:23 Discharge level 006 AH, SOC: 91%, I: 1A, L:4018, l:4040, H:4030, B:012, PT:021C, BT:022C, PV:112731, M:Bike On 02703 12/03/2025 11:04:23 SOC:5362,54687,6129,114800,95,92,91,23 02704 12/03/2025 11:05:23 Discharge level 007 AH, SOC: 89%, I: 1A, L:3946, l:3999, H:3968, B:022, PT:021C, BT:023C, PV:110898, M:Bike On 02705 12/03/2025 11:05:23 SOC:6452,53999,7274,114800,94,88,89,60 02706 12/03/2025 11:06:23 Discharge level 007 AH, SOC: 88%, I: 61A, L:3902, l:3972, H:3934, B:032, PT:021C, BT:023C, PV:109842, M:Bike On 02707 12/03/2025 11:06:23 SOC:6752,53916,7623,114800,94,85,88,78 02708 12/03/2025 11:07:23 Discharge level 007 AH, SOC: 88%, I: 1A, L:4003, l:4021, H:4014, B:011, PT:021C, BT:023C, PV:112298, M:Bike On 02709 12/03/2025 11:07:23 SOC:6788,53932,7767,114800,94,90,88,21 02710 12/03/2025 11:08:20 Contactor was Opened Pack V: 112521mV, Switched V: 112521mV, Prechg Pct: 100%, Dischg Cur: 1000mA 02711 12/03/2025 11:08:21 System Turned Off 02712 12/03/2025 11:08:21 DEBUG: CAN Link Is Down 02713 12/03/2025 11:08:21 DEBUG: Entered Idle State 02714 12/03/2025 11:08:25 System Turned On 02715 12/03/2025 11:08:25 Rev:45,Build:2023-05-20_045619 958 banka 02716 12/03/2025 11:08:25 Pack:2019_monolith,Numbricks:4 02717 12/03/2025 11:08:25 DEBUG: Entered Running State 02718 12/03/2025 11:08:25 DEBUG: CAN NOT Receiving Syncs 02719 12/03/2025 11:08:25 Discharge level 007 AH, SOC: 88%, I: 0A, L:4014, l:4024, H:4023, B:009, PT:021C, BT:023C, PV:112578, M:Bike On 02720 12/03/2025 11:08:25 SOC:6770,54200,7784,114800,94,90,88,12 02721 12/03/2025 11:08:25 DEBUG: CAN Link Is Up 02722 12/03/2025 11:08:26 DEBUG: Resetting CAN0 due to error passive mode 02723 12/03/2025 11:08:29 DEBUG: CAN Receiving Syncs 02724 12/03/2025 11:08:29 Contactor drive turned on Pack V: 112561mV, Switched V: 99800mV, Duty Cycle: 35% 02725 12/03/2025 11:08:29 Contactor was Closed Pack V: 112561mV, Switched V: 99800mV, Prechg Pct: 89%, Dischg Cur: 363mA 02726 12/03/2025 11:08:36 DEBUG: Entered Charging State 02727 12/03/2025 11:08:36 DEBUG: CAN NOT Receiving Syncs 02728 12/03/2025 11:08:37 Discharge level 007 AH, SOC: 88%, I: 0A, L:4015, l:4025, H:4023, B:008, PT:021C, BT:021C, PV:112584, M:Charge 02729 12/03/2025 11:08:37 SOC:6746,54201,7784,114800,94,90,88,11 02730 12/03/2025 11:08:37 DEBUG: CAN Receiving Syncs 02731 12/03/2025 11:08:46 Charged To Full 007 AH, SOC: 88%, L:4051, H:4054, B:003, PT:021C, BT:022C, PV:113478 02732 12/03/2025 11:08:46 SOC adjusted for voltage old: 6712417uAH (soc:88%), new: 3793275uAH (soc:93%), low cell: 4051 mV 02733 12/03/2025 11:18:37 Discharge level 003 AH, SOC:100%, I:-20A, L:4150, l:4115, H:4163, B:013, PT:022C, BT:035C, PV:116338, M:Charge 02734 12/03/2025 11:18:37 SOC:0,54813,3513,114800,97,99,100,-41 02735 12/03/2025 11:28:37 Discharge level 001 AH, SOC:100%, I: -8A, L:4154, l:4139, H:4162, B:008, PT:022C, BT:038C, PV:116411, M:Charge 02736 12/03/2025 11:28:37 SOC:0,54871,1229,114800,99,100,100,-17 02737 12/03/2025 11:30:27 DEBUG: CAN Link Is Down 02738 12/03/2025 11:30:32 Contactor was Opened Pack V: 115698mV, Switched V: 115908mV, Prechg Pct: 100%, Dischg Cur: 454mA 02739 12/03/2025 11:30:32 DEBUG: CAN Link Is Up 02740 12/03/2025 11:30:34 System Turned Off 02741 12/03/2025 11:30:35 DEBUG: CAN Link Is Down 02742 12/03/2025 11:30:35 DEBUG: Entered Idle State 02743 12/03/2025 11:30:41 Current Sensor Zeroed old: 2506mV, new: 2507mV, corrfact: 249 02744 12/03/2025 11:30:42 Discharge level 000 AH, SOC:100%, I: 0A, L:4140, l:4133, H:4143, B:003, PT:022C, BT:038C, PV:115834, M:Idle 02745 12/03/2025 11:30:42 SOC:0,54871,979,114800,100,100,100,-8 02746 12/03/2025 11:31:02 Voltage Across Contactor: 102707mV (Okay) 02747 12/03/2025 11:40:01 System Turned On 02748 12/03/2025 11:40:01 Rev:45,Build:2023-05-20_045619 958 banka 02749 12/03/2025 11:40:01 Pack:2019_monolith,Numbricks:4 02750 12/03/2025 11:40:01 DEBUG: Entered Charging State 02751 12/03/2025 11:40:01 DEBUG: CAN NOT Receiving Syncs 02752 12/03/2025 11:40:01 DEBUG: Entered Running State 02753 12/03/2025 11:40:01 DEBUG: CAN Link Is Up 02754 12/03/2025 11:40:02 DEBUG: Resetting CAN0 due to error passive mode 02755 12/03/2025 11:40:02 Discharge level 000 AH, SOC:100%, I: 0A, L:4127, l:4121, H:4130, B:003, PT:021C, BT:032C, PV:115613, M:Bike On 02756 12/03/2025 11:40:02 SOC:0,54871,979,114800,100,100,100,-7 02757 12/03/2025 11:40:05 DEBUG: CAN Receiving Syncs 02758 12/03/2025 11:40:06 Contactor drive turned on Pack V: 115594mV, Switched V: 101257mV, Duty Cycle: 34% 02759 12/03/2025 11:40:06 Contactor was Closed Pack V: 115594mV, Switched V: 101257mV, Prechg Pct: 88%, Dischg Cur: 545mA 02760 12/03/2025 11:41:02 Discharge level 000 AH, SOC:100%, I: 1A, L:4123, l:4121, H:4127, B:004, PT:021C, BT:030C, PV:115514, M:Bike On 02761 12/03/2025 11:41:02 SOC:5,54869,986,114800,100,100,100,-2 02762 12/03/2025 11:42:02 Discharge level 001 AH, SOC:100%, I: 0A, L:4115, l:4118, H:4120, B:005, PT:021C, BT:028C, PV:115299, M:Bike On 02763 12/03/2025 11:42:02 SOC:84,54777,1066,114800,100,99,100,3 02764 12/03/2025 11:43:02 Discharge level 001 AH, SOC:100%, I: 1A, L:4118, l:4122, H:4122, B:004, PT:021C, BT:027C, PV:115362, M:Bike On 02765 12/03/2025 11:43:02 SOC:263,54463,1256,114800,99,100,100,4 02766 12/03/2025 11:44:02 Discharge level 001 AH, SOC:100%, I: -2A, L:4122, l:4127, H:4125, B:003, PT:021C, BT:027C, PV:115435, M:Bike On 02767 12/03/2025 11:44:02 SOC:400,54212,1406,114800,99,100,100,6 02768 12/03/2025 11:45:02 Discharge level 001 AH, SOC: 99%, I: 1A, L:4102, l:4111, H:4107, B:005, PT:021C, BT:027C, PV:114961, M:Bike On 02769 12/03/2025 11:45:02 SOC:624,53842,1651,114800,99,98,99,10 02770 12/03/2025 11:46:02 Discharge level 001 AH, SOC: 99%, I: 77A, L:3973, l:4023, H:4004, B:031, PT:021C, BT:027C, PV:111764, M:Bike On 02771 12/03/2025 11:46:02 SOC:657,53801,1694,114800,99,90,99,58 02772 12/03/2025 11:47:02 Discharge level 002 AH, SOC: 97%, I:140A, L:3798, l:3933, H:3855, B:057, PT:021C, BT:025C, PV:107292, M:Bike On 02773 12/03/2025 11:47:02 SOC:1592,52779,2640,114800,98,81,97,156 02774 12/03/2025 11:48:02 Discharge level 004 AH, SOC: 94%, I: 0A, L:4004, l:4072, H:4020, B:016, PT:022C, BT:026C, PV:112412, M:Bike On 02775 12/03/2025 11:48:02 SOC:3386,51158,4435,114800,97,95,94,79 02776 12/03/2025 11:49:02 Discharge level 006 AH, SOC: 90%, I: 97A, L:3785, l:3932, H:3841, B:056, PT:022C, BT:025C, PV:106966, M:Bike On 02777 12/03/2025 11:49:02 SOC:5416,49723,6466,114800,95,82,90,179 02778 12/03/2025 11:50:02 Discharge level 008 AH, SOC: 85%, I:122A, L:3721, l:3893, H:3785, B:064, PT:023C, BT:025C, PV:105338, M:Bike On 02779 12/03/2025 11:50:02 SOC:7399,48682,8451,114800,93,78,85,206 02780 12/03/2025 11:51:02 Discharge level 010 AH, SOC: 81%, I:143A, L:3662, l:3870, H:3736, B:074, PT:023C, BT:024C, PV:103915, M:Bike On 02781 12/03/2025 11:51:02 SOC:9500,47966,10554,114800,91,76,81,246 02782 12/03/2025 11:52:02 Discharge level 012 AH, SOC: 75%, I:145A, L:3638, l:3846, H:3714, B:076, PT:024C, BT:025C, PV:103307, M:Bike On 02783 12/03/2025 11:52:02 SOC:11896,47551,12952,114800,89,73,75,250 02784 12/03/2025 11:53:02 Discharge level 015 AH, SOC: 71%, I:128A, L:3657, l:3851, H:3731, B:074, PT:025C, BT:025C, PV:103834, M:Bike On 02785 12/03/2025 11:53:02 SOC:13953,47707,15010,114800,87,73,71,231 02786 12/03/2025 11:54:02 Discharge level 017 AH, SOC: 67%, I:131A, L:3625, l:3823, H:3702, B:077, PT:026C, BT:023C, PV:103035, M:Bike On 02787 12/03/2025 11:54:02 SOC:16191,48090,17249,114800,85,70,67,245 02788 12/03/2025 11:55:02 Discharge level 019 AH, SOC: 63%, I:169A, L:3561, l:3782, H:3650, B:089, PT:026C, BT:025C, PV:101469, M:Bike On 02789 12/03/2025 11:55:03 SOC:18479,48696,19541,114800,83,65,63,275 02790 12/03/2025 11:56:03 Discharge level 021 AH, SOC: 59%, I:113A, L:3631, l:3794, H:3700, B:069, PT:027C, BT:024C, PV:103074, M:Bike On 02791 12/03/2025 11:56:03 SOC:20567,49616,21645,114800,82,67,59,213 02792 12/03/2025 11:57:03 Discharge level 024 AH, SOC: 55%, I:112A, L:3596, l:3771, H:3669, B:073, PT:028C, BT:023C, PV:102198, M:Bike On 02793 12/03/2025 11:57:03 SOC:22988,50490,24092,114800,80,64,55,241 02794 12/03/2025 11:58:03 Discharge level 026 AH, SOC: 52%, I:137A, L:3556, l:3734, H:3637, B:081, PT:028C, BT:024C, PV:101236, M:Bike On 02795 12/03/2025 11:58:03 SOC:25034,51783,26140,114800,78,60,52,248 02796 12/03/2025 11:59:03 Discharge level 027 AH, SOC: 50%, I: 96A, L:3598, l:3736, H:3666, B:068, PT:029C, BT:025C, PV:102166, M:Bike On 02797 12/03/2025 11:59:03 SOC:26849,53266,27964,114800,76,60,50,202 02798 12/03/2025 12:00:03 Discharge level 029 AH, SOC: 49%, I:114A, L:3581, l:3719, H:3650, B:069, PT:029C, BT:023C, PV:101696, M:Bike On 02799 12/03/2025 12:00:03 SOC:28372,54873,29517,114800,75,58,49,203 02800 12/03/2025 12:01:03 Discharge level 031 AH, SOC: 47%, I:116A, L:3554, l:3698, H:3627, B:073, PT:030C, BT:025C, PV:101028, M:Bike On 02801 12/03/2025 12:01:03 SOC:30128,56397,31282,114800,73,55,47,213 02802 12/03/2025 12:01:03 Discharge cutback 87% 02803 12/03/2025 12:01:03 746A 02804 12/03/2025 12:02:03 Discharge level 032 AH, SOC: 46%, I: 69A, L:3628, l:3722, H:3675, B:047, PT:030C, BT:025C, PV:102578, M:Bike On 02805 12/03/2025 12:02:03 SOC:31485,57474,32869,114800,72,59,46,145 02806 12/03/2025 12:02:03 Discharge cutback 87% 02807 12/03/2025 12:02:03 749A 02808 12/03/2025 12:03:03 Discharge level 034 AH, SOC: 45%, I: 74A, L:3611, l:3700, H:3663, B:052, PT:030C, BT:025C, PV:102220, M:Bike On 02809 12/03/2025 12:03:03 SOC:32406,58599,34026,114800,71,56,45,138 02810 12/03/2025 12:03:03 Discharge cutback 89% 02811 12/03/2025 12:03:03 766A 02812 12/03/2025 12:04:03 Discharge level 035 AH, SOC: 45%, I: 0A, L:3670, l:3740, H:3698, B:028, PT:031C, BT:025C, PV:103397, M:Bike On 02813 12/03/2025 12:04:03 SOC:33308,60036,35080,114800,70,61,45,108 02814 12/03/2025 12:04:03 Discharge cutback 80% 02815 12/03/2025 12:04:03 685A 02816 12/03/2025 12:05:03 Discharge level 036 AH, SOC: 44%, I:108A, L:3554, l:3659, H:3615, B:061, PT:031C, BT:025C, PV:100801, M:Bike On 02817 12/03/2025 12:05:03 SOC:34481,61287,36359,114800,69,50,44,169 02818 12/03/2025 12:05:03 Discharge cutback 85% 02819 12/03/2025 12:05:03 729A 02820 12/03/2025 12:06:03 Discharge level 038 AH, SOC: 40%, I: 1A, L:3607, l:3698, H:3645, B:038, PT:032C, BT:025C, PV:101828, M:Bike On 02821 12/03/2025 12:06:03 SOC:37058,61097,38999,114800,67,56,40,147 02822 12/03/2025 12:06:03 Discharge cutback 67% 02823 12/03/2025 12:06:03 574A 02824 12/03/2025 12:07:03 Discharge level 039 AH, SOC: 41%, I:-15A, L:3663, l:3711, H:3687, B:024, PT:032C, BT:025C, PV:103088, M:Bike On 02825 12/03/2025 12:07:03 SOC:36930,61966,39441,114800,66,58,41,78 02826 12/03/2025 12:07:03 Discharge cutback 76% 02827 12/03/2025 12:07:03 655A 02828 12/03/2025 12:08:03 Discharge level 039 AH, SOC: 43%, I: 0A, L:3675, l:3701, H:3697, B:022, PT:032C, BT:026C, PV:103382, M:Bike On 02829 12/03/2025 12:08:03 SOC:36495,63247,39552,114800,66,57,43,42 02830 12/03/2025 12:08:49 Contactor was Opened Pack V: 103619mV, Switched V: 103581mV, Prechg Pct: 100%, Dischg Cur: 1273mA 02831 12/03/2025 12:08:50 System Turned Off 02832 12/03/2025 12:08:51 DEBUG: CAN Link Is Down 02833 12/03/2025 12:08:51 DEBUG: Entered Idle State 02834 12/03/2025 12:08:56 Current Sensor Zeroed old: 2507mV, new: 2505mV, corrfact: 251 02835 12/03/2025 12:08:58 Discharge level 039 AH, SOC: 44%, I: 0A, L:3688, l:3705, H:3706, B:018, PT:032C, BT:026C, PV:103670, M:Idle 02836 12/03/2025 12:08:58 SOC:36337,64714,39570,114800,66,57,44,27 02837 12/03/2025 12:09:19 Voltage Across Contactor: 90664mV (Okay) 02838 12/03/2025 12:09:47 System Turned On 02839 12/03/2025 12:09:47 Rev:45,Build:2023-05-20_045619 958 banka 02840 12/03/2025 12:09:47 Pack:2019_monolith,Numbricks:4 02841 12/03/2025 12:09:47 DEBUG: Entered Running State 02842 12/03/2025 12:09:47 DEBUG: CAN NOT Receiving Syncs 02843 12/03/2025 12:09:47 DEBUG: CAN Link Is Up 02844 12/03/2025 12:09:48 DEBUG: Resetting CAN0 due to error passive mode 02845 12/03/2025 12:09:48 Discharge level 039 AH, SOC: 44%, I: 0A, L:3693, l:3710, H:3711, B:018, PT:032C, BT:026C, PV:103800, M:Bike On 02846 12/03/2025 12:09:48 SOC:36327,64714,39570,114800,66,58,44,27 02847 12/03/2025 12:09:51 DEBUG: CAN Receiving Syncs 02848 12/03/2025 12:09:52 Contactor drive turned on Pack V: 103805mV, Switched V: 91057mV, Duty Cycle: 38% 02849 12/03/2025 12:09:52 Contactor was Closed Pack V: 103805mV, Switched V: 91057mV, Prechg Pct: 88%, Dischg Cur: 727mA 02850 12/03/2025 12:09:53 DEBUG: Entered Charging State 02851 12/03/2025 12:09:53 DEBUG: CAN NOT Receiving Syncs 02852 12/03/2025 12:09:54 Discharge level 039 AH, SOC: 45%, I: 1A, L:3694, l:3710, H:3711, B:017, PT:032C, BT:025C, PV:103811, M:Charge 02853 12/03/2025 12:09:54 SOC:36278,64792,39571,114800,66,58,45,26 02854 12/03/2025 12:09:55 DEBUG: CAN Receiving Syncs 02855 12/03/2025 12:19:54 Discharge level 037 AH, SOC: 59%, I:-11A, L:3755, l:3742, H:3761, B:006, PT:032C, BT:033C, PV:105251, M:Charge 02856 12/03/2025 12:19:54 SOC:21623,52176,37645,114800,68,63,59,-20 02857 12/03/2025 12:29:54 Discharge level 035 AH, SOC: 66%, I:-11A, L:3780, l:3766, H:3786, B:006, PT:031C, BT:038C, PV:105936, M:Charge 02858 12/03/2025 12:29:54 SOC:17342,49849,35709,114800,69,65,66,-21 02859 12/03/2025 12:39:54 Discharge level 033 AH, SOC: 69%, I:-11A, L:3803, l:3789, H:3811, B:008, PT:031C, BT:039C, PV:106564, M:Charge 02860 12/03/2025 12:39:54 SOC:15769,50218,33784,114800,71,68,69,-21 02861 12/03/2025 12:50:02 Discharge level 031 AH, SOC: 72%, I:-11A, L:3827, l:3813, H:3836, B:009, PT:031C, BT:040C, PV:107253, M:Charge 02862 12/03/2025 12:50:02 SOC:14746,51153,31843,114800,73,70,72,-21 02863 12/03/2025 13:00:02 Discharge level 029 AH, SOC: 74%, I:-11A, L:3851, l:3836, H:3861, B:010, PT:030C, BT:040C, PV:107938, M:Charge 02864 12/03/2025 13:00:02 SOC:13752,52071,29949,114800,74,73,74,-21 02865 12/03/2025 13:10:02 Discharge level 028 AH, SOC: 76%, I:-11A, L:3877, l:3862, H:3884, B:007, PT:030C, BT:040C, PV:108635, M:Charge 02866 12/03/2025 13:10:02 SOC:12720,52923,28084,114800,76,75,76,-21 02867 12/03/2025 13:20:02 Discharge level 026 AH, SOC: 79%, I:-10A, L:3901, l:3886, H:3906, B:005, PT:030C, BT:041C, PV:109287, M:Charge 02868 12/03/2025 13:20:02 SOC:11625,53689,26242,114800,78,78,79,-20 02869 12/03/2025 13:30:02 Discharge level 024 AH, SOC: 81%, I:-11A, L:3922, l:3907, H:3927, B:005, PT:029C, BT:043C, PV:109915, M:Charge 02870 12/03/2025 13:30:02 SOC:10602,54525,24402,114800,79,80,81,-21 02871 12/03/2025 13:40:02 Discharge level 022 AH, SOC: 83%, I:-10A, L:3943, l:3929, H:3948, B:005, PT:029C, BT:044C, PV:110493, M:Charge 02872 12/03/2025 13:40:02 SOC:9795,55569,22571,114800,81,82,83,-20 02873 12/03/2025 13:50:02 Discharge level 020 AH, SOC: 85%, I:-11A, L:3962, l:3947, H:3967, B:005, PT:028C, BT:045C, PV:111040, M:Charge 02874 12/03/2025 13:50:02 SOC:8994,56605,20753,114800,82,83,85,-20 02875 12/03/2025 14:00:10 Discharge level 018 AH, SOC: 86%, I:-11A, L:3983, l:3968, H:3987, B:004, PT:028C, BT:043C, PV:111598, M:Charge 02876 12/03/2025 14:00:10 SOC:8053,57521,18914,114800,84,85,86,-20 02877 12/03/2025 14:10:10 Discharge level 017 AH, SOC: 88%, I:-10A, L:4002, l:3988, H:4006, B:004, PT:028C, BT:038C, PV:112116, M:Charge 02878 12/03/2025 14:10:10 SOC:7197,58462,17137,114800,86,87,88,-19 02879 12/03/2025 14:20:10 Discharge level 015 AH, SOC: 90%, I:-11A, L:4023, l:4008, H:4025, B:002, PT:027C, BT:033C, PV:112669, M:Charge 02880 12/03/2025 14:20:10 SOC:6215,59253,15383,114800,87,89,90,-20 02881 12/03/2025 14:21:18 Charged To Full 015 AH, SOC: 90%, L:4025, H:4027, B:002, PT:027C, BT:033C, PV:112734 02882 12/03/2025 14:21:18 SOC adjusted for voltage old: 6121847uAH (soc:90%), new: 5936185uAH (soc:90%), low cell: 4025 mV 02883 12/03/2025 14:30:10 Discharge level 009 AH, SOC: 92%, I:-10A, L:4042, l:4028, H:4045, B:003, PT:027C, BT:031C, PV:113215, M:Charge 02884 12/03/2025 14:30:10 SOC:5197,60190,9930,114800,92,91,92,-19 02885 12/03/2025 14:40:10 Discharge level 008 AH, SOC: 94%, I:-10A, L:4062, l:4048, H:4065, B:003, PT:026C, BT:032C, PV:113777, M:Charge 02886 12/03/2025 14:40:10 SOC:4205,60967,8180,114800,93,93,94,-19 02887 12/03/2025 14:50:10 Discharge level 006 AH, SOC: 95%, I:-10A, L:4081, l:4067, H:4084, B:003, PT:026C, BT:033C, PV:114309, M:Charge 02888 12/03/2025 14:50:10 SOC:3174,61684,6452,114800,95,95,95,-19 02889 12/03/2025 15:00:10 Discharge level 004 AH, SOC: 97%, I:-10A, L:4101, l:4087, H:4105, B:004, PT:026C, BT:039C, PV:114857, M:Charge 02890 12/03/2025 15:00:10 SOC:2082,62318,4745,114800,96,96,97,-19 02891 12/03/2025 15:39:09 DEBUG: CAN Link Is Down 02892 12/03/2025 15:39:13 Contactor was Opened Pack V: 116069mV, Switched V: 116105mV, Prechg Pct: 100%, Dischg Cur: 545mA 02893 12/03/2025 15:39:13 DEBUG: CAN Link Is Up 02894 12/03/2025 15:39:16 System Turned Off 02895 12/03/2025 15:39:16 DEBUG: CAN Link Is Down 02896 12/03/2025 15:39:17 DEBUG: Entered Idle State 02897 12/03/2025 15:39:22 Current Sensor Zeroed old: 2505mV, new: 2507mV, corrfact: 249 02898 12/03/2025 15:39:24 Discharge level 000 AH, SOC:100%, I: 0A, L:4147, l:4144, H:4151, B:004, PT:025C, BT:035C, PV:116022, M:Idle 02899 12/03/2025 15:39:24 SOC:0,63242,0,114800,100,100,100,-4 02900 12/03/2025 15:39:43 Voltage Across Contactor: 103106mV (Okay) 02901 12/03/2025 21:51:05 System Turned On 02902 12/03/2025 21:51:05 Rev:45,Build:2023-05-20_045619 958 banka 02903 12/03/2025 21:51:05 Pack:2019_monolith,Numbricks:4 02904 12/03/2025 21:51:05 DEBUG: Entered Charging State 02905 12/03/2025 21:51:05 DEBUG: CAN NOT Receiving Syncs 02906 12/03/2025 21:51:06 DEBUG: CAN Link Is Up 02907 12/03/2025 21:51:06 DEBUG: Entered Running State 02908 12/03/2025 21:51:06 DEBUG: Resetting CAN0 due to error passive mode 02909 12/03/2025 21:51:07 Discharge level 000 AH, SOC:100%, I: 0A, L:4123, l:4118, H:4126, B:003, PT:014C, BT:017C, PV:115493, M:Bike On 02910 12/03/2025 21:51:07 SOC:0,63242,0,114800,100,99,100,-4 02911 12/03/2025 21:51:09 DEBUG: CAN Receiving Syncs 02912 12/03/2025 21:51:14 Contactor drive turned on Pack V: 115432mV, Switched V: 101494mV, Duty Cycle: 34% 02913 12/03/2025 21:51:14 Contactor was Closed Pack V: 115432mV, Switched V: 101494mV, Prechg Pct: 88%, Dischg Cur: 818mA 02914 12/03/2025 21:52:07 Discharge level 000 AH, SOC:100%, I: 1A, L:4120, l:4120, H:4123, B:003, PT:013C, BT:017C, PV:115412, M:Bike On 02915 12/03/2025 21:52:07 SOC:20,63210,11,114800,100,100,100,0 02916 12/03/2025 21:53:07 Discharge level 000 AH, SOC:100%, I: 34A, L:4010, l:4044, H:4030, B:020, PT:013C, BT:016C, PV:112568, M:Bike On 02917 12/03/2025 21:53:07 SOC:63,63144,55,114800,100,92,100,26 02918 12/03/2025 21:54:07 Discharge level 000 AH, SOC:100%, I: 49A, L:3970, l:4036, H:3997, B:027, PT:013C, BT:016C, PV:111561, M:Bike On 02919 12/03/2025 21:54:07 SOC:410,62542,354,114800,100,91,100,51 02920 12/03/2025 21:55:07 Discharge level 000 AH, SOC: 99%, I: 1A, L:3953, l:4038, H:3983, B:030, PT:014C, BT:016C, PV:111187, M:Bike On 02921 12/03/2025 21:55:07 SOC:965,61642,891,114800,100,92,99,66 02922 12/03/2025 21:55:07 Discharge cutback 79% 02923 12/03/2025 21:55:07 682A 02924 12/03/2025 21:56:07 Discharge level 001 AH, SOC: 97%, I: 85A, L:3842, l:3971, H:3882, B:040, PT:014C, BT:016C, PV:108151, M:Bike On 02925 12/03/2025 21:56:07 SOC:1809,60258,1705,114800,99,85,97,102 02926 12/03/2025 21:57:07 Discharge level 003 AH, SOC: 95%, I: 38A, L:3936, l:4029, H:3961, B:025, PT:015C, BT:016C, PV:110619, M:Bike On 02927 12/03/2025 21:57:07 SOC:3364,58314,3365,114800,98,91,95,78 02928 12/03/2025 21:58:07 Discharge level 004 AH, SOC: 93%, I: 83A, L:3797, l:3938, H:3845, B:048, PT:015C, BT:016C, PV:107068, M:Bike On 02929 12/03/2025 21:58:07 SOC:4131,57285,4118,114800,97,82,93,116 02930 12/03/2025 21:59:07 Discharge level 004 AH, SOC: 92%, I: 89A, L:3807, l:3921, H:3854, B:047, PT:015C, BT:017C, PV:107348, M:Bike On 02931 12/03/2025 21:59:07 SOC:4550,56766,4536,114800,97,80,92,94 02932 12/03/2025 22:00:07 Discharge level 005 AH, SOC: 91%, I:356A, L:3410, l:3764, H:3520, B:110, PT:016C, BT:016C, PV: 97223, M:Bike On 02933 12/03/2025 22:00:07 SOC:5501,55710,5514,114800,96,63,91,290 02934 12/03/2025 22:01:07 Discharge level 007 AH, SOC: 87%, I:365A, L:3234, l:3712, H:3376, B:142, PT:016C, BT:016C, PV: 92906, M:Bike On 02935 12/03/2025 22:01:07 SOC:7422,54176,7426,114800,94,56,87,400 02936 12/03/2025 22:01:07 Discharge cutback 49% 02937 12/03/2025 22:01:07 422A 02938 12/03/2025 22:02:07 Discharge level 008 AH, SOC: 85%, I: 67A, L:3775, l:3923, H:3824, B:049, PT:017C, BT:016C, PV:106548, M:Bike On 02939 12/03/2025 22:02:07 SOC:8386,53785,8411,114800,93,80,85,122 02940 12/03/2025 22:03:07 Discharge level 009 AH, SOC: 83%, I:101A, L:3730, l:3890, H:3788, B:058, PT:018C, BT:016C, PV:105475, M:Bike On 02941 12/03/2025 22:03:07 SOC:9278,53464,9330,114800,92,77,83,138 02942 12/03/2025 22:04:07 Discharge level 010 AH, SOC: 80%, I: 1A, L:3869, l:3990, H:3897, B:028, PT:018C, BT:017C, PV:108870, M:Bike On 02943 12/03/2025 22:04:07 SOC:10722,52912,10792,114800,91,87,80,103 02944 12/03/2025 22:04:07 Discharge cutback 85% 02945 12/03/2025 22:04:07 736A 02946 12/03/2025 22:05:07 Discharge level 013 AH, SOC: 75%, I:123A, L:3599, l:3856, H:3677, B:078, PT:019C, BT:017C, PV:102228, M:Bike On 02947 12/03/2025 22:05:07 SOC:13260,52041,13341,114800,89,73,75,229 02948 12/03/2025 22:05:07 Discharge cutback 85% 02949 12/03/2025 22:05:07 736A 02950 12/03/2025 22:06:07 Discharge level 014 AH, SOC: 73%, I: 0A, L:3810, l:3923, H:3847, B:037, PT:020C, BT:017C, PV:107418, M:Bike On 02951 12/03/2025 22:06:07 SOC:14453,52253,14563,114800,88,80,73,107 02952 12/03/2025 22:07:07 Discharge level 016 AH, SOC: 69%, I: 3A, L:3745, l:3892, H:3793, B:048, PT:021C, BT:017C, PV:105825, M:Bike On 02953 12/03/2025 22:07:07 SOC:16139,51924,16368,114800,86,77,69,140 02954 12/03/2025 22:07:07 Discharge cutback 83% 02955 12/03/2025 22:07:07 715A 02956 12/03/2025 22:08:07 Discharge level 018 AH, SOC: 64%, I: 9A, L:3748, l:3885, H:3787, B:039, PT:023C, BT:018C, PV:105735, M:Bike On 02957 12/03/2025 22:08:07 SOC:18683,51476,18951,114800,84,76,64,140 02958 12/03/2025 22:09:07 Discharge level 020 AH, SOC: 61%, I:145A, L:3542, l:3761, H:3630, B:088, PT:023C, BT:018C, PV:100948, M:Bike On 02959 12/03/2025 22:09:07 SOC:20512,51981,20794,114800,82,62,61,239 02960 12/03/2025 22:10:07 Discharge level 023 AH, SOC: 56%, I:368A, L:3244, l:3604, H:3401, B:157, PT:024C, BT:018C, PV: 93952, M:Bike On 02961 12/03/2025 22:10:07 SOC:22985,52195,23276,114800,80,37,56,428 02962 12/03/2025 22:10:07 Discharge cutback 72% 02963 12/03/2025 22:10:07 621A 02964 12/03/2025 22:11:07 Discharge level 025 AH, SOC: 53%, I: 81A, L:3600, l:3753, H:3667, B:067, PT:025C, BT:017C, PV:102173, M:Bike On 02965 12/03/2025 22:11:07 SOC:25099,52767,25432,114800,78,63,53,191 02966 12/03/2025 22:11:07 Discharge cutback 83% 02967 12/03/2025 22:11:07 712A 02968 12/03/2025 22:12:07 Discharge level 027 AH, SOC: 51%, I:107A, L:3566, l:3717, H:3641, B:075, PT:026C, BT:018C, PV:101413, M:Bike On 02969 12/03/2025 22:12:07 SOC:26634,53952,27000,114800,77,58,51,196 02970 12/03/2025 22:12:07 Discharge cutback 88% 02971 12/03/2025 22:12:07 756A 02972 12/03/2025 22:13:07 Discharge level 029 AH, SOC: 47%, I:107A, L:3527, l:3696, H:3606, B:079, PT:027C, BT:019C, PV:100414, M:Bike On 02973 12/03/2025 22:13:07 SOC:28921,54156,29330,114800,75,54,47,224 02974 12/03/2025 22:13:07 Discharge cutback 69% 02975 12/03/2025 22:13:07 594A 02976 12/03/2025 22:14:07 Discharge level 032 AH, SOC: 42%, I:193A, L:3382, l:3616, H:3498, B:116, PT:028C, BT:019C, PV: 97117, M:Bike On 02977 12/03/2025 22:14:07 SOC:31789,54283,32210,114800,72,39,42,327 02978 12/03/2025 22:14:07 Discharge cutback 60% 02979 12/03/2025 22:14:07 519A 02980 12/03/2025 22:15:07 Discharge level 035 AH, SOC: 37%, I:259A, L:3297, l:3557, H:3435, B:138, PT:029C, BT:019C, PV: 95217, M:Bike On 02981 12/03/2025 22:15:07 SOC:34545,54336,35050,114800,70,23,37,378 02982 12/03/2025 22:15:07 Discharge cutback 53% 02983 12/03/2025 22:15:07 455A 02984 12/03/2025 22:16:07 Discharge level 038 AH, SOC: 30%, I:164A, L:3362, l:3593, H:3478, B:116, PT:030C, BT:019C, PV: 96609, M:Bike On 02985 12/03/2025 22:16:07 SOC:38007,53922,38513,114800,67,34,30,341 02986 12/03/2025 22:16:07 Discharge cutback 45% 02987 12/03/2025 22:16:07 388A 02988 12/03/2025 22:17:07 Discharge level 039 AH, SOC: 32%, I: 40A, L:3577, l:3670, H:3628, B:051, PT:031C, BT:020C, PV:101248, M:Bike On 02989 12/03/2025 22:17:07 SOC:38224,55416,39321,114800,66,52,32,144 02990 12/03/2025 22:17:07 Discharge cutback 75% 02991 12/03/2025 22:17:07 648A 02992 12/03/2025 22:18:07 Discharge level 039 AH, SOC: 34%, I: 0A, L:3642, l:3694, H:3671, B:029, PT:031C, BT:021C, PV:102637, M:Bike On 02993 12/03/2025 22:18:07 SOC:38060,57390,39696,114800,66,56,34,80 02994 12/03/2025 22:18:07 Discharge cutback 85% 02995 12/03/2025 22:18:07 729A 02996 12/03/2025 22:19:07 Discharge level 040 AH, SOC: 36%, I: 61A, L:3579, l:3655, H:3626, B:047, PT:031C, BT:020C, PV:101232, M:Bike On 02997 12/03/2025 22:19:07 SOC:38240,58958,40357,114800,65,50,36,123 02998 12/03/2025 22:19:07 Discharge cutback 82% 02999 12/03/2025 22:19:07 705A 03000 12/03/2025 22:20:07 Discharge level 040 AH, SOC: 37%, I: 0A, L:3642, l:3682, H:3667, B:025, PT:031C, BT:021C, PV:102553, M:Bike On 03001 12/03/2025 22:20:07 SOC:38185,60186,40889,114800,65,54,37,65 03002 12/03/2025 22:20:07 Discharge cutback 85% 03003 12/03/2025 22:20:07 732A 03004 12/03/2025 22:21:07 Discharge level 041 AH, SOC: 39%, I: 0A, L:3654, l:3683, H:3676, B:022, PT:031C, BT:021C, PV:102804, M:Bike On 03005 12/03/2025 22:21:07 SOC:37782,61102,41199,114800,65,55,39,47 03006 12/03/2025 22:21:07 Discharge cutback 88% 03007 12/03/2025 22:21:07 756A 03008 12/03/2025 22:22:07 Discharge level 041 AH, SOC: 41%, I: 1A, L:3665, l:3684, H:3685, B:020, PT:031C, BT:022C, PV:103068, M:Bike On 03009 12/03/2025 22:22:07 SOC:37130,61945,41211,114800,65,55,41,31 03010 12/03/2025 22:22:50 Contactor was Opened Pack V: 103182mV, Switched V: 103148mV, Prechg Pct: 100%, Dischg Cur: 545mA 03011 12/03/2025 22:22:51 System Turned Off 03012 12/03/2025 22:22:51 DEBUG: CAN Link Is Down 03013 12/03/2025 22:22:51 DEBUG: Entered Idle State 03014 12/03/2025 22:22:55 System Turned On 03015 12/03/2025 22:22:55 Rev:45,Build:2023-05-20_045619 958 banka 03016 12/03/2025 22:22:55 Pack:2019_monolith,Numbricks:4 03017 12/03/2025 22:22:55 DEBUG: Entered Running State 03018 12/03/2025 22:22:55 DEBUG: CAN NOT Receiving Syncs 03019 12/03/2025 22:22:55 DEBUG: CAN Link Is Up 03020 12/03/2025 22:22:56 DEBUG: Resetting CAN0 due to error passive mode 03021 12/03/2025 22:22:59 DEBUG: CAN Receiving Syncs 03022 12/03/2025 22:23:00 Contactor drive turned on Pack V: 103204mV, Switched V: 91451mV, Duty Cycle: 39% 03023 12/03/2025 22:23:00 Contactor was Closed Pack V: 103204mV, Switched V: 91451mV, Prechg Pct: 89%, Dischg Cur: 363mA 03024 12/03/2025 22:23:07 Discharge level 041 AH, SOC: 42%, I: 0A, L:3672, l:3685, H:3691, B:019, PT:031C, BT:021C, PV:103218, M:Bike On 03025 12/03/2025 22:23:07 SOC:36493,62450,41215,114800,65,55,42,21 03026 12/03/2025 22:24:07 Discharge level 041 AH, SOC: 43%, I: 0A, L:3676, l:3685, H:3693, B:017, PT:031C, BT:021C, PV:103298, M:Bike On 03027 12/03/2025 22:24:07 SOC:35694,62450,41215,114800,65,55,43,15 03028 12/03/2025 22:24:39 Contactor was Opened Pack V: 103334mV, Switched V: 103305mV, Prechg Pct: 100%, Dischg Cur: 545mA 03029 12/03/2025 22:24:39 System Turned Off 03030 12/03/2025 22:24:40 DEBUG: CAN Link Is Down 03031 12/03/2025 22:24:40 DEBUG: Entered Idle State 03032 12/03/2025 22:24:46 Current Sensor Zeroed old: 2507mV, new: 2504mV, corrfact: 252 03033 12/03/2025 22:24:47 Discharge level 041 AH, SOC: 44%, I: 0A, L:3679, l:3687, H:3695, B:016, PT:031C, BT:021C, PV:103352, M:Idle 03034 12/03/2025 22:24:47 SOC:35286,62450,41215,114800,65,55,44,12 03035 12/03/2025 22:25:09 Voltage Across Contactor: 89431mV (Okay) 03036 12/03/2025 22:28:24 System Turned On 03037 12/03/2025 22:28:24 Rev:45,Build:2023-05-20_045619 958 banka 03038 12/03/2025 22:28:24 Pack:2019_monolith,Numbricks:4 03039 12/03/2025 22:28:24 DEBUG: Entered Running State 03040 12/03/2025 22:28:24 DEBUG: CAN NOT Receiving Syncs 03041 12/03/2025 22:28:24 DEBUG: CAN Link Is Up 03042 12/03/2025 22:28:25 DEBUG: Resetting CAN0 due to error passive mode 03043 12/03/2025 22:28:25 Discharge level 041 AH, SOC: 44%, I: 0A, L:3685, l:3693, H:3699, B:014, PT:031C, BT:022C, PV:103480, M:Bike On 03044 12/03/2025 22:28:25 SOC:35278,62450,41215,114800,65,56,44,12 03045 12/03/2025 22:28:28 DEBUG: CAN Receiving Syncs 03046 12/03/2025 22:28:29 Contactor drive turned on Pack V: 103475mV, Switched V: 90663mV, Duty Cycle: 38% 03047 12/03/2025 22:28:29 Contactor was Closed Pack V: 103475mV, Switched V: 90663mV, Prechg Pct: 88%, Dischg Cur: 545mA 03048 12/03/2025 22:28:30 DEBUG: Entered Charging State 03049 12/03/2025 22:28:30 DEBUG: CAN NOT Receiving Syncs 03050 12/03/2025 22:28:31 Discharge level 041 AH, SOC: 44%, I: 0A, L:3685, l:3693, H:3698, B:013, PT:031C, BT:023C, PV:103481, M:Charge 03051 12/03/2025 22:28:31 SOC:35215,62459,41215,114800,65,56,44,12 03052 12/03/2025 22:28:32 DEBUG: CAN Receiving Syncs 03053 12/03/2025 22:28:33 DEBUG: Entered Running State 03054 12/03/2025 22:28:33 DEBUG: CAN NOT Receiving Syncs 03055 12/03/2025 22:28:34 Discharge level 041 AH, SOC: 44%, I: 0A, L:3685, l:3693, H:3698, B:013, PT:031C, BT:022C, PV:103477, M:Bike On 03056 12/03/2025 22:28:34 SOC:35198,62459,41215,114800,65,56,44,12 03057 12/03/2025 22:28:34 DEBUG: CAN Receiving Syncs 03058 12/03/2025 22:28:46 DEBUG: Entered Charging State 03059 12/03/2025 22:28:46 DEBUG: CAN NOT Receiving Syncs 03060 12/03/2025 22:28:47 Discharge level 041 AH, SOC: 44%, I: 0A, L:3686, l:3693, H:3699, B:013, PT:031C, BT:023C, PV:103484, M:Charge 03061 12/03/2025 22:28:48 SOC:35029,62459,41215,114800,65,56,44,12 03062 12/03/2025 22:28:48 DEBUG: CAN Receiving Syncs 03063 12/03/2025 22:38:48 Discharge level 039 AH, SOC: 57%, I:-11A, L:3734, l:3721, H:3739, B:005, PT:031C, BT:033C, PV:104639, M:Charge 03064 12/03/2025 22:38:48 SOC:22617,52073,39305,114800,66,60,57,-20 03065 12/03/2025 22:48:48 Discharge level 037 AH, SOC: 63%, I:-11A, L:3756, l:3741, H:3761, B:005, PT:030C, BT:037C, PV:105245, M:Charge 03066 12/03/2025 22:48:48 SOC:18849,50244,37382,114800,68,63,63,-22 03067 12/03/2025 22:58:48 Discharge level 035 AH, SOC: 66%, I:-11A, L:3776, l:3761, H:3782, B:006, PT:030C, BT:039C, PV:105820, M:Charge 03068 12/03/2025 22:58:48 SOC:17368,50717,35443,114800,70,65,66,-21 03069 12/03/2025 23:08:55 Discharge level 033 AH, SOC: 69%, I:-11A, L:3797, l:3782, H:3805, B:008, PT:030C, BT:040C, PV:106408, M:Charge 03070 12/03/2025 23:08:55 SOC:16600,51928,33480,114800,71,67,69,-22 03071 12/03/2025 23:18:55 Discharge level 031 AH, SOC: 71%, I:-11A, L:3818, l:3802, H:3827, B:009, PT:030C, BT:039C, PV:107001, M:Charge 03072 12/03/2025 23:18:55 SOC:15783,53043,31563,114800,73,70,71,-21 03073 12/03/2025 23:28:55 Discharge level 029 AH, SOC: 73%, I:-11A, L:3840, l:3824, H:3850, B:010, PT:029C, BT:039C, PV:107636, M:Charge 03074 12/03/2025 23:28:55 SOC:14829,53992,29679,114800,75,72,73,-21 03075 12/03/2025 23:38:55 Discharge level 027 AH, SOC: 75%, I:-11A, L:3864, l:3849, H:3872, B:008, PT:029C, BT:040C, PV:108297, M:Charge 03076 12/03/2025 23:38:55 SOC:13839,54889,27809,114800,76,74,75,-21 03077 12/03/2025 23:48:55 Discharge level 025 AH, SOC: 78%, I:-11A, L:3890, l:3875, H:3895, B:005, PT:029C, BT:041C, PV:108979, M:Charge 03078 12/03/2025 23:48:55 SOC:12678,55607,25946,114800,78,77,78,-21 03079 12/03/2025 23:58:55 Discharge level 024 AH, SOC: 80%, I:-11A, L:3912, l:3897, H:3917, B:005, PT:029C, BT:043C, PV:109631, M:Charge 03080 12/03/2025 23:58:55 SOC:11555,56395,24053,114800,80,79,80,-21 03081 12/04/2025 00:08:55 Discharge level 022 AH, SOC: 82%, I:-11A, L:3934, l:3919, H:3939, B:005, PT:028C, BT:046C, PV:110240, M:Charge 03082 12/04/2025 00:08:55 SOC:10596,57359,22148,114800,81,81,82,-21 03083 12/04/2025 00:19:03 Discharge level 020 AH, SOC: 84%, I:-11A, L:3955, l:3939, H:3959, B:004, PT:028C, BT:045C, PV:110820, M:Charge 03084 12/04/2025 00:19:03 SOC:9720,58412,20236,114800,83,83,84,-21 03085 12/04/2025 00:29:03 Discharge level 018 AH, SOC: 86%, I:-10A, L:3974, l:3959, H:3978, B:004, PT:028C, BT:046C, PV:111353, M:Charge 03086 12/04/2025 00:29:03 SOC:8813,59373,18385,114800,84,85,86,-20 03087 12/04/2025 00:39:03 Discharge level 016 AH, SOC: 87%, I:-11A, L:3994, l:3979, H:3998, B:004, PT:028C, BT:043C, PV:111902, M:Charge 03088 12/04/2025 00:39:03 SOC:7894,60316,16540,114800,86,86,87,-21 03089 12/04/2025 00:49:03 Discharge level 014 AH, SOC: 89%, I:-10A, L:4014, l:4000, H:4017, B:003, PT:027C, BT:040C, PV:112453, M:Charge 03090 12/04/2025 00:49:03 SOC:6929,61209,14699,114800,88,88,89,-20 03091 12/04/2025 00:54:15 Charged To Full 013 AH, SOC: 90%, L:4025, H:4027, B:002, PT:027C, BT:037C, PV:112741 03092 12/04/2025 00:54:15 SOC adjusted for voltage old: 6376412uAH (soc:90%), new: 6162122uAH (soc:90%), low cell: 4025 mV 03093 12/04/2025 00:59:03 Discharge level 010 AH, SOC: 91%, I:-10A, L:4034, l:4020, H:4037, B:003, PT:027C, BT:035C, PV:113011, M:Charge 03094 12/04/2025 00:59:04 SOC:5776,62123,10599,114800,91,90,91,-20 03095 12/04/2025 01:09:03 Discharge level 008 AH, SOC: 93%, I:-10A, L:4054, l:4040, H:4057, B:003, PT:027C, BT:032C, PV:113566, M:Charge 03096 12/04/2025 01:09:04 SOC:4760,62941,8783,114800,93,92,93,-20 03097 12/04/2025 01:19:03 Discharge level 006 AH, SOC: 95%, I:-11A, L:4074, l:4060, H:4077, B:003, PT:027C, BT:031C, PV:114121, M:Charge 03098 12/04/2025 01:19:04 SOC:3622,63604,6999,114800,94,94,95,-20 03099 12/04/2025 01:29:03 Discharge level 005 AH, SOC: 97%, I:-10A, L:4094, l:4080, H:4097, B:003, PT:027C, BT:032C, PV:114678, M:Charge 03100 12/04/2025 01:29:04 SOC:2441,64238,5203,114800,96,96,97,-20 03101 12/04/2025 02:11:53 DEBUG: CAN Link Is Down 03102 12/04/2025 02:11:57 Contactor was Opened Pack V: 116090mV, Switched V: 116105mV, Prechg Pct: 100%, Dischg Cur: 545mA 03103 12/04/2025 02:11:57 DEBUG: CAN Link Is Up 03104 12/04/2025 02:12:00 System Turned Off 03105 12/04/2025 02:12:00 DEBUG: CAN Link Is Down 03106 12/04/2025 02:12:01 DEBUG: Entered Idle State 03107 12/04/2025 02:12:08 Discharge level 000 AH, SOC:100%, I: 0A, L:4148, l:4146, H:4151, B:003, PT:026C, BT:035C, PV:116072, M:Idle 03108 12/04/2025 02:12:08 SOC:0,65440,0,114800,100,100,100,-4 03109 12/04/2025 02:12:27 Voltage Across Contactor: 103161mV (Okay) 03110 12/04/2025 09:25:20 System Turned On 03111 12/04/2025 09:25:20 Rev:45,Build:2023-05-20_045619 958 banka 03112 12/04/2025 09:25:20 Pack:2019_monolith,Numbricks:4 03113 12/04/2025 09:25:21 DEBUG: Entered Charging State 03114 12/04/2025 09:25:21 DEBUG: CAN NOT Receiving Syncs 03115 12/04/2025 09:25:21 DEBUG: Entered Running State 03116 12/04/2025 09:25:21 DEBUG: CAN Link Is Up 03117 12/04/2025 09:25:21 DEBUG: Resetting CAN0 due to error passive mode 03118 12/04/2025 09:25:22 Discharge level 000 AH, SOC:100%, I: 0A, L:4123, l:4120, H:4126, B:003, PT:018C, BT:023C, PV:115502, M:Bike On 03119 12/04/2025 09:25:22 SOC:0,65440,0,114800,100,100,100,-3 03120 12/04/2025 09:25:25 DEBUG: CAN Receiving Syncs 03121 12/04/2025 09:25:30 Contactor drive turned on Pack V: 115480mV, Switched V: 102439mV, Duty Cycle: 34% 03122 12/04/2025 09:25:30 Contactor was Closed Pack V: 115480mV, Switched V: 102439mV, Prechg Pct: 89%, Dischg Cur: 545mA 03123 12/04/2025 09:26:22 Discharge level 000 AH, SOC:100%, I: 1A, L:4121, l:4121, H:4123, B:002, PT:018C, BT:023C, PV:115410, M:Bike On 03124 12/04/2025 09:26:22 SOC:12,65434,13,114800,100,100,100,0 03125 12/04/2025 09:27:22 Discharge level 000 AH, SOC:100%, I: 45A, L:4033, l:4069, H:4048, B:015, PT:018C, BT:023C, PV:113147, M:Bike On 03126 12/04/2025 09:27:22 SOC:133,65234,134,114800,100,95,100,36 03127 12/04/2025 09:28:22 Discharge level 000 AH, SOC: 99%, I: 50A, L:4018, l:4082, H:4034, B:016, PT:018C, BT:023C, PV:112739, M:Bike On 03128 12/04/2025 09:28:22 SOC:746,64229,746,114800,100,96,99,65 03129 12/04/2025 09:29:22 Discharge level 001 AH, SOC: 99%, I: 19A, L:4067, l:4097, H:4077, B:010, PT:018C, BT:023C, PV:114044, M:Bike On 03130 12/04/2025 09:29:22 SOC:1058,63605,1076,114800,100,97,99,30 03131 12/04/2025 09:30:22 Discharge level 001 AH, SOC: 98%, I: 0A, L:4065, l:4093, H:4074, B:009, PT:018C, BT:022C, PV:113973, M:Bike On 03132 12/04/2025 09:30:22 SOC:1526,62806,1556,114800,99,97,98,28 03133 12/04/2025 09:31:22 Discharge level 002 AH, SOC: 97%, I:-32A, L:4081, l:4099, H:4091, B:010, PT:018C, BT:022C, PV:114415, M:Bike On 03134 12/04/2025 09:31:22 SOC:1941,62051,2016,114800,99,97,97,19 03135 12/04/2025 09:32:22 Discharge level 002 AH, SOC: 97%, I: 1A, L:4016, l:4051, H:4031, B:015, PT:018C, BT:023C, PV:112710, M:Bike On 03136 12/04/2025 09:32:22 SOC:2408,61332,2508,114800,98,93,97,35 03137 12/04/2025 09:33:22 Discharge level 002 AH, SOC: 97%, I: 41A, L:3991, l:4030, H:4011, B:020, PT:018C, BT:023C, PV:112049, M:Bike On 03138 12/04/2025 09:33:22 SOC:2335,61106,2524,114800,98,91,97,40 03139 12/04/2025 09:34:22 Discharge level 002 AH, SOC: 96%, I: 1A, L:4058, l:4078, H:4066, B:008, PT:018C, BT:022C, PV:113769, M:Bike On 03140 12/04/2025 09:34:22 SOC:2664,60589,2871,114800,98,95,96,21 03141 12/04/2025 09:35:22 Discharge level 003 AH, SOC: 96%, I: 19A, L:4016, l:4044, H:4031, B:015, PT:018C, BT:021C, PV:112702, M:Bike On 03142 12/04/2025 09:35:22 SOC:2813,60359,3022,114800,98,92,96,29 03143 12/04/2025 09:36:22 Discharge level 003 AH, SOC: 96%, I: 46A, L:3977, l:4017, H:3998, B:021, PT:018C, BT:021C, PV:111684, M:Bike On 03144 12/04/2025 09:36:22 SOC:2880,60186,3113,114800,98,90,96,41 03145 12/04/2025 09:37:22 Discharge level 003 AH, SOC: 95%, I: 1A, L:4053, l:4068, H:4062, B:009, PT:018C, BT:021C, PV:113642, M:Bike On 03146 12/04/2025 09:37:22 SOC:3157,59788,3413,114800,98,94,95,15 03147 12/04/2025 09:38:17 Contactor was Opened Pack V: 113827mV, Switched V: 113821mV, Prechg Pct: 100%, Dischg Cur: 909mA 03148 12/04/2025 09:38:18 System Turned Off 03149 12/04/2025 09:38:19 DEBUG: CAN Link Is Down 03150 12/04/2025 09:38:19 DEBUG: Entered Idle State 03151 12/04/2025 09:38:24 Current Sensor Zeroed old: 2504mV, new: 2504mV, corrfact: 252 03152 12/04/2025 09:38:26 Discharge level 003 AH, SOC: 95%, I: 0A, L:4063, l:4072, H:4070, B:007, PT:018C, BT:021C, PV:113833, M:Idle 03153 12/04/2025 09:38:26 SOC:3228,59730,3485,114800,97,95,95,9 03154 12/04/2025 09:38:47 Voltage Across Contactor: 100507mV (Okay) 03155 12/04/2025 10:58:00 System Turned On 03156 12/04/2025 10:58:00 Rev:45,Build:2023-05-20_045619 958 banka 03157 12/04/2025 10:58:00 Pack:2019_monolith,Numbricks:4 03158 12/04/2025 10:58:00 DEBUG: Entered Running State 03159 12/04/2025 10:58:00 DEBUG: CAN NOT Receiving Syncs 03160 12/04/2025 10:58:00 DEBUG: CAN Link Is Up 03161 12/04/2025 10:58:01 DEBUG: Resetting CAN0 due to error passive mode 03162 12/04/2025 10:58:01 Discharge level 003 AH, SOC: 95%, I: 0A, L:4081, l:4091, H:4085, B:004, PT:017C, BT:035C, PV:114357, M:Bike On 03163 12/04/2025 10:58:01 SOC:3226,59730,3485,114800,97,97,95,9 03164 12/04/2025 10:58:04 DEBUG: CAN Receiving Syncs 03165 12/04/2025 10:58:05 Contactor drive turned on Pack V: 114304mV, Switched V: 99918mV, Duty Cycle: 35% 03166 12/04/2025 10:58:05 Contactor was Closed Pack V: 114304mV, Switched V: 99918mV, Prechg Pct: 87%, Dischg Cur: 1091mA 03167 12/04/2025 10:59:01 Discharge level 003 AH, SOC: 95%, I: 1A, L:4080, l:4087, H:4083, B:003, PT:017C, BT:031C, PV:114297, M:Bike On 03168 12/04/2025 10:59:01 SOC:3233,59948,3505,114800,97,96,95,6 03169 12/04/2025 11:00:01 Discharge level 003 AH, SOC: 95%, I: 1A, L:4076, l:4082, H:4080, B:004, PT:017C, BT:030C, PV:114211, M:Bike On 03170 12/04/2025 11:00:01 SOC:3273,60079,3564,114800,97,96,95,6 03171 12/04/2025 11:01:01 Discharge level 003 AH, SOC: 95%, I: 1A, L:4067, l:4079, H:4072, B:005, PT:017C, BT:028C, PV:113977, M:Bike On 03172 12/04/2025 11:01:01 SOC:3378,60076,3686,114800,97,95,95,11 03173 12/04/2025 11:02:01 Discharge level 003 AH, SOC: 95%, I: 1A, L:4062, l:4079, H:4067, B:005, PT:017C, BT:027C, PV:113829, M:Bike On 03174 12/04/2025 11:02:01 SOC:3512,59915,3861,114800,97,95,95,15 03175 12/04/2025 11:03:01 Discharge level 004 AH, SOC: 94%, I: 1A, L:4004, l:4039, H:4020, B:016, PT:017C, BT:026C, PV:112378, M:Bike On 03176 12/04/2025 11:03:01 SOC:3813,59452,4215,114800,97,92,94,32 03177 12/04/2025 11:04:01 Discharge level 004 AH, SOC: 93%, I:-34A, L:4030, l:4088, H:4043, B:013, PT:017C, BT:026C, PV:113033, M:Bike On 03178 12/04/2025 11:04:01 SOC:4458,58709,4910,114800,96,96,93,53 03179 12/04/2025 11:04:01 Discharge cutback 89% 03180 12/04/2025 11:04:01 769A 03181 12/04/2025 11:05:01 Discharge level 005 AH, SOC: 92%, I: 50A, L:3920, l:3992, H:3945, B:025, PT:017C, BT:024C, PV:110195, M:Bike On 03182 12/04/2025 11:05:01 SOC:5093,57988,5641,114800,96,87,92,65 03183 12/04/2025 11:06:01 Discharge level 006 AH, SOC: 91%, I: 1A, L:3955, l:3993, H:3977, B:022, PT:017C, BT:023C, PV:111095, M:Bike On 03184 12/04/2025 11:06:01 SOC:5441,57517,6054,114800,95,87,91,34 03185 12/04/2025 11:07:01 Discharge level 006 AH, SOC: 91%, I: 1A, L:4022, l:4039, H:4031, B:009, PT:017C, BT:023C, PV:112778, M:Bike On 03186 12/04/2025 11:07:01 SOC:5488,57520,6132,114800,95,92,91,15 03187 12/04/2025 11:07:43 Contactor was Opened Pack V: 112934mV, Switched V: 112915mV, Prechg Pct: 100%, Dischg Cur: 818mA 03188 12/04/2025 11:07:44 System Turned Off 03189 12/04/2025 11:07:45 DEBUG: CAN Link Is Down 03190 12/04/2025 11:07:45 DEBUG: Entered Idle State 03191 12/04/2025 11:07:51 Current Sensor Zeroed old: 2504mV, new: 2503mV, corrfact: 253 03192 12/04/2025 11:07:52 Discharge level 006 AH, SOC: 91%, I: 0A, L:4030, l:4041, H:4038, B:008, PT:017C, BT:023C, PV:112894, M:Idle 03193 12/04/2025 11:07:52 SOC:5496,57619,6150,114800,95,92,91,9 03194 12/04/2025 11:07:55 System Turned On 03195 12/04/2025 11:07:55 Rev:45,Build:2023-05-20_045619 958 banka 03196 12/04/2025 11:07:55 Pack:2019_monolith,Numbricks:4 03197 12/04/2025 11:07:55 DEBUG: Entered Running State 03198 12/04/2025 11:07:55 DEBUG: CAN NOT Receiving Syncs 03199 12/04/2025 11:07:55 DEBUG: CAN Link Is Up 03200 12/04/2025 11:07:56 DEBUG: Resetting CAN0 due to error passive mode 03201 12/04/2025 11:07:56 Discharge level 006 AH, SOC: 91%, I: 0A, L:4030, l:4041, H:4038, B:008, PT:017C, BT:023C, PV:112994, M:Bike On 03202 12/04/2025 11:07:56 SOC:5495,57619,6150,114800,95,92,91,10 03203 12/04/2025 11:07:59 DEBUG: CAN Receiving Syncs 03204 12/04/2025 11:07:59 Contactor drive turned on Pack V: 112981mV, Switched V: 99721mV, Duty Cycle: 35% 03205 12/04/2025 11:07:59 Contactor was Closed Pack V: 112981mV, Switched V: 99721mV, Prechg Pct: 88%, Dischg Cur: 545mA 03206 12/04/2025 11:08:01 DEBUG: Entered Charging State 03207 12/04/2025 11:08:01 DEBUG: CAN NOT Receiving Syncs 03208 12/04/2025 11:08:02 Discharge level 006 AH, SOC: 91%, I: 0A, L:4030, l:4040, H:4038, B:008, PT:017C, BT:023C, PV:112998, M:Charge 03209 12/04/2025 11:08:03 SOC:5487,57620,6151,114800,95,92,91,9 03210 12/04/2025 11:08:03 DEBUG: CAN Receiving Syncs 03211 12/04/2025 11:18:03 Discharge level 004 AH, SOC: 97%, I:-10A, L:4108, l:4087, H:4115, B:007, PT:017C, BT:032C, PV:115135, M:Charge 03212 12/04/2025 11:18:03 SOC:2029,55967,4373,114800,97,97,97,-19 03213 12/04/2025 11:28:03 Discharge level 002 AH, SOC:100%, I:-10A, L:4136, l:4115, H:4144, B:008, PT:017C, BT:036C, PV:115915, M:Charge 03214 12/04/2025 11:28:03 SOC:332,56029,2632,114800,98,99,100,-19 03215 12/04/2025 11:38:03 Discharge level 000 AH, SOC:100%, I: -9A, L:4155, l:4137, H:4163, B:008, PT:017C, BT:036C, PV:116454, M:Charge 03216 12/04/2025 11:38:03 SOC:0,56085,990,114800,100,100,100,-17 03217 12/04/2025 11:43:56 DEBUG: Entered Standby State 03218 12/04/2025 11:43:56 DEBUG: CAN NOT Receiving Syncs 03219 12/04/2025 11:43:57 System Turned Off 03220 12/04/2025 11:43:58 DEBUG: CAN Link Is Down 03221 12/04/2025 11:43:58 DEBUG: Entered Idle State 03222 12/04/2025 11:43:58 Contactor was Opened Pack V: 115989mV, Switched V: 115908mV, Prechg Pct: 100%, Dischg Cur: 363mA 03223 12/04/2025 11:44:01 System Turned On 03224 12/04/2025 11:44:01 Rev:45,Build:2023-05-20_045619 958 banka 03225 12/04/2025 11:44:01 Pack:2019_monolith,Numbricks:4 03226 12/04/2025 11:44:01 DEBUG: Entered Standby State 03227 12/04/2025 11:44:01 DEBUG: CAN Link Is Up 03228 12/04/2025 11:44:01 DEBUG: Entered Running State 03229 12/04/2025 11:44:02 DEBUG: Resetting CAN0 due to error passive mode 03230 12/04/2025 11:44:02 Discharge level 000 AH, SOC:100%, I: 0A, L:4139, l:4133, H:4142, B:003, PT:017C, BT:036C, PV:115947, M:Bike On 03231 12/04/2025 11:44:02 SOC:0,56085,345,114800,100,100,100,-5 03232 12/04/2025 11:44:05 DEBUG: CAN Receiving Syncs 03233 12/04/2025 11:44:05 Contactor drive turned on Pack V: 115905mV, Switched V: 102793mV, Duty Cycle: 34% 03234 12/04/2025 11:44:05 Contactor was Closed Pack V: 115905mV, Switched V: 102793mV, Prechg Pct: 89%, Dischg Cur: 545mA 03235 12/04/2025 11:45:02 Discharge level 000 AH, SOC:100%, I: 1A, L:4133, l:4132, H:4137, B:004, PT:017C, BT:033C, PV:115793, M:Bike On 03236 12/04/2025 11:45:02 SOC:12,56085,360,114800,100,100,100,-1 03237 12/04/2025 11:46:02 Discharge level 000 AH, SOC:100%, I: 0A, L:4129, l:4136, H:4131, B:002, PT:017C, BT:030C, PV:115652, M:Bike On 03238 12/04/2025 11:46:02 SOC:88,56006,437,114800,100,100,100,6 03239 12/04/2025 11:47:02 Discharge level 000 AH, SOC:100%, I: 1A, L:4062, l:4084, H:4077, B:015, PT:017C, BT:030C, PV:113940, M:Bike On 03240 12/04/2025 11:47:02 SOC:414,55540,771,114800,100,96,100,20 03241 12/04/2025 11:48:02 Discharge level 001 AH, SOC: 99%, I: 1A, L:4100, l:4116, H:4106, B:006, PT:017C, BT:029C, PV:114913, M:Bike On 03242 12/04/2025 11:48:02 SOC:652,55171,1024,114800,100,99,99,15 03243 12/04/2025 11:49:02 Discharge level 001 AH, SOC: 99%, I: 17A, L:4056, l:4077, H:4069, B:013, PT:017C, BT:028C, PV:113769, M:Bike On 03244 12/04/2025 11:49:02 SOC:669,55002,1087,114800,100,95,99,19 03245 12/04/2025 11:50:02 Discharge level 001 AH, SOC: 99%, I: 18A, L:4064, l:4085, H:4076, B:012, PT:017C, BT:027C, PV:113986, M:Bike On 03246 12/04/2025 11:50:02 SOC:659,54908,1122,114800,100,96,99,19 03247 12/04/2025 11:51:02 Discharge level 001 AH, SOC: 99%, I: 42A, L:4011, l:4055, H:4031, B:020, PT:017C, BT:026C, PV:112628, M:Bike On 03248 12/04/2025 11:51:02 SOC:883,54577,1359,114800,99,93,99,40 03249 12/04/2025 11:52:02 Discharge level 002 AH, SOC: 97%, I: 73A, L:3869, l:3989, H:3906, B:037, PT:017C, BT:025C, PV:108920, M:Bike On 03250 12/04/2025 11:52:02 SOC:1873,53461,2352,114800,98,86,97,110 03251 12/04/2025 11:53:02 Discharge level 003 AH, SOC: 94%, I:198A, L:3598, l:3838, H:3674, B:076, PT:018C, BT:025C, PV:101947, M:Bike On 03252 12/04/2025 11:53:02 SOC:3490,51893,3968,114800,97,73,94,231 03253 12/04/2025 11:54:02 Discharge level 005 AH, SOC: 90%, I:117A, L:3723, l:3909, H:3779, B:056, PT:018C, BT:025C, PV:105182, M:Bike On 03254 12/04/2025 11:54:02 SOC:5114,50613,5593,114800,96,80,90,176 03255 12/04/2025 11:55:02 Discharge level 007 AH, SOC: 86%, I: 95A, L:3717, l:3926, H:3774, B:057, PT:019C, BT:024C, PV:105070, M:Bike On 03256 12/04/2025 11:55:02 SOC:7169,49345,7650,114800,94,80,86,193 03257 12/04/2025 11:56:02 Discharge level 009 AH, SOC: 82%, I:120A, L:3655, l:3877, H:3722, B:067, PT:019C, BT:024C, PV:103538, M:Bike On 03258 12/04/2025 11:56:02 SOC:8991,48606,9473,114800,92,75,82,214 03259 12/04/2025 11:57:02 Discharge level 011 AH, SOC: 77%, I:148A, L:3608, l:3862, H:3684, B:076, PT:020C, BT:022C, PV:102410, M:Bike On 03260 12/04/2025 11:57:02 SOC:11097,48041,11581,114800,90,74,77,242 03261 12/04/2025 11:58:02 Discharge level 013 AH, SOC: 73%, I:119A, L:3648, l:3848, H:3718, B:070, PT:021C, BT:022C, PV:103490, M:Bike On 03262 12/04/2025 11:58:02 SOC:12978,47969,13466,114800,89,73,73,202 03263 12/04/2025 11:59:02 Discharge level 016 AH, SOC: 67%, I:157A, L:3531, l:3798, H:3623, B:092, PT:022C, BT:023C, PV:100668, M:Bike On 03264 12/04/2025 11:59:03 SOC:15942,47545,16437,114800,86,67,67,290 03265 12/04/2025 12:00:02 Discharge level 019 AH, SOC: 62%, I:185A, L:3474, l:3739, H:3579, B:105, PT:023C, BT:021C, PV: 99361, M:Bike On 03266 12/04/2025 12:00:03 SOC:18562,47761,19059,114800,84,61,62,309 03267 12/04/2025 12:01:03 Discharge level 021 AH, SOC: 56%, I: 4A, L:3661, l:3837, H:3721, B:060, PT:025C, BT:023C, PV:103778, M:Bike On 03268 12/04/2025 12:01:03 SOC:21216,48142,21755,114800,82,72,56,209 03269 12/04/2025 12:01:03 Discharge cutback 66% 03270 12/04/2025 12:01:03 567A 03271 12/04/2025 12:02:03 Discharge level 024 AH, SOC: 52%, I:162A, L:3489, l:3730, H:3586, B:097, PT:026C, BT:022C, PV: 99667, M:Bike On 03272 12/04/2025 12:02:03 SOC:23946,48958,24487,114800,79,59,52,300 03273 12/04/2025 12:02:03 Discharge cutback 82% 03274 12/04/2025 12:02:03 705A 03275 12/04/2025 12:03:03 Discharge level 027 AH, SOC: 47%, I:131A, L:3521, l:3720, H:3607, B:086, PT:027C, BT:022C, PV:100367, M:Bike On 03276 12/04/2025 12:03:03 SOC:26523,50030,27069,114800,77,58,47,263 03277 12/04/2025 12:03:03 Discharge cutback 81% 03278 12/04/2025 12:03:03 698A 03279 12/04/2025 12:04:03 Discharge level 029 AH, SOC: 45%, I:102A, L:3524, l:3717, H:3607, B:083, PT:028C, BT:023C, PV:100426, M:Bike On 03280 12/04/2025 12:04:03 SOC:28387,51040,29087,114800,75,58,45,268 03281 12/04/2025 12:04:03 Discharge cutback 51% 03282 12/04/2025 12:04:03 435A 03283 12/04/2025 12:05:03 Discharge level 031 AH, SOC: 43%, I: 3A, L:3626, l:3758, H:3675, B:049, PT:029C, BT:023C, PV:102605, M:Bike On 03284 12/04/2025 12:05:03 SOC:30342,52478,31082,114800,73,63,43,190 03285 12/04/2025 12:05:03 Discharge cutback 62% 03286 12/04/2025 12:05:03 530A 03287 12/04/2025 12:06:03 Discharge level 033 AH, SOC: 39%, I:181A, L:3420, l:3636, H:3521, B:101, PT:030C, BT:022C, PV: 97888, M:Bike On 03288 12/04/2025 12:06:03 SOC:33066,53398,33819,114800,71,45,39,325 03289 12/04/2025 12:06:03 Discharge cutback 53% 03290 12/04/2025 12:06:03 452A 03291 12/04/2025 12:07:03 Discharge level 035 AH, SOC: 37%, I:121A, L:3495, l:3647, H:3574, B:079, PT:030C, BT:023C, PV: 99541, M:Bike On 03292 12/04/2025 12:07:03 SOC:34717,54866,35612,114800,69,47,37,236 03293 12/04/2025 12:07:03 Discharge cutback 69% 03294 12/04/2025 12:07:03 597A 03295 12/04/2025 12:08:03 Discharge level 036 AH, SOC: 39%, I: 21A, L:3633, l:3705, H:3673, B:040, PT:031C, BT:023C, PV:102613, M:Bike On 03296 12/04/2025 12:08:03 SOC:35277,57477,36258,114800,69,57,39,112 03297 12/04/2025 12:08:03 Discharge cutback 86% 03298 12/04/2025 12:08:03 742A 03299 12/04/2025 12:09:03 Discharge level 038 AH, SOC: 37%, I:319A, L:3305, l:3529, H:3435, B:130, PT:031C, BT:024C, PV: 95267, M:Bike On 03300 12/04/2025 12:09:03 SOC:37249,58581,38286,114800,67,18,37,363 03301 12/04/2025 12:09:03 Discharge cutback 55% 03302 12/04/2025 12:09:03 476A 03303 12/04/2025 12:10:03 Discharge level 041 AH, SOC: 30%, I:214A, L:3337, l:3564, H:3453, B:116, PT:033C, BT:024C, PV: 95919, M:Bike On 03304 12/04/2025 12:10:03 SOC:40686,57433,41901,114800,64,25,30,361 03305 12/04/2025 12:10:03 Discharge cutback 47% 03306 12/04/2025 12:10:03 408A 03307 12/04/2025 12:11:03 Discharge level 042 AH, SOC: 32%, I:-24A, L:3633, l:3685, H:3662, B:029, PT:033C, BT:023C, PV:102390, M:Bike On 03308 12/04/2025 12:11:03 SOC:40786,59824,42298,114800,64,55,32,87 03309 12/04/2025 12:11:03 Discharge cutback 76% 03310 12/04/2025 12:11:03 658A 03311 12/04/2025 12:12:03 Discharge level 042 AH, SOC: 35%, I: 1A, L:3642, l:3680, H:3668, B:026, PT:033C, BT:023C, PV:102567, M:Bike On 03312 12/04/2025 12:12:03 SOC:40236,61532,42454,114800,64,54,35,64 03313 12/04/2025 12:12:03 Discharge cutback 85% 03314 12/04/2025 12:12:03 736A 03315 12/04/2025 12:12:33 Contactor was Opened Pack V: 102798mV, Switched V: 102754mV, Prechg Pct: 100%, Dischg Cur: 1546mA 03316 12/04/2025 12:12:33 System Turned Off 03317 12/04/2025 12:12:34 DEBUG: CAN Link Is Down 03318 12/04/2025 12:12:34 DEBUG: Entered Idle State 03319 12/04/2025 12:12:40 Current Sensor Zeroed old: 2504mV, new: 2506mV, corrfact: 250 03320 12/04/2025 12:12:41 Current Sensor Zeroed old: 2503mV, new: 2504mV, corrfact: 252 03321 12/04/2025 12:12:42 Discharge level 042 AH, SOC: 37%, I: 0A, L:3655, l:3682, H:3678, B:023, PT:033C, BT:023C, PV:102870, M:Idle 03322 12/04/2025 12:12:42 SOC:40233,63157,42466,114800,64,54,37,45 03323 12/04/2025 12:13:02 System Turned On 03324 12/04/2025 12:13:02 Rev:45,Build:2023-05-20_045619 958 banka 03325 12/04/2025 12:13:02 Pack:2019_monolith,Numbricks:4 03326 12/04/2025 12:13:02 DEBUG: Entered Running State 03327 12/04/2025 12:13:02 DEBUG: CAN NOT Receiving Syncs 03328 12/04/2025 12:13:03 DEBUG: CAN Link Is Up 03329 12/04/2025 12:13:03 Voltage Across Contactor: 89973mV (Okay) 03330 12/04/2025 12:13:03 DEBUG: Resetting CAN0 due to error passive mode 03331 12/04/2025 12:13:04 Discharge level 042 AH, SOC: 37%, I: 0A, L:3659, l:3686, H:3681, B:022, PT:033C, BT:025C, PV:102965, M:Bike On 03332 12/04/2025 12:13:04 SOC:40220,63157,42466,114800,64,55,37,45 03333 12/04/2025 12:13:07 DEBUG: CAN Receiving Syncs 03334 12/04/2025 12:13:07 Contactor drive turned on Pack V: 102973mV, Switched V: 90584mV, Duty Cycle: 39% 03335 12/04/2025 12:13:07 Contactor was Closed Pack V: 102973mV, Switched V: 90584mV, Prechg Pct: 88%, Dischg Cur: 636mA 03336 12/04/2025 12:13:09 DEBUG: Entered Charging State 03337 12/04/2025 12:13:09 DEBUG: CAN NOT Receiving Syncs 03338 12/04/2025 12:13:10 Discharge level 042 AH, SOC: 37%, I: 0A, L:3661, l:3686, H:3682, B:021, PT:033C, BT:024C, PV:102987, M:Charge 03339 12/04/2025 12:13:10 SOC:40137,63203,42467,114800,64,55,37,43 03340 12/04/2025 12:13:10 DEBUG: CAN Receiving Syncs 03341 12/04/2025 12:23:10 Discharge level 040 AH, SOC: 54%, I:825A, L:3727, l:13620, H:3735, B:008, PT:033C, BT:034C, PV:1764877998, M:None 03342 12/04/2025 13:03:18 Discharge level 032 AH, SOC: 71%, I:-11A, L:3816, l:3801, H:3826, B:010, PT:031C, BT:040C, PV:106947, M:Charge 03343 12/04/2025 13:03:18 Discharge level 032 AH, SOC: 71%, I:-11A, L:3816, l:3801, H:3826, B:010, PT:031C, BT:040C, PV:106947, M:Charge 03344 12/04/2025 13:03:18 SOC:13929,47011,32651,114800,72,69,71,-21 03345 12/04/2025 13:13:18 Discharge level 030 AH, SOC: 73%, I:-11A, L:3838, l:3823, H:3848, B:010, PT:031C, BT:039C, PV:107585, M:Charge 03346 12/04/2025 13:13:18 SOC:13236,48238,30748,114800,74,72,73,-21 03347 12/04/2025 13:23:18 Discharge level 028 AH, SOC: 75%, I:-11A, L:3863, l:3848, H:3872, B:009, PT:031C, BT:039C, PV:108249, M:Charge 03348 12/04/2025 13:23:18 SOC:12397,49290,28873,114800,75,74,75,-21 03349 12/04/2025 13:33:18 Discharge level 027 AH, SOC: 78%, I:-10A, L:3887, l:3873, H:3893, B:006, PT:030C, BT:040C, PV:108915, M:Charge 03350 12/04/2025 13:33:18 SOC:11475,50242,27015,114800,77,77,78,-20 03351 12/04/2025 13:43:18 Discharge level 025 AH, SOC: 80%, I:-10A, L:3911, l:3896, H:3916, B:005, PT:030C, BT:044C, PV:109571, M:Charge 03352 12/04/2025 13:43:18 SOC:10500,51141,25158,114800,79,79,80,-20 03353 12/04/2025 13:53:18 Discharge level 023 AH, SOC: 82%, I:-11A, L:3932, l:3917, H:3937, B:005, PT:029C, BT:043C, PV:110175, M:Charge 03354 12/04/2025 13:53:18 SOC:9685,52205,23295,114800,80,81,82,-21 03355 12/04/2025 14:03:26 Discharge level 021 AH, SOC: 84%, I:-10A, L:3952, l:3937, H:3957, B:005, PT:029C, BT:043C, PV:110736, M:Charge 03356 12/04/2025 14:03:26 SOC:8918,53304,21449,114800,82,83,84,-20 03357 12/04/2025 14:13:26 Discharge level 019 AH, SOC: 86%, I:-10A, L:3972, l:3957, H:3976, B:004, PT:028C, BT:042C, PV:111293, M:Charge 03358 12/04/2025 14:13:26 SOC:8140,54351,19642,114800,83,84,86,-20 03359 12/04/2025 14:23:26 Discharge level 017 AH, SOC: 87%, I:-10A, L:3992, l:3977, H:3995, B:003, PT:028C, BT:039C, PV:111820, M:Charge 03360 12/04/2025 14:23:26 SOC:7284,55311,17843,114800,85,86,87,-20 03361 12/04/2025 14:33:26 Discharge level 016 AH, SOC: 89%, I:-10A, L:4012, l:3997, H:4015, B:003, PT:027C, BT:033C, PV:112378, M:Charge 03362 12/04/2025 14:33:26 SOC:6403,56250,16041,114800,87,88,89,-20 03363 12/04/2025 14:40:27 Charged To Full 014 AH, SOC: 90%, L:4026, H:4029, B:003, PT:027C, BT:033C, PV:112763 03364 12/04/2025 14:40:27 SOC adjusted for voltage old: 5790071uAH (soc:90%), new: 5121257uAH (soc:91%), low cell: 4026 mV 03365 12/04/2025 14:43:26 Discharge level 009 AH, SOC: 91%, I:-10A, L:4031, l:4016, H:4034, B:003, PT:027C, BT:031C, PV:112914, M:Charge 03366 12/04/2025 14:43:26 SOC:5213,57531,9801,114800,92,90,91,-20 03367 12/04/2025 14:53:26 Discharge level 008 AH, SOC: 93%, I:-10A, L:4051, l:4036, H:4055, B:004, PT:026C, BT:034C, PV:113466, M:Charge 03368 12/04/2025 14:53:26 SOC:4674,58774,8037,114800,93,92,93,-19 03369 12/04/2025 15:03:26 Discharge level 006 AH, SOC: 94%, I:-10A, L:4070, l:4056, H:4074, B:004, PT:026C, BT:035C, PV:114017, M:Charge 03370 12/04/2025 15:03:26 SOC:3686,59552,6289,114800,95,93,94,-19 03371 12/04/2025 15:13:34 Discharge level 004 AH, SOC: 96%, I:-10A, L:4090, l:4076, H:4095, B:005, PT:026C, BT:037C, PV:114576, M:Charge 03372 12/04/2025 15:13:34 SOC:2560,60205,4528,114800,97,95,96,-19 03373 12/04/2025 15:56:45 DEBUG: CAN Link Is Down 03374 12/04/2025 15:56:49 Contactor was Opened Pack V: 115852mV, Switched V: 116066mV, Prechg Pct: 100%, Dischg Cur: 454mA 03375 12/04/2025 15:56:49 DEBUG: CAN Link Is Up 03376 12/04/2025 15:56:51 System Turned Off 03377 12/04/2025 15:56:52 DEBUG: CAN Link Is Down 03378 12/04/2025 15:56:52 DEBUG: Entered Idle State 03379 12/04/2025 15:56:58 Current Sensor Zeroed old: 2506mV, new: 2507mV, corrfact: 249 03380 12/04/2025 15:57:00 Discharge level 000 AH, SOC:100%, I: 0A, L:4146, l:4143, H:4150, B:004, PT:024C, BT:038C, PV:115964, M:Idle 03381 12/04/2025 15:57:00 SOC:0,61616,0,114800,100,100,100,-4 03382 12/04/2025 15:57:19 Voltage Across Contactor: 103062mV (Okay) 03383 12/04/2025 21:51:00 System Turned On 03384 12/04/2025 21:51:00 Rev:45,Build:2023-05-20_045619 958 banka 03385 12/04/2025 21:51:00 Pack:2019_monolith,Numbricks:4 03386 12/04/2025 21:51:00 DEBUG: Entered Charging State 03387 12/04/2025 21:51:00 DEBUG: CAN NOT Receiving Syncs 03388 12/04/2025 21:51:00 DEBUG: Entered Running State 03389 12/04/2025 21:51:00 DEBUG: CAN Link Is Up 03390 12/04/2025 21:51:01 DEBUG: Resetting CAN0 due to error passive mode 03391 12/04/2025 21:51:01 Discharge level 000 AH, SOC:100%, I: 0A, L:4121, l:4116, H:4123, B:002, PT:014C, BT:019C, PV:115433, M:Bike On 03392 12/04/2025 21:51:01 SOC:0,61616,0,114800,100,99,100,-4 03393 12/04/2025 21:51:04 DEBUG: CAN Receiving Syncs 03394 12/04/2025 21:51:04 Contactor drive turned on Pack V: 115364mV, Switched V: 100982mV, Duty Cycle: 34% 03395 12/04/2025 21:51:04 Contactor was Closed Pack V: 115364mV, Switched V: 100982mV, Prechg Pct: 88%, Dischg Cur: 636mA 03396 12/04/2025 21:52:01 Discharge level 000 AH, SOC:100%, I: 1A, L:4118, l:4118, H:4120, B:002, PT:014C, BT:019C, PV:115350, M:Bike On 03397 12/04/2025 21:52:01 SOC:35,61519,10,114800,100,99,100,0 03398 12/04/2025 21:53:01 Discharge level 000 AH, SOC:100%, I: 1A, L:4118, l:4118, H:4120, B:002, PT:014C, BT:019C, PV:115343, M:Bike On 03399 12/04/2025 21:53:01 SOC:65,61412,23,114800,100,99,100,0 03400 12/04/2025 21:54:01 Discharge level 000 AH, SOC:100%, I: 0A, L:4118, l:4118, H:4120, B:002, PT:014C, BT:019C, PV:115343, M:Bike On 03401 12/04/2025 21:54:01 SOC:93,61306,37,114800,100,99,100,0 03402 12/04/2025 21:55:01 Discharge level 000 AH, SOC:100%, I: 16A, L:4088, l:4106, H:4094, B:006, PT:014C, BT:019C, PV:114556, M:Bike On 03403 12/04/2025 21:55:01 SOC:194,61121,111,114800,100,98,100,14 03404 12/04/2025 21:56:01 Discharge level 000 AH, SOC:100%, I: 1A, L:3966, l:3988, H:3990, B:024, PT:014C, BT:019C, PV:111448, M:Bike On 03405 12/04/2025 21:56:01 SOC:478,60674,359,114800,100,87,100,18 03406 12/04/2025 21:57:01 Discharge level 000 AH, SOC: 99%, I: 0A, L:4081, l:4097, H:4088, B:007, PT:014C, BT:019C, PV:114375, M:Bike On 03407 12/04/2025 21:57:01 SOC:788,60153,653,114800,100,97,99,13 03408 12/04/2025 21:58:01 Discharge level 001 AH, SOC: 97%, I: 85A, L:3828, l:3954, H:3871, B:043, PT:014C, BT:019C, PV:107837, M:Bike On 03409 12/04/2025 21:58:01 SOC:1799,58552,1653,114800,99,84,97,105 03410 12/04/2025 21:59:01 Discharge level 002 AH, SOC: 95%, I: 1A, L:4017, l:4079, H:4029, B:012, PT:015C, BT:019C, PV:112672, M:Bike On 03411 12/04/2025 21:59:01 SOC:2884,57076,2736,114800,98,96,95,52 03412 12/04/2025 22:00:01 Discharge level 003 AH, SOC: 95%, I: 0A, L:3974, l:4025, H:3995, B:021, PT:015C, BT:018C, PV:111616, M:Bike On 03413 12/04/2025 22:00:01 SOC:3203,56465,3088,114800,98,90,95,43 03414 12/04/2025 22:01:01 Discharge level 003 AH, SOC: 94%, I: 25A, L:3983, l:4043, H:4001, B:018, PT:015C, BT:018C, PV:111826, M:Bike On 03415 12/04/2025 22:01:01 SOC:3672,55807,3559,114800,97,92,94,50 03416 12/04/2025 22:02:01 Discharge level 004 AH, SOC: 93%, I: 0A, L:3980, l:4041, H:3999, B:019, PT:015C, BT:020C, PV:111758, M:Bike On 03417 12/04/2025 22:02:01 SOC:4094,55280,4000,114800,97,92,93,53 03418 12/04/2025 22:03:01 Discharge level 005 AH, SOC: 91%, I: 0A, L:4017, l:4090, H:4028, B:011, PT:016C, BT:020C, PV:112663, M:Bike On 03419 12/04/2025 22:03:01 SOC:5162,54266,5135,114800,96,97,91,63 03420 12/04/2025 22:04:01 Discharge level 007 AH, SOC: 87%, I:175A, L:3631, l:3950, H:3696, B:065, PT:017C, BT:019C, PV:102690, M:Bike On 03421 12/04/2025 22:04:01 SOC:7175,52669,7154,114800,94,82,87,267 03422 12/04/2025 22:04:01 Discharge cutback 72% 03423 12/04/2025 22:04:01 621A 03424 12/04/2025 22:05:01 Discharge level 008 AH, SOC: 83%, I: 1A, L:3892, l:4005, H:3913, B:021, PT:018C, BT:019C, PV:109368, M:Bike On 03425 12/04/2025 22:05:01 SOC:8900,51798,8934,114800,93,88,83,97 03426 12/04/2025 22:06:01 Discharge level 010 AH, SOC: 81%, I:244A, L:3459, l:3784, H:3552, B:093, PT:018C, BT:019C, PV: 98384, M:Bike On 03427 12/04/2025 22:06:01 SOC:10136,51429,10194,114800,92,65,81,294 03428 12/04/2025 22:07:01 Discharge level 012 AH, SOC: 76%, I:128A, L:3599, l:3851, H:3668, B:069, PT:020C, BT:018C, PV:101997, M:Bike On 03429 12/04/2025 22:07:01 SOC:12581,50724,12652,114800,89,73,76,240 03430 12/04/2025 22:07:01 Discharge cutback 89% 03431 12/04/2025 22:07:01 766A 03432 12/04/2025 22:08:01 Discharge level 014 AH, SOC: 72%, I: 70A, L:3703, l:3869, H:3756, B:053, PT:021C, BT:020C, PV:104677, M:Bike On 03433 12/04/2025 22:08:01 SOC:14325,50619,14463,114800,88,75,72,168 03434 12/04/2025 22:09:01 Discharge level 017 AH, SOC: 67%, I:147A, L:3538, l:3787, H:3620, B:082, PT:022C, BT:019C, PV:100621, M:Bike On 03435 12/04/2025 22:09:01 SOC:16966,50326,17124,114800,86,66,67,270 03436 12/04/2025 22:09:01 Discharge cutback 89% 03437 12/04/2025 22:09:01 766A 03438 12/04/2025 22:10:01 Discharge level 018 AH, SOC: 64%, I: 80A, L:3670, l:3829, H:3726, B:056, PT:023C, BT:020C, PV:103866, M:Bike On 03439 12/04/2025 22:10:01 SOC:18460,50860,18690,114800,84,71,64,173 03440 12/04/2025 22:11:01 Discharge level 020 AH, SOC: 62%, I:117A, L:3590, l:3767, H:3665, B:075, PT:024C, BT:020C, PV:101997, M:Bike On 03441 12/04/2025 22:11:01 SOC:20003,51685,20248,114800,83,64,62,207 03442 12/04/2025 22:12:01 Discharge level 022 AH, SOC: 57%, I:232A, L:3431, l:3721, H:3536, B:105, PT:024C, BT:020C, PV: 98128, M:Bike On 03443 12/04/2025 22:12:01 SOC:22566,51880,22831,114800,81,59,57,355 03444 12/04/2025 22:12:01 Discharge cutback 58% 03445 12/04/2025 22:12:01 496A 03446 12/04/2025 22:13:01 Discharge level 026 AH, SOC: 51%, I: 1A, L:3637, l:3784, H:3689, B:052, PT:026C, BT:020C, PV:102909, M:Bike On 03447 12/04/2025 22:13:01 SOC:25688,51827,26001,114800,78,66,51,192 03448 12/04/2025 22:13:01 Discharge cutback 61% 03449 12/04/2025 22:13:01 526A 03450 12/04/2025 22:14:01 Discharge level 027 AH, SOC: 49%, I: 94A, L:3581, l:3731, H:3645, B:064, PT:027C, BT:020C, PV:101583, M:Bike On 03451 12/04/2025 22:14:01 SOC:27109,52900,27601,114800,76,60,49,204 03452 12/04/2025 22:14:01 Discharge cutback 84% 03453 12/04/2025 22:14:01 725A 03454 12/04/2025 22:15:01 Discharge level 029 AH, SOC: 47%, I: 75A, L:3587, l:3720, H:3646, B:059, PT:028C, BT:021C, PV:101652, M:Bike On 03455 12/04/2025 22:15:01 SOC:28931,53889,29493,114800,75,59,47,190 03456 12/04/2025 22:15:01 Discharge cutback 80% 03457 12/04/2025 22:15:01 688A 03458 12/04/2025 22:16:01 Discharge level 031 AH, SOC: 45%, I:127A, L:3522, l:3679, H:3597, B:075, PT:028C, BT:021C, PV:100170, M:Bike On 03459 12/04/2025 22:16:01 SOC:30370,55202,31026,114800,73,53,45,225 03460 12/04/2025 22:16:01 Discharge cutback 81% 03461 12/04/2025 22:16:01 698A 03462 12/04/2025 22:17:01 Discharge level 033 AH, SOC: 42%, I: 99A, L:3521, l:3671, H:3590, B:069, PT:029C, BT:021C, PV:100036, M:Bike On 03463 12/04/2025 22:17:01 SOC:32840,55796,33534,114800,71,51,42,225 03464 12/04/2025 22:17:01 Discharge cutback 66% 03465 12/04/2025 22:17:01 570A 03466 12/04/2025 22:18:01 Discharge level 036 AH, SOC: 36%, I: 1A, L:3595, l:3700, H:3639, B:044, PT:030C, BT:022C, PV:101600, M:Bike On 03467 12/04/2025 22:18:01 SOC:35805,55604,36573,114800,69,56,36,164 03468 12/04/2025 22:18:01 Discharge cutback 61% 03469 12/04/2025 22:18:01 526A 03470 12/04/2025 22:19:01 Discharge level 038 AH, SOC: 34%, I:333A, L:3259, l:3515, H:3396, B:137, PT:031C, BT:022C, PV: 94094, M:Bike On 03471 12/04/2025 22:19:01 SOC:37831,56474,38762,114800,67,14,34,411 03472 12/04/2025 22:19:01 Discharge cutback 48% 03473 12/04/2025 22:19:02 415A 03474 12/04/2025 22:20:01 Discharge level 040 AH, SOC: 33%, I: 0A, L:3600, l:3683, H:3637, B:037, PT:032C, BT:022C, PV:101599, M:Bike On 03475 12/04/2025 22:20:01 SOC:38586,56989,40160,114800,66,54,33,134 03476 12/04/2025 22:20:01 Discharge cutback 66% 03477 12/04/2025 22:20:02 567A 03478 12/04/2025 22:21:01 Discharge level 040 AH, SOC: 34%, I: 84A, L:3547, l:3639, H:3599, B:052, PT:032C, BT:023C, PV:100431, M:Bike On 03479 12/04/2025 22:21:01 SOC:38546,57623,40977,114800,65,47,34,154 03480 12/04/2025 22:21:01 Discharge cutback 77% 03481 12/04/2025 22:21:02 661A 03482 12/04/2025 22:22:01 Discharge level 041 AH, SOC: 35%, I: 50A, L:3589, l:3653, H:3628, B:039, PT:032C, BT:024C, PV:101343, M:Bike On 03483 12/04/2025 22:22:01 SOC:38576,59072,41528,114800,64,50,35,107 03484 12/04/2025 22:22:02 Discharge cutback 83% 03485 12/04/2025 22:22:02 712A 03486 12/04/2025 22:23:01 Discharge level 041 AH, SOC: 37%, I: 1A, L:3643, l:3676, H:3668, B:025, PT:032C, BT:023C, PV:102568, M:Bike On 03487 12/04/2025 22:23:01 SOC:38239,60209,41858,114800,64,53,37,56 03488 12/04/2025 22:23:02 Discharge cutback 86% 03489 12/04/2025 22:23:02 739A 03490 12/04/2025 22:24:01 Discharge level 041 AH, SOC: 39%, I: 0A, L:3659, l:3679, H:3679, B:020, PT:032C, BT:024C, PV:102909, M:Bike On 03491 12/04/2025 22:24:01 SOC:37766,61594,41874,114800,64,54,39,35 03492 12/04/2025 22:24:19 Contactor was Opened Pack V: 102962mV, Switched V: 102912mV, Prechg Pct: 100%, Dischg Cur: 909mA 03493 12/04/2025 22:24:20 System Turned Off 03494 12/04/2025 22:24:20 DEBUG: CAN Link Is Down 03495 12/04/2025 22:24:20 DEBUG: Entered Idle State 03496 12/04/2025 22:24:25 System Turned On 03497 12/04/2025 22:24:25 Rev:45,Build:2023-05-20_045619 958 banka 03498 12/04/2025 22:24:25 Pack:2019_monolith,Numbricks:4 03499 12/04/2025 22:24:25 DEBUG: Entered Running State 03500 12/04/2025 22:24:25 DEBUG: CAN NOT Receiving Syncs 03501 12/04/2025 22:24:25 DEBUG: CAN Link Is Up 03502 12/04/2025 22:24:26 DEBUG: Resetting CAN0 due to error passive mode 03503 12/04/2025 22:24:29 DEBUG: CAN Receiving Syncs 03504 12/04/2025 22:24:29 Contactor drive turned on Pack V: 103001mV, Switched V: 90899mV, Duty Cycle: 39% 03505 12/04/2025 22:24:29 Contactor was Closed Pack V: 103001mV, Switched V: 90899mV, Prechg Pct: 88%, Dischg Cur: 363mA 03506 12/04/2025 22:25:01 Discharge level 041 AH, SOC: 41%, I: 0A, L:3666, l:3681, H:3685, B:019, PT:032C, BT:024C, PV:103075, M:Bike On 03507 12/04/2025 22:25:02 SOC:37072,61982,41878,114800,64,54,41,25 03508 12/04/2025 22:25:03 DEBUG: Entered Charging State 03509 12/04/2025 22:25:03 DEBUG: CAN NOT Receiving Syncs 03510 12/04/2025 22:25:04 Discharge level 041 AH, SOC: 41%, I: 0A, L:3667, l:3681, H:3685, B:018, PT:032C, BT:024C, PV:103077, M:Charge 03511 12/04/2025 22:25:04 SOC:37049,61982,41878,114800,64,55,41,25 03512 12/04/2025 22:25:05 DEBUG: CAN Receiving Syncs 03513 12/04/2025 22:35:04 Discharge level 039 AH, SOC: 55%, I:-11A, L:3724, l:3712, H:3732, B:008, PT:032C, BT:034C, PV:104426, M:Charge 03514 12/04/2025 22:35:04 SOC:22736,49756,39903,114800,66,59,55,-20 03515 12/04/2025 22:45:04 Discharge level 037 AH, SOC: 62%, I:-12A, L:3748, l:3734, H:3753, B:005, PT:032C, BT:035C, PV:105014, M:Charge 03516 12/04/2025 22:45:04 SOC:18276,47263,37954,114800,67,62,62,-22 03517 12/04/2025 22:55:04 Discharge level 035 AH, SOC: 66%, I:-11A, L:3768, l:3754, H:3774, B:006, PT:031C, BT:039C, PV:105597, M:Charge 03518 12/04/2025 22:55:04 SOC:16672,47649,35981,114800,69,64,66,-22 03519 12/04/2025 23:05:12 Discharge level 034 AH, SOC: 68%, I:-11A, L:3788, l:3773, H:3795, B:007, PT:031C, BT:041C, PV:106171, M:Charge 03520 12/04/2025 23:05:12 SOC:15930,48905,34000,114800,71,66,68,-22 03521 12/04/2025 23:15:12 Discharge level 032 AH, SOC: 70%, I:-11A, L:3809, l:3794, H:3817, B:008, PT:031C, BT:040C, PV:106755, M:Charge 03522 12/04/2025 23:15:12 SOC:15299,50227,32064,114800,73,69,70,-22 03523 12/04/2025 23:25:12 Discharge level 030 AH, SOC: 72%, I:-11A, L:3831, l:3816, H:3840, B:009, PT:031C, BT:040C, PV:107367, M:Charge 03524 12/04/2025 23:25:12 SOC:14495,51373,30132,114800,74,71,72,-21 03525 12/04/2025 23:35:12 Discharge level 028 AH, SOC: 74%, I:-11A, L:3854, l:3839, H:3862, B:008, PT:030C, BT:040C, PV:108017, M:Charge 03526 12/04/2025 23:35:12 SOC:13673,52488,28212,114800,76,73,74,-21 03527 12/04/2025 23:45:12 Discharge level 026 AH, SOC: 77%, I:-11A, L:3878, l:3863, H:3883, B:005, PT:030C, BT:041C, PV:108660, M:Charge 03528 12/04/2025 23:45:12 SOC:12733,53440,26339,114800,78,76,77,-21 03529 12/04/2025 23:55:12 Discharge level 024 AH, SOC: 79%, I:-11A, L:3901, l:3886, H:3906, B:005, PT:030C, BT:042C, PV:109321, M:Charge 03530 12/04/2025 23:55:12 SOC:11615,54239,24440,114800,79,78,79,-21 03531 12/05/2025 00:05:12 Discharge level 022 AH, SOC: 81%, I:-11A, L:3922, l:3907, H:3928, B:006, PT:029C, BT:045C, PV:109926, M:Charge 03532 12/05/2025 00:05:12 SOC:10659,55209,22534,114800,81,80,81,-21 03533 12/05/2025 00:15:20 Discharge level 020 AH, SOC: 83%, I:-11A, L:3944, l:3929, H:3949, B:005, PT:029C, BT:046C, PV:110529, M:Charge 03534 12/05/2025 00:15:20 SOC:9871,56388,20584,114800,83,82,83,-22 03535 12/05/2025 00:25:20 Discharge level 018 AH, SOC: 85%, I:-11A, L:3964, l:3949, H:3969, B:005, PT:029C, BT:046C, PV:111079, M:Charge 03536 12/05/2025 00:25:20 SOC:9077,57520,18676,114800,84,84,85,-21 03537 12/05/2025 00:35:20 Discharge level 016 AH, SOC: 87%, I:-11A, L:3985, l:3970, H:3988, B:003, PT:029C, BT:045C, PV:111630, M:Charge 03538 12/05/2025 00:35:20 SOC:8165,58523,16781,114800,86,85,87,-21 03539 12/05/2025 00:45:20 Discharge level 014 AH, SOC: 88%, I:-11A, L:4004, l:3989, H:4007, B:003, PT:028C, BT:044C, PV:112174, M:Charge 03540 12/05/2025 00:45:20 SOC:7263,59516,14905,114800,88,87,88,-21 03541 12/05/2025 00:55:20 Discharge level 013 AH, SOC: 90%, I:-11A, L:4025, l:4011, H:4027, B:002, PT:028C, BT:038C, PV:112729, M:Charge 03542 12/05/2025 00:55:20 SOC:6276,60433,13020,114800,89,89,90,-21 03543 12/05/2025 00:55:41 Charged To Full 012 AH, SOC: 90%, L:4025, H:4028, B:003, PT:028C, BT:039C, PV:112748 03544 12/05/2025 00:55:41 SOC adjusted for voltage old: 6246724uAH (soc:90%), new: 6046954uAH (soc:90%), low cell: 4025 mV 03545 12/05/2025 01:05:20 Discharge level 009 AH, SOC: 92%, I:-11A, L:4045, l:4031, H:4047, B:002, PT:028C, BT:034C, PV:113282, M:Charge 03546 12/05/2025 01:05:20 SOC:5171,61408,9683,114800,92,91,92,-21 03547 12/05/2025 01:15:20 Discharge level 007 AH, SOC: 94%, I:-11A, L:4065, l:4051, H:4067, B:002, PT:028C, BT:032C, PV:113838, M:Charge 03548 12/05/2025 01:15:20 SOC:4052,62175,7815,114800,94,93,94,-21 03549 12/05/2025 01:25:20 Discharge level 005 AH, SOC: 96%, I:-11A, L:4085, l:4071, H:4087, B:002, PT:027C, BT:031C, PV:114396, M:Charge 03550 12/05/2025 01:25:20 SOC:2967,62949,5976,114800,95,95,96,-20 03551 12/05/2025 01:35:28 Discharge level 004 AH, SOC: 98%, I:-11A, L:4104, l:4090, H:4107, B:003, PT:027C, BT:035C, PV:114954, M:Charge 03552 12/05/2025 01:35:28 SOC:1824,63674,4127,114800,97,97,98,-20 03553 12/05/2025 02:12:09 DEBUG: CAN Link Is Down 03554 12/05/2025 02:12:13 DEBUG: CAN Link Is Up 03555 12/05/2025 02:12:13 Contactor was Opened Pack V: 116013mV, Switched V: 116145mV, Prechg Pct: 100%, Dischg Cur: 90mA 03556 12/05/2025 02:12:15 System Turned Off 03557 12/05/2025 02:12:16 DEBUG: CAN Link Is Down 03558 12/05/2025 02:12:16 DEBUG: Entered Idle State 03559 12/05/2025 02:12:22 Current Sensor Zeroed old: 2507mV, new: 2504mV, corrfact: 252 03560 12/05/2025 02:12:23 Discharge level 000 AH, SOC:100%, I: 0A, L:4149, l:4146, H:4152, B:003, PT:026C, BT:035C, PV:116080, M:Idle 03561 12/05/2025 02:12:23 SOC:0,64627,0,114800,100,100,100,-4 03562 12/05/2025 02:12:43 Voltage Across Contactor: 103215mV (Okay) 03563 12/05/2025 03:39:48 System Turned On 03564 12/05/2025 03:39:48 Rev:45,Build:2023-05-20_045619 958 banka 03565 12/05/2025 03:39:48 Pack:2019_monolith,Numbricks:4 03566 12/05/2025 03:39:48 DEBUG: Entered Charging State 03567 12/05/2025 03:39:49 DEBUG: CAN NOT Receiving Syncs 03568 12/05/2025 03:39:49 DEBUG: Entered Running State 03569 12/05/2025 03:39:49 DEBUG: CAN Link Is Up 03570 12/05/2025 03:39:49 DEBUG: Resetting CAN0 due to error passive mode 03571 12/05/2025 03:39:50 Discharge level 000 AH, SOC:100%, I: 0A, L:4131, l:4128, H:4134, B:003, PT:024C, BT:035C, PV:115722, M:Bike On 03572 12/05/2025 03:39:50 SOC:0,64627,0,114800,100,100,100,-4 03573 12/05/2025 03:39:53 DEBUG: CAN Receiving Syncs 03574 12/05/2025 03:39:58 Contactor drive turned on Pack V: 115715mV, Switched V: 102281mV, Duty Cycle: 34% 03575 12/05/2025 03:39:58 Contactor was Closed Pack V: 115715mV, Switched V: 102281mV, Prechg Pct: 88%, Dischg Cur: 545mA 03576 12/05/2025 03:40:50 Discharge level 000 AH, SOC:100%, I: 0A, L:4130, l:4130, H:4133, B:003, PT:024C, BT:035C, PV:115706, M:Bike On 03577 12/05/2025 03:40:50 SOC:0,64627,0,114800,100,100,100,0 03578 12/05/2025 03:41:50 Discharge level 000 AH, SOC:100%, I: 0A, L:4130, l:4130, H:4133, B:003, PT:024C, BT:033C, PV:115688, M:Bike On 03579 12/05/2025 03:41:50 SOC:6,64626,8,114800,100,100,100,0 03580 12/05/2025 03:42:50 Discharge level 000 AH, SOC:100%, I: 29A, L:4064, l:4094, H:4080, B:016, PT:024C, BT:032C, PV:114074, M:Bike On 03581 12/05/2025 03:42:50 SOC:248,64378,254,114800,100,97,100,40 03582 12/05/2025 03:43:50 Discharge level 000 AH, SOC:100%, I: 24A, L:4065, l:4089, H:4081, B:016, PT:024C, BT:032C, PV:114100, M:Bike On 03583 12/05/2025 03:43:50 SOC:464,64104,487,114800,100,96,100,31 03584 12/05/2025 03:44:50 Discharge level 000 AH, SOC:100%, I:-19A, L:4142, l:4139, H:4146, B:004, PT:024C, BT:031C, PV:116021, M:Bike On 03585 12/05/2025 03:44:50 SOC:621,63886,665,114800,100,100,100,-4 03586 12/05/2025 03:45:50 Discharge level 000 AH, SOC:100%, I: 1A, L:4110, l:4118, H:4116, B:006, PT:024C, BT:031C, PV:115196, M:Bike On 03587 12/05/2025 03:45:50 SOC:601,63735,699,114800,100,99,100,10 03588 12/05/2025 03:46:50 Discharge level 000 AH, SOC: 99%, I: 1A, L:4107, l:4119, H:4113, B:006, PT:024C, BT:030C, PV:115104, M:Bike On 03589 12/05/2025 03:46:50 SOC:676,63640,785,114800,100,99,99,16 03590 12/05/2025 03:47:50 Discharge level 001 AH, SOC: 99%, I:332A, L:3646, l:3851, H:3732, B:086, PT:024C, BT:030C, PV:103465, M:Bike On 03591 12/05/2025 03:47:50 SOC:1073,63201,1212,114800,99,74,99,266 03592 12/05/2025 03:48:50 Discharge level 002 AH, SOC: 97%, I:105A, L:3869, l:3993, H:3915, B:046, PT:024C, BT:030C, PV:109113, M:Bike On 03593 12/05/2025 03:48:50 SOC:2394,62078,2547,114800,98,87,97,166 03594 12/05/2025 03:49:50 Discharge level 004 AH, SOC: 94%, I: 98A, L:3838, l:3975, H:3888, B:050, PT:025C, BT:030C, PV:108345, M:Bike On 03595 12/05/2025 03:49:50 SOC:4192,60709,4347,114800,97,85,94,180 03596 12/05/2025 03:50:50 Discharge level 005 AH, SOC: 91%, I:-38A, L:4025, l:4091, H:4036, B:011, PT:025C, BT:029C, PV:112924, M:Bike On 03597 12/05/2025 03:50:50 SOC:5692,59663,5865,114800,95,96,91,86 03598 12/05/2025 03:51:50 Discharge level 006 AH, SOC: 90%, I: 0A, L:4001, l:4037, H:4019, B:018, PT:025C, BT:029C, PV:112377, M:Bike On 03599 12/05/2025 03:51:50 SOC:6029,59461,6266,114800,95,92,90,49 03600 12/05/2025 03:52:50 Discharge level 007 AH, SOC: 89%, I:-24A, L:4031, l:4055, H:4042, B:011, PT:025C, BT:028C, PV:113096, M:Bike On 03601 12/05/2025 03:52:50 SOC:6737,59051,7048,114800,94,93,89,33 03602 12/05/2025 03:53:50 Discharge level 007 AH, SOC: 89%, I: 1A, L:4006, l:4027, H:4022, B:016, PT:026C, BT:028C, PV:112480, M:Bike On 03603 12/05/2025 03:53:50 SOC:6919,59131,7290,114800,94,91,89,29 03604 12/05/2025 03:54:50 Discharge level 007 AH, SOC: 89%, I: 1A, L:4018, l:4030, H:4031, B:013, PT:026C, BT:028C, PV:112772, M:Bike On 03605 12/05/2025 03:54:50 SOC:6891,59342,7347,114800,94,91,89,16 03606 12/05/2025 03:55:50 Discharge level 007 AH, SOC: 88%, I: 1A, L:4009, l:4026, H:4023, B:014, PT:026C, BT:029C, PV:112540, M:Bike On 03607 12/05/2025 03:55:50 SOC:7146,59287,7706,114800,94,90,88,23 03608 12/05/2025 03:56:50 Discharge level 007 AH, SOC: 89%, I: 1A, L:4019, l:4028, H:4031, B:012, PT:026C, BT:029C, PV:112771, M:Bike On 03609 12/05/2025 03:56:50 SOC:7138,59644,7740,114800,94,91,89,12 03610 12/05/2025 03:56:53 Contactor was Opened Pack V: 112772mV, Switched V: 112758mV, Prechg Pct: 100%, Dischg Cur: 1364mA 03611 12/05/2025 03:56:54 System Turned Off 03612 12/05/2025 03:56:54 DEBUG: CAN Link Is Down 03613 12/05/2025 03:56:54 DEBUG: Entered Idle State 03614 12/05/2025 03:57:00 Current Sensor Zeroed old: 2504mV, new: 2505mV, corrfact: 251 03615 12/05/2025 03:57:01 SOC adjusted for voltage old: 7136133uAH (soc:89%), new: 5966649uAH (soc:90%), low cell: 4022 mV 03616 12/05/2025 03:57:02 Discharge level 011 AH, SOC: 90%, I: 0A, L:4021, l:4028, H:4033, B:012, PT:026C, BT:029C, PV:112720, M:Idle 03617 12/05/2025 03:57:02 SOC:5966,59666,11480,114800,90,91,90,10 03618 12/05/2025 03:57:23 Voltage Across Contactor: 99868mV (Okay) 03619 12/05/2025 04:13:29 System Turned On 03620 12/05/2025 04:13:29 Rev:45,Build:2023-05-20_045619 958 banka 03621 12/05/2025 04:13:29 Pack:2019_monolith,Numbricks:4 03622 12/05/2025 04:13:29 DEBUG: Entered Running State 03623 12/05/2025 04:13:29 DEBUG: CAN NOT Receiving Syncs 03624 12/05/2025 04:13:29 DEBUG: CAN Link Is Up 03625 12/05/2025 04:13:30 DEBUG: Resetting CAN0 due to error passive mode 03626 12/05/2025 04:13:30 Discharge level 011 AH, SOC: 89%, I: 0A, L:4036, l:4043, H:4043, B:007, PT:025C, BT:038C, PV:113167, M:Bike On 03627 12/05/2025 04:13:30 SOC:7133,59666,11480,114800,90,92,89,10 03628 12/05/2025 04:13:33 DEBUG: CAN Receiving Syncs 03629 12/05/2025 04:13:33 Contactor drive turned on Pack V: 113149mV, Switched V: 99052mV, Duty Cycle: 35% 03630 12/05/2025 04:13:33 Contactor was Closed Pack V: 113149mV, Switched V: 99052mV, Prechg Pct: 88%, Dischg Cur: 545mA 03631 12/05/2025 04:14:30 Discharge level 011 AH, SOC: 89%, I: 1A, L:4035, l:4040, H:4043, B:008, PT:025C, BT:036C, PV:113151, M:Bike On 03632 12/05/2025 04:14:30 SOC:7092,60154,11493,114800,90,92,89,7 03633 12/05/2025 04:15:30 Discharge level 011 AH, SOC: 89%, I: 1A, L:4035, l:4039, H:4043, B:008, PT:025C, BT:035C, PV:113151, M:Bike On 03634 12/05/2025 04:15:30 SOC:7088,60721,11508,114800,90,92,89,5 03635 12/05/2025 04:16:30 Discharge level 011 AH, SOC: 89%, I: 1A, L:4035, l:4038, H:4043, B:008, PT:025C, BT:034C, PV:113144, M:Bike On 03636 12/05/2025 04:16:30 SOC:7088,61283,11524,114800,90,92,89,4 03637 12/05/2025 04:17:30 Discharge level 011 AH, SOC: 89%, I: 30A, L:3993, l:4015, H:4007, B:014, PT:025C, BT:033C, PV:112073, M:Bike On 03638 12/05/2025 04:17:30 SOC:7159,61332,11732,114800,90,90,89,30 03639 12/05/2025 04:18:30 Discharge level 011 AH, SOC: 89%, I: 1A, L:4025, l:4032, H:4033, B:008, PT:025C, BT:032C, PV:112877, M:Bike On 03640 12/05/2025 04:18:30 SOC:7179,61456,11863,114800,90,91,89,10 03641 12/05/2025 04:19:30 Discharge level 012 AH, SOC: 89%, I: 1A, L:4022, l:4029, H:4031, B:009, PT:025C, BT:032C, PV:112812, M:Bike On 03642 12/05/2025 04:19:30 SOC:7285,61671,12017,114800,90,91,89,9 03643 12/05/2025 04:20:30 Discharge level 012 AH, SOC: 88%, I: 48A, L:3940, l:3982, H:3962, B:022, PT:025C, BT:031C, PV:110735, M:Bike On 03644 12/05/2025 04:20:30 SOC:7610,61704,12395,114800,90,86,88,56 03645 12/05/2025 04:21:30 Discharge level 012 AH, SOC: 88%, I: 18A, L:3989, l:4005, H:4003, B:014, PT:025C, BT:031C, PV:111966, M:Bike On 03646 12/05/2025 04:21:30 SOC:7668,61761,12567,114800,90,89,88,22 03647 12/05/2025 04:22:30 Discharge level 013 AH, SOC: 87%, I: 1A, L:3978, l:4013, H:3991, B:013, PT:025C, BT:030C, PV:111657, M:Bike On 03648 12/05/2025 04:22:30 SOC:8186,61459,13190,114800,89,89,87,46 03649 12/05/2025 04:23:30 Discharge level 014 AH, SOC: 86%, I:159A, L:3756, l:3871, H:3811, B:055, PT:026C, BT:030C, PV:106130, M:Bike On 03650 12/05/2025 04:23:30 SOC:8997,61006,14119,114800,88,76,86,151 03651 12/05/2025 04:24:30 Discharge level 014 AH, SOC: 85%, I: 68A, L:3872, l:3936, H:3905, B:033, PT:026C, BT:030C, PV:109020, M:Bike On 03652 12/05/2025 04:24:30 SOC:9520,60887,14698,114800,88,82,85,85 03653 12/05/2025 04:25:30 Discharge level 015 AH, SOC: 84%, I:115A, L:3798, l:3893, H:3845, B:047, PT:026C, BT:029C, PV:107194, M:Bike On 03654 12/05/2025 04:25:30 SOC:9901,60815,15178,114800,87,78,84,124 03655 12/05/2025 04:26:30 Discharge level 016 AH, SOC: 82%, I: 53A, L:3869, l:3930, H:3899, B:030, PT:026C, BT:030C, PV:108896, M:Bike On 03656 12/05/2025 04:26:30 SOC:10972,60472,16325,114800,86,82,82,79 03657 12/05/2025 04:27:30 Discharge level 017 AH, SOC: 81%, I: 31A, L:3886, l:3936, H:3913, B:027, PT:026C, BT:029C, PV:109334, M:Bike On 03658 12/05/2025 04:27:30 SOC:11687,60538,17059,114800,86,82,81,67 03659 12/05/2025 04:28:30 Discharge level 017 AH, SOC: 80%, I: 46A, L:3870, l:3931, H:3898, B:028, PT:026C, BT:029C, PV:108906, M:Bike On 03660 12/05/2025 04:28:30 SOC:12312,60700,17714,114800,85,82,80,81 03661 12/05/2025 04:29:30 Discharge level 018 AH, SOC: 79%, I: 34A, L:3891, l:3939, H:3915, B:024, PT:027C, BT:029C, PV:109415, M:Bike On 03662 12/05/2025 04:29:30 SOC:12795,60665,18362,114800,85,82,79,64 03663 12/05/2025 04:30:30 Discharge level 019 AH, SOC: 77%, I:524A, L:3259, l:3650, H:3400, B:141, PT:027C, BT:029C, PV: 93761, M:Bike On 03664 12/05/2025 04:30:30 SOC:14351,59983,19942,114800,83,48,77,515 03665 12/05/2025 04:30:30 Discharge cutback 73% 03666 12/05/2025 04:30:30 628A 03667 12/05/2025 04:31:30 Discharge level 021 AH, SOC: 73%, I: 37A, L:3778, l:3885, H:3810, B:032, PT:029C, BT:029C, PV:106413, M:Bike On 03668 12/05/2025 04:31:30 SOC:16127,59202,21913,114800,81,77,73,144 03669 12/05/2025 04:32:30 Discharge level 022 AH, SOC: 73%, I: 50A, L:3790, l:3864, H:3822, B:032, PT:029C, BT:029C, PV:106747, M:Bike On 03670 12/05/2025 04:32:30 SOC:16565,59704,22411,114800,81,75,73,101 03671 12/05/2025 04:33:30 Discharge level 022 AH, SOC: 73%, I: 1A, L:3866, l:3889, H:3883, B:017, PT:029C, BT:029C, PV:108596, M:Bike On 03672 12/05/2025 04:33:30 SOC:16664,60312,22613,114800,81,78,73,32 03673 12/05/2025 04:33:43 Contactor was Opened Pack V: 108685mV, Switched V: 108622mV, Prechg Pct: 100%, Dischg Cur: 1091mA 03674 12/05/2025 04:33:44 System Turned Off 03675 12/05/2025 04:33:44 DEBUG: CAN Link Is Down 03676 12/05/2025 04:33:45 DEBUG: Entered Idle State 03677 12/05/2025 04:33:50 Current Sensor Zeroed old: 2505mV, new: 2507mV, corrfact: 249 03678 12/05/2025 04:33:52 Discharge level 022 AH, SOC: 73%, I: 0A, L:3872, l:3891, H:3888, B:016, PT:029C, BT:029C, PV:108754, M:Idle 03679 12/05/2025 04:33:52 SOC:16660,60513,22617,114800,81,78,73,27 03680 12/05/2025 04:34:13 Voltage Across Contactor: 95938mV (Okay) 03681 12/05/2025 04:41:31 System Turned On 03682 12/05/2025 04:41:31 Rev:45,Build:2023-05-20_045619 958 banka 03683 12/05/2025 04:41:31 Pack:2019_monolith,Numbricks:4 03684 12/05/2025 04:41:31 DEBUG: Entered Running State 03685 12/05/2025 04:41:31 DEBUG: CAN NOT Receiving Syncs 03686 12/05/2025 04:41:31 DEBUG: CAN Link Is Up 03687 12/05/2025 04:41:32 DEBUG: Resetting CAN0 due to error passive mode 03688 12/05/2025 04:41:32 Discharge level 022 AH, SOC: 73%, I: 0A, L:3902, l:3921, H:3914, B:012, PT:029C, BT:036C, PV:109511, M:Bike On 03689 12/05/2025 04:41:32 SOC:16655,60513,22617,114800,81,81,73,27 03690 12/05/2025 04:41:35 DEBUG: CAN Receiving Syncs 03691 12/05/2025 04:41:36 Contactor drive turned on Pack V: 109507mV, Switched V: 95940mV, Duty Cycle: 36% 03692 12/05/2025 04:41:36 Contactor was Closed Pack V: 109507mV, Switched V: 95940mV, Prechg Pct: 88%, Dischg Cur: 545mA 03693 12/05/2025 04:42:32 Discharge level 022 AH, SOC: 74%, I: 0A, L:3903, l:3915, H:3914, B:011, PT:029C, BT:036C, PV:109523, M:Bike On 03694 12/05/2025 04:42:32 SOC:16198,60520,22617,114800,81,80,74,16 03695 12/05/2025 04:43:32 Discharge level 022 AH, SOC: 74%, I: 0A, L:3903, l:3911, H:3915, B:012, PT:029C, BT:035C, PV:109538, M:Bike On 03696 12/05/2025 04:43:32 SOC:15810,60525,22617,114800,81,80,74,11 03697 12/05/2025 04:44:32 Discharge level 022 AH, SOC: 75%, I: 0A, L:3904, l:3910, H:3915, B:011, PT:029C, BT:034C, PV:109551, M:Bike On 03698 12/05/2025 04:44:32 SOC:15460,60535,22617,114800,81,80,75,8 03699 12/05/2025 04:45:32 Discharge level 022 AH, SOC: 75%, I: 1A, L:3896, l:3910, H:3908, B:012, PT:029C, BT:034C, PV:109343, M:Bike On 03700 12/05/2025 04:45:32 SOC:15376,60749,22757,114800,81,80,75,19 03701 12/05/2025 04:46:32 Discharge level 022 AH, SOC: 75%, I: 0A, L:3895, l:3902, H:3907, B:012, PT:029C, BT:033C, PV:109315, M:Bike On 03702 12/05/2025 04:46:32 SOC:15360,60946,22928,114800,81,79,75,10 03703 12/05/2025 04:47:32 Discharge level 023 AH, SOC: 75%, I: 0A, L:3873, l:3895, H:3886, B:013, PT:029C, BT:032C, PV:108720, M:Bike On 03704 12/05/2025 04:47:32 SOC:15608,60953,23371,114800,80,78,75,31 03705 12/05/2025 04:48:32 Discharge level 023 AH, SOC: 75%, I: 49A, L:3825, l:3862, H:3848, B:023, PT:029C, BT:032C, PV:107554, M:Bike On 03706 12/05/2025 04:48:32 SOC:15676,61144,23591,114800,80,75,75,51 03707 12/05/2025 04:49:32 Discharge level 024 AH, SOC: 74%, I:-25A, L:3893, l:3901, H:3901, B:008, PT:029C, BT:032C, PV:109150, M:Bike On 03708 12/05/2025 04:49:32 SOC:16039,60935,24183,114800,79,79,74,12 03709 12/05/2025 04:50:32 Discharge level 024 AH, SOC: 74%, I: 61A, L:3789, l:3843, H:3815, B:026, PT:029C, BT:032C, PV:106582, M:Bike On 03710 12/05/2025 04:50:32 SOC:16383,61003,24651,114800,79,73,74,75 03711 12/05/2025 04:51:32 Discharge level 025 AH, SOC: 73%, I:-15A, L:3858, l:3875, H:3868, B:010, PT:029C, BT:032C, PV:108228, M:Bike On 03712 12/05/2025 04:51:32 SOC:17050,60972,25412,114800,78,77,73,25 03713 12/05/2025 04:52:32 Discharge level 025 AH, SOC: 72%, I: 0A, L:3846, l:3864, H:3857, B:011, PT:029C, BT:031C, PV:107913, M:Bike On 03714 12/05/2025 04:52:32 SOC:17238,61055,25751,114800,78,75,72,25 03715 12/05/2025 04:53:32 Discharge level 025 AH, SOC: 72%, I: 0A, L:3854, l:3864, H:3866, B:012, PT:029C, BT:031C, PV:108137, M:Bike On 03716 12/05/2025 04:53:32 SOC:17205,61183,25870,114800,78,75,72,14 03717 12/05/2025 04:54:32 Discharge level 025 AH, SOC: 73%, I: 0A, L:3861, l:3867, H:3872, B:011, PT:029C, BT:031C, PV:108317, M:Bike On 03718 12/05/2025 04:54:32 SOC:16981,61199,25872,114800,78,76,73,8 03719 12/05/2025 04:55:05 Contactor was Opened Pack V: 108382mV, Switched V: 108307mV, Prechg Pct: 100%, Dischg Cur: 545mA 03720 12/05/2025 04:55:06 System Turned Off 03721 12/05/2025 04:55:07 DEBUG: CAN Link Is Down 03722 12/05/2025 04:55:07 DEBUG: Entered Idle State 03723 12/05/2025 04:55:13 Current Sensor Zeroed old: 2507mV, new: 2504mV, corrfact: 252 03724 12/05/2025 04:55:14 Discharge level 025 AH, SOC: 73%, I: 0A, L:3864, l:3868, H:3875, B:011, PT:029C, BT:031C, PV:108407, M:Idle 03725 12/05/2025 04:55:14 SOC:16851,61199,25872,114800,78,76,73,6 03726 12/05/2025 04:55:21 System Turned On 03727 12/05/2025 04:55:21 Rev:45,Build:2023-05-20_045619 958 banka 03728 12/05/2025 04:55:21 Pack:2019_monolith,Numbricks:4 03729 12/05/2025 04:55:21 DEBUG: Entered Running State 03730 12/05/2025 04:55:21 DEBUG: CAN NOT Receiving Syncs 03731 12/05/2025 04:55:22 DEBUG: CAN Link Is Up 03732 12/05/2025 04:55:22 DEBUG: Resetting CAN0 due to error passive mode 03733 12/05/2025 04:55:22 Discharge level 025 AH, SOC: 73%, I: 0A, L:3864, l:3868, H:3875, B:011, PT:029C, BT:031C, PV:108411, M:Bike On 03734 12/05/2025 04:55:22 SOC:16849,61199,25872,114800,78,76,73,6 03735 12/05/2025 04:55:26 DEBUG: CAN Receiving Syncs 03736 12/05/2025 04:55:26 Contactor drive turned on Pack V: 108407mV, Switched V: 95507mV, Duty Cycle: 37% 03737 12/05/2025 04:55:26 Contactor was Closed Pack V: 108407mV, Switched V: 95507mV, Prechg Pct: 88%, Dischg Cur: 636mA 03738 12/05/2025 04:55:28 DEBUG: Entered Charging State 03739 12/05/2025 04:55:28 DEBUG: CAN NOT Receiving Syncs 03740 12/05/2025 04:55:29 Discharge level 025 AH, SOC: 73%, I: 1A, L:3864, l:3868, H:3875, B:011, PT:029C, BT:031C, PV:108414, M:Charge 03741 12/05/2025 04:55:29 SOC:16834,61207,25873,114800,78,76,73,6 03742 12/05/2025 04:55:29 DEBUG: CAN Receiving Syncs 03743 12/05/2025 05:05:29 Discharge level 024 AH, SOC: 80%, I:-10A, L:3923, l:3909, H:3931, B:008, PT:029C, BT:038C, PV:110005, M:Charge 03744 12/05/2025 05:05:29 SOC:11901,58185,24000,114800,80,80,80,-20 03745 12/05/2025 05:15:29 Discharge level 022 AH, SOC: 83%, I:-11A, L:3948, l:3934, H:3955, B:007, PT:029C, BT:040C, PV:110687, M:Charge 03746 12/05/2025 05:15:29 SOC:10209,58393,22117,114800,81,82,83,-21 03747 12/05/2025 05:25:29 Discharge level 020 AH, SOC: 85%, I:-11A, L:3970, l:3956, H:3976, B:006, PT:029C, BT:042C, PV:111294, M:Charge 03748 12/05/2025 05:25:29 SOC:9054,59126,20247,114800,83,84,85,-21 03749 12/05/2025 05:35:37 Discharge level 018 AH, SOC: 87%, I:-11A, L:3992, l:3978, H:3996, B:004, PT:028C, BT:042C, PV:111876, M:Charge 03750 12/05/2025 05:35:37 SOC:7931,59917,18351,114800,85,86,87,-21 03751 12/05/2025 05:45:37 Discharge level 016 AH, SOC: 89%, I:-10A, L:4014, l:4000, H:4018, B:004, PT:028C, BT:041C, PV:112468, M:Charge 03752 12/05/2025 05:45:37 SOC:6934,60789,16498,114800,86,88,89,-20 03753 12/05/2025 05:51:38 Charged To Full 015 AH, SOC: 90%, L:4025, H:4029, B:004, PT:028C, BT:042C, PV:112729 03754 12/05/2025 05:51:38 SOC adjusted for voltage old: 6314432uAH (soc:90%), new: 6128243uAH (soc:90%), low cell: 4025 mV 03755 12/05/2025 05:55:37 Discharge level 010 AH, SOC: 91%, I:-11A, L:4035, l:4021, H:4038, B:003, PT:028C, BT:041C, PV:113034, M:Charge 03756 12/05/2025 05:55:37 SOC:5730,61615,10756,114800,91,90,91,-20 03757 12/05/2025 06:05:37 Discharge level 008 AH, SOC: 93%, I:-10A, L:4055, l:4042, H:4059, B:004, PT:028C, BT:036C, PV:113601, M:Charge 03758 12/05/2025 06:05:37 SOC:4677,62391,8945,114800,93,92,93,-20 03759 12/05/2025 06:15:37 Discharge level 007 AH, SOC: 95%, I:-10A, L:4077, l:4064, H:4079, B:002, PT:028C, BT:034C, PV:114189, M:Charge 03760 12/05/2025 06:15:37 SOC:3417,62942,7151,114800,94,94,95,-20 03761 12/05/2025 06:25:37 Discharge level 005 AH, SOC: 97%, I:-10A, L:4096, l:4083, H:4099, B:003, PT:027C, BT:033C, PV:114741, M:Charge 03762 12/05/2025 06:25:37 SOC:2228,63537,5385,114800,96,96,97,-20 03763 12/05/2025 07:02:22 DEBUG: Entered Standby State 03764 12/05/2025 07:02:22 DEBUG: CAN NOT Receiving Syncs 03765 12/05/2025 07:02:22 System Turned Off 03766 12/05/2025 07:02:23 DEBUG: CAN Link Is Down 03767 12/05/2025 07:02:23 DEBUG: Entered Idle State 03768 12/05/2025 07:02:23 Contactor was Opened Pack V: 116159mV, Switched V: 116066mV, Prechg Pct: 100%, Dischg Cur: 545mA 03769 12/05/2025 07:02:30 System Turned On 03770 12/05/2025 07:02:30 Rev:45,Build:2023-05-20_045619 958 banka 03771 12/05/2025 07:02:30 Pack:2019_monolith,Numbricks:4 03772 12/05/2025 07:02:30 DEBUG: Entered Standby State 03773 12/05/2025 07:02:30 DEBUG: CAN Link Is Up 03774 12/05/2025 07:02:30 DEBUG: Entered Running State 03775 12/05/2025 07:02:31 DEBUG: Resetting CAN0 due to error passive mode 03776 12/05/2025 07:02:32 Discharge level 000 AH, SOC:100%, I: 0A, L:4146, l:4143, H:4149, B:003, PT:027C, BT:036C, PV:116119, M:Bike On 03777 12/05/2025 07:02:32 SOC:0,64564,0,114800,100,100,100,-5 03778 12/05/2025 07:02:34 DEBUG: CAN Receiving Syncs 03779 12/05/2025 07:02:35 Contactor drive turned on Pack V: 116101mV, Switched V: 102596mV, Duty Cycle: 34% 03780 12/05/2025 07:02:35 Contactor was Closed Pack V: 116101mV, Switched V: 102596mV, Prechg Pct: 88%, Dischg Cur: 636mA 03781 12/05/2025 07:03:32 Discharge level 000 AH, SOC:100%, I: 1A, L:4143, l:4143, H:4145, B:002, PT:027C, BT:034C, PV:116022, M:Bike On 03782 12/05/2025 07:03:32 SOC:2,64564,4,114800,100,100,100,0 03783 12/05/2025 07:04:32 Discharge level 000 AH, SOC:100%, I: 1A, L:4141, l:4141, H:4143, B:002, PT:027C, BT:034C, PV:115974, M:Bike On 03784 12/05/2025 07:04:32 SOC:5,64564,9,114800,100,100,100,0 03785 12/05/2025 07:05:32 Discharge level 000 AH, SOC:100%, I: 1A, L:4136, l:4140, H:4139, B:003, PT:027C, BT:034C, PV:115864, M:Bike On 03786 12/05/2025 07:05:32 SOC:53,64551,59,114800,100,100,100,5 03787 12/05/2025 07:06:32 Discharge level 000 AH, SOC:100%, I: 60A, L:4042, l:4077, H:4063, B:021, PT:027C, BT:034C, PV:113536, M:Bike On 03788 12/05/2025 07:06:32 SOC:271,64417,288,114800,100,95,100,51 03789 12/05/2025 07:07:32 Discharge level 000 AH, SOC: 99%, I: 55A, L:4022, l:4068, H:4046, B:024, PT:027C, BT:034C, PV:113027, M:Bike On 03790 12/05/2025 07:07:32 SOC:662,64136,692,114800,100,94,99,66 03791 12/05/2025 07:08:32 Discharge level 000 AH, SOC: 99%, I: -3A, L:4132, l:4133, H:4135, B:003, PT:027C, BT:033C, PV:115734, M:Bike On 03792 12/05/2025 07:08:32 SOC:662,64053,739,114800,100,100,99,1 03793 12/05/2025 07:09:32 Discharge level 000 AH, SOC: 99%, I: 1A, L:4120, l:4124, H:4124, B:004, PT:027C, BT:033C, PV:115432, M:Bike On 03794 12/05/2025 07:09:32 SOC:704,63950,833,114800,100,100,99,6 03795 12/05/2025 07:10:32 Discharge level 001 AH, SOC: 99%, I:-26A, L:4133, l:4147, H:4137, B:004, PT:027C, BT:032C, PV:115785, M:Bike On 03796 12/05/2025 07:10:32 SOC:1176,63528,1346,114800,99,100,99,20 03797 12/05/2025 07:11:32 Discharge level 002 AH, SOC: 97%, I: 98A, L:3927, l:4022, H:3964, B:037, PT:027C, BT:032C, PV:110603, M:Bike On 03798 12/05/2025 07:11:32 SOC:2203,62690,2447,114800,98,90,97,137 03799 12/05/2025 07:12:32 Discharge level 003 AH, SOC: 95%, I:109A, L:3909, l:4005, H:3949, B:040, PT:027C, BT:032C, PV:110170, M:Bike On 03800 12/05/2025 07:12:32 SOC:3351,61963,3599,114800,97,89,95,144 03801 12/05/2025 07:13:32 Discharge level 005 AH, SOC: 93%, I: 64A, L:3925, l:4014, H:3959, B:034, PT:027C, BT:032C, PV:110516, M:Bike On 03802 12/05/2025 07:13:32 SOC:4767,61160,5019,114800,96,89,93,132 03803 12/05/2025 07:14:32 Discharge level 006 AH, SOC: 90%, I: 3A, L:3975, l:4040, H:3997, B:022, PT:028C, BT:031C, PV:111717, M:Bike On 03804 12/05/2025 07:14:32 SOC:6381,60399,6638,114800,95,92,90,94 03805 12/05/2025 07:15:32 Discharge level 008 AH, SOC: 86%, I:102A, L:3795, l:3936, H:3848, B:053, PT:028C, BT:031C, PV:107226, M:Bike On 03806 12/05/2025 07:15:32 SOC:8367,59631,8626,114800,93,82,86,206 03807 12/05/2025 07:16:32 Discharge level 010 AH, SOC: 83%, I:100A, L:3799, l:3933, H:3849, B:050, PT:029C, BT:031C, PV:107303, M:Bike On 03808 12/05/2025 07:16:32 SOC:10084,59277,10347,114800,91,82,83,192 03809 12/05/2025 07:17:32 Discharge level 011 AH, SOC: 81%, I: 61A, L:3843, l:3943, H:3883, B:040, PT:029C, BT:030C, PV:108365, M:Bike On 03810 12/05/2025 07:17:32 SOC:11415,59316,11688,114800,90,83,81,142 03811 12/05/2025 07:18:32 Discharge level 013 AH, SOC: 79%, I: 93A, L:3756, l:3893, H:3811, B:055, PT:029C, BT:031C, PV:106216, M:Bike On 03812 12/05/2025 07:18:32 SOC:13036,59381,13317,114800,89,78,79,200 03813 12/05/2025 07:19:32 Discharge level 015 AH, SOC: 76%, I:101A, L:3755, l:3888, H:3807, B:052, PT:030C, BT:031C, PV:106146, M:Bike On 03814 12/05/2025 07:19:32 SOC:14797,59592,15083,114800,87,77,76,193 03815 12/05/2025 07:20:32 Discharge level 016 AH, SOC: 73%, I: 75A, L:3779, l:3885, H:3824, B:045, PT:030C, BT:031C, PV:106669, M:Bike On 03816 12/05/2025 07:20:32 SOC:16333,60076,16625,114800,86,77,73,154 03817 12/05/2025 07:21:32 Discharge level 017 AH, SOC: 71%, I: 1A, L:3848, l:3912, H:3875, B:027, PT:030C, BT:031C, PV:108292, M:Bike On 03818 12/05/2025 07:21:32 SOC:17623,60730,17956,114800,85,80,71,93 03819 12/05/2025 07:22:32 Discharge level 019 AH, SOC: 69%, I: 1A, L:3827, l:3894, H:3855, B:028, PT:031C, BT:029C, PV:107728, M:Bike On 03820 12/05/2025 07:22:32 SOC:19121,61300,19527,114800,83,78,69,101 03821 12/05/2025 07:23:32 Discharge level 021 AH, SOC: 67%, I: 3A, L:3771, l:3864, H:3808, B:037, PT:031C, BT:030C, PV:106338, M:Bike On 03822 12/05/2025 07:23:32 SOC:20806,61825,21239,114800,82,75,67,142 03823 12/05/2025 07:24:32 Discharge level 022 AH, SOC: 65%, I:112A, L:3680, l:3802, H:3734, B:054, PT:032C, BT:030C, PV:104100, M:Bike On 03824 12/05/2025 07:24:32 SOC:22131,62679,22594,114800,81,68,65,188 03825 12/05/2025 07:25:32 Discharge level 023 AH, SOC: 64%, I: 67A, L:3726, l:3812, H:3768, B:042, PT:032C, BT:030C, PV:105163, M:Bike On 03826 12/05/2025 07:25:32 SOC:23210,63724,23696,114800,80,70,64,139 03827 12/05/2025 07:26:32 Discharge level 025 AH, SOC: 62%, I:130A, L:3641, l:3765, H:3698, B:057, PT:032C, BT:030C, PV:103083, M:Bike On 03828 12/05/2025 07:26:32 SOC:24758,64468,25267,114800,78,65,62,203 03829 12/05/2025 07:27:32 Discharge level 026 AH, SOC: 60%, I:132A, L:3655, l:3772, H:3704, B:049, PT:033C, BT:030C, PV:103296, M:Bike On 03830 12/05/2025 07:27:32 SOC:26329,65279,26859,114800,77,65,60,194 03831 12/05/2025 07:28:32 Discharge level 028 AH, SOC: 58%, I: 93A, L:3645, l:3752, H:3693, B:048, PT:033C, BT:031C, PV:103027, M:Bike On 03832 12/05/2025 07:28:32 SOC:28047,66002,28589,114800,76,63,58,179 03833 12/05/2025 07:29:32 Discharge level 028 AH, SOC: 59%, I: 2A, L:3769, l:3796, H:3788, B:019, PT:033C, BT:030C, PV:105942, M:Bike On 03834 12/05/2025 07:29:32 SOC:27732,66785,28750,114800,75,69,59,48 03835 12/05/2025 07:30:32 Discharge level 028 AH, SOC: 60%, I: 23A, L:3763, l:3789, H:3782, B:019, PT:033C, BT:031C, PV:105767, M:Bike On 03836 12/05/2025 07:30:32 SOC:27512,67984,28821,114800,75,68,60,46 03837 12/05/2025 07:31:32 Discharge level 028 AH, SOC: 61%, I: 1A, L:3789, l:3801, H:3803, B:014, PT:033C, BT:031C, PV:106382, M:Bike On 03838 12/05/2025 07:31:32 SOC:27208,68885,28886,114800,75,69,61,22 03839 12/05/2025 07:32:32 Discharge level 029 AH, SOC: 61%, I:-19A, L:3801, l:3808, H:3813, B:012, PT:033C, BT:031C, PV:106651, M:Bike On 03840 12/05/2025 07:32:32 SOC:27472,70172,29203,114800,75,70,61,13 03841 12/05/2025 07:33:32 Discharge level 029 AH, SOC: 62%, I: 0A, L:3783, l:3799, H:3796, B:013, PT:033C, BT:031C, PV:106195, M:Bike On 03842 12/05/2025 07:33:32 SOC:27434,71219,29341,114800,75,69,62,28 03843 12/05/2025 07:34:32 Discharge level 029 AH, SOC: 62%, I: 1A, L:3784, l:3795, H:3797, B:013, PT:033C, BT:030C, PV:106216, M:Bike On 03844 12/05/2025 07:34:32 SOC:27546,72347,29538,114800,75,69,62,20 03845 12/05/2025 07:35:32 Discharge level 029 AH, SOC: 63%, I: 1A, L:3791, l:3798, H:3803, B:012, PT:033C, BT:030C, PV:106383, M:Bike On 03846 12/05/2025 07:35:32 SOC:27480,73452,29577,114800,75,69,63,12 03847 12/05/2025 07:36:32 Discharge level 029 AH, SOC: 63%, I: 1A, L:3789, l:3797, H:3800, B:011, PT:033C, BT:030C, PV:106300, M:Bike On 03848 12/05/2025 07:36:32 SOC:27587,74435,29759,114800,75,69,63,13 03849 12/05/2025 07:37:32 Discharge level 029 AH, SOC: 64%, I: -3A, L:3794, l:3799, H:3805, B:011, PT:033C, BT:031C, PV:106435, M:Bike On 03850 12/05/2025 07:37:32 SOC:27593,75400,29844,114800,75,69,64,8 03851 12/05/2025 07:38:32 Discharge level 030 AH, SOC: 64%, I: -5A, L:3777, l:3790, H:3788, B:011, PT:033C, BT:031C, PV:105995, M:Bike On 03852 12/05/2025 07:38:32 SOC:27710,75415,30301,114800,74,68,64,21 03853 12/05/2025 07:39:32 Discharge level 030 AH, SOC: 64%, I: 1A, L:3781, l:3791, H:3792, B:011, PT:033C, BT:030C, PV:106083, M:Bike On 03854 12/05/2025 07:39:32 SOC:27658,75856,30448,114800,74,68,64,16 03855 12/05/2025 07:40:32 Discharge level 030 AH, SOC: 64%, I: 1A, L:3785, l:3791, H:3794, B:009, PT:033C, BT:031C, PV:106145, M:Bike On 03856 12/05/2025 07:40:32 SOC:27647,76425,30568,114800,74,68,64,11 03857 12/05/2025 07:41:32 Discharge level 030 AH, SOC: 64%, I: 1A, L:3772, l:3787, H:3783, B:011, PT:033C, BT:031C, PV:105832, M:Bike On 03858 12/05/2025 07:41:32 SOC:27924,76862,30928,114800,74,68,64,25 03859 12/05/2025 07:42:32 Discharge level 030 AH, SOC: 64%, I: 1A, L:3780, l:3786, H:3789, B:009, PT:033C, BT:031C, PV:106023, M:Bike On 03860 12/05/2025 07:42:32 SOC:27855,77295,30994,114800,74,68,64,11 03861 12/05/2025 07:43:32 Discharge level 031 AH, SOC: 64%, I: 1A, L:3774, l:3783, H:3784, B:010, PT:033C, BT:031C, PV:105867, M:Bike On 03862 12/05/2025 07:43:32 SOC:28000,77583,31269,114800,73,67,64,15 03863 12/05/2025 07:44:32 Discharge level 031 AH, SOC: 64%, I: 2A, L:3767, l:3783, H:3777, B:010, PT:033C, BT:030C, PV:105682, M:Bike On 03864 12/05/2025 07:44:32 SOC:28202,77883,31548,114800,73,67,64,26 03865 12/05/2025 07:45:32 Discharge level 031 AH, SOC: 65%, I: 1A, L:3777, l:3783, H:3785, B:008, PT:033C, BT:031C, PV:105896, M:Bike On 03866 12/05/2025 07:45:32 SOC:28165,78391,31580,114800,73,67,65,10 03867 12/05/2025 07:46:32 Discharge level 031 AH, SOC: 65%, I: 2A, L:3771, l:3781, H:3779, B:008, PT:033C, BT:031C, PV:105744, M:Bike On 03868 12/05/2025 07:46:32 SOC:28245,78765,31739,114800,73,67,65,16 03869 12/05/2025 07:47:32 Discharge level 031 AH, SOC: 65%, I: 1A, L:3770, l:3780, H:3778, B:008, PT:033C, BT:031C, PV:105703, M:Bike On 03870 12/05/2025 07:47:32 SOC:28215,78703,31954,114800,73,67,65,16 03871 12/05/2025 07:48:32 Discharge level 032 AH, SOC: 65%, I: 29A, L:3748, l:3766, H:3760, B:012, PT:033C, BT:031C, PV:105179, M:Bike On 03872 12/05/2025 07:48:32 SOC:28208,79005,32049,114800,73,65,65,29 03873 12/05/2025 07:49:32 Discharge level 032 AH, SOC: 65%, I: 1A, L:3773, l:3779, H:3781, B:008, PT:033C, BT:031C, PV:105784, M:Bike On 03874 12/05/2025 07:49:32 SOC:28242,79384,32143,114800,73,67,65,9 03875 12/05/2025 07:50:32 Discharge level 032 AH, SOC: 65%, I: 1A, L:3776, l:3780, H:3782, B:006, PT:033C, BT:031C, PV:105838, M:Bike On 03876 12/05/2025 07:50:32 SOC:28281,79911,32183,114800,72,67,65,6 03877 12/05/2025 07:51:32 Discharge level 032 AH, SOC: 65%, I: 1A, L:3777, l:3780, H:3783, B:006, PT:033C, BT:032C, PV:105860, M:Bike On 03878 12/05/2025 07:51:32 SOC:28316,80408,32220,114800,72,67,65,5 03879 12/05/2025 07:52:32 Discharge level 032 AH, SOC: 65%, I: 1A, L:3776, l:3780, H:3783, B:007, PT:033C, BT:031C, PV:105841, M:Bike On 03880 12/05/2025 07:52:32 SOC:28356,80815,32278,114800,72,67,65,6 03881 12/05/2025 07:53:32 Discharge level 032 AH, SOC: 65%, I: 1A, L:3773, l:3778, H:3780, B:007, PT:032C, BT:032C, PV:105771, M:Bike On 03882 12/05/2025 07:53:32 SOC:28449,81118,32398,114800,72,67,65,8 03883 12/05/2025 07:54:32 Discharge level 032 AH, SOC: 66%, I: 1A, L:3774, l:3777, H:3782, B:008, PT:032C, BT:032C, PV:105802, M:Bike On 03884 12/05/2025 07:54:32 SOC:28497,81516,32447,114800,72,67,66,6 03885 12/05/2025 07:55:04 Contactor was Opened Pack V: 105834mV, Switched V: 105747mV, Prechg Pct: 100%, Dischg Cur: 1546mA 03886 12/05/2025 07:55:04 System Turned Off 03887 12/05/2025 07:55:05 DEBUG: CAN Link Is Down 03888 12/05/2025 07:55:05 DEBUG: Entered Idle State 03889 12/05/2025 07:55:11 Current Sensor Zeroed old: 2504mV, new: 2507mV, corrfact: 249 03890 12/05/2025 07:55:12 Discharge level 032 AH, SOC: 66%, I: 0A, L:3777, l:3779, H:3784, B:007, PT:032C, BT:032C, PV:105865, M:Idle 03891 12/05/2025 07:55:12 SOC:28508,81746,32461,114800,72,67,66,3 03892 12/05/2025 07:55:34 Voltage Across Contactor: 93077mV (Okay) 03893 12/05/2025 08:47:16 System Turned On 03894 12/05/2025 08:47:16 Rev:45,Build:2023-05-20_045619 958 banka 03895 12/05/2025 08:47:16 Pack:2019_monolith,Numbricks:4 03896 12/05/2025 08:47:16 DEBUG: Entered Running State 03897 12/05/2025 08:47:16 DEBUG: CAN NOT Receiving Syncs 03898 12/05/2025 08:47:16 DEBUG: CAN Link Is Up 03899 12/05/2025 08:47:17 DEBUG: Resetting CAN0 due to error passive mode 03900 07/29/1990 08:19:33 Discharge level 1196 AH, SOC: 58%, I:542A, L:6141, l:25938, H:13058, B:6917, PT:105C, BT:068C, PV:1312899872, M:None 03901 12/05/2025 09:02:31 DEBUG: CAN Link Is Up 03902 12/05/2025 09:02:32 DEBUG: Resetting CAN0 due to error passive mode 03903 12/05/2025 09:02:32 Discharge level 032 AH, SOC: 66%, I: 0A, L:3785, l:3787, H:3793, B:008, PT:029C, BT:029C, PV:106112, M:Bike On 03904 12/05/2025 09:02:32 SOC:28478,81987,32470,114800,72,68,66,3 03905 12/05/2025 09:02:35 DEBUG: CAN Receiving Syncs 03906 12/05/2025 09:02:35 Contactor drive turned on Pack V: 106102mV, Switched V: 92908mV, Duty Cycle: 37% 03907 12/05/2025 09:02:35 Contactor was Closed Pack V: 106102mV, Switched V: 92908mV, Prechg Pct: 88%, Dischg Cur: 909mA 03908 12/05/2025 09:03:32 Discharge level 032 AH, SOC: 66%, I: 1A, L:3784, l:3786, H:3792, B:008, PT:029C, BT:030C, PV:106085, M:Bike On 03909 12/05/2025 09:03:32 SOC:28485,82542,32490,114800,72,68,66,3 03910 12/05/2025 09:04:32 Discharge level 032 AH, SOC: 66%, I: 1A, L:3784, l:3786, H:3792, B:008, PT:029C, BT:029C, PV:106078, M:Bike On 03911 12/05/2025 09:04:32 SOC:28506,83087,32511,114800,72,68,66,3 03912 12/05/2025 09:05:32 Discharge level 032 AH, SOC: 66%, I: 1A, L:3784, l:3786, H:3791, B:007, PT:029C, BT:029C, PV:106065, M:Bike On 03913 12/05/2025 09:05:32 SOC:28527,83503,32532,114800,72,67,66,2 03914 12/05/2025 09:06:32 Discharge level 032 AH, SOC: 66%, I: 1A, L:3783, l:3784, H:3791, B:008, PT:029C, BT:030C, PV:106053, M:Bike On 03915 12/05/2025 09:06:32 SOC:28548,83759,32554,114800,72,67,66,2 03916 12/05/2025 09:07:32 Discharge level 032 AH, SOC: 66%, I: 1A, L:3783, l:3784, H:3790, B:007, PT:029C, BT:030C, PV:106042, M:Bike On 03917 12/05/2025 09:07:32 SOC:28569,83998,32575,114800,72,67,66,2 03918 12/05/2025 09:08:32 Discharge level 032 AH, SOC: 67%, I: 0A, L:3783, l:3784, H:3791, B:008, PT:029C, BT:030C, PV:106055, M:Bike On 03919 12/05/2025 09:08:32 SOC:28569,84176,32592,114800,72,67,67,2 03920 12/05/2025 09:09:32 Discharge level 032 AH, SOC: 67%, I: 0A, L:3783, l:3784, H:3791, B:008, PT:029C, BT:030C, PV:106045, M:Bike On 03921 12/05/2025 09:09:32 SOC:28541,84281,32603,114800,72,67,67,2 03922 12/05/2025 09:10:32 Discharge level 032 AH, SOC: 67%, I: 1A, L:3782, l:3783, H:3790, B:008, PT:029C, BT:030C, PV:106033, M:Bike On 03923 12/05/2025 09:10:32 SOC:28516,84376,32614,114800,72,67,67,2 03924 12/05/2025 09:11:32 Discharge level 032 AH, SOC: 67%, I: 1A, L:3782, l:3783, H:3790, B:008, PT:029C, BT:030C, PV:106031, M:Bike On 03925 12/05/2025 09:11:32 SOC:28493,84463,32625,114800,72,67,67,2 03926 12/05/2025 09:12:32 Discharge level 032 AH, SOC: 67%, I:106A, L:3672, l:3726, H:3697, B:025, PT:029C, BT:030C, PV:103227, M:Bike On 03927 12/05/2025 09:12:32 SOC:28531,84519,32690,114800,72,60,67,77 03928 12/05/2025 09:13:32 Discharge level 032 AH, SOC: 66%, I: 1A, L:3772, l:3778, H:3780, B:008, PT:029C, BT:030C, PV:105755, M:Bike On 03929 12/05/2025 09:13:32 SOC:28757,84444,32954,114800,72,67,66,8 03930 12/05/2025 09:14:32 Discharge level 033 AH, SOC: 66%, I: 0A, L:3772, l:3777, H:3779, B:007, PT:029C, BT:030C, PV:105735, M:Bike On 03931 12/05/2025 09:14:32 SOC:28832,84419,33071,114800,72,66,66,7 03932 12/05/2025 09:15:32 Discharge level 033 AH, SOC: 66%, I: 31A, L:3744, l:3762, H:3754, B:010, PT:029C, BT:030C, PV:105003, M:Bike On 03933 12/05/2025 09:15:32 SOC:28835,84345,33137,114800,72,65,66,25 03934 12/05/2025 09:16:32 Discharge level 033 AH, SOC: 66%, I: 1A, L:3773, l:3776, H:3780, B:007, PT:029C, BT:030C, PV:105762, M:Bike On 03935 12/05/2025 09:16:32 SOC:28858,84354,33171,114800,72,66,66,4 03936 12/05/2025 09:17:32 Discharge level 033 AH, SOC: 66%, I:-11A, L:3782, l:3784, H:3788, B:006, PT:029C, BT:030C, PV:105983, M:Bike On 03937 12/05/2025 09:17:32 SOC:28933,84298,33269,114800,72,67,66,3 03938 12/05/2025 09:18:32 Discharge level 033 AH, SOC: 66%, I: 0A, L:3756, l:3769, H:3765, B:009, PT:029C, BT:030C, PV:105322, M:Bike On 03939 12/05/2025 09:18:32 SOC:29127,84182,33485,114800,71,66,66,19 03940 12/05/2025 09:19:32 Discharge level 033 AH, SOC: 66%, I: 1A, L:3762, l:3769, H:3770, B:008, PT:029C, BT:030C, PV:105473, M:Bike On 03941 12/05/2025 09:19:32 SOC:29231,84105,33637,114800,71,66,66,10 03942 12/05/2025 09:20:32 Discharge level 033 AH, SOC: 66%, I: 31A, L:3734, l:3754, H:3745, B:011, PT:029C, BT:030C, PV:104740, M:Bike On 03943 12/05/2025 09:20:32 SOC:29302,84200,33709,114800,71,64,66,28 03944 12/05/2025 09:21:32 Discharge level 033 AH, SOC: 65%, I:-14A, L:3770, l:3772, H:3778, B:008, PT:028C, BT:030C, PV:105692, M:Bike On 03945 12/05/2025 09:21:32 SOC:29447,84121,33874,114800,71,66,65,3 03946 12/05/2025 09:22:32 Discharge level 033 AH, SOC: 65%, I: 1A, L:3758, l:3766, H:3766, B:008, PT:028C, BT:030C, PV:105366, M:Bike On 03947 12/05/2025 09:22:32 SOC:29518,83984,33985,114800,71,65,65,11 03948 12/05/2025 09:23:32 Discharge level 034 AH, SOC: 65%, I: 1A, L:3759, l:3764, H:3766, B:007, PT:028C, BT:030C, PV:105377, M:Bike On 03949 12/05/2025 09:23:32 SOC:29608,83939,34094,114800,71,65,65,8 03950 12/05/2025 09:24:32 Discharge level 034 AH, SOC: 65%, I:-13A, L:3772, l:3773, H:3778, B:006, PT:028C, BT:030C, PV:105700, M:Bike On 03951 12/05/2025 09:24:32 SOC:29720,83882,34222,114800,71,66,65,1 03952 12/05/2025 09:25:32 Discharge level 034 AH, SOC: 65%, I: 1A, L:3751, l:3760, H:3759, B:008, PT:028C, BT:030C, PV:105166, M:Bike On 03953 12/05/2025 09:25:32 SOC:29915,83650,34475,114800,70,65,65,14 03954 12/05/2025 09:26:32 Discharge level 034 AH, SOC: 65%, I: -2A, L:3756, l:3762, H:3763, B:007, PT:028C, BT:030C, PV:105297, M:Bike On 03955 12/05/2025 09:26:32 SOC:29976,83631,34575,114800,70,65,65,9 03956 12/05/2025 09:27:32 Discharge level 034 AH, SOC: 65%, I: 8A, L:3740, l:3750, H:3750, B:010, PT:028C, BT:030C, PV:104882, M:Bike On 03957 12/05/2025 09:27:32 SOC:30054,83633,34679,114800,70,63,65,14 03958 12/05/2025 09:28:32 Discharge level 035 AH, SOC: 64%, I:238A, L:3500, l:3625, H:3558, B:058, PT:028C, BT:029C, PV: 99002, M:Bike On 03959 12/05/2025 09:28:32 SOC:30368,83372,35013,114800,70,46,64,178 03960 12/05/2025 09:29:32 Discharge level 035 AH, SOC: 64%, I: 1A, L:3746, l:3753, H:3754, B:008, PT:028C, BT:030C, PV:105030, M:Bike On 03961 12/05/2025 09:29:32 SOC:30461,83338,35132,114800,70,64,64,10 03962 12/05/2025 09:30:32 Discharge level 035 AH, SOC: 64%, I: 1A, L:3748, l:3753, H:3756, B:008, PT:028C, BT:030C, PV:105083, M:Bike On 03963 12/05/2025 09:30:32 SOC:30525,83405,35203,114800,70,64,64,7 03964 12/05/2025 09:31:32 Discharge level 035 AH, SOC: 64%, I: 19A, L:3728, l:3742, H:3739, B:011, PT:028C, BT:030C, PV:104583, M:Bike On 03965 12/05/2025 09:31:32 SOC:30576,83511,35254,114800,70,63,64,20 03966 12/05/2025 09:32:32 Discharge level 035 AH, SOC: 64%, I: 12A, L:3736, l:3747, H:3744, B:008, PT:028C, BT:028C, PV:104758, M:Bike On 03967 12/05/2025 09:32:32 SOC:30682,83441,35401,114800,70,63,64,16 03968 12/05/2025 09:33:32 Discharge level 035 AH, SOC: 64%, I: 18A, L:3731, l:3745, H:3740, B:009, PT:028C, BT:030C, PV:104611, M:Bike On 03969 12/05/2025 09:33:32 SOC:30754,83465,35494,114800,70,63,64,19 03970 12/05/2025 09:34:32 Discharge level 035 AH, SOC: 63%, I: 1A, L:3739, l:3751, H:3747, B:008, PT:028C, BT:030C, PV:104829, M:Bike On 03971 12/05/2025 09:34:32 SOC:30900,83325,35675,114800,69,64,63,16 03972 12/05/2025 09:35:32 Discharge level 035 AH, SOC: 63%, I: 1A, L:3739, l:3746, H:3747, B:008, PT:028C, BT:029C, PV:104835, M:Bike On 03973 12/05/2025 09:35:32 SOC:31006,83053,35864,114800,69,63,63,11 03974 12/05/2025 09:36:32 Discharge level 036 AH, SOC: 63%, I: 0A, L:3731, l:3745, H:3739, B:008, PT:028C, BT:029C, PV:104609, M:Bike On 03975 12/05/2025 09:36:32 SOC:31268,82802,36165,114800,69,63,63,19 03976 12/05/2025 09:37:32 Discharge level 037 AH, SOC: 61%, I: 0A, L:3703, l:3738, H:3713, B:010, PT:028C, BT:029C, PV:103862, M:Bike On 03977 12/05/2025 09:37:32 SOC:32217,81989,37130,114800,68,62,61,49 03978 12/05/2025 09:38:32 Discharge level 038 AH, SOC: 59%, I:162A, L:3515, l:3637, H:3562, B:047, PT:028C, BT:030C, PV: 99243, M:Bike On 03979 12/05/2025 09:38:32 SOC:33355,81032,38284,114800,67,48,59,179 03980 12/05/2025 09:38:32 Discharge cutback 88% 03981 12/05/2025 09:38:32 Discharge cutback 88% 03982 12/05/2025 09:38:32 Discharge cutback 88% 03983 12/05/2025 09:38:32 756A 03984 12/05/2025 09:39:32 Discharge level 039 AH, SOC: 58%, I: 1A, L:3687, l:3733, H:3698, B:011, PT:028C, BT:030C, PV:103455, M:Bike On 03985 12/05/2025 09:39:32 SOC:34135,80214,39170,114800,66,61,58,67 03986 12/05/2025 09:39:32 Discharge cutback 85% 03987 12/05/2025 09:39:32 736A 03988 12/05/2025 09:40:32 Discharge level 040 AH, SOC: 56%, I:440A, L:3241, l:3487, H:3339, B:098, PT:029C, BT:030C, PV: 92421, M:Bike On 03989 12/05/2025 09:40:32 SOC:35203,78867,40391,114800,65,10,56,367 03990 12/05/2025 09:40:32 Discharge cutback 76% 03991 12/05/2025 09:40:32 651A 03992 12/05/2025 09:41:32 Discharge level 041 AH, SOC: 54%, I: 1A, L:3642, l:3698, H:3660, B:018, PT:029C, BT:029C, PV:102328, M:Bike On 03993 12/05/2025 09:41:32 SOC:36409,77786,41644,114800,64,57,54,84 03994 12/05/2025 09:41:32 Discharge cutback 68% 03995 12/05/2025 09:41:32 584A 03996 12/05/2025 09:42:32 Discharge level 042 AH, SOC: 52%, I: 68A, L:3566, l:3653, H:3598, B:032, PT:029C, BT:029C, PV:100455, M:Bike On 03997 12/05/2025 09:42:32 SOC:37586,77253,42840,114800,63,50,52,132 03998 12/05/2025 09:42:32 Discharge cutback 80% 03999 12/05/2025 09:42:32 692A 04000 12/05/2025 09:43:32 Discharge level 045 AH, SOC: 48%, I:110A, L:3488, l:3616, H:3532, B:044, PT:030C, BT:029C, PV: 98496, M:Bike On 04001 12/05/2025 09:43:32 SOC:39799,75442,45073,114800,61,43,48,205 04002 12/05/2025 09:43:32 Discharge cutback 58% 04003 12/05/2025 09:43:32 496A 04004 12/05/2025 09:44:32 Discharge level 046 AH, SOC: 46%, I: 1A, L:3584, l:3652, H:3610, B:026, PT:030C, BT:029C, PV:100886, M:Bike On 04005 12/05/2025 09:44:32 SOC:40936,74832,46332,114800,60,50,46,110 04006 12/05/2025 09:44:32 Discharge cutback 68% 04007 12/05/2025 09:44:32 584A 04008 12/05/2025 09:45:32 Discharge level 047 AH, SOC: 45%, I: 1A, L:3595, l:3652, H:3618, B:023, PT:030C, BT:029C, PV:101147, M:Bike On 04009 12/05/2025 09:45:32 SOC:41848,74808,47311,114800,59,50,45,93 04010 12/05/2025 09:45:32 Discharge cutback 73% 04011 12/05/2025 09:45:32 631A 04012 12/05/2025 09:46:32 Discharge level 047 AH, SOC: 44%, I: 0A, L:3611, l:3644, H:3632, B:021, PT:030C, BT:028C, PV:101546, M:Bike On 04013 12/05/2025 09:46:32 SOC:42143,75107,47804,114800,59,49,44,53 04014 12/05/2025 09:46:32 Discharge cutback 81% 04015 12/05/2025 09:46:32 695A 04016 12/05/2025 09:47:32 Discharge level 048 AH, SOC: 44%, I:-14A, L:3642, l:3660, H:3654, B:012, PT:030C, BT:029C, PV:102238, M:Bike On 04017 12/05/2025 09:47:32 SOC:42113,74622,48303,114800,58,51,44,30 04018 12/05/2025 09:47:32 Discharge cutback 81% 04019 12/05/2025 09:47:32 695A 04020 12/05/2025 09:48:32 Discharge level 048 AH, SOC: 44%, I:-22A, L:3646, l:3664, H:3657, B:011, PT:030C, BT:028C, PV:102334, M:Bike On 04021 12/05/2025 09:48:32 SOC:42095,74243,48760,114800,58,52,44,29 04022 12/05/2025 09:48:32 Discharge cutback 79% 04023 12/05/2025 09:48:32 682A 04024 12/05/2025 09:49:32 Discharge level 049 AH, SOC: 44%, I:-25A, L:3647, l:3662, H:3658, B:011, PT:030C, BT:029C, PV:102350, M:Bike On 04025 12/05/2025 09:49:32 SOC:42100,74455,49067,114800,58,52,44,25 04026 12/05/2025 09:49:32 Discharge cutback 80% 04027 12/05/2025 09:49:32 692A 04028 12/05/2025 09:50:32 Discharge level 049 AH, SOC: 44%, I: 0A, L:3630, l:3649, H:3645, B:015, PT:030C, BT:029C, PV:101961, M:Bike On 04029 12/05/2025 09:50:32 SOC:42042,74675,49317,114800,58,50,44,31 04030 12/05/2025 09:50:32 Discharge cutback 83% 04031 12/05/2025 09:50:32 715A 04032 12/05/2025 09:51:32 Discharge level 050 AH, SOC: 43%, I: 0A, L:3610, l:3646, H:3626, B:016, PT:030C, BT:029C, PV:101420, M:Bike On 04033 12/05/2025 09:51:32 SOC:42608,74368,50120,114800,57,49,43,58 04034 12/05/2025 09:51:32 Discharge cutback 74% 04035 12/05/2025 09:51:32 638A 04036 12/05/2025 09:52:32 Discharge level 050 AH, SOC: 43%, I: 0A, L:3611, l:3638, H:3628, B:017, PT:030C, BT:029C, PV:101486, M:Bike On 04037 12/05/2025 09:52:32 SOC:42776,74253,50585,114800,56,48,43,44 04038 12/05/2025 09:52:32 Discharge cutback 79% 04039 12/05/2025 09:52:32 678A 04040 12/05/2025 09:53:32 Discharge level 050 AH, SOC: 43%, I: 99A, L:3529, l:3586, H:3568, B:039, PT:030C, BT:028C, PV: 99597, M:Bike On 04041 12/05/2025 09:53:32 SOC:42650,74109,50858,114800,56,38,43,93 04042 12/05/2025 09:53:32 Discharge cutback 81% 04043 12/05/2025 09:53:32 698A 04044 12/05/2025 09:54:32 Discharge level 051 AH, SOC: 43%, I: 0A, L:3620, l:3639, H:3635, B:015, PT:030C, BT:027C, PV:101684, M:Bike On 04045 12/05/2025 09:54:32 SOC:42731,74116,51213,114800,56,48,43,32 04046 12/05/2025 09:54:32 Discharge cutback 80% 04047 12/05/2025 09:54:32 688A 04048 12/05/2025 09:55:32 Discharge level 051 AH, SOC: 43%, I: 0A, L:3614, l:3635, H:3630, B:016, PT:030C, BT:028C, PV:101550, M:Bike On 04049 12/05/2025 09:55:32 SOC:42784,73863,51602,114800,56,47,43,35 04050 12/05/2025 09:55:32 Discharge cutback 79% 04051 12/05/2025 09:55:32 678A 04052 12/05/2025 09:56:32 Discharge level 051 AH, SOC: 43%, I:110A, L:3516, l:3579, H:3557, B:041, PT:030C, BT:028C, PV: 99264, M:Bike On 04053 12/05/2025 09:56:32 SOC:42774,73780,51900,114800,55,36,43,101 04054 12/05/2025 09:56:32 Discharge cutback 80% 04055 12/05/2025 09:56:32 685A 04056 12/05/2025 09:57:32 Discharge level 053 AH, SOC: 40%, I: 0A, L:3566, l:3614, H:3592, B:026, PT:030C, BT:028C, PV:100397, M:Bike On 04057 12/05/2025 09:57:32 SOC:44004,73257,53146,114800,54,43,40,78 04058 12/05/2025 09:57:32 Discharge cutback 71% 04059 12/05/2025 09:57:32 607A 04060 12/05/2025 09:58:32 Discharge level 053 AH, SOC: 40%, I: 0A, L:3597, l:3623, H:3615, B:018, PT:030C, BT:027C, PV:101108, M:Bike On 04061 12/05/2025 09:58:32 SOC:44399,72989,53780,114800,54,45,40,42 04062 12/05/2025 09:58:32 Discharge cutback 76% 04063 12/05/2025 09:58:32 651A 04064 12/05/2025 09:59:32 Discharge level 053 AH, SOC: 40%, I: 16A, L:3598, l:3620, H:3617, B:019, PT:030C, BT:028C, PV:101155, M:Bike On 04065 12/05/2025 09:59:32 SOC:44205,73322,53877,114800,54,45,40,35 04066 12/05/2025 09:59:32 Discharge cutback 80% 04067 12/05/2025 09:59:32 692A 04068 12/05/2025 10:00:32 Discharge level 054 AH, SOC: 41%, I: 0A, L:3614, l:3627, H:3629, B:015, PT:030C, BT:027C, PV:101526, M:Bike On 04069 12/05/2025 10:00:32 SOC:44079,73601,54035,114800,53,46,41,21 04070 12/05/2025 10:00:32 Discharge cutback 81% 04071 12/05/2025 10:00:32 695A 04072 12/05/2025 10:01:32 Discharge level 054 AH, SOC: 41%, I: 0A, L:3614, l:3627, H:3629, B:015, PT:030C, BT:028C, PV:101521, M:Bike On 04073 12/05/2025 10:01:32 SOC:43914,73589,54221,114800,53,46,41,21 04074 12/05/2025 10:01:32 Discharge cutback 80% 04075 12/05/2025 10:01:32 692A 04076 12/05/2025 10:02:32 Discharge level 054 AH, SOC: 41%, I:-15A, L:3631, l:3636, H:3643, B:012, PT:030C, BT:028C, PV:101911, M:Bike On 04077 12/05/2025 10:02:32 SOC:43822,73748,54408,114800,53,47,41,8 04078 12/05/2025 10:02:32 Discharge cutback 81% 04079 12/05/2025 10:02:32 698A 04080 12/05/2025 10:03:32 Discharge level 054 AH, SOC: 40%, I: 36A, L:3575, l:3612, H:3598, B:023, PT:030C, BT:028C, PV:100579, M:Bike On 04081 12/05/2025 10:03:32 SOC:44210,73629,54956,114800,53,42,40,57 04082 12/05/2025 10:03:32 Discharge cutback 76% 04083 12/05/2025 10:03:32 651A 04084 12/05/2025 10:04:32 Discharge level 055 AH, SOC: 39%, I: 72A, L:3523, l:3578, H:3560, B:037, PT:030C, BT:028C, PV: 99407, M:Bike On 04085 12/05/2025 10:04:32 SOC:44602,73034,55614,114800,52,35,39,86 04086 12/05/2025 10:04:32 Discharge cutback 74% 04087 12/05/2025 10:04:32 634A 04088 12/05/2025 10:05:32 Discharge level 056 AH, SOC: 38%, I: 0A, L:3590, l:3613, H:3609, B:019, PT:030C, BT:027C, PV:100931, M:Bike On 04089 12/05/2025 10:05:32 SOC:45059,72522,56288,114800,51,43,38,35 04090 12/05/2025 10:05:32 Discharge cutback 75% 04091 12/05/2025 10:05:32 644A 04092 12/05/2025 10:06:32 Discharge level 056 AH, SOC: 39%, I: 1A, L:3598, l:3614, H:3615, B:017, PT:030C, BT:027C, PV:101125, M:Bike On 04093 12/05/2025 10:06:32 SOC:45085,72757,56520,114800,51,43,39,25 04094 12/05/2025 10:06:32 Discharge cutback 78% 04095 12/05/2025 10:06:32 668A 04096 12/05/2025 10:07:32 Discharge level 056 AH, SOC: 39%, I: 0A, L:3591, l:3609, H:3610, B:019, PT:029C, BT:027C, PV:100967, M:Bike On 04097 12/05/2025 10:07:32 SOC:45051,72981,56711,114800,51,42,39,28 04098 12/05/2025 10:07:32 Discharge cutback 76% 04099 12/05/2025 10:07:32 658A 04100 12/05/2025 10:08:32 Discharge level 056 AH, SOC: 39%, I: 0A, L:3603, l:3615, H:3619, B:016, PT:029C, BT:026C, PV:101237, M:Bike On 04101 12/05/2025 10:08:32 SOC:45035,73287,56897,114800,51,44,39,18 04102 12/05/2025 10:08:32 Discharge cutback 79% 04103 12/05/2025 10:08:32 678A 04104 12/05/2025 10:09:32 Discharge level 056 AH, SOC: 40%, I:-21A, L:3626, l:3626, H:3639, B:013, PT:029C, BT:027C, PV:101803, M:Bike On 04105 12/05/2025 10:09:32 SOC:44739,73515,56923,114800,51,46,40,0 04106 12/05/2025 10:09:32 Discharge cutback 80% 04107 12/05/2025 10:09:33 692A 04108 12/05/2025 10:10:32 Discharge level 057 AH, SOC: 40%, I:-17A, L:3622, l:3626, H:3635, B:013, PT:029C, BT:027C, PV:101696, M:Bike On 04109 12/05/2025 10:10:32 SOC:44575,73457,57094,114800,51,46,40,6 04110 12/05/2025 10:10:32 Discharge cutback 78% 04111 12/05/2025 10:10:33 675A 04112 12/05/2025 10:11:32 Discharge level 057 AH, SOC: 40%, I: 0A, L:3605, l:3616, H:3620, B:015, PT:029C, BT:027C, PV:101274, M:Bike On 04113 12/05/2025 10:11:32 SOC:44517,73405,57308,114800,51,44,40,17 04114 12/05/2025 10:11:32 Discharge cutback 78% 04115 12/05/2025 10:11:33 671A 04116 12/05/2025 10:12:32 Discharge level 057 AH, SOC: 40%, I: 0A, L:3597, l:3615, H:3613, B:016, PT:029C, BT:027C, PV:101065, M:Bike On 04117 12/05/2025 10:12:32 SOC:44619,73170,57648,114800,50,44,40,28 04118 12/05/2025 10:12:32 Discharge cutback 74% 04119 12/05/2025 10:12:33 638A 04120 12/05/2025 10:13:32 Discharge level 057 AH, SOC: 39%, I: 0A, L:3600, l:3611, H:3616, B:016, PT:029C, BT:026C, PV:101162, M:Bike On 04121 12/05/2025 10:13:32 SOC:44674,73186,57896,114800,50,43,39,17 04122 12/05/2025 10:13:33 Discharge cutback 78% 04123 12/05/2025 10:13:33 668A 04124 12/05/2025 10:14:32 Discharge level 058 AH, SOC: 39%, I: 42A, L:3556, l:3588, H:3583, B:027, PT:029C, BT:026C, PV:100116, M:Bike On 04125 12/05/2025 10:14:32 SOC:44822,73200,58189,114800,50,38,39,48 04126 12/05/2025 10:14:33 Discharge cutback 77% 04127 12/05/2025 10:14:33 661A 04128 12/05/2025 10:15:32 Discharge level 058 AH, SOC: 39%, I: 49A, L:3546, l:3583, H:3575, B:029, PT:029C, BT:027C, PV: 99888, M:Bike On 04129 12/05/2025 10:15:32 SOC:44807,72922,58457,114800,50,37,39,55 04130 12/05/2025 10:15:33 Discharge cutback 73% 04131 12/05/2025 10:15:33 631A 04132 12/05/2025 10:16:32 Discharge level 058 AH, SOC: 39%, I: 0A, L:3600, l:3610, H:3616, B:016, PT:029C, BT:027C, PV:101145, M:Bike On 04133 12/05/2025 10:16:32 SOC:44732,72964,58595,114800,49,43,39,15 04134 12/05/2025 10:16:33 Discharge cutback 78% 04135 12/05/2025 10:16:33 675A 04136 12/05/2025 10:17:32 Discharge level 058 AH, SOC: 39%, I: 32A, L:3571, l:3593, H:3595, B:024, PT:029C, BT:027C, PV:100491, M:Bike On 04137 12/05/2025 10:17:33 SOC:44656,73068,58714,114800,49,39,39,33 04138 12/05/2025 10:17:33 Discharge cutback 79% 04139 12/05/2025 10:17:33 678A 04140 12/05/2025 10:18:32 Discharge level 058 AH, SOC: 39%, I: -3A, L:3603, l:3613, H:3618, B:015, PT:029C, BT:026C, PV:101204, M:Bike On 04141 12/05/2025 10:18:33 SOC:44619,72852,58936,114800,49,43,39,15 04142 12/05/2025 10:18:33 Discharge cutback 76% 04143 12/05/2025 10:18:33 658A 04144 12/05/2025 10:19:32 Discharge level 058 AH, SOC: 40%, I: 0A, L:3604, l:3610, H:3619, B:015, PT:029C, BT:026C, PV:101246, M:Bike On 04145 12/05/2025 10:19:33 SOC:44420,72887,58975,114800,49,43,40,9 04146 12/05/2025 10:19:33 Discharge cutback 80% 04147 12/05/2025 10:19:33 688A 04148 12/05/2025 10:20:20 Contactor was Opened Pack V: 101309mV, Switched V: 101257mV, Prechg Pct: 100%, Dischg Cur: 545mA 04149 12/05/2025 10:20:21 System Turned Off 04150 12/05/2025 10:20:21 DEBUG: CAN Link Is Down 04151 12/05/2025 10:20:21 DEBUG: Entered Idle State 04152 12/05/2025 10:20:27 Current Sensor Zeroed old: 2507mV, new: 2504mV, corrfact: 252 04153 12/05/2025 10:20:29 Discharge level 058 AH, SOC: 40%, I: 0A, L:3607, l:3611, H:3623, B:016, PT:028C, BT:026C, PV:101340, M:Idle 04154 12/05/2025 10:20:29 SOC:44195,72887,58975,114800,49,43,40,6 04155 12/05/2025 10:20:50 Voltage Across Contactor: 88403mV (Okay) 04156 12/05/2025 10:40:16 System Turned On 04157 12/05/2025 10:40:16 Rev:45,Build:2023-05-20_045619 958 banka 04158 12/05/2025 10:40:16 Pack:2019_monolith,Numbricks:4 04159 12/05/2025 10:40:16 DEBUG: Entered Running State 04160 12/05/2025 10:40:16 DEBUG: CAN NOT Receiving Syncs 04161 12/05/2025 10:40:16 DEBUG: CAN Link Is Up 04162 12/05/2025 10:40:17 DEBUG: Resetting CAN0 due to error passive mode 04163 12/05/2025 10:40:17 Discharge level 058 AH, SOC: 40%, I: 0A, L:3617, l:3621, H:3631, B:014, PT:027C, BT:026C, PV:101598, M:Bike On 04164 12/05/2025 10:40:17 SOC:44191,72887,58975,114800,49,45,40,6 04165 12/05/2025 10:40:17 Discharge cutback 83% 04166 12/05/2025 10:40:17 715A 04167 12/05/2025 10:40:20 DEBUG: CAN Receiving Syncs 04168 12/05/2025 10:40:25 Contactor drive turned on Pack V: 101590mV, Switched V: 89993mV, Duty Cycle: 39% 04169 12/05/2025 10:40:25 Contactor was Closed Pack V: 101590mV, Switched V: 89993mV, Prechg Pct: 89%, Dischg Cur: 545mA 04170 12/05/2025 10:41:17 Discharge level 058 AH, SOC: 40%, I: 0A, L:3617, l:3620, H:3631, B:014, PT:027C, BT:025C, PV:101584, M:Bike On 04171 12/05/2025 10:41:17 SOC:43817,72928,58976,114800,49,45,40,5 04172 12/05/2025 10:41:17 Discharge cutback 83% 04173 12/05/2025 10:41:17 715A 04174 12/05/2025 10:42:17 Discharge level 058 AH, SOC: 41%, I: 1A, L:3616, l:3619, H:3631, B:015, PT:027C, BT:026C, PV:101572, M:Bike On 04175 12/05/2025 10:42:17 SOC:43605,73285,58985,114800,49,45,41,4 04176 12/05/2025 10:42:17 Discharge cutback 83% 04177 12/05/2025 10:42:17 715A 04178 12/05/2025 10:43:17 Discharge level 059 AH, SOC: 41%, I: 1A, L:3611, l:3620, H:3626, B:015, PT:027C, BT:026C, PV:101430, M:Bike On 04179 12/05/2025 10:43:17 SOC:43648,73773,59104,114800,49,45,41,13 04180 12/05/2025 10:43:17 Discharge cutback 80% 04181 12/05/2025 10:43:17 685A 04182 12/05/2025 10:44:17 Discharge level 059 AH, SOC: 41%, I: 2A, L:3574, l:3591, H:3596, B:022, PT:027C, BT:026C, PV:100519, M:Bike On 04183 12/05/2025 10:44:17 SOC:43818,73810,59394,114800,49,39,41,24 04184 12/05/2025 10:44:17 Discharge cutback 77% 04185 12/05/2025 10:44:17 665A 04186 12/05/2025 10:45:17 Discharge level 059 AH, SOC: 41%, I: -6A, L:3609, l:3618, H:3623, B:014, PT:027C, BT:026C, PV:101354, M:Bike On 04187 12/05/2025 10:45:17 SOC:44005,73727,59695,114800,49,44,41,13 04188 12/05/2025 10:45:17 Discharge cutback 77% 04189 12/05/2025 10:45:17 665A 04190 12/05/2025 10:46:17 Discharge level 059 AH, SOC: 41%, I: 0A, L:3603, l:3611, H:3618, B:015, PT:027C, BT:026C, PV:101224, M:Bike On 04191 12/05/2025 10:46:17 SOC:44059,73969,59810,114800,48,43,41,11 04192 12/05/2025 10:46:17 Discharge cutback 79% 04193 12/05/2025 10:46:17 682A 04194 12/05/2025 10:47:17 Discharge level 059 AH, SOC: 41%, I: 1A, L:3600, l:3610, H:3616, B:016, PT:027C, BT:026C, PV:101139, M:Bike On 04195 12/05/2025 10:47:17 SOC:44207,74141,59997,114800,48,43,41,15 04196 12/05/2025 10:47:17 Discharge cutback 78% 04197 12/05/2025 10:47:17 671A 04198 12/05/2025 10:48:17 Discharge level 060 AH, SOC: 41%, I: 1A, L:3603, l:3609, H:3618, B:015, PT:027C, BT:026C, PV:101211, M:Bike On 04199 12/05/2025 10:48:17 SOC:44256,74398,60095,114800,48,43,41,9 04200 12/05/2025 10:48:17 Discharge cutback 80% 04201 12/05/2025 10:48:17 685A 04202 12/05/2025 10:48:56 Contactor was Opened Pack V: 101283mV, Switched V: 101218mV, Prechg Pct: 100%, Dischg Cur: 1182mA 04203 12/05/2025 10:48:57 System Turned Off 04204 12/05/2025 10:48:58 DEBUG: CAN Link Is Down 04205 12/05/2025 10:48:58 DEBUG: Entered Idle State 04206 12/05/2025 10:49:04 Current Sensor Zeroed old: 2504mV, new: 2506mV, corrfact: 250 04207 12/05/2025 10:49:05 Discharge level 060 AH, SOC: 41%, I: 0A, L:3606, l:3609, H:3621, B:015, PT:027C, BT:026C, PV:101310, M:Idle 04208 12/05/2025 10:49:05 SOC:44271,74694,60113,114800,48,43,41,5 04209 12/05/2025 10:49:26 Voltage Across Contactor: 88420mV (Okay) 04210 12/05/2025 11:17:42 System Turned On 04211 12/05/2025 11:17:42 Rev:45,Build:2023-05-20_045619 958 banka 04212 12/05/2025 11:17:42 Pack:2019_monolith,Numbricks:4 04213 12/05/2025 11:17:42 DEBUG: Entered Running State 04214 12/05/2025 11:17:42 DEBUG: CAN NOT Receiving Syncs 04215 12/05/2025 11:17:42 DEBUG: CAN Link Is Up 04216 12/05/2025 11:17:43 DEBUG: Resetting CAN0 due to error passive mode 04217 12/05/2025 11:17:43 Discharge level 060 AH, SOC: 41%, I: 0A, L:3615, l:3619, H:3629, B:014, PT:025C, BT:025C, PV:101535, M:Bike On 04218 12/05/2025 11:17:43 SOC:44268,74694,60113,114800,48,45,41,5 04219 12/05/2025 11:17:43 Discharge cutback 83% 04220 12/05/2025 11:17:43 712A 04221 12/05/2025 11:17:46 DEBUG: CAN Receiving Syncs 04222 12/05/2025 11:17:47 Contactor drive turned on Pack V: 101529mV, Switched V: 89009mV, Duty Cycle: 39% 04223 12/05/2025 11:17:47 Contactor was Closed Pack V: 101529mV, Switched V: 89009mV, Prechg Pct: 88%, Dischg Cur: 636mA 04224 12/05/2025 11:18:43 Discharge level 060 AH, SOC: 42%, I: 1A, L:3614, l:3617, H:3628, B:014, PT:025C, BT:025C, PV:101505, M:Bike On 04225 12/05/2025 11:18:43 SOC:44210,75229,60129,114800,48,44,42,4 04226 12/05/2025 11:18:43 Discharge cutback 83% 04227 12/05/2025 11:18:43 712A 04228 12/05/2025 11:19:43 Discharge level 060 AH, SOC: 42%, I:-18A, L:3626, l:3631, H:3637, B:011, PT:025C, BT:025C, PV:101780, M:Bike On 04229 12/05/2025 11:19:43 SOC:44369,75333,60353,114800,48,47,42,7 04230 12/05/2025 11:19:43 Discharge cutback 76% 04231 12/05/2025 11:19:43 658A 04232 12/05/2025 11:20:43 Discharge level 060 AH, SOC: 41%, I: 1A, L:3603, l:3613, H:3617, B:014, PT:025C, BT:025C, PV:101190, M:Bike On 04233 12/05/2025 11:20:43 SOC:44415,75096,60589,114800,48,43,41,15 04234 12/05/2025 11:20:43 Discharge cutback 77% 04235 12/05/2025 11:20:43 665A 04236 12/05/2025 11:21:43 Discharge level 060 AH, SOC: 41%, I: 0A, L:3584, l:3601, H:3602, B:018, PT:025C, BT:025C, PV:100729, M:Bike On 04237 12/05/2025 11:21:43 SOC:44762,74987,60950,114800,47,41,41,24 04238 12/05/2025 11:21:43 Discharge cutback 75% 04239 12/05/2025 11:21:43 644A 04240 12/05/2025 11:22:43 Discharge level 061 AH, SOC: 39%, I: 85A, L:3473, l:3551, H:3511, B:038, PT:025C, BT:025C, PV: 97951, M:Bike On 04241 12/05/2025 11:22:43 SOC:45684,73770,61903,114800,47,30,39,109 04242 12/05/2025 11:22:43 Discharge cutback 66% 04243 12/05/2025 11:22:43 570A 04244 12/05/2025 11:23:43 Discharge level 063 AH, SOC: 35%, I: 1A, L:3547, l:3592, H:3567, B:020, PT:025C, BT:025C, PV: 99740, M:Bike On 04245 12/05/2025 11:23:43 SOC:46879,72093,63104,114800,46,39,35,63 04246 12/05/2025 11:23:43 Discharge cutback 62% 04247 12/05/2025 11:23:43 533A 04248 12/05/2025 11:24:43 Discharge level 064 AH, SOC: 32%, I: 1A, L:3511, l:3580, H:3537, B:026, PT:026C, BT:025C, PV: 98846, M:Bike On 04249 12/05/2025 11:24:43 SOC:48006,70367,64339,114800,44,36,32,97 04250 12/05/2025 11:24:43 Discharge cutback 47% 04251 12/05/2025 11:24:43 401A 04252 12/05/2025 11:25:20 Discharged To Low 065 AH, SOC: 43%, L:3246, H:3327, B:081, PT:026C, BT:025C, PV: 92338 04253 12/05/2025 11:25:43 Discharge level 066 AH, SOC: 28%, I: 2A, L:3514, l:3577, H:3537, B:023, PT:026C, BT:025C, PV: 98877, M:Bike On 04254 12/05/2025 11:25:43 SOC:49664,68575,66021,114800,43,36,28,86 04255 12/05/2025 11:25:43 Discharge cutback 49% 04256 12/05/2025 11:25:43 418A 04257 12/05/2025 11:26:43 Discharge level 067 AH, SOC: 24%, I: 0A, L:3493, l:3568, H:3519, B:026, PT:026C, BT:025C, PV: 98346, M:Bike On 04258 12/05/2025 11:26:43 SOC:51326,67188,67707,114800,42,33,24,97 04259 12/05/2025 11:26:43 Discharge cutback 47% 04260 12/05/2025 11:26:43 405A 04261 12/05/2025 11:27:43 Discharge level 068 AH, SOC: 24%, I: 80A, L:3445, l:3530, H:3484, B:039, PT:027C, BT:025C, PV: 97219, M:Bike On 04262 12/05/2025 11:27:43 SOC:51494,67497,68159,114800,41,20,24,110 04263 12/05/2025 11:27:43 Discharge cutback 61% 04264 12/05/2025 11:27:43 523A 04265 12/05/2025 11:28:43 Discharge level 068 AH, SOC: 24%, I: 1A, L:3532, l:3570, H:3552, B:020, PT:027C, BT:024C, PV: 99331, M:Bike On 04266 12/05/2025 11:28:43 SOC:51620,67503,68641,114800,41,34,24,50 04267 12/05/2025 11:28:43 Discharge cutback 63% 04268 12/05/2025 11:28:43 540A 04269 12/05/2025 11:29:43 Discharge level 069 AH, SOC: 23%, I: 91A, L:3414, l:3512, H:3460, B:046, PT:027C, BT:026C, PV: 96485, M:Bike On 04270 12/05/2025 11:29:43 SOC:52351,67441,69503,114800,40,15,23,125 04271 12/05/2025 11:29:43 Discharge cutback 53% 04272 12/05/2025 11:29:43 459A 04273 12/05/2025 11:30:43 Discharge level 069 AH, SOC: 23%, I: 48A, L:3486, l:3543, H:3515, B:029, PT:027C, BT:023C, PV: 98197, M:Bike On 04274 12/05/2025 11:30:43 SOC:52546,67954,69897,114800,40,25,23,73 04275 12/05/2025 11:30:43 Discharge cutback 62% 04276 12/05/2025 11:30:43 533A 04277 12/05/2025 11:31:43 Discharge level 070 AH, SOC: 23%, I: 33A, L:3505, l:3551, H:3528, B:023, PT:027C, BT:026C, PV: 98628, M:Bike On 04278 12/05/2025 11:31:43 SOC:52765,68274,70327,114800,39,28,23,59 04279 12/05/2025 11:31:43 Discharge cutback 64% 04280 12/05/2025 11:31:43 546A 04281 12/05/2025 11:32:43 Discharge level 070 AH, SOC: 24%, I: 1A, L:3542, l:3562, H:3560, B:018, PT:027C, BT:026C, PV: 99578, M:Bike On 04282 12/05/2025 11:32:43 SOC:52824,69446,70482,114800,39,32,24,26 04283 12/05/2025 11:32:43 Discharge cutback 67% 04284 12/05/2025 11:32:43 574A 04285 12/05/2025 11:33:43 Discharge level 070 AH, SOC: 26%, I: 0A, L:3550, l:3563, H:3567, B:017, PT:027C, BT:025C, PV: 99777, M:Bike On 04286 12/05/2025 11:33:43 SOC:52710,70511,70499,114800,39,32,26,18 04287 12/05/2025 11:33:43 Discharge cutback 69% 04288 12/05/2025 11:33:43 594A 04289 12/05/2025 11:34:43 Discharge level 070 AH, SOC: 27%, I: 1A, L:3553, l:3564, H:3571, B:018, PT:027C, BT:026C, PV: 99868, M:Bike On 04290 12/05/2025 11:34:43 SOC:52651,71570,70519,114800,39,32,27,14 04291 12/05/2025 11:34:43 Discharge cutback 70% 04292 12/05/2025 11:34:43 604A 04293 12/05/2025 11:34:45 Contactor was Opened Pack V: 99881mV, Switched V: 99800mV, Prechg Pct: 100%, Dischg Cur: 727mA 04294 12/05/2025 11:34:45 System Turned Off 04295 12/05/2025 11:34:46 DEBUG: CAN Link Is Down 04296 12/05/2025 11:34:46 DEBUG: Entered Idle State 04297 12/05/2025 11:34:52 Current Sensor Zeroed old: 2506mV, new: 2504mV, corrfact: 252 04298 12/05/2025 11:34:53 Discharge level 070 AH, SOC: 27%, I: 0A, L:3555, l:3565, H:3573, B:018, PT:027C, BT:026C, PV: 99911, M:Idle 04299 12/05/2025 11:34:53 SOC:52639,71585,70519,114800,39,33,27,13 04300 12/05/2025 11:35:06 System Turned On 04301 12/05/2025 11:35:06 Rev:45,Build:2023-05-20_045619 958 banka 04302 12/05/2025 11:35:06 Pack:2019_monolith,Numbricks:4 04303 12/05/2025 11:35:06 DEBUG: Entered Running State 04304 12/05/2025 11:35:06 DEBUG: CAN NOT Receiving Syncs 04305 12/05/2025 11:35:06 DEBUG: CAN Link Is Up 04306 12/05/2025 11:35:07 DEBUG: Resetting CAN0 due to error passive mode 04307 12/05/2025 11:35:07 Discharge level 070 AH, SOC: 27%, I: 0A, L:3555, l:3565, H:3573, B:018, PT:027C, BT:026C, PV: 99919, M:Bike On 04308 12/05/2025 11:35:07 SOC:52634,71585,70519,114800,39,33,27,13 04309 12/05/2025 11:35:07 Discharge cutback 71% 04310 12/05/2025 11:35:07 607A 04311 12/05/2025 11:35:10 DEBUG: CAN Receiving Syncs 04312 12/05/2025 11:35:10 Contactor drive turned on Pack V: 99920mV, Switched V: 87788mV, Duty Cycle: 40% 04313 12/05/2025 11:35:10 Contactor was Closed Pack V: 99920mV, Switched V: 87788mV, Prechg Pct: 88%, Dischg Cur: 636mA 04314 12/05/2025 11:35:12 DEBUG: Entered Charging State 04315 12/05/2025 11:35:12 DEBUG: CAN NOT Receiving Syncs 04316 12/05/2025 11:35:13 Discharge level 070 AH, SOC: 27%, I: 0A, L:3556, l:3566, H:3573, B:017, PT:027C, BT:025C, PV: 99927, M:Charge 04317 12/05/2025 11:35:13 SOC:52597,71591,70519,114800,39,33,27,13 04318 12/05/2025 11:35:14 DEBUG: CAN Receiving Syncs 04319 12/05/2025 11:45:13 Discharge level 068 AH, SOC: 35%, I:-12A, L:3609, l:3594, H:3622, B:013, PT:026C, BT:026C, PV:101304, M:Charge 04320 12/05/2025 11:45:13 SOC:40591,61723,68446,114800,41,40,35,-21 04321 12/05/2025 11:55:13 Discharge level 066 AH, SOC: 41%, I:-12A, L:3626, l:3610, H:3639, B:013, PT:026C, BT:026C, PV:101803, M:Charge 04322 12/05/2025 11:55:13 SOC:33813,57033,66374,114800,43,43,41,-23 04323 12/05/2025 12:05:13 Discharge level 064 AH, SOC: 46%, I:-12A, L:3639, l:3623, H:3650, B:011, PT:026C, BT:027C, PV:102132, M:Charge 04324 12/05/2025 12:05:13 SOC:30362,55630,64343,114800,44,45,46,-23 04325 12/05/2025 12:15:13 Discharge level 062 AH, SOC: 49%, I:-12A, L:3650, l:3634, H:3659, B:009, PT:026C, BT:027C, PV:102391, M:Charge 04326 12/05/2025 12:15:13 SOC:29045,56323,62351,114800,46,47,49,-22 04327 12/05/2025 12:25:13 Discharge level 060 AH, SOC: 51%, I:-12A, L:3661, l:3644, H:3669, B:008, PT:025C, BT:028C, PV:102669, M:Charge 04328 12/05/2025 12:25:13 SOC:28666,57969,60344,114800,48,49,51,-22 04329 12/05/2025 12:35:13 Discharge level 058 AH, SOC: 53%, I:-12A, L:3670, l:3653, H:3676, B:006, PT:025C, BT:027C, PV:102886, M:Charge 04330 12/05/2025 12:35:13 SOC:28713,60064,58311,114800,50,51,53,-23 04331 12/05/2025 12:45:13 Discharge level 056 AH, SOC: 54%, I:-11A, L:3680, l:3663, H:3685, B:005, PT:025C, BT:028C, PV:103136, M:Charge 04332 12/05/2025 12:45:13 SOC:28852,62230,56301,114800,51,52,54,-22 04333 12/05/2025 12:55:13 Discharge level 054 AH, SOC: 55%, I:-11A, L:3689, l:3673, H:3694, B:005, PT:025C, BT:027C, PV:103377, M:Charge 04334 12/05/2025 12:55:13 SOC:29088,64445,54338,114800,53,54,55,-22 04335 12/05/2025 13:05:20 Discharge level 052 AH, SOC: 57%, I:-11A, L:3699, l:3682, H:3704, B:005, PT:025C, BT:033C, PV:103656, M:Charge 04336 12/05/2025 13:05:20 SOC:29012,66376,52347,114800,55,55,57,-22 04337 12/05/2025 13:15:20 Discharge level 050 AH, SOC: 58%, I:-11A, L:3711, l:3694, H:3714, B:003, PT:025C, BT:036C, PV:103961, M:Charge 04338 12/05/2025 13:15:20 SOC:29000,68359,50369,114800,57,57,58,-22 04339 12/05/2025 13:25:20 Discharge level 048 AH, SOC: 60%, I:-12A, L:3722, l:3705, H:3727, B:005, PT:025C, BT:037C, PV:104303, M:Charge 04340 12/05/2025 13:25:20 SOC:28686,70061,48371,114800,58,58,60,-22 04341 12/05/2025 13:35:20 Discharge level 046 AH, SOC: 61%, I:-11A, L:3735, l:3718, H:3740, B:005, PT:025C, BT:039C, PV:104659, M:Charge 04342 12/05/2025 13:35:20 SOC:28169,71551,46381,114800,60,60,61,-22 04343 12/05/2025 13:45:20 Discharge level 044 AH, SOC: 63%, I:-12A, L:3748, l:3731, H:3754, B:006, PT:026C, BT:039C, PV:105038, M:Charge 04344 12/05/2025 13:45:20 SOC:27711,73054,44436,114800,62,61,63,-22 04345 12/05/2025 13:55:20 Discharge level 042 AH, SOC: 64%, I:-11A, L:3763, l:3746, H:3769, B:006, PT:026C, BT:039C, PV:105452, M:Charge 04346 12/05/2025 13:55:20 SOC:26847,74161,42480,114800,63,63,64,-22 04347 12/05/2025 14:05:20 Discharge level 040 AH, SOC: 66%, I:-11A, L:3779, l:3763, H:3786, B:007, PT:026C, BT:040C, PV:105897, M:Charge 04348 12/05/2025 14:05:20 SOC:25805,75051,40565,114800,65,65,66,-21 04349 12/05/2025 14:15:28 Discharge level 038 AH, SOC: 68%, I:-11A, L:3796, l:3780, H:3804, B:008, PT:026C, BT:041C, PV:106381, M:Charge 04350 12/05/2025 14:15:28 SOC:24744,75954,38618,114800,67,67,68,-21 04351 12/05/2025 14:25:28 Discharge level 036 AH, SOC: 70%, I:-11A, L:3814, l:3797, H:3823, B:009, PT:026C, BT:041C, PV:106891, M:Charge 04352 12/05/2025 14:25:28 SOC:23574,76704,36715,114800,69,69,70,-21 04353 12/05/2025 14:35:28 Discharge level 034 AH, SOC: 72%, I:-10A, L:3833, l:3817, H:3843, B:010, PT:026C, BT:041C, PV:107414, M:Charge 04354 12/05/2025 14:35:28 SOC:22302,77328,34836,114800,70,71,72,-20 04355 12/05/2025 14:45:28 Discharge level 032 AH, SOC: 74%, I:-11A, L:3854, l:3838, H:3863, B:009, PT:026C, BT:040C, PV:107998, M:Charge 04356 12/05/2025 14:45:28 SOC:20878,77800,32958,114800,72,73,74,-21 04357 12/05/2025 14:55:28 Discharge level 031 AH, SOC: 76%, I:-10A, L:3875, l:3859, H:3882, B:007, PT:026C, BT:039C, PV:108576, M:Charge 04358 12/05/2025 14:55:28 SOC:19300,78083,31113,114800,73,75,76,-20 04359 12/05/2025 15:05:28 Discharge level 029 AH, SOC: 78%, I:-10A, L:3898, l:3882, H:3902, B:004, PT:026C, BT:039C, PV:109184, M:Charge 04360 12/05/2025 15:05:28 SOC:17688,78324,29277,114800,75,77,78,-20 04361 12/05/2025 15:15:28 Discharge level 027 AH, SOC: 80%, I:-11A, L:3920, l:3904, H:3922, B:002, PT:026C, BT:036C, PV:109796, M:Charge 04362 12/05/2025 15:15:28 SOC:16097,78581,27445,114800,77,80,80,-21 04363 12/05/2025 15:25:36 Discharge level 025 AH, SOC: 82%, I:-11A, L:3939, l:3923, H:3942, B:003, PT:026C, BT:037C, PV:110338, M:Charge 04364 12/05/2025 15:25:36 SOC:14632,78999,25580,114800,78,81,82,-21 04365 12/05/2025 15:35:36 Discharge level 023 AH, SOC: 84%, I:-10A, L:3958, l:3943, H:3961, B:003, PT:026C, BT:038C, PV:110885, M:Charge 04366 12/05/2025 15:35:36 SOC:13276,79495,23744,114800,80,83,84,-20 04367 12/05/2025 15:45:36 Discharge level 021 AH, SOC: 86%, I:-10A, L:3977, l:3962, H:3979, B:002, PT:026C, BT:036C, PV:111391, M:Charge 04368 12/05/2025 15:45:36 SOC:11993,80049,21925,114800,81,85,86,-20 04369 12/05/2025 15:55:36 Discharge level 020 AH, SOC: 87%, I:-10A, L:3994, l:3979, H:3998, B:004, PT:026C, BT:033C, PV:111890, M:Charge 04370 12/05/2025 15:55:36 SOC:10835,80688,20147,114800,83,86,87,-20 04371 12/05/2025 16:05:36 Discharge level 018 AH, SOC: 89%, I:-10A, L:4013, l:3999, H:4016, B:003, PT:025C, BT:032C, PV:112404, M:Charge 04372 12/05/2025 16:05:36 SOC:9495,81145,18368,114800,84,88,89,-19 04373 12/05/2025 16:12:02 Charged To Full 017 AH, SOC: 90%, L:4025, H:4027, B:002, PT:025C, BT:031C, PV:112738 04374 12/05/2025 16:12:02 SOC adjusted for voltage old: 8670085uAH (soc:90%), new: 8146013uAH (soc:90%), low cell: 4025 mV 04375 12/05/2025 16:15:36 Discharge level 010 AH, SOC: 91%, I:-11A, L:4032, l:4017, H:4034, B:002, PT:025C, BT:030C, PV:112918, M:Charge 04376 12/05/2025 16:15:36 SOC:7955,81903,10852,114800,91,90,91,-20 04377 12/05/2025 16:25:36 Discharge level 009 AH, SOC: 92%, I:-10A, L:4050, l:4036, H:4052, B:002, PT:025C, BT:030C, PV:113430, M:Charge 04378 12/05/2025 16:25:36 SOC:6921,82654,9084,114800,93,91,92,-20 04379 12/05/2025 16:35:44 Discharge level 007 AH, SOC: 94%, I:-10A, L:4069, l:4055, H:4072, B:003, PT:025C, BT:030C, PV:113970, M:Charge 04380 12/05/2025 16:35:44 SOC:5419,82942,7313,114800,94,93,94,-20 04381 12/05/2025 16:45:44 Discharge level 005 AH, SOC: 96%, I:-10A, L:4088, l:4074, H:4091, B:003, PT:025C, BT:031C, PV:114504, M:Charge 04382 12/05/2025 16:45:44 SOC:3900,83216,5537,114800,96,95,96,-20 04383 12/05/2025 17:32:24 DEBUG: CAN Link Is Down 04384 12/05/2025 17:32:28 Contactor was Opened Pack V: 116072mV, Switched V: 116066mV, Prechg Pct: 100%, Dischg Cur: 545mA 04385 12/05/2025 17:32:28 DEBUG: CAN Link Is Up 04386 12/05/2025 17:32:31 System Turned Off 04387 12/05/2025 17:32:31 DEBUG: CAN Link Is Down 04388 12/05/2025 17:32:32 DEBUG: Entered Idle State 04389 12/05/2025 17:32:38 Discharge level 000 AH, SOC:100%, I: 0A, L:4147, l:4144, H:4151, B:004, PT:025C, BT:036C, PV:116022, M:Idle 04390 12/05/2025 17:32:38 SOC:0,83787,0,114800,100,100,100,-4 04391 12/05/2025 17:32:58 Voltage Across Contactor: 103150mV (Okay) 04392 12/06/2025 03:39:20 System Turned On 04393 12/06/2025 03:39:20 Rev:45,Build:2023-05-20_045619 958 banka 04394 12/06/2025 03:39:20 Pack:2019_monolith,Numbricks:4 04395 12/06/2025 03:39:20 DEBUG: Entered Charging State 04396 12/06/2025 03:39:20 DEBUG: CAN NOT Receiving Syncs 04397 12/06/2025 03:39:20 DEBUG: CAN Link Is Up 04398 12/06/2025 03:39:20 DEBUG: Entered Running State 04399 09/24/1981 15:02:01  04400 12/06/2025 03:45:21 Discharge level 001 AH, SOC: 99%, I: 1A, L:4089, l:4095, H:4093, B:004, PT:017C, BT:022C, PV:114581, M:Bike On 04401 12/06/2025 03:45:21 SOC:1329,80862,1127,114800,100,97,99,5 04402 12/06/2025 03:46:21 Discharge level 001 AH, SOC: 99%, I: 0A, L:4083, l:4091, H:4088, B:005, PT:017C, BT:021C, PV:114437, M:Bike On 04403 12/06/2025 03:46:21 SOC:1516,80277,1319,114800,99,97,99,8 04404 12/06/2025 03:47:21 Discharge level 001 AH, SOC: 98%, I: 79A, L:3884, l:3973, H:3918, B:034, PT:017C, BT:021C, PV:109249, M:Bike On 04405 12/06/2025 03:47:21 SOC:1917,79362,1704,114800,99,86,98,86 04406 12/06/2025 03:48:21 Discharge level 002 AH, SOC: 97%, I:-41A, L:4090, l:4141, H:4097, B:007, PT:017C, BT:022C, PV:114604, M:Bike On 04407 12/06/2025 03:48:21 SOC:2786,77851,2602,114800,98,100,97,49 04408 12/06/2025 03:48:21 Discharge cutback 83% 04409 12/06/2025 03:48:21 Discharge cutback 83% 04410 12/06/2025 03:48:21 Discharge cutback 83% 04411 12/06/2025 03:48:22 715A 04412 12/06/2025 03:49:21 Discharge level 003 AH, SOC: 96%, I:201A, L:3622, l:3841, H:3687, B:065, PT:018C, BT:022C, PV:102362, M:Bike On 04413 12/06/2025 03:49:21 SOC:3780,76188,3620,114800,97,73,96,225 04414 12/06/2025 03:50:21 Discharge level 005 AH, SOC: 93%, I: 0A, L:3764, l:3880, H:3802, B:038, PT:019C, BT:022C, PV:106016, M:Bike On 04415 12/06/2025 03:50:21 SOC:5247,74122,5205,114800,96,76,93,118 04416 12/06/2025 03:51:21 Discharge level 006 AH, SOC: 92%, I: 1A, L:3816, l:3915, H:3849, B:033, PT:020C, BT:022C, PV:107379, M:Bike On 04417 12/06/2025 03:51:21 SOC:6425,72472,6467,114800,95,80,92,107 04418 12/06/2025 03:52:21 Discharge level 007 AH, SOC: 90%, I:-30A, L:3984, l:4061, H:3993, B:009, PT:021C, BT:023C, PV:111730, M:Bike On 04419 12/06/2025 03:52:21 SOC:7157,71278,7245,114800,94,94,90,88 04420 12/06/2025 03:52:22 Discharge cutback 84% 04421 12/06/2025 03:52:22 722A 04422 12/06/2025 03:53:21 Discharge level 007 AH, SOC: 89%, I:-24A, L:3985, l:4026, H:3995, B:010, PT:021C, BT:022C, PV:111786, M:Bike On 04423 12/06/2025 03:53:21 SOC:7797,70391,7903,114800,94,90,89,46 04424 12/06/2025 03:54:21 Discharge level 008 AH, SOC: 89%, I: 68A, L:3855, l:3928, H:3888, B:033, PT:022C, BT:023C, PV:108512, M:Bike On 04425 12/06/2025 03:54:21 SOC:8237,69826,8345,114800,93,82,89,89 04426 12/06/2025 03:55:21 Discharge level 009 AH, SOC: 87%, I:178A, L:3680, l:3832, H:3739, B:059, PT:022C, BT:023C, PV:104017, M:Bike On 04427 12/06/2025 03:55:22 SOC:8995,68939,9156,114800,93,72,87,183 04428 12/06/2025 03:56:21 Discharge level 010 AH, SOC: 85%, I: 1A, L:3891, l:3972, H:3910, B:019, PT:023C, BT:022C, PV:109312, M:Bike On 04429 12/06/2025 03:56:22 SOC:10538,67494,10776,1148JA 04430 12/06/2025 04:03:22 SOC:16478,63013,17921,114800,85,72,74,130 04431 12/06/2025 04:04:22 Discharge level 018 AH, SOC: 74%, I: 40A, L:3799, l:3861, H:3827, B:028, PT:026C, BT:025C, PV:106923, M:Bike On 04432 12/06/2025 04:04:22 SOC:16918,63089,18500,114800,84,75,74,82 04433 12/06/2025 04:05:22 Discharge level 019 AH, SOC: 72%, I: 1A, L:3829, l:3890, H:3846, B:017, PT:027C, BT:025C, PV:107564, M:Bike On 04434 12/06/2025 04:05:22 SOC:17741,63180,19370,114800,84,78,72,80 04435 12/06/2025 04:06:22 Discharge level 020 AH, SOC: 70%, I:515A, L:3260, l:3628, H:3384, B:124, PT:027C, BT:026C, PV: 93450, M:Bike On 04436 12/06/2025 04:06:22 SOC:18939,63001,20632,114800,83,44,70,482 04437 12/06/2025 04:06:22 Discharge cutback 75% 04438 12/06/2025 04:06:22 641A 04439 12/06/2025 04:07:22 Discharge level 021 AH, SOC: 70%, I:-14A, L:3833, l:3868, H:3848, B:015, PT:027C, BT:025C, PV:107647, M:Bike On 04440 12/06/2025 04:07:22 SOC:19078,62915,21101,114800,82,76,70,46 04441 12/06/2025 04:08:22 Discharge level 021 AH, SOC: 70%, I: 0A, L:3827, l:3855, H:3843, B:016, PT:028C, BT:026C, PV:107493, M:Bike On 04442 12/06/2025 04:08:22 SOC:19309,63269,21478,114800,82,75,70,38 04443 12/06/2025 04:09:22 Discharge level 021 AH, SOC: 70%, I: 53A, L:3780, l:3825, H:3806, B:026, PT:028C, BT:025C, PV:106352, M:Bike On 04444 12/06/2025 04:09:22 SOC:19193,63696,21562,114800,82,72,70,62 04445 12/06/2025 04:10:22 Discharge level 022 AH, SOC: 70%, I: 1A, L:3827, l:3849, H:3841, B:014, PT:028C, BT:026C, PV:107433, M:Bike On 04446 12/06/2025 04:10:22 SOC:19729,63800,22260,114800,81,74,70,31 04447 12/06/2025 04:11:22 Discharge level 022 AH, SOC: 70%, I: 1A, L:3828, l:3850, H:3842, B:014, PT:028C, BT:026C, PV:107480, M:Bike On 04448 12/06/2025 04:11:22 SOC:19811,64295,22459,114800,81,74,70,30 04449 12/06/2025 04:12:22 Discharge level 022 AH, SOC: 70%, I: 28A, L:3814, l:3838, H:3830, B:016, PT:028C, BT:025C, PV:107123, M:Bike On 04450 12/06/2025 04:12:22 SOC:19506,64453,22466,114800,81,73,70,33 04451 12/06/2025 04:13:22 Discharge level 022 AH, SOC: 70%, I: 0A, L:3827, l:3846, H:3841, B:014, PT:028C, BT:027C, PV:107430, M:Bike On 04452 12/06/2025 04:13:22 SOC:19617,64641,22772,114800,81,74,70,26 04453 12/06/2025 04:14:22 Discharge level 022 AH, SOC: 70%, I: 1A, L:3836, l:3848, H:3848, B:012, PT:028C, BT:027C, PV:107641, M:Bike On 04454 12/06/2025 04:14:22 SOC:19597,64841,22962,114800,80,74,70,16 04455 12/06/2025 04:15:22 Discharge level 023 AH, SOC: 70%, I: 1A, L:3822, l:3843, H:3834, B:012, PT:028C, BT:028C, PV:107245, M:Bike On 04456 12/06/2025 04:15:22 SOC:19930,64986,23434,114800,80,73,70,28 04457 12/06/2025 04:16:22 Discharge level 023 AH, SOC: 70%, I: 1A, L:3829, l:3841, H:3840, B:011, PT:028C, BT:027C, PV:107422, M:Bike On 04458 12/06/2025 04:16:22 SOC:19991,65347,23594,114800,80,73,70,17 04459 12/06/2025 04:17:22 Discharge level 024 AH, SOC: 69%, I:-18A, L:3835, l:3852, H:3843, B:008, PT:028C, BT:027C, PV:107511, M:Bike On 04460 12/06/2025 04:17:22 SOC:20281,65417,24037,114800,80,74,69,23 04461 12/06/2025 04:18:22 Discharge level 024 AH, SOC: 69%, I: 1A, L:3821, l:3834, H:3832, B:011, PT:028C, BT:028C, PV:107190, M:Bike On 04462 12/06/2025 04:18:22 SOC:20327,65548,24266,114800,79,72,69,18 04463 12/06/2025 04:19:22 Discharge level 024 AH, SOC: 69%, I: 1A, L:3820, l:3831, H:3830, B:010, PT:028C, BT:028C, PV:107149, M:Bike On 04464 12/06/2025 04:19:22 SOC:20483,65656,24560,114800,79,72,69,15 04465 12/06/2025 04:19:25 Contactor was Opened Pack V: 107166mV, Switched V: 107126mV, Prechg Pct: 100%, Dischg Cur: 909mA 04466 12/06/2025 04:19:25 System Turned Off 04467 12/06/2025 04:19:26 DEBUG: CAN Link Is Down 04468 12/06/2025 04:19:26 DEBUG: Entered Idle State 04469 12/06/2025 04:19:33 Discharge level 024 AH, SOC: 69%, I: 0A, L:3824, l:3834, H:3833, B:009, PT:028C, BT:026C, PV:107221, M:Idle 04470 12/06/2025 04:19:33 SOC:20471,65666,24561,114800,79,72,69,14 04471 12/06/2025 04:19:55 Voltage Across Contactor: 94462mV (Okay) 04472 12/06/2025 06:26:06 System Turned On 04473 12/06/2025 06:26:06 Rev:45,Build:2023-05-20_045619 958 banka 04474 12/06/2025 06:26:06 Pack:2019_monolith,Numbricks:4 04475 12/06/2025 06:26:06 DEBUG: Entered Running State 04476 12/06/2025 06:26:06 DEBUG: CAN NOT Receiving Syncs 04477 12/06/2025 06:26:06 DEBUG: CAN Link Is Up 04478 12/06/2025 06:26:07 DEBUG: Resetting CAN0 due to error passive mode 04479 12/06/2025 06:26:07 Discharge level 024 AH, SOC: 69%, I: 0A, L:3855, l:3865, H:3862, B:007, PT:026C, BT:029C, PV:108035, M:Bike On 04480 12/06/2025 06:26:07 SOC:20466,65666,24561,114800,79,76,69,14 04481 12/06/2025 06:26:10 DEBUG: CAN Receiving Syncs 04482 12/06/2025 06:26:15 Contactor drive turned on Pack V: 108014mV, Switched V: 95035mV, Duty Cycle: 37% 04483 12/06/2025 06:26:15 Contactor was Closed Pack V: 108014mV, Switched V: 95035mV, Prechg Pct: 88%, Dischg Cur: 636mA 04484 12/06/2025 06:27:07 Discharge level 024 AH, SOC: 70%, I: 1A, L:3854, l:3861, H:3860, B:006, PT:025C, BT:028C, PV:107990, M:Bike On 04485 12/06/2025 06:27:07 SOC:20427,66593,24581,114800,79,75,70,9 04486 12/06/2025 06:28:07 Discharge level 024 AH, SOC: 70%, I: 1A, L:3853, l:3858, H:3859, B:006, PT:025C, BT:029C, PV:107977, M:Bike On 04487 12/06/2025 06:28:07 SOC:20419,67516,24603,114800,79,75,70,7 04488 12/06/2025 06:29:07 Discharge level 024 AH, SOC: 71%, I: 1A, L:3853, l:3857, H:3859, B:006, PT:025C, BT:029C, PV:107965, M:Bike On 04489 12/06/2025 06:29:07 SOC:20414,68385,24625,114800,79,75,71,5 04490 12/06/2025 06:30:07 Discharge level 024 AH, SOC: 71%, I: 1A, L:3847, l:3855, H:3854, B:007, PT:025C, BT:029C, PV:107817, M:Bike On 04491 12/06/2025 06:30:07 SOC:20455,69127,24700,114800,79,75,71,11 04492 12/06/2025 06:31:07 Discharge level 024 AH, SOC: 71%, I: 1A, L:3843, l:3852, H:3850, B:007, PT:025C, BT:029C, PV:107716, M:Bike On 04493 12/06/2025 06:31:07 SOC:20476,69603,24823,114800,79,74,71,12 04494 12/06/2025 06:32:07 Discharge level 024 AH, SOC: 71%, I: 1A, L:3829, l:3840, H:3838, B:009, PT:025C, BT:029C, PV:107357, M:Bike On 04495 12/06/2025 06:32:07 SOC:20531,69924,24984,114800,79,73,71,14 04496 12/06/2025 06:33:07 Discharge level 025 AH, SOC: 71%, I: 12A, L:3832, l:3844, H:3839, B:007, PT:025C, BT:029C, PV:107411, M:Bike On 04497 12/06/2025 06:33:07 SOC:20575,70292,25103,114800,79,73,71,15 04498 12/06/2025 06:34:07 Discharge level 025 AH, SOC: 71%, I:-10A, L:3847, l:3848, H:3854, B:007, PT:025C, BT:029C, PV:107806, M:Bike On 04499 12/06/2025 06:34:07 SOC:20560,70521,25204,114800,79,74,71,1 04500 12/06/2025 06:35:07 Discharge level 025 AH, SOC: 71%, I: 2A, L:3829, l:3841, H:3837, B:008, PT:025C, BT:028C, PV:107329, M:Bike On 04501 12/06/2025 06:35:07 SOC:20692,70701,25395,114800,78,73,71,15 04502 12/06/2025 06:36:07 Discharge level 025 AH, SOC: 71%, I: 1A, L:3832, l:3837, H:3840, B:008, PT:025C, BT:029C, PV:107416, M:Bike On 04503 12/06/2025 06:36:07 SOC:20661,70851,25477,114800,78,73,71,7 04504 12/06/2025 06:37:07 Discharge level 025 AH, SOC: 71%, I: 1A, L:3824, l:3832, H:3832, B:008, PT:025C, BT:028C, PV:107197, M:Bike On 04505 12/06/2025 06:37:07 SOC:20897,70923,25758,114800,78,72,71,11 04506 12/06/2025 06:38:07 Discharge level 026 AH, SOC: 69%, I:124A, L:3626, l:3748, H:3655, B:029, PT:026C, BT:029C, PV:101961, M:Bike On 04507 12/06/2025 06:38:07 SOC:21922,70294,26856,114800,77,63,69,161 04508 12/06/2025 06:39:07 Discharge level 028 AH, SOC: 67%, I: 58A, L:3698, l:3774, H:3714, B:016, PT:026C, BT:029C, PV:103784, M:Bike On 04509 12/06/2025 06:39:07 SOC:23080,69701,28096,114800,76,66,67,101 04510 12/06/2025 06:40:07 Discharge level 028 AH, SOC: 66%, I: 2A, L:3758, l:3797, H:3766, B:008, PT:026C, BT:029C, PV:105353, M:Bike On 04511 12/06/2025 06:40:07 SOC:23712,69654,28740,114800,75,69,66,52 04512 12/06/2025 06:41:07 Discharge level 029 AH, SOC: 66%, I: 83A, L:3669, l:3738, H:3692, B:023, PT:026C, BT:029C, PV:103114, M:Bike On 04513 12/06/2025 06:41:07 SOC:24272,69451,29401,114800,75,62,66,91 04514 12/06/2025 06:42:07 Discharge level 029 AH, SOC: 65%, I: 0A, L:3765, l:3785, H:3772, B:007, PT:026C, BT:029C, PV:105537, M:Bike On 04515 12/06/2025 06:42:07 SOC:24438,69537,29662,114800,75,67,65,27 04516 12/06/2025 06:43:07 Discharge level 029 AH, SOC: 66%, I:-14A, L:3792, l:3794, H:3797, B:005, PT:026C, BT:029C, PV:106253, M:Bike On 04517 12/06/2025 06:43:07 SOC:24298,69569,29702,114800,75,68,66,3 04518 12/06/2025 06:44:07 Discharge level 029 AH, SOC: 66%, I: 34A, L:3738, l:3765, H:3749, B:011, PT:026C, BT:029C, PV:104845, M:Bike On 04519 12/06/2025 06:44:07 SOC:23978,69395,29679,114800,75,65,66,36 04520 12/06/2025 06:45:07 Discharge level 029 AH, SOC: 66%, I: 0A, L:3782, l:3787, H:3787, B:005, PT:026C, BT:029C, PV:105973, M:Bike On 04521 12/06/2025 06:45:07 SOC:23855,69430,29716,114800,75,68,66,7 04522 12/06/2025 06:46:07 Discharge level 029 AH, SOC: 66%, I:-11A, L:3796, l:3793, H:3802, B:006, PT:026C, BT:029C, PV:106384, M:Bike On 04523 12/06/2025 06:46:07 SOC:23631,69370,29708,114800,75,68,66,-4 04524 12/06/2025 06:47:07 Discharge level 029 AH, SOC: 67%, I: 14A, L:3774, l:3781, H:3781, B:007, PT:026C, BT:029C, PV:105793, M:Bike On 04525 12/06/2025 06:47:07 SOC:23251,69184,29614,114800,75,67,67,9 04526 12/06/2025 06:48:07 Discharge level 029 AH, SOC: 66%, I: 42A, L:3718, l:3762, H:3730, B:012, PT:026C, BT:028C, PV:104300, M:Bike On 04527 12/06/2025 06:48:07 SOC:23561,69120,29974,114800,74,65,66,58 04528 12/06/2025 06:49:07 Discharge level 030 AH, SOC: 66%, I: 47A, L:3701, l:3752, H:3714, B:013, PT:026C, BT:028C, PV:103834, M:Bike On 04529 12/06/2025 06:49:07 SOC:24110,68971,30537,114800,74,64,66,67 04530 12/06/2025 06:50:07 Discharge level 030 AH, SOC: 65%, I: 1A, L:3756, l:3772, H:3763, B:007, PT:026C, BT:029C, PV:105280, M:Bike On 04531 12/06/2025 06:50:07 SOC:24507,68973,30939,114800,74,66,65,21 04532 12/06/2025 06:51:07 Discharge level 030 AH, SOC: 65%, I:-17A, L:3782, l:3779, H:3788, B:006, PT:026C, BT:028C, PV:105987, M:Bike On 04533 12/06/2025 06:51:07 SOC:24236,68815,30884,114800,74,67,65,-4 04534 12/06/2025 06:52:07 Discharge level 030 AH, SOC: 66%, I: 0A, L:3774, l:3775, H:3780, B:006, PT:026C, BT:028C, PV:105761, M:Bike On 04535 12/06/2025 06:52:07 SOC:23995,68722,30822,114800,74,66,66,2 04536 12/06/2025 06:53:07 Discharge level 030 AH, SOC: 66%, I: 56A, L:3710, l:3745, H:3721, B:011, PT:026C, BT:029C, PV:104041, M:Bike On 04537 12/06/2025 06:53:07 SOC:24017,68729,30920,114800,74,63,66,46 04538 12/06/2025 06:54:07 Discharge level 031 AH, SOC: 65%, I: 0A, L:3756, l:3771, H:3762, B:006, PT:026C, BT:029C, PV:105259, M:Bike On 04539 12/06/2025 06:54:07 SOC:24443,68595,31375,114800,73,66,65,20 04540 12/06/2025 06:55:07 Discharge level 031 AH, SOC: 65%, I:-15A, L:3775, l:3777, H:3780, B:005, PT:026C, BT:029C, PV:105781, M:Bike On 04541 12/06/2025 06:55:07 SOC:24518,68567,31532,114800,73,67,65,3 04542 12/06/2025 06:56:07 Discharge level 031 AH, SOC: 65%, I: 1A, L:3759, l:3767, H:3765, B:006, PT:026C, BT:029C, PV:105355, M:Bike On 04543 12/06/2025 06:56:07 SOC:24563,68538,31657,114800,73,65,65,11 04544 12/06/2025 06:57:07 Discharge level 031 AH, SOC: 64%, I: -1A, L:3758, l:3765, H:3763, B:005, PT:026C, BT:028C, PV:105303, M:Bike On 04545 12/06/2025 06:57:07 SOC:24770,68308,31976,114800,73,65,64,9 04546 12/06/2025 06:58:07 Discharge level 032 AH, SOC: 64%, I: 0A, L:3746, l:3761, H:3752, B:006, PT:026C, BT:029C, PV:104979, M:Bike On 04547 12/06/2025 06:58:07 SOC:25069,68196,32326,114800,72,65,64,20 04548 12/06/2025 06:59:07 Discharge level 032 AH, SOC: 63%, I:139A, L:3588, l:3681, H:3620, B:032, PT:026C, BT:029C, PV:100986, M:Bike On 04549 12/06/2025 06:59:07 SOC:25437,68020,32755,114800,72,54,63,124 04550 12/06/2025 07:00:07 Discharge level 032 AH, SOC: 63%, I: 0A, L:3747, l:3756, H:3752, B:005, PT:026C, BT:028C, PV:105010, M:Bike On 04551 12/06/2025 07:00:07 SOC:25398,68045,32814,114800,72,64,63,12 04552 12/06/2025 07:01:07 Discharge level 032 AH, SOC: 63%, I: 1A, L:3751, l:3757, H:3756, B:005, PT:026C, BT:029C, PV:105109, M:Bike On 04553 12/06/2025 07:01:07 SOC:25366,68122,32838,114800,72,64,63,9 04554 12/06/2025 07:02:07 Discharge level 032 AH, SOC: 63%, I: 1A, L:3749, l:3756, H:3755, B:006, PT:026C, BT:029C, PV:105060, M:Bike On 04555 12/06/2025 07:02:07 SOC:25453,68221,32960,114800,72,64,63,10 04556 12/06/2025 07:03:07 Discharge level 033 AH, SOC: 63%, I: 11A, L:3733, l:3748, H:3739, B:006, PT:026C, BT:029C, PV:104632, M:Bike On 04557 12/06/2025 07:03:07 SOC:25535,68179,33134,114800,72,63,63,20 04558 12/06/2025 07:04:07 Discharge level 033 AH, SOC: 63%, I: 1A, L:3740, l:3750, H:3746, B:006, PT:026C, BT:029C, PV:104834, M:Bike On 04559 12/06/2025 07:04:07 SOC:25660,68053,33364,114800,71,63,63,13 04560 12/06/2025 07:05:07 Discharge level 033 AH, SOC: 62%, I: 23A, L:3703, l:3738, H:3713, B:010, PT:026C, BT:028C, PV:103829, M:Bike On 04561 12/06/2025 07:05:07 SOC:26099,67977,33810,114800,71,62,62,47 04562 12/06/2025 07:06:07 Discharge level 034 AH, SOC: 62%, I: 33A, L:3692, l:3725, H:3704, B:012, PT:026C, BT:028C, PV:103563, M:Bike On 04563 12/06/2025 07:06:07 SOC:26346,67936,34109,114800,71,60,62,45 04564 12/06/2025 07:07:07 Discharge level 034 AH, SOC: 61%, I: -1A, L:3732, l:3744, H:3736, B:004, PT:026C, BT:029C, PV:104575, M:Bike On 04565 12/06/2025 07:07:07 SOC:26644,68020,34414,114800,71,63,61,17 04566 12/06/2025 07:08:07 Discharge level 034 AH, SOC: 61%, I: 1A, L:3734, l:3742, H:3740, B:006, PT:026C, BT:029C, PV:104639, M:Bike On 04567 12/06/2025 07:08:07 SOC:26549,67983,34472,114800,70,63,61,11 04568 12/06/2025 07:09:07 Discharge level 034 AH, SOC: 62%, I: 28A, L:3705, l:3725, H:3715, B:010, PT:026C, BT:027C, PV:103895, M:Bike On 04569 12/06/2025 07:09:07 SOC:26446,67936,34525,114800,70,60,62,27 04570 12/06/2025 07:10:07 Discharge level 034 AH, SOC: 62%, I: 1A, L:3736, l:3742, H:3740, B:004, PT:026C, BT:028C, PV:104680, M:Bike On 04571 12/06/2025 07:10:07 SOC:26433,68049,34587,114800,70,62,62,8 04572 12/06/2025 07:11:07 Discharge level 035 AH, SOC: 61%, I: 54A, L:3649, l:3704, H:3665, B:016, PT:026C, BT:028C, PV:102437, M:Bike On 04573 12/06/2025 07:11:07 SOC:27018,67812,35197,114800,70,58,61,74 04574 12/06/2025 07:12:07 Discharge level 035 AH, SOC: 60%, I: 1A, L:3709, l:3730, H:3716, B:007, PT:026C, BT:028C, PV:103999, M:Bike On 04575 12/06/2025 07:12:07 SOC:27560,67611,35772,114800,69,61,60,28 04576 12/06/2025 07:13:07 Discharge level 035 AH, SOC: 60%, I: 1A, L:3720, l:3731, H:3725, B:005, PT:026C, BT:028C, PV:104241, M:Bike On 04577 12/06/2025 07:13:07 SOC:27542,67591,35878,114800,69,61,60,15 04578 12/06/2025 07:14:07 Discharge level 036 AH, SOC: 60%, I: 1A, L:3718, l:3731, H:3723, B:005, PT:026C, BT:027C, PV:104197, M:Bike On 04579 12/06/2025 07:14:07 SOC:27681,67700,36058,114800,69,61,60,17 04580 12/06/2025 07:15:07 Discharge level 036 AH, SOC: 60%, I: 1A, L:3723, l:3734, H:3727, B:004, PT:025C, BT:028C, PV:104326, M:Bike On 04581 12/06/2025 07:15:07 SOC:27675,67708,36164,114800,69,62,60,16 04582 12/06/2025 07:16:07 Discharge level 036 AH, SOC: 59%, I: 1A, L:3702, l:3722, H:3709, B:007, PT:025C, BT:028C, PV:103790, M:Bike On 04583 12/06/2025 07:16:07 SOC:28147,67567,36666,114800,69,60,59,27 04584 12/06/2025 07:17:07 Discharge level 037 AH, SOC: 58%, I: 1A, L:3700, l:3722, H:3707, B:007, PT:025C, BT:028C, PV:103730, M:Bike On 04585 12/06/2025 07:17:07 SOC:28420,67388,37039,114800,68,60,58,30 04586 12/06/2025 07:18:07 Discharge level 037 AH, SOC: 58%, I: 41A, L:3650, l:3693, H:3665, B:015, PT:025C, BT:028C, PV:102480, M:Bike On 04587 12/06/2025 07:18:07 SOC:28822,67289,37489,114800,68,56,58,58 04588 12/06/2025 07:19:07 Discharge level 038 AH, SOC: 57%, I: 99A, L:3585, l:3655, H:3610, B:025, PT:025C, BT:026C, PV:100793, M:Bike On 04589 12/06/2025 07:19:07 SOC:29320,67092,38042,114800,67,51,57,96 04590 12/06/2025 07:20:07 Discharge level 039 AH, SOC: 55%, I: 0A, L:3658, l:3707, H:3669, B:011, PT:026C, BT:028C, PV:102667, M:Bike On 04591 12/06/2025 07:20:08 SOC:30462,66247,39286,114800,66,58,55,67 04592 12/06/2025 07:20:08 Discharge cutback 84% 04593 12/06/2025 07:20:08 725A 04594 12/06/2025 07:21:07 Discharge level 040 AH, SOC: 52%, I: 1A, L:3632, l:3712, H:3646, B:014, PT:026C, BT:028C, PV:101991, M:Bike On 04595 12/06/2025 07:21:08 SOC:31559,65218,40573,114800,65,58,52,112 04596 12/06/2025 07:21:08 Discharge cutback 51% 04597 12/06/2025 07:21:08 435A 04598 12/06/2025 07:22:07 Discharge level 041 AH, SOC: 51%, I: 41A, L:3616, l:3664, H:3636, B:020, PT:026C, BT:028C, PV:101622, M:Bike On 04599 12/06/2025 07:22:08 SOC:31785,64866,41090,114800,65,52,51,68 04600 12/06/2025 07:22:08 Discharge cutback 83% 04601 12/06/2025 07:22:08 715A 04602 12/06/2025 07:23:08 Discharge level 042 AH, SOC: 49%, I:113A, L:3509, l:3622, H:3545, B:036, PT:026C, BT:028C, PV: 98878, M:Bike On 04603 12/06/2025 07:23:08 SOC:33000,64544,42336,114800,64,45,49,160 04604 12/06/2025 07:23:08 Discharge cutback 78% 04605 12/06/2025 07:23:08 675A 04606 12/06/2025 07:24:08 Discharge level 043 AH, SOC: 48%, I: 0A, L:3632, l:3678, H:3645, B:013, PT:027C, BT:027C, PV:101980, M:Bike On 04607 12/06/2025 07:24:08 SOC:33660,64489,43139,114800,63,54,48,65 04608 12/06/2025 07:24:08 Discharge cutback 81% 04609 12/06/2025 07:24:08 695A 04610 12/06/2025 07:25:08 Discharge level 045 AH, SOC: 44%, I:166A, L:3409, l:3581, H:3461, B:052, PT:027C, BT:028C, PV: 96328, M:Bike On 04611 12/06/2025 07:25:08 SOC:35720,63314,45281,114800,61,35,44,257 04612 12/06/2025 07:25:08 Discharge cutback 60% 04613 12/06/2025 07:25:08 519A 04614 12/06/2025 07:26:08 Discharge level 045 AH, SOC: 43%, I: 60A, L:3550, l:3626, H:3577, B:027, PT:027C, BT:028C, PV: 99916, M:Bike On 04615 12/06/2025 07:26:08 SOC:36259,63520,45998,114800,60,45,43,114 04616 12/06/2025 07:26:08 Discharge cutback 75% 04617 12/06/2025 07:26:08 648A 04618 12/06/2025 07:27:08 Discharge level 046 AH, SOC: 42%, I:191A, L:3442, l:3571, H:3489, B:047, PT:027C, BT:027C, PV: 97190, M:Bike On 04619 12/06/2025 07:27:08 SOC:37175,63883,46958,114800,60,33,42,193 04620 12/06/2025 07:27:08 Discharge cutback 75% 04621 12/06/2025 07:27:08 648A 04622 12/06/2025 07:28:08 Discharge level 048 AH, SOC: 40%, I: 1A, L:3589, l:3644, H:3607, B:018, PT:028C, BT:028C, PV:100849, M:Bike On 04623 12/06/2025 07:28:08 SOC:38422,63392,48394,114800,58,49,40,83 04624 12/06/2025 07:28:08 Discharge cutback 71% 04625 12/06/2025 07:28:08 614A 04626 12/06/2025 07:29:08 Discharge level 050 AH, SOC: 37%, I:-21A, L:3599, l:3649, H:3613, B:014, PT:028C, BT:028C, PV:101084, M:Bike On 04627 12/06/2025 07:29:08 SOC:39851,62647,50057,114800,57,50,37,78 04628 12/06/2025 07:29:08 Discharge cutback 66% 04629 12/06/2025 07:29:08 567A 04630 12/06/2025 07:30:08 Discharge level 051 AH, SOC: 36%, I:123A, L:3464, l:3567, H:3505, B:041, PT:028C, BT:028C, PV: 97742, M:Bike On 04631 12/06/2025 07:30:08 SOC:40610,62576,51119,114800,56,33,36,161 04632 12/06/2025 07:30:08 Discharge cutback 68% 04633 12/06/2025 07:30:08 587A 04634 12/06/2025 07:31:08 Discharge level 052 AH, SOC: 34%, I:106A, L:3479, l:3570, H:3518, B:039, PT:029C, BT:028C, PV: 98142, M:Bike On 04635 12/06/2025 07:31:08 SOC:41157,62233,52130,114800,55,34,34,142 04636 12/06/2025 07:31:08 Discharge cutback 69% 04637 12/06/2025 07:31:08 597A 04638 12/06/2025 07:32:08 Discharge level 052 AH, SOC: 35%, I: 0A, L:3587, l:3624, H:3604, B:017, PT:029C, BT:027C, PV:100810, M:Bike On 04639 12/06/2025 07:32:08 SOC:41311,62634,52682,114800,55,45,35,58 04640 12/06/2025 07:32:08 Discharge cutback 74% 04641 12/06/2025 07:32:08 634A 04642 12/06/2025 07:33:08 Discharge level 053 AH, SOC: 35%, I: 1A, L:3590, l:3628, H:3605, B:015, PT:029C, BT:028C, PV:100861, M:Bike On 04643 12/06/2025 07:33:08 SOC:41314,63065,53118,114800,54,46,35,60 04644 12/06/2025 07:33:08 Discharge cutback 72% 04645 12/06/2025 07:33:08 621A 04646 12/06/2025 07:34:08 Discharge level 054 AH, SOC: 34%, I:-28A, L:3611, l:3636, H:3623, B:012, PT:029C, BT:027C, PV:101353, M:Bike On 04647 12/06/2025 07:34:08 SOC:41818,62862,54057,114800,53,47,34,39 04648 12/06/2025 07:34:08 Discharge cutback 69% 04649 12/06/2025 07:34:08 597A 04650 12/06/2025 07:35:08 Discharge level 054 AH, SOC: 34%, I:876A, L:3589, l:14641, H:3605, B:016, PT:029C, BT:028C, PV:1765032171, M:None 04651 12/06/2025 07:40:08 Discharge cutback 77% 04652 12/06/2025 07:40:08 Discharge cutback 77% 04653 12/06/2025 07:40:08 Discharge cutback 77% 04654 12/06/2025 07:40:08 Discharge cutback 77% 04655 12/06/2025 07:40:08 Discharge cutback 77% 04656 12/06/2025 07:40:08 661A 04657 12/06/2025 07:41:08 Discharge level 056 AH, SOC: 36%, I: -4A, L:3600, l:3614, H:3614, B:014, PT:029C, BT:029C, PV:101110, M:Bike On 04658 12/06/2025 07:41:08 SOC:41907,64863,56817,114800,51,44,36,23 04659 12/06/2025 07:41:08 Discharge cutback 76% 04660 12/06/2025 07:41:08 655A 04661 12/06/2025 07:42:08 Discharge level 056 AH, SOC: 37%, I: 1A, L:3601, l:3612, H:3615, B:014, PT:029C, BT:029C, PV:101146, M:Bike On 04662 12/06/2025 07:42:08 SOC:41815,65533,56927,114800,51,43,37,18 04663 12/06/2025 07:42:08 Discharge cutback 78% 04664 12/06/2025 07:42:08 675A 04665 12/06/2025 07:43:08 Discharge level 056 AH, SOC: 38%, I: 1A, L:3606, l:3614, H:3620, B:014, PT:029C, BT:029C, PV:101285, M:Bike On 04666 12/06/2025 07:43:08 SOC:41604,66104,56936,114800,51,43,38,12 04667 12/06/2025 07:43:08 Discharge cutback 81% 04668 12/06/2025 07:43:08 695A 04669 12/06/2025 07:44:08 Discharge level 056 AH, SOC: 38%, I: 0A, L:3610, l:3616, H:3623, B:013, PT:029C, BT:029C, PV:101369, M:Bike On 04670 12/06/2025 07:44:08 SOC:41467,66841,56947,114800,51,44,38,9 04671 12/06/2025 07:44:08 Discharge cutback 82% 04672 12/06/2025 07:44:08 702A 04673 12/06/2025 07:45:08 Discharge level 057 AH, SOC: 39%, I: 1A, L:3605, l:3615, H:3620, B:015, PT:029C, BT:029C, PV:101259, M:Bike On 04674 12/06/2025 07:45:08 SOC:41528,67378,57134,114800,51,44,39,16 04675 12/06/2025 07:45:08 Discharge cutback 79% 04676 12/06/2025 07:45:08 682A 04677 12/06/2025 07:46:08 Discharge level 057 AH, SOC: 39%, I: 1A, L:3600, l:3613, H:3615, B:015, PT:029C, BT:029C, PV:101130, M:Bike On 04678 12/06/2025 07:46:08 SOC:41689,67715,57408,114800,50,43,39,20 04679 12/06/2025 07:46:08 Discharge cutback 78% 04680 12/06/2025 07:46:08 668A 04681 12/06/2025 07:47:08 Discharge level 058 AH, SOC: 36%, I:135A, L:3425, l:3540, H:3473, B:048, PT:029C, BT:029C, PV: 96814, M:Bike On 04682 12/06/2025 07:47:08 SOC:43014,66773,58804,114800,49,25,36,180 04683 12/06/2025 07:47:08 Discharge cutback 48% 04684 12/06/2025 07:47:08 415A 04685 12/06/2025 07:48:00 Discharged To Low 061 AH, SOC: 47%, L:3246, H:3331, B:085, PT:030C, BT:029C, PV: 92436 04686 12/06/2025 07:48:08 Discharge level 061 AH, SOC: 30%, I: 1A, L:3499, l:3582, H:3527, B:028, PT:030C, BT:029C, PV: 98552, M:Bike On 04687 12/06/2025 07:48:08 SOC:45500,64107,61414,114800,47,36,30,133 04688 12/06/2025 07:48:08 Discharge cutback 42% 04689 12/06/2025 07:48:08 361A 04690 12/06/2025 07:49:08 Discharge level 063 AH, SOC: 26%, I:115A, L:3395, l:3517, H:3447, B:052, PT:030C, BT:029C, PV: 96054, M:Bike On 04691 12/06/2025 07:49:08 SOC:47069,63243,63008,114800,46,17,26,190 04692 12/06/2025 07:49:08 Discharge cutback 55% 04693 12/06/2025 07:49:08 469A 04694 12/06/2025 07:50:08 Discharge level 065 AH, SOC: 19%, I: 0A, L:3446, l:3562, H:3483, B:037, PT:031C, BT:029C, PV: 97249, M:Bike On 04695 12/06/2025 07:50:08 SOC:50004,61370,65965,114800,43,31,19,177 04696 12/06/2025 07:50:08 Discharge cutback 35% 04697 12/06/2025 07:50:08 303A 04698 12/06/2025 07:51:08 Discharge level 067 AH, SOC: 18%, I: 1A, L:3494, l:3567, H:3521, B:027, PT:032C, BT:029C, PV: 98393, M:Bike On 04699 12/06/2025 07:51:08 SOC:50883,61486,67126,114800,42,31,18,109 04700 12/06/2025 07:51:08 Discharge cutback 48% 04701 12/06/2025 07:51:08 415A 04702 12/06/2025 07:52:08 Discharge level 067 AH, SOC: 19%, I: 1A, L:3528, l:3566, H:3550, B:022, PT:032C, BT:028C, PV: 99261, M:Bike On 04703 12/06/2025 07:52:08 SOC:50826,62694,67394,114800,42,33,19,62 04704 12/06/2025 07:52:08 Discharge cutback 62% 04705 12/06/2025 07:52:08 536A 04706 12/06/2025 07:53:08 Discharge level 068 AH, SOC: 19%, I: 79A, L:3420, l:3511, H:3465, B:045, PT:032C, BT:029C, PV: 96680, M:Bike On 04707 12/06/2025 07:53:08 SOC:51721,63275,68436,114800,41,16,19,146 04708 12/06/2025 07:53:08 Discharge cutback 55% 04709 12/06/2025 07:53:08 476A 04710 12/06/2025 07:54:08 Discharge level 069 AH, SOC: 19%, I: 85A, L:3441, l:3519, H:3481, B:040, PT:032C, BT:029C, PV: 97168, M:Bike On 04711 12/06/2025 07:54:08 SOC:51976,63682,69065,114800,40,18,19,126 04712 12/06/2025 07:54:08 Discharge cutback 59% 04713 12/06/2025 07:54:08 509A 04714 12/06/2025 07:55:08 Discharge level 069 AH, SOC: 20%, I: 1A, L:3534, l:3561, H:3553, B:019, PT:032C, BT:030C, PV: 99381, M:Bike On 04715 12/06/2025 07:55:08 SOC:51898,64626,69331,114800,40,32,20,45 04716 12/06/2025 07:55:08 Discharge cutback 65% 04717 12/06/2025 07:55:08 557A 04718 12/06/2025 07:56:08 Discharge level 069 AH, SOC: 23%, I: 1A, L:3547, l:3564, H:3565, B:018, PT:032C, BT:030C, PV: 99710, M:Bike On 04719 12/06/2025 07:56:08 SOC:51915,66630,69350,114800,40,33,23,29 04720 12/06/2025 07:56:08 Discharge cutback 68% 04721 12/06/2025 07:56:08 587A 04722 12/06/2025 07:57:08 Discharge level 069 AH, SOC: 25%, I: 1A, L:3553, l:3565, H:3571, B:018, PT:032C, BT:028C, PV: 99867, M:Bike On 04723 12/06/2025 07:57:08 SOC:51936,68427,69373,114800,40,33,25,21 04724 12/06/2025 07:57:08 Discharge cutback 70% 04725 12/06/2025 07:57:08 601A 04726 12/06/2025 07:57:30 DEBUG: Entered Charging State 04727 12/06/2025 07:57:30 DEBUG: CAN NOT Receiving Syncs 04728 12/06/2025 07:57:31 Discharge level 069 AH, SOC: 25%, I: 1A, L:3555, l:3566, H:3572, B:017, PT:032C, BT:029C, PV: 99917, M:Charge 04729 12/06/2025 07:57:31 SOC:51917,68959,69379,114800,40,33,25,19 04730 12/06/2025 07:57:31 DEBUG: CAN Link Is Down 04731 12/06/2025 07:57:32 Contactor was Opened Pack V: 99918mV, Switched V: 99918mV, Prechg Pct: 100%, Dischg Cur: 818mA 04732 12/06/2025 07:57:32 DEBUG: CAN Link Is Up 04733 12/06/2025 07:57:32 DEBUG: CAN Receiving Syncs 04734 12/06/2025 07:57:34 DEBUG: Entered Running State 04735 12/06/2025 07:57:34 DEBUG: CAN NOT Receiving Syncs 04736 12/06/2025 07:57:34 System Turned Off 04737 12/06/2025 07:57:35 Discharge level 069 AH, SOC: 25%, I: 0A, L:3555, l:3566, H:3573, B:018, PT:032C, BT:029C, PV: 99922, M:Bike On 04738 12/06/2025 07:57:35 SOC:51908,68959,69379,114800,40,33,25,19 04739 12/06/2025 07:57:35 Discharge cutback 70% 04740 12/06/2025 07:57:35 604A 04741 12/06/2025 07:57:35 DEBUG: CAN Link Is Down 04742 12/06/2025 07:57:35 DEBUG: CAN Receiving Syncs 04743 12/06/2025 07:57:35 DEBUG: Entered Idle State 04744 12/06/2025 07:57:42 Discharge level 069 AH, SOC: 25%, I: 0A, L:3556, l:3567, H:3573, B:017, PT:032C, BT:030C, PV: 99948, M:Idle 04745 12/06/2025 07:57:42 SOC:51903,68959,69379,114800,40,33,25,18 04746 12/06/2025 07:57:43 System Turned On 04747 12/06/2025 07:57:43 Rev:45,Build:2023-05-20_045619 958 banka 04748 12/06/2025 07:57:43 Pack:2019_monolith,Numbricks:4 04749 12/06/2025 07:57:43 DEBUG: Entered Running State 04750 12/06/2025 07:57:43 DEBUG: CAN NOT Receiving Syncs 04751 12/06/2025 07:57:43 DEBUG: CAN Link Is Up 04752 12/06/2025 07:57:44 DEBUG: Resetting CAN0 due to error passive mode 04753 12/06/2025 07:57:44 Discharge level 069 AH, SOC: 25%, I: 0A, L:3555, l:3566, H:3573, B:018, PT:032C, BT:029C, PV: 99941, M:Bike On 04754 12/06/2025 07:57:44 SOC:51897,68959,69379,114800,40,33,25,18 04755 12/06/2025 07:57:44 Discharge cutback 71% 04756 12/06/2025 07:57:44 607A 04757 12/06/2025 07:57:47 DEBUG: CAN Receiving Syncs 04758 12/06/2025 07:57:47 Contactor drive turned on Pack V: 99942mV, Switched V: 88064mV, Duty Cycle: 40% 04759 12/06/2025 07:57:47 Contactor was Closed Pack V: 99942mV, Switched V: 88064mV, Prechg Pct: 88%, Dischg Cur: 636mA 04760 12/06/2025 07:57:49 DEBUG: Entered Charging State 04761 12/06/2025 07:57:49 DEBUG: CAN NOT Receiving Syncs 04762 12/06/2025 07:57:50 Discharge level 069 AH, SOC: 25%, I: 1A, L:3556, l:3567, H:3574, B:018, PT:032C, BT:029C, PV: 99945, M:Charge 04763 12/06/2025 07:57:51 SOC:51865,69010,69380,114800,40,33,25,18 04764 12/06/2025 07:57:51 DEBUG: CAN Receiving Syncs 04765 12/06/2025 08:07:50 Discharge level 063 AH, SOC: 41%, I:-32A, L:3656, l:3623, H:3666, B:010, PT:032C, BT:030C, PV:102561, M:Charge 04766 12/06/2025 08:07:51 SOC:33628,56334,63885,114800,45,46,41,-59 04767 12/06/2025 08:17:51 Discharge level 058 AH, SOC: 52%, I:-32A, L:3684, l:3649, H:3691, B:007, PT:032C, BT:031C, PV:103277, M:Charge 04768 12/06/2025 08:17:51 SOC:26374,54604,58372,114800,50,50,52,-61 04769 12/06/2025 08:27:51 Discharge level 052 AH, SOC: 58%, I:-33A, L:3706, l:3671, H:3714, B:008, PT:032C, BT:038C, PV:103903, M:Charge 04770 12/06/2025 08:27:51 SOC:25096,58780,52927,114800,54,53,58,-62 04771 12/06/2025 08:37:58 Discharge level 047 AH, SOC: 61%, I:-32A, L:3735, l:3700, H:3745, B:010, PT:033C, BT:042C, PV:104739, M:Charge 04772 12/06/2025 08:37:58 SOC:25237,64387,47473,114800,59,57,61,-61 04773 12/06/2025 08:47:58 Discharge level 042 AH, SOC: 65%, I:-30A, L:3771, l:3736, H:3783, B:012, PT:033C, BT:043C, PV:105742, M:Charge 04774 12/06/2025 08:47:58 SOC:24736,69202,42167,114800,64,62,65,-59 04775 12/06/2025 08:57:58 Discharge level 036 AH, SOC: 69%, I:-31A, L:3814, l:3779, H:3827, B:013, PT:034C, BT:044C, PV:106938, M:Charge 04776 12/06/2025 08:57:58 SOC:22880,72549,36976,114800,68,67,69,-59 04777 12/06/2025 09:07:58 Discharge level 031 AH, SOC: 74%, I:-30A, L:3864, l:3829, H:3879, B:015, PT:034C, BT:045C, PV:108337, M:Charge 04778 12/06/2025 09:07:58 SOC:20144,74870,31934,114800,73,72,74,-57 04779 12/06/2025 09:17:58 Discharge level 026 AH, SOC: 79%, I:-29A, L:3918, l:3884, H:3929, B:011, PT:035C, BT:048C, PV:109832, M:Charge 04780 12/06/2025 09:17:58 SOC:16618,76332,26961,114800,77,78,79,-56 04781 12/06/2025 09:27:58 Discharge level 022 AH, SOC: 84%, I:-29A, L:3969, l:3937, H:3978, B:009, PT:035C, BT:050C, PV:111252, M:Charge 04782 12/06/2025 09:27:58 SOC:13049,77708,22033,114800,81,82,84,-56 04783 12/06/2025 09:37:58 Discharge level 017 AH, SOC: 88%, I:-29A, L:4019, l:3988, H:4027, B:008, PT:035C, BT:051C, PV:112609, M:Charge 04784 12/06/2025 09:37:58 SOC:9659,79170,17198,114800,86,87,88,-55 04785 12/06/2025 09:41:15 Charged To Full 015 AH, SOC: 90%, L:4034, H:4043, B:009, PT:035C, BT:051C, PV:112751 04786 12/06/2025 09:41:15 SOC adjusted for voltage old: 8571443uAH (soc:90%), new: 7169195uAH (soc:91%), low cell: 4034 mV 04787 12/06/2025 09:48:06 Discharge level 007 AH, SOC: 93%, I:-27A, L:4068, l:4040, H:4078, B:010, PT:035C, BT:050C, PV:114018, M:Charge 04788 12/06/2025 09:48:06 SOC:5954,81703,7082,114800,94,92,93,-53 04789 12/06/2025 09:58:06 Discharge level 002 AH, SOC: 98%, I:-28A, L:4117, l:4089, H:4129, B:012, PT:035C, BT:051C, PV:115410, M:Charge 04790 12/06/2025 09:58:06 SOC:2440,82889,2400,114800,98,97,98,-53 04791 12/06/2025 10:08:06 Discharge level 000 AH, SOC:100%, I:-18A, L:4151, l:4131, H:4160, B:009, PT:035C, BT:052C, PV:116319, M:Charge 04792 12/06/2025 10:08:06 SOC:0,83413,0,114800,100,100,100,-36 04793 12/06/2025 10:18:06 Discharge level 000 AH, SOC:100%, I: -5A, L:4155, l:4148, H:4160, B:005, PT:035C, BT:048C, PV:116370, M:Charge 04794 12/06/2025 10:18:06 SOC:0,83413,0,114800,100,100,100,-14 04795 12/06/2025 10:23:49 DEBUG: CAN Link Is Down 04796 12/06/2025 10:23:53 Contactor was Opened Pack V: 116146mV, Switched V: 116145mV, Prechg Pct: 100%, Dischg Cur: 818mA 04797 12/06/2025 10:23:53 DEBUG: CAN Link Is Up 04798 12/06/2025 10:23:55 System Turned Off 04799 12/06/2025 10:23:56 DEBUG: CAN Link Is Down 04800 12/06/2025 10:23:56 DEBUG: Entered Idle State 04801 12/06/2025 10:24:02 Current Sensor Zeroed old: 2504mV, new: 2508mV, corrfact: 248 04802 12/06/2025 10:24:02 Current Sensor Zeroed old: 2504mV, new: 2506mV, corrfact: 250 04803 12/06/2025 10:24:04 Discharge level 000 AH, SOC:100%, I: 0A, L:4151, l:4149, H:4154, B:003, PT:034C, BT:042C, PV:116125, M:Idle 04804 12/06/2025 10:24:04 SOC:0,83413,0,114800,100,100,100,-4 04805 12/06/2025 10:24:23 Voltage Across Contactor: 103300mV (Okay) 04806 12/06/2025 11:57:09 System Turned On 04807 12/06/2025 11:57:09 Rev:45,Build:2023-05-20_045619 958 banka 04808 12/06/2025 11:57:09 Pack:2019_monolith,Numbricks:4 04809 12/06/2025 11:57:09 DEBUG: Entered Charging State 04810 12/06/2025 11:57:10 DEBUG: CAN NOT Receiving Syncs 04811 12/06/2025 11:57:10 DEBUG: Entered Running State 04812 12/06/2025 11:57:10 DEBUG: CAN Link Is Up 04813 12/06/2025 11:57:10 DEBUG: Resetting CAN0 due to error passive mode 04814 12/06/2025 11:57:11 Discharge level 000 AH, SOC:100%, I: 0A, L:4131, l:4129, H:4134, B:003, PT:031C, BT:044C, PV:115733, M:Bike On 04815 12/06/2025 11:57:11 SOC:0,83413,0,114800,100,100,100,-3 04816 12/06/2025 11:57:14 DEBUG: CAN Receiving Syncs 04817 12/06/2025 11:57:14 Contactor drive turned on Pack V: 115721mV, Switched V: 101415mV, Duty Cycle: 34% 04818 12/06/2025 11:57:14 Contactor was Closed Pack V: 115721mV, Switched V: 101415mV, Prechg Pct: 88%, Dischg Cur: 454mA 04819 12/06/2025 11:58:11 Discharge level 000 AH, SOC:100%, I: 0A, L:4130, l:4130, H:4134, B:004, PT:031C, BT:042C, PV:115718, M:Bike On 04820 12/06/2025 11:58:11 SOC:0,83413,0,114800,100,100,100,0 04821 12/06/2025 11:59:11 Discharge level 000 AH, SOC:100%, I: 0A, L:4129, l:4129, H:4133, B:004, PT:031C, BT:040C, PV:115713, M:Bike On 04822 12/06/2025 11:59:11 SOC:0,83413,0,114800,100,100,100,0 04823 12/06/2025 12:00:11 Discharge level 000 AH, SOC:100%, I: 0A, L:4128, l:4129, H:4131, B:003, PT:031C, BT:039C, PV:115645, M:Bike On 04824 12/06/2025 12:00:11 SOC:48,83378,51,114800,100,100,100,2 04825 12/06/2025 12:01:11 Discharge level 000 AH, SOC:100%, I: 1A, L:4112, l:4125, H:4118, B:006, PT:030C, BT:037C, PV:115272, M:Bike On 04826 12/06/2025 12:01:11 SOC:359,83057,375,114800,100,100,100,20 04827 12/06/2025 12:02:11 Discharge level 000 AH, SOC:100%, I:-11A, L:4127, l:4129, H:4130, B:003, PT:030C, BT:037C, PV:115609, M:Bike On 04828 12/06/2025 12:02:11 SOC:577,82777,616,114800,100,100,100,3 04829 12/06/2025 12:03:11 Discharge level 000 AH, SOC:100%, I:-16A, L:4131, l:4129, H:4133, B:002, PT:030C, BT:036C, PV:115699, M:Bike On 04830 12/06/2025 12:03:11 SOC:602,82609,679,114800,100,100,100,-3 04831 12/06/2025 12:04:11 Discharge level 000 AH, SOC:100%, I: 0A, L:4117, l:4119, H:4122, B:005, PT:030C, BT:035C, PV:115378, M:Bike On 04832 12/06/2025 12:04:11 SOC:586,82526,686,114800,100,99,100,3 04833 12/06/2025 12:05:11 Discharge level 000 AH, SOC:100%, I: 48A, L:4044, l:4075, H:4065, B:021, PT:030C, BT:035C, PV:113642, M:Bike On 04834 12/06/2025 12:05:11 SOC:811,82268,925,114800,100,95,100,50 04835 12/06/2025 12:06:11 Discharge level 001 AH, SOC: 99%, I:182A, L:3877, l:3991, H:3932, B:055, PT:030C, BT:034C, PV:109537, M:Bike On 04836 12/06/2025 12:06:11 SOC:1447,81631,1579,114800,99,87,99,183 04837 12/06/2025 12:07:11 Discharge level 002 AH, SOC: 97%, I: 87A, L:3948, l:4023, H:3986, B:038, PT:030C, BT:034C, PV:111254, M:Bike On 04838 12/06/2025 12:07:11 SOC:2591,80532,2723,114800,98,90,97,121 04839 12/06/2025 12:08:11 Discharge level 004 AH, SOC: 95%, I: 88A, L:3917, l:4008, H:3957, B:040, PT:030C, BT:033C, PV:110422, M:Bike On 04840 12/06/2025 12:08:11 SOC:4117,79093,4250,114800,97,88,95,147 04841 12/06/2025 12:09:11 Discharge level 005 AH, SOC: 93%, I:102A, L:3867, l:3979, H:3916, B:049, PT:031C, BT:033C, PV:109209, M:Bike On 04842 12/06/2025 12:09:11 SOC:5791,77608,5926,114800,95,86,93,179 04843 12/06/2025 12:10:11 Discharge level 007 AH, SOC: 91%, I:128A, L:3817, l:3942, H:3875, B:058, PT:031C, BT:032C, PV:107986, M:Bike On 04844 12/06/2025 12:10:11 SOC:7381,76259,7515,114800,94,82,91,205 04845 12/06/2025 12:11:11 Discharge level 009 AH, SOC: 87%, I:123A, L:3782, l:3925, H:3841, B:059, PT:031C, BT:031C, PV:107019, M:Bike On 04846 12/06/2025 12:11:11 SOC:9724,74633,9859,114800,92,81,87,227 04847 12/06/2025 12:12:11 Discharge level 011 AH, SOC: 84%, I:157A, L:3730, l:3894, H:3798, B:068, PT:032C, BT:032C, PV:105768, M:Bike On 04848 12/06/2025 12:12:11 SOC:11811,73503,11947,114800,90,78,84,253 04849 12/06/2025 12:13:11 Discharge level 014 AH, SOC: 81%, I:357A, L:3499, l:3774, H:3616, B:117, PT:032C, BT:031C, PV:100224, M:Bike On 04850 12/06/2025 12:13:11 SOC:14228,72435,14367,114800,88,64,81,418 04851 12/06/2025 12:14:11 Discharge level 016 AH, SOC: 77%, I:169A, L:3661, l:3842, H:3738, B:077, PT:033C, BT:031C, PV:104047, M:Bike On 04852 12/06/2025 12:14:11 SOC:16520,71740,16661,114800,86,73,77,281 04853 12/06/2025 12:15:11 Discharge level 018 AH, SOC: 74%, I:132A, L:3674, l:3840, H:3744, B:070, PT:033C, BT:031C, PV:104289, M:Bike On 04854 12/06/2025 12:15:11 SOC:18837,71244,18979,114800,84,72,74,257 04855 12/06/2025 12:16:11 Discharge level 021 AH, SOC: 71%, I:132A, L:3659, l:3812, H:3730, B:071, PT:034C, BT:030C, PV:103907, M:Bike On 04856 12/06/2025 12:16:11 SOC:20887,71093,21039,114800,82,70,71,248 04857 12/06/2025 12:17:11 Discharge level 023 AH, SOC: 68%, I:104A, L:3672, l:3803, H:3734, B:062, PT:034C, BT:030C, PV:104100, M:Bike On 04858 12/06/2025 12:17:11 SOC:22862,71137,23016,114800,80,69,68,215 04859 12/06/2025 12:18:11 Discharge level 024 AH, SOC: 66%, I: 78A, L:3684, l:3797, H:3739, B:055, PT:034C, BT:030C, PV:104297, M:Bike On 04860 12/06/2025 12:18:11 SOC:24808,71250,24971,114800,79,68,66,189 04861 12/06/2025 12:19:11 Discharge level 026 AH, SOC: 63%, I:148A, L:3604, l:3742, H:3677, B:073, PT:035C, BT:030C, PV:102430, M:Bike On 04862 12/06/2025 12:19:11 SOC:26749,71450,26920,114800,77,62,63,235 04863 12/06/2025 12:20:11 Discharge level 029 AH, SOC: 60%, I:470A, L:3332, l:3594, H:3478, B:146, PT:035C, BT:029C, PV: 96269, M:Bike On 04864 12/06/2025 12:20:11 SOC:28855,71524,29033,114800,75,38,60,463 04865 12/06/2025 12:20:11 Discharge cutback 89% 04866 12/06/2025 12:20:11 769A 04867 12/06/2025 12:21:11 Discharge level 031 AH, SOC: 57%, I: 1A, L:3663, l:3759, H:3706, B:043, PT:036C, BT:030C, PV:103497, M:Bike On 04868 12/06/2025 12:21:11 SOC:31309,71198,31533,114800,73,64,57,173 04869 12/06/2025 12:21:11 Discharge cutback 84% 04870 12/06/2025 12:21:11 725A 04871 12/06/2025 12:22:11 Discharge level 033 AH, SOC: 55%, I: 1A, L:3683, l:3748, H:3717, B:034, PT:036C, BT:030C, PV:103864, M:Bike On 04872 12/06/2025 12:22:11 SOC:32761,71391,33078,114800,72,63,55,121 04873 12/06/2025 12:22:11 Discharge cutback 86% 04874 12/06/2025 12:22:11 742A 04875 12/06/2025 12:23:11 Discharge level 033 AH, SOC: 54%, I:177A, L:3567, l:3674, H:3634, B:067, PT:037C, BT:029C, PV:101286, M:Bike On 04876 12/06/2025 12:23:11 SOC:33213,72147,33764,114800,71,53,54,199 04877 12/06/2025 12:24:11 Discharge level 036 AH, SOC: 51%, I:104A, L:3564, l:3675, H:3624, B:060, PT:037C, BT:030C, PV:101067, M:Bike On 04878 12/06/2025 12:24:11 SOC:35567,71955,36169,114800,69,53,51,210 04879 12/06/2025 12:24:11 Discharge cutback 80% 04880 12/06/2025 12:24:11 688A 04881 12/06/2025 12:25:11 Discharge level 039 AH, SOC: 46%, I: 61A, L:3568, l:3665, H:3621, B:053, PT:038C, BT:029C, PV:101044, M:Bike On 04882 12/06/2025 12:25:11 SOC:38593,71089,39214,114800,66,52,46,189 04883 12/06/2025 12:25:11 Discharge cutback 72% 04884 12/06/2025 12:25:11 617A 04885 12/06/2025 12:26:11 Discharge level 039 AH, SOC: 47%, I: 1A, L:3660, l:3697, H:3688, B:028, PT:038C, BT:030C, PV:103105, M:Bike On 04886 12/06/2025 12:26:11 SOC:38516,71866,39552,114800,66,57,47,72 04887 12/06/2025 12:26:11 Discharge cutback 88% 04888 12/06/2025 12:26:11 756A 04889 12/06/2025 12:26:59 Contactor was Opened Pack V: 103455mV, Switched V: 103384mV, Prechg Pct: 100%, Dischg Cur: 1182mA 04890 12/06/2025 12:27:00 System Turned Off 04891 12/06/2025 12:27:01 DEBUG: CAN Link Is Down 04892 12/06/2025 12:27:01 DEBUG: Entered Idle State 04893 12/06/2025 12:27:06 Current Sensor Zeroed old: 2508mV, new: 2507mV, corrfact: 249 04894 12/06/2025 12:27:07 Current Sensor Zeroed old: 2506mV, new: 2504mV, corrfact: 252 04895 12/06/2025 12:27:08 Discharge level 039 AH, SOC: 48%, I: 0A, L:3680, l:3703, H:3702, B:022, PT:038C, BT:030C, PV:103535, M:Idle 04896 12/06/2025 12:27:08 SOC:38338,72798,39661,114800,66,58,48,46 04897 12/06/2025 12:27:29 Voltage Across Contactor: 90560mV (Okay) 04898 12/06/2025 12:28:33 System Turned On 04899 12/06/2025 12:28:33 Rev:45,Build:2023-05-20_045619 958 banka 04900 12/06/2025 12:28:33 Pack:2019_monolith,Numbricks:4 04901 12/06/2025 12:28:33 DEBUG: Entered Running State 04902 12/06/2025 12:28:33 DEBUG: CAN NOT Receiving Syncs 04903 12/06/2025 12:28:33 DEBUG: CAN Link Is Up 04904 12/06/2025 12:28:34 DEBUG: Resetting CAN0 due to error passive mode 04905 12/06/2025 12:28:34 Discharge level 039 AH, SOC: 48%, I: 0A, L:3694, l:3717, H:3711, B:017, PT:038C, BT:029C, PV:103816, M:Bike On 04906 12/06/2025 12:28:34 SOC:38328,72798,39661,114800,66,60,48,46 04907 12/06/2025 12:28:37 DEBUG: CAN Receiving Syncs 04908 12/06/2025 12:28:37 Contactor drive turned on Pack V: 103817mV, Switched V: 91017mV, Duty Cycle: 38% 04909 12/06/2025 12:28:37 Contactor was Closed Pack V: 103817mV, Switched V: 91017mV, Prechg Pct: 88%, Dischg Cur: 545mA 04910 12/06/2025 12:28:53 DEBUG: Entered Charging State 04911 12/06/2025 12:28:53 DEBUG: CAN NOT Receiving Syncs 04912 12/06/2025 12:28:54 Discharge level 039 AH, SOC: 48%, I: 0A, L:3696, l:3716, H:3713, B:017, PT:038C, BT:030C, PV:103846, M:Charge 04913 12/06/2025 12:28:54 SOC:38069,72810,39661,114800,66,59,48,39 04914 12/06/2025 12:28:54 DEBUG: CAN Receiving Syncs 04915 12/06/2025 12:38:54 Discharge level 037 AH, SOC: 60%, I:-11A, L:3749, l:3739, H:3757, B:008, PT:037C, BT:037C, PV:105129, M:Charge 04916 12/06/2025 12:38:54 SOC:25374,62159,37723,114800,68,62,60,-19 04917 12/06/2025 12:48:54 Discharge level 035 AH, SOC: 65%, I:-11A, L:3775, l:3763, H:3780, B:005, PT:037C, BT:040C, PV:105769, M:Charge 04918 12/06/2025 12:48:54 SOC:21089,59837,35777,114800,69,65,65,-21 04919 12/06/2025 12:58:54 Discharge level 033 AH, SOC: 68%, I:-11A, L:3797, l:3784, H:3803, B:006, PT:036C, BT:042C, PV:106400, M:Charge 04920 12/06/2025 12:58:54 SOC:19354,60046,33849,114800,71,67,68,-22 04921 12/06/2025 13:09:02 Discharge level 031 AH, SOC: 71%, I:-11A, L:3820, l:3807, H:3827, B:007, PT:036C, BT:042C, PV:107044, M:Charge 04922 12/06/2025 13:09:02 SOC:17900,60552,31907,114800,73,70,71,-21 04923 12/06/2025 13:19:02 Discharge level 030 AH, SOC: 73%, I:-11A, L:3844, l:3832, H:3851, B:007, PT:036C, BT:043C, PV:107715, M:Charge 04924 12/06/2025 13:19:02 SOC:16722,61291,30009,114800,74,72,73,-21 04925 12/06/2025 13:29:02 Discharge level 028 AH, SOC: 76%, I:-11A, L:3869, l:3856, H:3875, B:006, PT:035C, BT:044C, PV:108393, M:Charge 04926 12/06/2025 13:29:02 SOC:15337,61792,28142,114800,76,75,76,-21 04927 12/06/2025 13:39:02 Discharge level 026 AH, SOC: 78%, I:-11A, L:3893, l:3880, H:3897, B:004, PT:035C, BT:044C, PV:109057, M:Charge 04928 12/06/2025 13:39:02 SOC:13996,62319,26293,114800,78,77,78,-21 04929 12/06/2025 13:49:02 Discharge level 024 AH, SOC: 80%, I:-10A, L:3914, l:3901, H:3919, B:005, PT:034C, BT:045C, PV:109677, M:Charge 04930 12/06/2025 13:49:02 SOC:12814,62985,24463,114800,79,79,80,-20 04931 12/06/2025 13:59:02 Discharge level 022 AH, SOC: 82%, I:-11A, L:3935, l:3922, H:3939, B:004, PT:034C, BT:048C, PV:110259, M:Charge 04932 12/06/2025 13:59:02 SOC:11752,63761,22644,114800,81,81,82,-20 04933 12/06/2025 14:09:02 Discharge level 020 AH, SOC: 84%, I:-10A, L:3954, l:3941, H:3959, B:005, PT:033C, BT:047C, PV:110805, M:Charge 04934 12/06/2025 14:09:02 SOC:10713,64543,20842,114800,82,83,84,-20 04935 12/06/2025 14:19:02 Discharge level 019 AH, SOC: 86%, I:-11A, L:3974, l:3961, H:3978, B:004, PT:033C, BT:047C, PV:111351, M:Charge 04936 12/06/2025 14:19:02 SOC:9600,65244,19047,114800,84,85,86,-20 04937 12/06/2025 14:29:09 Discharge level 017 AH, SOC: 87%, I:-10A, L:3994, l:3981, H:3997, B:003, PT:032C, BT:043C, PV:111890, M:Charge 04938 12/06/2025 14:29:10 SOC:8696,66176,17232,114800,85,86,87,-20 04939 12/06/2025 14:39:09 Discharge level 015 AH, SOC: 89%, I:-10A, L:4014, l:4002, H:4016, B:002, PT:032C, BT:039C, PV:112423, M:Charge 04940 12/06/2025 14:39:10 SOC:7570,66843,15459,114800,87,88,89,-20 04941 12/06/2025 14:44:43 Charged To Full 014 AH, SOC: 90%, L:4025, H:4027, B:002, PT:031C, BT:036C, PV:112732 04942 12/06/2025 14:44:43 SOC adjusted for voltage old: 6952250uAH (soc:90%), new: 6722411uAH (soc:90%), low cell: 4025 mV 04943 12/06/2025 14:49:09 Discharge level 010 AH, SOC: 91%, I:-10A, L:4033, l:4021, H:4036, B:003, PT:031C, BT:033C, PV:112975, M:Charge 04944 12/06/2025 14:49:10 SOC:6322,67612,10701,114800,91,90,91,-20 04945 12/06/2025 14:59:10 Discharge level 008 AH, SOC: 93%, I:-10A, L:4054, l:4042, H:4055, B:001, PT:031C, BT:032C, PV:113518, M:Charge 04946 12/06/2025 14:59:10 SOC:5192,68259,8943,114800,93,92,93,-19 04947 12/06/2025 15:09:10 Discharge level 007 AH, SOC: 95%, I:-10A, L:4073, l:4061, H:4075, B:002, PT:030C, BT:031C, PV:114056, M:Charge 04948 12/06/2025 15:09:10 SOC:3957,68779,7207,114800,94,94,95,-19 04949 12/06/2025 15:19:10 Discharge level 005 AH, SOC: 96%, I:-10A, L:4092, l:4079, H:4096, B:004, PT:030C, BT:032C, PV:114616, M:Charge 04950 12/06/2025 15:19:10 SOC:2781,69349,5481,114800,96,96,96,-19 04951 12/06/2025 16:02:21 DEBUG: CAN Link Is Down 04952 12/06/2025 16:02:25 Contactor was Opened Pack V: 116117mV, Switched V: 116145mV, Prechg Pct: 100%, Dischg Cur: 545mA 04953 12/06/2025 16:02:25 DEBUG: CAN Link Is Up 04954 12/06/2025 16:02:27 System Turned Off 04955 12/06/2025 16:02:28 DEBUG: CAN Link Is Down 04956 12/06/2025 16:02:28 DEBUG: Entered Idle State 04957 12/06/2025 16:02:35 Discharge level 000 AH, SOC:100%, I: 0A, L:4149, l:4147, H:4152, B:003, PT:028C, BT:034C, PV:116069, M:Idle 04958 12/06/2025 16:02:35 SOC:0,70315,0,114800,100,100,100,-4 04959 12/06/2025 16:02:55 Voltage Across Contactor: 103193mV (Okay) 04960 12/06/2025 22:10:35 System Turned On 04961 12/06/2025 22:10:35 Rev:45,Build:2023-05-20_045619 958 banka 04962 12/06/2025 22:10:35 Pack:2019_monolith,Numbricks:4 04963 12/06/2025 22:10:35 DEBUG: Entered Charging State 04964 12/06/2025 22:10:35 DEBUG: CAN NOT Receiving Syncs 04965 12/06/2025 22:10:35 DEBUG: Entered Running State 04966 12/06/2025 22:10:35 DEBUG: CAN Link Is Up 04967 12/06/2025 22:10:36 DEBUG: Resetting CAN0 due to error passive mode 04968 12/06/2025 22:10:36 Discharge level 000 AH, SOC:100%, I: 0A, L:4126, l:4122, H:4128, B:002, PT:016C, BT:021C, PV:115543, M:Bike On 04969 12/06/2025 22:10:36 SOC:0,70315,0,114800,100,100,100,-3 04970 12/06/2025 22:10:39 DEBUG: CAN Receiving Syncs 04971 12/06/2025 22:10:44 Contactor drive turned on Pack V: 115497mV, Switched V: 102400mV, Duty Cycle: 34% 04972 12/06/2025 22:10:44 Contactor was Closed Pack V: 115497mV, Switched V: 102400mV, Prechg Pct: 89%, Dischg Cur: 909mA 04973 12/06/2025 22:11:36 Discharge level 000 AH, SOC:100%, I: 1A, L:4123, l:4123, H:4125, B:002, PT:016C, BT:021C, PV:115484, M:Bike On 04974 12/06/2025 22:11:36 SOC:11,70315,12,114800,100,100,100,0 04975 12/06/2025 22:12:36 Discharge level 000 AH, SOC:100%, I: 1A, L:4122, l:4122, H:4125, B:003, PT:016C, BT:021C, PV:115464, M:Bike On 04976 12/06/2025 22:12:36 SOC:25,70315,27,114800,100,100,100,0 04977 12/06/2025 22:13:36 Discharge level 000 AH, SOC:100%, I: 1A, L:4121, l:4122, H:4124, B:003, PT:016C, BT:020C, PV:115451, M:Bike On 04978 12/06/2025 22:13:36 SOC:39,70315,42,114800,100,100,100,1 04979 12/06/2025 22:14:36 Discharge level 000 AH, SOC:100%, I: 1A, L:4121, l:4122, H:4124, B:003, PT:016C, BT:020C, PV:115447, M:Bike On 04980 12/06/2025 22:14:36 SOC:52,70315,57,114800,100,100,100,1 04981 12/06/2025 22:15:36 Discharge level 000 AH, SOC:100%, I: 1A, L:4110, l:4119, H:4114, B:004, PT:016C, BT:021C, PV:115163, M:Bike On 04982 12/06/2025 22:15:36 SOC:225,70081,209,114800,100,99,100,8 04983 12/06/2025 22:16:36 Discharge level 000 AH, SOC:100%, I: 1A, L:4100, l:4114, H:4104, B:004, PT:016C, BT:021C, PV:114878, M:Bike On 04984 12/06/2025 22:16:36 SOC:545,69486,527,114800,100,99,100,13 04985 12/06/2025 22:17:36 Discharge level 000 AH, SOC: 99%, I:109A, L:3860, l:3971, H:3902, B:042, PT:016C, BT:020C, PV:108696, M:Bike On 04986 12/06/2025 22:17:36 SOC:885,68898,857,114800,100,85,99,101 04987 12/06/2025 22:18:36 Discharge level 001 AH, SOC: 98%, I: 58A, L:3910, l:3998, H:3941, B:031, PT:016C, BT:020C, PV:109945, M:Bike On 04988 12/06/2025 22:18:36 SOC:1907,67250,1868,114800,99,88,98,80 04989 12/06/2025 22:19:36 Discharge level 003 AH, SOC: 94%, I:332A, L:3357, l:3755, H:3461, B:104, PT:017C, BT:020C, PV: 95516, M:Bike On 04990 12/06/2025 22:19:36 SOC:4022,64526,3980,114800,97,64,94,365 04991 12/06/2025 22:19:36 Discharge cutback 60% 04992 12/06/2025 22:19:36 519A 04993 12/06/2025 22:20:36 Discharge level 005 AH, SOC: 92%, I:-29A, L:4009, l:4072, H:4020, B:011, PT:018C, BT:020C, PV:112468, M:Bike On 04994 12/06/2025 22:20:36 SOC:5235,63158,5192,114800,96,95,92,58 04995 12/06/2025 22:21:36 Discharge level 006 AH, SOC: 91%, I:109A, L:3728, l:3921, H:3781, B:053, PT:018C, BT:020C, PV:105255, M:Bike On 04996 12/06/2025 22:21:36 SOC:6182,62103,6189,114800,95,80,91,184 04997 12/06/2025 22:22:36 Discharge level 008 AH, SOC: 86%, I:231A, L:3506, l:3827, H:3596, B:090, PT:020C, BT:020C, PV: 99700, M:Bike On 04998 12/06/2025 22:22:36 SOC:8872,60074,8886,114800,93,70,86,315 04999 12/06/2025 22:23:36 Discharge level 011 AH, SOC: 81%, I:120A, L:3630, l:3878, H:3698, B:068, PT:021C, BT:020C, PV:102895, M:Bike On 05000 12/06/2025 22:23:36 SOC:11507,58525,11526,114800,90,75,81,254 05001 12/06/2025 22:24:36 Discharge level 014 AH, SOC: 75%, I:226A, L:3461, l:3775, H:3561, B:100, PT:022C, BT:021C, PV: 98789, M:Bike On 05002 12/06/2025 22:24:36 SOC:14341,57229,14361,114800,88,64,75,341 05003 12/06/2025 22:25:36 Discharge level 017 AH, SOC: 69%, I:328A, L:3329, l:3717, H:3460, B:131, PT:024C, BT:020C, PV: 95761, M:Bike On 05004 12/06/2025 22:25:36 SOC:17733,55783,17869,114800,85,56,69,450 05005 12/06/2025 22:25:36 Discharge cutback 59% 05006 12/06/2025 22:25:36 509A 05007 12/06/2025 22:26:36 Discharge level 020 AH, SOC: 63%, I:216A, L:3444, l:3744, H:3552, B:108, PT:026C, BT:021C, PV: 98590, M:Bike On 05008 12/06/2025 22:26:36 SOC:20831,55572,20973,114800,82,60,63,361 05009 12/06/2025 22:26:36 Discharge cutback 85% 05010 12/06/2025 22:26:36 736A 05011 12/06/2025 22:27:36 Discharge level 024 AH, SOC: 58%, I:156A, L:3510, l:3744, H:3599, B:089, PT:027C, BT:021C, PV:100110, M:Bike On 05012 12/06/2025 22:27:36 SOC:23875,55755,24021,114800,80,61,58,306 05013 12/06/2025 22:27:36 Discharge cutback 84% 05014 12/06/2025 22:27:36 719A 05015 12/06/2025 22:28:36 Discharge level 026 AH, SOC: 53%, I:137A, L:3518, l:3727, H:3603, B:085, PT:029C, BT:022C, PV:100272, M:Bike On 05016 12/06/2025 22:28:36 SOC:26588,56274,26739,114800,77,59,53,291 05017 12/06/2025 22:28:36 Discharge cutback 77% 05018 12/06/2025 22:28:36 665A 05019 12/06/2025 22:29:36 Discharge level 029 AH, SOC: 50%, I:149A, L:3509, l:3704, H:3594, B:085, PT:030C, BT:021C, PV:100053, M:Bike On 05020 12/06/2025 22:29:36 SOC:28917,57221,29070,114800,75,56,50,285 05021 12/06/2025 22:29:36 Discharge cutback 81% 05022 12/06/2025 22:29:36 698A 05023 12/06/2025 22:30:36 Discharge level 031 AH, SOC: 46%, I:147A, L:3484, l:3670, H:3573, B:089, PT:031C, BT:022C, PV: 99420, M:Bike On 05024 12/06/2025 22:30:36 SOC:31511,57948,31666,114800,73,51,46,288 05025 12/06/2025 22:30:36 Discharge cutback 75% 05026 12/06/2025 22:30:36 648A 05027 12/06/2025 22:31:36 Discharge level 034 AH, SOC: 43%, I:153A, L:3476, l:3650, H:3564, B:088, PT:031C, BT:022C, PV: 99198, M:Bike On 05028 12/06/2025 22:31:36 SOC:33868,58835,34026,114800,71,48,43,282 05029 12/06/2025 22:31:36 Discharge cutback 74% 05030 12/06/2025 22:31:36 634A 05031 12/06/2025 22:32:36 Discharge level 036 AH, SOC: 39%, I:151A, L:3451, l:3629, H:3542, B:091, PT:032C, BT:023C, PV: 98560, M:Bike On 05032 12/06/2025 22:32:36 SOC:36369,59570,36529,114800,69,42,39,288 05033 12/06/2025 22:32:36 Discharge cutback 68% 05034 12/06/2025 22:32:36 587A 05035 12/06/2025 22:33:36 Discharge level 039 AH, SOC: 36%, I:128A, L:3455, l:3616, H:3540, B:085, PT:033C, BT:023C, PV: 98555, M:Bike On 05036 12/06/2025 22:33:36 SOC:38937,60145,39099,114800,66,42,36,271 05037 12/06/2025 22:33:36 Discharge cutback 65% 05038 12/06/2025 22:33:36 557A 05039 12/06/2025 22:34:36 Discharge level 041 AH, SOC: 32%, I:208A, L:3372, l:3574, H:3481, B:109, PT:033C, BT:022C, PV: 96747, M:Bike On 05040 12/06/2025 22:34:36 SOC:41487,60829,41649,114800,64,31,32,336 05041 12/06/2025 22:34:36 Discharge cutback 60% 05042 12/06/2025 22:34:36 513A 05043 12/06/2025 22:35:36 Discharge level 044 AH, SOC: 29%, I:218A, L:3348, l:3543, H:3459, B:111, PT:034C, BT:023C, PV: 96110, M:Bike On 05044 12/06/2025 22:35:36 SOC:44145,61451,44309,114800,62,23,29,335 05045 12/06/2025 22:35:36 Discharge cutback 58% 05046 12/06/2025 22:35:36 499A 05047 12/06/2025 22:36:36 Discharge level 046 AH, SOC: 25%, I:112A, L:3437, l:3581, H:3516, B:079, PT:035C, BT:024C, PV: 97953, M:Bike On 05048 12/06/2025 22:36:36 SOC:46657,62170,46830,114800,60,36,25,255 05049 12/06/2025 22:36:36 Discharge cutback 56% 05050 12/06/2025 22:36:37 486A 05051 12/06/2025 22:37:36 Discharge level 049 AH, SOC: 21%, I: 1A, L:3517, l:3622, H:3568, B:051, PT:035C, BT:024C, PV: 99594, M:Bike On 05052 12/06/2025 22:37:36 SOC:49413,62502,49615,114800,57,44,21,183 05053 12/06/2025 22:37:36 Discharge cutback 51% 05054 12/06/2025 22:37:37 442A 05055 12/06/2025 22:38:36 Discharge level 050 AH, SOC: 23%, I: 0A, L:3555, l:3626, H:3595, B:040, PT:036C, BT:024C, PV:100444, M:Bike On 05056 12/06/2025 22:38:36 SOC:49576,63859,50501,114800,57,46,23,128 05057 12/06/2025 22:38:36 Discharge cutback 64% 05058 12/06/2025 22:38:37 546A 05059 12/06/2025 22:39:36 Discharge level 051 AH, SOC: 26%, I:-15A, L:3589, l:3638, H:3619, B:030, PT:036C, BT:024C, PV:101182, M:Bike On 05060 12/06/2025 22:39:36 SOC:49539,66062,51006,114800,56,47,26,89 05061 12/06/2025 22:39:36 Discharge cutback 71% 05062 12/06/2025 22:39:37 611A 05063 12/06/2025 22:40:36 Discharge level 051 AH, SOC: 28%, I: 1A, L:3593, l:3632, H:3622, B:029, PT:036C, BT:023C, PV:101269, M:Bike On 05064 12/06/2025 22:40:36 SOC:49346,67980,51404,114800,56,47,28,71 05065 12/06/2025 22:40:37 Discharge cutback 76% 05066 12/06/2025 22:40:37 655A 05067 12/06/2025 22:41:36 Discharge level 051 AH, SOC: 30%, I: 40A, L:3571, l:3616, H:3606, B:035, PT:036C, BT:024C, PV:100767, M:Bike On 05068 12/06/2025 22:41:36 SOC:48854,69163,51710,114800,55,44,30,82 05069 12/06/2025 22:41:37 Discharge cutback 78% 05070 12/06/2025 22:41:37 675A 05071 12/06/2025 22:42:36 Discharge level 051 AH, SOC: 32%, I: 0A, L:3613, l:3633, H:3635, B:022, PT:036C, BT:026C, PV:101669, M:Bike On 05072 12/06/2025 22:42:36 SOC:48022,69698,51814,114800,55,47,32,37 05073 12/06/2025 22:42:37 Discharge cutback 81% 05074 12/06/2025 22:42:37 698A 05075 12/06/2025 22:43:36 Discharge level 051 AH, SOC: 33%, I: 0A, L:3619, l:3632, H:3640, B:021, PT:036C, BT:026C, PV:101828, M:Bike On 05076 12/06/2025 22:43:37 SOC:47037,69864,51819,114800,55,47,33,25 05077 12/06/2025 22:43:37 Discharge cutback 83% 05078 12/06/2025 22:43:37 715A 05079 12/06/2025 22:44:18 DEBUG: Entered Charging State 05080 12/06/2025 22:44:18 DEBUG: CAN NOT Receiving Syncs 05081 12/06/2025 22:44:19 Discharge level 051 AH, SOC: 34%, I: 0A, L:3623, l:3633, H:3643, B:020, PT:036C, BT:025C, PV:101897, M:Charge 05082 12/06/2025 22:44:19 SOC:46372,69864,51819,114800,55,47,34,20 05083 12/06/2025 22:44:19 DEBUG: CAN Link Is Down 05084 12/06/2025 22:44:19 DEBUG: CAN Link Is Up 05085 12/06/2025 22:44:19 Contactor was Opened Pack V: 101899mV, Switched V: 101848mV, Prechg Pct: 100%, Dischg Cur: 545mA 05086 12/06/2025 22:44:19 DEBUG: CAN Receiving Syncs 05087 12/06/2025 22:44:21 DEBUG: Entered Running State 05088 12/06/2025 22:44:21 DEBUG: CAN NOT Receiving Syncs 05089 12/06/2025 22:44:22 System Turned Off 05090 12/06/2025 22:44:22 Discharge level 051 AH, SOC: 34%, I: 0A, L:3623, l:3633, H:3643, B:020, PT:036C, BT:025C, PV:101909, M:Bike On 05091 12/06/2025 22:44:22 SOC:46357,69864,51819,114800,55,47,34,19 05092 12/06/2025 22:44:22 Discharge cutback 84% 05093 12/06/2025 22:44:22 722A 05094 12/06/2025 22:44:23 DEBUG: CAN Receiving Syncs 05095 12/06/2025 22:44:23 DEBUG: CAN Link Is Down 05096 12/06/2025 22:44:23 DEBUG: Entered Idle State 05097 12/06/2025 22:44:25 System Turned On 05098 12/06/2025 22:44:25 Rev:45,Build:2023-05-20_045619 958 banka 05099 12/06/2025 22:44:25 Pack:2019_monolith,Numbricks:4 05100 12/06/2025 22:44:25 DEBUG: Entered Running State 05101 12/06/2025 22:44:25 DEBUG: CAN NOT Receiving Syncs 05102 12/06/2025 22:44:25 DEBUG: CAN Link Is Up 05103 12/06/2025 22:44:26 DEBUG: Resetting CAN0 due to error passive mode 05104 12/06/2025 22:44:29 DEBUG: CAN Receiving Syncs 05105 12/06/2025 22:44:29 Contactor drive turned on Pack V: 101914mV, Switched V: 90427mV, Duty Cycle: 39% 05106 12/06/2025 22:44:29 Contactor was Closed Pack V: 101914mV, Switched V: 90427mV, Prechg Pct: 89%, Dischg Cur: 272mA 05107 12/06/2025 22:44:39 DEBUG: Entered Charging State 05108 12/06/2025 22:44:39 DEBUG: CAN NOT Receiving Syncs 05109 12/06/2025 22:44:40 Discharge level 051 AH, SOC: 34%, I: 0A, L:3624, l:3633, H:3644, B:020, PT:036C, BT:026C, PV:101929, M:Charge 05110 12/06/2025 22:44:40 SOC:46126,69870,51819,114800,55,47,34,18 05111 12/06/2025 22:44:41 DEBUG: CAN Receiving Syncs 05112 12/06/2025 22:54:40 Discharge level 049 AH, SOC: 47%, I:-12A, L:3673, l:3662, H:3682, B:009, PT:035C, BT:026C, PV:103038, M:Charge 05113 12/06/2025 22:54:40 SOC:30226,56153,49745,114800,57,52,47,-21 05114 12/06/2025 23:04:40 Discharge level 047 AH, SOC: 54%, I:-11A, L:3689, l:3677, H:3698, B:009, PT:035C, BT:030C, PV:103501, M:Charge 05115 12/06/2025 23:04:41 SOC:24545,52543,47688,114800,59,54,54,-22 05116 12/06/2025 23:14:40 Discharge level 045 AH, SOC: 58%, I:-12A, L:3706, l:3693, H:3712, B:006, PT:034C, BT:038C, PV:103894, M:Charge 05117 12/06/2025 23:14:41 SOC:22580,52624,45658,114800,61,56,58,-23 05118 12/06/2025 23:24:48 Discharge level 043 AH, SOC: 60%, I:-11A, L:3723, l:3710, H:3727, B:004, PT:034C, BT:041C, PV:104318, M:Charge 05119 12/06/2025 23:24:48 SOC:21721,53818,43622,114800,63,59,60,-22 05120 12/06/2025 23:34:48 Discharge level 041 AH, SOC: 62%, I:-11A, L:3738, l:3725, H:3742, B:004, PT:033C, BT:042C, PV:104734, M:Charge 05121 12/06/2025 23:34:48 SOC:21145,55238,41644,114800,64,61,62,-22 05122 12/06/2025 23:44:48 Discharge level 039 AH, SOC: 64%, I:-11A, L:3754, l:3741, H:3758, B:004, PT:033C, BT:043C, PV:105185, M:Charge 05123 12/06/2025 23:44:48 SOC:20696,56757,39693,114800,66,63,64,-22 05124 12/06/2025 23:54:48 Discharge level 037 AH, SOC: 66%, I:-11A, L:3771, l:3757, H:3777, B:006, PT:033C, BT:044C, PV:105661, M:Charge 05125 12/06/2025 23:54:48 SOC:20111,58141,37741,114800,68,65,66,-22 05126 12/07/2025 00:04:48 Discharge level 035 AH, SOC: 68%, I:-11A, L:3788, l:3774, H:3797, B:009, PT:033C, BT:044C, PV:106174, M:Charge 05127 12/07/2025 00:04:48 SOC:19502,59498,35792,114800,69,66,68,-21 05128 12/07/2025 00:14:48 Discharge level 033 AH, SOC: 70%, I:-11A, L:3807, l:3793, H:3815, B:008, PT:032C, BT:042C, PV:106687, M:Charge 05129 12/07/2025 00:14:48 SOC:18688,60611,33884,114800,71,69,70,-21 05130 12/07/2025 00:24:48 Discharge level 032 AH, SOC: 72%, I:-11A, L:3827, l:3813, H:3835, B:008, PT:032C, BT:042C, PV:107247, M:Charge 05131 12/07/2025 00:24:48 SOC:17805,61627,32003,114800,73,71,72,-21 05132 12/07/2025 00:34:56 Discharge level 030 AH, SOC: 74%, I:-11A, L:3849, l:3835, H:3858, B:009, PT:032C, BT:042C, PV:107863, M:Charge 05133 12/07/2025 00:34:56 SOC:16727,62499,30073,114800,74,73,74,-21 05134 12/07/2025 00:44:56 Discharge level 028 AH, SOC: 76%, I:-10A, L:3872, l:3858, H:3879, B:007, PT:032C, BT:043C, PV:108491, M:Charge 05135 12/07/2025 00:44:56 SOC:15469,63175,28157,114800,76,75,76,-21 05136 12/07/2025 00:54:56 Discharge level 026 AH, SOC: 78%, I:-11A, L:3896, l:3882, H:3900, B:004, PT:031C, BT:044C, PV:109132, M:Charge 05137 12/07/2025 00:54:56 SOC:14237,63868,26250,114800,78,77,78,-21 05138 12/07/2025 01:04:56 Discharge level 024 AH, SOC: 80%, I:-11A, L:3917, l:3903, H:3920, B:003, PT:031C, BT:045C, PV:109733, M:Charge 05139 12/07/2025 01:04:56 SOC:13045,64585,24361,114800,79,79,80,-21 05140 12/07/2025 01:14:56 Discharge level 022 AH, SOC: 82%, I:-11A, L:3937, l:3923, H:3941, B:004, PT:031C, BT:048C, PV:110317, M:Charge 05141 12/07/2025 01:14:56 SOC:11935,65387,22468,114800,81,81,82,-21 05142 12/07/2025 01:24:56 Discharge level 020 AH, SOC: 84%, I:-11A, L:3957, l:3943, H:3960, B:003, PT:031C, BT:048C, PV:110856, M:Charge 05143 12/07/2025 01:24:56 SOC:10952,66271,20619,114800,83,83,84,-21 05144 12/07/2025 01:34:56 Discharge level 018 AH, SOC: 86%, I:-11A, L:3975, l:3962, H:3979, B:004, PT:030C, BT:046C, PV:111372, M:Charge 05145 12/07/2025 01:34:56 SOC:9868,67047,18779,114800,84,85,86,-21 05146 12/07/2025 01:45:04 Discharge level 016 AH, SOC: 87%, I:-11A, L:3994, l:3980, H:3998, B:004, PT:030C, BT:042C, PV:111894, M:Charge 05147 12/07/2025 01:45:04 SOC:8968,68005,16940,114800,86,86,87,-20 05148 12/07/2025 01:55:04 Discharge level 015 AH, SOC: 89%, I:-10A, L:4013, l:4000, H:4016, B:003, PT:030C, BT:040C, PV:112411, M:Charge 05149 12/07/2025 01:55:04 SOC:7832,68694,15135,114800,87,88,89,-20 05150 12/07/2025 02:01:09 Charged To Full 014 AH, SOC: 90%, L:4025, H:4027, B:002, PT:030C, BT:037C, PV:112733 05151 12/07/2025 02:01:10 SOC adjusted for voltage old: 7167617uAH (soc:90%), new: 6913977uAH (soc:90%), low cell: 4025 mV 05152 12/07/2025 02:05:04 Discharge level 010 AH, SOC: 91%, I:-10A, L:4032, l:4019, H:4035, B:003, PT:029C, BT:036C, PV:112933, M:Charge 05153 12/07/2025 02:05:04 SOC:6570,69506,10777,114800,91,90,91,-19 05154 12/07/2025 02:15:04 Discharge level 008 AH, SOC: 93%, I:-10A, L:4051, l:4038, H:4054, B:003, PT:029C, BT:033C, PV:113464, M:Charge 05155 12/07/2025 02:15:04 SOC:5537,70272,8998,114800,93,92,93,-20 05156 12/07/2025 02:25:04 Discharge level 007 AH, SOC: 94%, I:-10A, L:4070, l:4057, H:4073, B:003, PT:029C, BT:033C, PV:114005, M:Charge 05157 12/07/2025 02:25:04 SOC:4392,70929,7215,114800,94,94,94,-20 05158 12/07/2025 02:35:04 Discharge level 005 AH, SOC: 96%, I:-10A, L:4089, l:4076, H:4092, B:003, PT:029C, BT:032C, PV:114529, M:Charge 05159 12/07/2025 02:35:04 SOC:3119,71446,5446,114800,96,95,96,-20 05160 12/07/2025 03:21:15 DEBUG: CAN Link Is Down 05161 12/07/2025 03:21:19 Contactor was Opened Pack V: 116105mV, Switched V: 116105mV, Prechg Pct: 100%, Dischg Cur: 272mA 05162 12/07/2025 03:21:19 DEBUG: CAN Link Is Up 05163 12/07/2025 03:21:21 System Turned Off 05164 12/07/2025 03:21:22 DEBUG: CAN Link Is Down 05165 12/07/2025 03:21:22 DEBUG: Entered Idle State 05166 12/07/2025 03:21:28 Current Sensor Zeroed old: 2507mV, new: 2505mV, corrfact: 251 05167 12/07/2025 03:21:29 Discharge level 000 AH, SOC:100%, I: 0A, L:4148, l:4146, H:4152, B:004, PT:028C, BT:036C, PV:116051, M:Idle 05168 12/07/2025 03:21:29 SOC:0,72588,0,114800,100,100,100,-4 05169 12/07/2025 03:21:49 Voltage Across Contactor: 103222mV (Okay) 05170 12/07/2025 06:57:35 System Turned On 05171 12/07/2025 06:57:35 Rev:45,Build:2023-05-20_045619 958 banka 05172 12/07/2025 06:57:35 Pack:2019_monolith,Numbricks:4 05173 12/07/2025 06:57:35 DEBUG: Entered Charging State 05174 12/07/2025 06:57:35 DEBUG: CAN NOT Receiving Syncs 05175 12/07/2025 06:57:35 DEBUG: Entered Running State 05176 12/07/2025 06:57:35 DEBUG: CAN Link Is Up 05177 12/07/2025 06:57:36 DEBUG: Resetting CAN0 due to error passive mode 05178 12/07/2025 06:57:36 Discharge level 000 AH, SOC:100%, I: 0A, L:4128, l:4125, H:4130, B:002, PT:023C, BT:033C, PV:115634, M:Bike On 05179 12/07/2025 06:57:36 SOC:0,72588,0,114800,100,100,100,-3 05180 12/07/2025 06:57:39 DEBUG: CAN Receiving Syncs 05181 12/07/2025 06:57:44 Contactor drive turned on Pack V: 115630mV, Switched V: 101730mV, Duty Cycle: 34% 05182 12/07/2025 06:57:44 Contactor was Closed Pack V: 115630mV, Switched V: 101730mV, Prechg Pct: 88%, Dischg Cur: 454mA 05183 12/07/2025 06:58:36 Discharge level 000 AH, SOC:100%, I: 0A, L:4126, l:4126, H:4130, B:004, PT:023C, BT:031C, PV:115605, M:Bike On 05184 12/07/2025 06:58:37 SOC:5,72581,8,114800,100,100,100,0 05185 12/07/2025 06:59:36 Discharge level 000 AH, SOC:100%, I:201A, L:3787, l:3921, H:3840, B:053, PT:023C, BT:031C, PV:106836, M:Bike On 05186 12/07/2025 06:59:37 SOC:472,71993,483,114800,100,80,100,174 05187 12/07/2025 07:00:37 Discharge level 000 AH, SOC: 99%, I:-17A, L:4125, l:4133, H:4130, B:005, PT:023C, BT:031C, PV:115560, M:Bike On 05188 12/07/2025 07:00:37 SOC:885,71368,921,114800,100,100,99,10 05189 12/07/2025 07:01:37 Discharge level 001 AH, SOC: 99%, I: 2A, L:4100, l:4112, H:4106, B:006, PT:023C, BT:030C, PV:114915, M:Bike On 05190 12/07/2025 07:01:37 SOC:1006,70999,1085,114800,100,99,99,16 05191 12/07/2025 07:02:37 Discharge level 001 AH, SOC: 98%, I:266A, L:3709, l:3879, H:3771, B:062, PT:023C, BT:029C, PV:104795, M:Bike On 05192 12/07/2025 07:02:37 SOC:1446,70219,1619,114800,99,76,98,219 05193 12/07/2025 07:03:37 Discharge level 003 AH, SOC: 96%, I:164A, L:3759, l:3932, H:3812, B:053, PT:024C, BT:029C, PV:106097, M:Bike On 05194 12/07/2025 07:03:37 SOC:3366,68313,3545,114800,97,82,96,230 05195 12/07/2025 07:04:37 Discharge level 005 AH, SOC: 92%, I:168A, L:3716, l:3918, H:3772, B:056, PT:025C, BT:029C, PV:104960, M:Bike On 05196 12/07/2025 07:04:37 SOC:5585,66325,5781,114800,95,80,92,264 05197 12/07/2025 07:05:37 Discharge level 007 AH, SOC: 89%, I:-24A, L:3980, l:4037, H:3995, B:015, PT:025C, BT:029C, PV:111754, M:Bike On 05198 12/07/2025 07:05:37 SOC:7221,65171,7446,114800,94,91,89,76 05199 12/07/2025 07:06:37 Discharge level 008 AH, SOC: 88%, I:-39A, L:3986, l:4056, H:3999, B:013, PT:026C, BT:029C, PV:111884, M:Bike On 05200 12/07/2025 07:06:37 SOC:7979,64570,8288,114800,93,93,88,96 05201 12/07/2025 07:07:37 Discharge level 008 AH, SOC: 88%, I: 1A, L:3970, l:4005, H:3988, B:018, PT:026C, BT:029C, PV:111529, M:Bike On 05202 12/07/2025 07:07:37 SOC:8206,64335,8645,114800,93,88,88,48 05203 12/07/2025 07:08:37 Discharge level 008 AH, SOC: 88%, I: 0A, L:3988, l:4006, H:4003, B:015, PT:027C, BT:029C, PV:111965, M:Bike On 05204 12/07/2025 07:08:37 SOC:8029,64248,8635,114800,93,89,88,25 05205 12/07/2025 07:09:37 Discharge level 009 AH, SOC: 87%, I: 48A, L:3925, l:3979, H:3949, B:024, PT:027C, BT:029C, PV:110365, M:Bike On 05206 12/07/2025 07:09:37 SOC:8433,64022,9114,114800,93,86,87,74 05207 12/07/2025 07:10:37 Discharge level 009 AH, SOC: 86%, I:101A, L:3838, l:3923, H:3877, B:039, PT:027C, BT:029C, PV:108185, M:Bike On 05208 12/07/2025 07:10:37 SOC:9159,63772,9864,114800,92,81,86,116 05209 12/07/2025 07:11:37 Discharge level 010 AH, SOC: 85%, I: 1A, L:3956, l:3986, H:3972, B:016, PT:027C, BT:029C, PV:111094, M:Bike On 05210 12/07/2025 07:11:37 SOC:9763,63559,10522,114800,91,87,85,41 05211 12/07/2025 07:12:37 Discharge level 011 AH, SOC: 84%, I: 75A, L:3855, l:3923, H:3891, B:036, PT:027C, BT:029C, PV:108604, M:Bike On 05212 12/07/2025 07:12:37 SOC:10273,63095,11243,114800,91,81,84,96 05213 12/07/2025 07:13:37 Discharge level 011 AH, SOC: 84%, I: 54A, L:3871, l:3937, H:3901, B:030, PT:027C, BT:028C, PV:108958, M:Bike On 05214 12/07/2025 07:13:37 SOC:10511,62993,11609,114800,90,82,84,92 05215 12/07/2025 07:14:37 Discharge level 012 AH, SOC: 83%, I:489A, L:3422, l:3705, H:3535, B:113, PT:027C, BT:029C, PV: 97772, M:Bike On 05216 12/07/2025 07:14:37 SOC:10970,62791,12210,114800,90,58,83,393 05217 12/07/2025 07:15:37 Discharge level 013 AH, SOC: 82%, I: 1A, L:3905, l:3959, H:3925, B:020, PT:028C, BT:029C, PV:109741, M:Bike On 05218 12/07/2025 07:15:37 SOC:11875,62602,13149,114800,89,84,82,75 05219 12/07/2025 07:16:37 Discharge level 013 AH, SOC: 81%, I:-25A, L:3957, l:3972, H:3968, B:011, PT:028C, BT:029C, PV:111023, M:Bike On 05220 12/07/2025 07:16:37 SOC:12077,62520,13535,114800,89,85,81,21 05221 12/07/2025 07:17:37 Discharge level 014 AH, SOC: 80%, I: 1A, L:3924, l:3948, H:3940, B:016, PT:028C, BT:029C, PV:110200, M:Bike On 05222 12/07/2025 07:17:37 SOC:12544,62597,14077,114800,88,83,80,33 05223 12/07/2025 07:18:37 Discharge level 014 AH, SOC: 80%, I: 2A, L:3928, l:3950, H:3944, B:016, PT:028C, BT:028C, PV:110309, M:Bike On 05224 12/07/2025 07:18:37 SOC:12629,62737,14305,114800,88,84,80,31 05225 12/07/2025 07:19:37 Discharge level 014 AH, SOC: 80%, I: 29A, L:3896, l:3927, H:3918, B:022, PT:028C, BT:029C, PV:109527, M:Bike On 05226 12/07/2025 07:19:37 SOC:12733,62831,14571,114800,88,81,80,44 05227 12/07/2025 07:20:37 Discharge level 015 AH, SOC: 80%, I: 1A, L:3920, l:3936, H:3936, B:016, PT:029C, BT:029C, PV:110103, M:Bike On 05228 12/07/2025 07:20:37 SOC:13007,62343,15186,114800,87,82,80,23 05229 12/07/2025 07:21:37 Discharge level 015 AH, SOC: 80%, I: 1A, L:3932, l:3941, H:3945, B:013, PT:029C, BT:029C, PV:110379, M:Bike On 05230 12/07/2025 07:21:37 SOC:13033,62881,15213,114800,87,83,80,13 05231 12/07/2025 07:22:37 Discharge level 015 AH, SOC: 79%, I:240A, L:3606, l:3781, H:3679, B:073, PT:029C, BT:029C, PV:102285, M:Bike On 05232 12/07/2025 07:22:37 SOC:13717,63028,15921,114800,87,66,79,246 05233 12/07/2025 07:23:37 Discharge level 017 AH, SOC: 77%, I: 1A, L:3843, l:3894, H:3869, B:026, PT:029C, BT:030C, PV:108116, M:Bike On 05234 12/07/2025 07:23:37 SOC:14788,62748,17132,114800,86,78,77,71 05235 12/07/2025 07:24:37 Discharge level 017 AH, SOC: 76%, I: 0A, L:3871, l:3909, H:3889, B:018, PT:029C, BT:030C, PV:108758, M:Bike On 05236 12/07/2025 07:24:37 SOC:15237,62519,17835,114800,85,80,76,54 05237 12/07/2025 07:25:37 Discharge level 018 AH, SOC: 76%, I: 1A, L:3883, l:3907, H:3901, B:018, PT:030C, BT:030C, PV:109104, M:Bike On 05238 12/07/2025 07:25:37 SOC:15328,62676,18116,114800,85,80,76,33 05239 12/07/2025 07:26:37 Discharge level 018 AH, SOC: 76%, I: -3A, L:3903, l:3912, H:3917, B:014, PT:030C, BT:030C, PV:109583, M:Bike On 05240 12/07/2025 07:26:37 SOC:15224,62992,18189,114800,85,80,76,12 05241 12/07/2025 07:27:37 Discharge level 018 AH, SOC: 76%, I: 39A, L:3836, l:3878, H:3861, B:025, PT:030C, BT:030C, PV:107909, M:Bike On 05242 12/07/2025 07:27:37 SOC:15680,63016,18801,114800,84,77,76,61 05243 12/07/2025 07:28:37 Discharge level 018 AH, SOC: 76%, I: 1A, L:3893, l:3903, H:3907, B:014, PT:030C, BT:029C, PV:109290, M:Bike On 05244 12/07/2025 07:28:37 SOC:15761,63624,18893,114800,84,79,76,15 05245 12/07/2025 07:29:08 Contactor was Opened Pack V: 109393mV, Switched V: 109292mV, Prechg Pct: 100%, Dischg Cur: 818mA 05246 12/07/2025 07:29:08 System Turned Off 05247 12/07/2025 07:29:09 DEBUG: CAN Link Is Down 05248 12/07/2025 07:29:09 DEBUG: Entered Idle State 05249 12/07/2025 07:29:16 Discharge level 018 AH, SOC: 76%, I: 0A, L:3898, l:3905, H:3912, B:014, PT:030C, BT:030C, PV:109321, M:Idle 05250 12/07/2025 07:29:16 SOC:15764,63944,18907,114800,84,79,76,10 05251 12/07/2025 07:29:38 Voltage Across Contactor: 96500mV (Okay) 05252 12/07/2025 07:58:47 System Turned On 05253 12/07/2025 07:58:47 Rev:45,Build:2023-05-20_045619 958 banka 05254 12/07/2025 07:58:47 Pack:2019_monolith,Numbricks:4 05255 12/07/2025 07:58:47 DEBUG: Entered Running State 05256 12/07/2025 07:58:47 DEBUG: CAN NOT Receiving Syncs 05257 12/07/2025 07:58:48 DEBUG: CAN Link Is Up 05258 12/07/2025 07:58:48 DEBUG: Resetting CAN0 due to error passive mode 05259 12/07/2025 07:58:48 Discharge level 018 AH, SOC: 76%, I: 0A, L:3918, l:3925, H:3928, B:010, PT:029C, BT:041C, PV:109912, M:Bike On 05260 12/07/2025 07:58:48 SOC:15760,63944,18907,114800,84,81,76,10 05261 12/07/2025 07:58:51 DEBUG: CAN Receiving Syncs 05262 12/07/2025 07:58:52 Contactor drive turned on Pack V: 109902mV, Switched V: 96256mV, Duty Cycle: 36% 05263 12/07/2025 07:58:52 Contactor was Closed Pack V: 109902mV, Switched V: 96256mV, Prechg Pct: 88%, Dischg Cur: 727mA 05264 12/07/2025 07:59:48 Discharge level 018 AH, SOC: 76%, I: 1A, L:3917, l:3922, H:3927, B:010, PT:029C, BT:040C, PV:109888, M:Bike On 05265 12/07/2025 07:59:48 SOC:15756,64847,18925,114800,84,81,76,7 05266 12/07/2025 08:00:48 Discharge level 019 AH, SOC: 76%, I: 1A, L:3897, l:3910, H:3909, B:012, PT:029C, BT:039C, PV:109376, M:Bike On 05267 12/07/2025 08:00:48 SOC:15952,65305,19248,114800,84,80,76,18 05268 12/07/2025 08:01:48 Discharge level 019 AH, SOC: 76%, I: -8A, L:3909, l:3916, H:3919, B:010, PT:029C, BT:037C, PV:109652, M:Bike On 05269 12/07/2025 08:01:48 SOC:16098,65685,19521,114800,83,80,76,11 05270 12/07/2025 08:02:48 Discharge level 019 AH, SOC: 76%, I:-10A, L:3899, l:3914, H:3909, B:010, PT:029C, BT:037C, PV:109370, M:Bike On 05271 12/07/2025 08:02:48 SOC:16314,66098,19834,114800,83,80,76,22 05272 12/07/2025 08:03:39 Contactor was Opened Pack V: 109388mV, Switched V: 109292mV, Prechg Pct: 100%, Dischg Cur: 727mA 05273 12/07/2025 08:03:40 System Turned Off 05274 12/07/2025 08:03:40 DEBUG: CAN Link Is Down 05275 12/07/2025 08:03:41 DEBUG: Entered Idle State 05276 12/07/2025 08:03:46 Current Sensor Zeroed old: 2505mV, new: 2504mV, corrfact: 252 05277 12/07/2025 08:03:47 SOC adjusted for voltage old: 16236647uAH (soc:76%), new: 13965010uAH (soc:79%), low cell: 3900 mV 05278 12/07/2025 08:03:48 Discharge level 024 AH, SOC: 79%, I: 0A, L:3900, l:3906, H:3911, B:011, PT:029C, BT:035C, PV:109342, M:Idle 05279 12/07/2025 08:03:48 SOC:13965,66500,24108,114800,79,80,79,8 05280 12/07/2025 08:04:09 Voltage Across Contactor: 96247mV (Okay) 05281 12/07/2025 08:38:37 System Turned On 05282 12/07/2025 08:38:37 Rev:45,Build:2023-05-20_045619 958 banka 05283 12/07/2025 08:38:37 Pack:2019_monolith,Numbricks:4 05284 12/07/2025 08:38:37 DEBUG: Entered Running State 05285 12/07/2025 08:38:37 DEBUG: CAN NOT Receiving Syncs 05286 12/07/2025 08:38:37 DEBUG: CAN Link Is Up 05287 12/07/2025 08:38:38 DEBUG: Resetting CAN0 due to error passive mode 05288 12/07/2025 08:38:38 Discharge level 024 AH, SOC: 76%, I: 0A, L:3912, l:3918, H:3920, B:008, PT:028C, BT:040C, PV:109707, M:Bike On 05289 12/07/2025 08:38:38 SOC:16233,66500,24108,114800,79,81,76,8 05290 12/07/2025 08:38:41 DEBUG: CAN Receiving Syncs 05291 12/07/2025 08:38:42 Contactor drive turned on Pack V: 109700mV, Switched V: 95940mV, Duty Cycle: 36% 05292 12/07/2025 08:38:42 Contactor was Closed Pack V: 109700mV, Switched V: 95940mV, Prechg Pct: 87%, Dischg Cur: 636mA 05293 12/07/2025 08:39:38 Discharge level 024 AH, SOC: 76%, I: 0A, L:3911, l:3915, H:3919, B:008, PT:028C, BT:039C, PV:109691, M:Bike On 05294 12/07/2025 08:39:38 SOC:16066,66802,24115,114800,79,80,76,5 05295 12/07/2025 08:40:38 Discharge level 024 AH, SOC: 77%, I: 1A, L:3911, l:3914, H:3919, B:008, PT:028C, BT:038C, PV:109693, M:Bike On 05296 12/07/2025 08:40:38 SOC:15973,67234,24126,114800,79,80,77,4 05297 12/07/2025 08:41:38 Discharge level 024 AH, SOC: 77%, I: 1A, L:3911, l:3913, H:3919, B:008, PT:028C, BT:037C, PV:109686, M:Bike On 05298 12/07/2025 08:41:38 SOC:15899,67670,24138,114800,79,80,77,3 05299 12/07/2025 08:42:38 Discharge level 024 AH, SOC: 77%, I: 1A, L:3910, l:3912, H:3919, B:009, PT:028C, BT:037C, PV:109683, M:Bike On 05300 12/07/2025 08:42:38 SOC:15807,68017,24148,114800,79,80,77,3 05301 12/07/2025 08:43:38 Discharge level 024 AH, SOC: 77%, I: 9A, L:3899, l:3908, H:3908, B:009, PT:028C, BT:036C, PV:109365, M:Bike On 05302 12/07/2025 08:43:38 SOC:15899,68405,24294,114800,79,80,77,13 05303 12/07/2025 08:44:38 Discharge level 024 AH, SOC: 77%, I: 3A, L:3836, l:3864, H:3853, B:017, PT:028C, BT:035C, PV:107714, M:Bike On 05304 12/07/2025 08:44:38 SOC:16243,68675,24668,114800,79,75,77,39 05305 12/07/2025 08:45:38 Discharge level 025 AH, SOC: 76%, I: 85A, L:3758, l:3836, H:3785, B:027, PT:028C, BT:035C, PV:105698, M:Bike On 05306 12/07/2025 08:45:38 SOC:16967,68582,25449,114800,78,73,76,110 05307 12/07/2025 08:46:38 Discharge level 026 AH, SOC: 74%, I:103A, L:3708, l:3813, H:3739, B:031, PT:028C, BT:033C, PV:104351, M:Bike On 05308 12/07/2025 08:46:38 SOC:18167,68313,26657,114800,77,70,74,147 05309 12/07/2025 08:47:38 Discharge level 027 AH, SOC: 72%, I: 2A, L:3809, l:3863, H:3821, B:012, PT:028C, BT:033C, PV:106901, M:Bike On 05310 12/07/2025 08:47:38 SOC:19135,68191,27643,114800,76,75,72,76 05311 12/07/2025 08:48:38 Discharge level 028 AH, SOC: 71%, I: 72A, L:3716, l:3812, H:3740, B:024, PT:028C, BT:033C, PV:104471, M:Bike On 05312 12/07/2025 08:48:38 SOC:20184,68018,28730,114800,75,70,71,135 05313 12/07/2025 08:49:38 Discharge level 029 AH, SOC: 69%, I: 1A, L:3791, l:3837, H:3802, B:011, PT:028C, BT:032C, PV:106373, M:Bike On 05314 12/07/2025 08:49:38 SOC:21190,67787,29837,114800,75,73,69,64 05315 12/07/2025 08:50:38 Discharge level 030 AH, SOC: 69%, I: 11A, L:3791, l:3826, H:3801, B:010, PT:028C, BT:032C, PV:106336, M:Bike On 05316 12/07/2025 08:50:38 SOC:21572,67762,30393,114800,74,72,69,50 05317 12/07/2025 08:51:38 Discharge level 030 AH, SOC: 68%, I: 83A, L:3717, l:3782, H:3740, B:023, PT:028C, BT:032C, PV:104476, M:Bike On 05318 12/07/2025 08:51:38 SOC:21822,67923,30786,114800,74,67,68,91 05319 12/07/2025 08:52:38 Discharge level 031 AH, SOC: 68%, I:124A, L:3655, l:3746, H:3687, B:032, PT:028C, BT:031C, PV:102904, M:Bike On 05320 12/07/2025 08:52:38 SOC:22113,67977,31239,114800,73,63,68,128 05321 12/07/2025 08:53:38 Discharge level 031 AH, SOC: 67%, I:-18A, L:3799, l:3822, H:3805, B:006, PT:029C, BT:031C, PV:106467, M:Bike On 05322 12/07/2025 08:53:38 SOC:22482,67377,31909,114800,73,71,67,32 05323 12/07/2025 08:54:38 Discharge level 032 AH, SOC: 67%, I: 30A, L:3748, l:3794, H:3762, B:014, PT:029C, BT:031C, PV:105222, M:Bike On 05324 12/07/2025 08:54:38 SOC:22904,67641,32368,114800,72,68,67,66 05325 12/07/2025 08:55:38 Discharge level 033 AH, SOC: 66%, I: 1A, L:3773, l:3799, H:3781, B:008, PT:029C, BT:031C, PV:105795, M:Bike On 05326 12/07/2025 08:55:38 SOC:23461,67659,33029,114800,72,69,66,37 05327 12/07/2025 08:56:38 Discharge level 033 AH, SOC: 66%, I: -8A, L:3784, l:3800, H:3790, B:006, PT:029C, BT:031C, PV:106074, M:Bike On 05328 12/07/2025 08:56:38 SOC:23678,67728,33408,114800,71,69,66,23 05329 12/07/2025 08:57:38 Discharge level 033 AH, SOC: 66%, I: 1A, L:3782, l:3795, H:3788, B:006, PT:029C, BT:031C, PV:106004, M:Bike On 05330 12/07/2025 08:57:38 SOC:23715,67969,33568,114800,71,68,66,19 05331 12/07/2025 08:58:38 Discharge level 033 AH, SOC: 66%, I: 1A, L:3788, l:3797, H:3794, B:006, PT:029C, BT:031C, PV:106158, M:Bike On 05332 12/07/2025 08:58:38 SOC:23723,68573,33590,114800,71,69,66,12 05333 12/07/2025 08:58:55 Contactor was Opened Pack V: 106199mV, Switched V: 106102mV, Prechg Pct: 100%, Dischg Cur: 1091mA 05334 12/07/2025 08:58:55 System Turned Off 05335 12/07/2025 08:58:56 DEBUG: CAN Link Is Down 05336 12/07/2025 08:58:56 DEBUG: Entered Idle State 05337 12/07/2025 08:59:02 Current Sensor Zeroed old: 2504mV, new: 2504mV, corrfact: 252 05338 12/07/2025 08:59:03 Discharge level 033 AH, SOC: 66%, I: 0A, L:3790, l:3797, H:3796, B:006, PT:029C, BT:031C, PV:106223, M:Idle 05339 12/07/2025 08:59:03 SOC:23715,68736,33594,114800,71,69,66,10 05340 12/07/2025 08:59:19 System Turned On 05341 12/07/2025 08:59:19 Rev:45,Build:2023-05-20_045619 958 banka 05342 12/07/2025 08:59:19 Pack:2019_monolith,Numbricks:4 05343 12/07/2025 08:59:19 DEBUG: Entered Running State 05344 12/07/2025 08:59:19 DEBUG: CAN NOT Receiving Syncs 05345 12/07/2025 08:59:19 DEBUG: CAN Link Is Up 05346 12/07/2025 08:59:20 DEBUG: Resetting CAN0 due to error passive mode 05347 12/07/2025 08:59:20 Discharge level 033 AH, SOC: 66%, I: 0A, L:3791, l:3798, H:3796, B:005, PT:029C, BT:031C, PV:106237, M:Bike On 05348 12/07/2025 08:59:20 SOC:23712,68736,33594,114800,71,69,66,10 05349 12/07/2025 08:59:23 DEBUG: CAN Receiving Syncs 05350 12/07/2025 08:59:24 Contactor drive turned on Pack V: 106238mV, Switched V: 93184mV, Duty Cycle: 37% 05351 12/07/2025 08:59:24 Contactor was Closed Pack V: 106238mV, Switched V: 93184mV, Prechg Pct: 88%, Dischg Cur: 545mA 05352 12/07/2025 08:59:26 DEBUG: Entered Charging State 05353 12/07/2025 08:59:26 DEBUG: CAN NOT Receiving Syncs 05354 12/07/2025 08:59:27 Discharge level 033 AH, SOC: 66%, I: 1A, L:3791, l:3798, H:3797, B:006, PT:029C, BT:031C, PV:106240, M:Charge 05355 12/07/2025 08:59:27 SOC:23699,68755,33595,114800,71,69,66,10 05356 12/07/2025 08:59:27 DEBUG: CAN Receiving Syncs 05357 12/07/2025 09:09:27 Discharge level 031 AH, SOC: 73%, I:-11A, L:3851, l:3836, H:3859, B:008, PT:029C, BT:037C, PV:107933, M:Charge 05358 12/07/2025 09:09:27 SOC:18255,65281,31668,114800,73,73,73,-21 05359 12/07/2025 09:19:27 Discharge level 029 AH, SOC: 76%, I:-11A, L:3882, l:3867, H:3887, B:005, PT:028C, BT:040C, PV:108762, M:Charge 05360 12/07/2025 09:19:27 SOC:15586,64497,29798,114800,75,76,76,-21 05361 12/07/2025 09:29:27 Discharge level 027 AH, SOC: 79%, I:-11A, L:3906, l:3892, H:3912, B:006, PT:028C, BT:041C, PV:109471, M:Charge 05362 12/07/2025 09:29:27 SOC:13915,64687,27954,114800,76,78,79,-20 05363 12/07/2025 09:39:34 Discharge level 026 AH, SOC: 81%, I:-11A, L:3929, l:3915, H:3934, B:005, PT:028C, BT:042C, PV:110118, M:Charge 05364 12/07/2025 09:39:34 SOC:12550,65189,26103,114800,78,80,81,-21 05365 12/07/2025 09:49:34 Discharge level 024 AH, SOC: 83%, I:-10A, L:3950, l:3936, H:3955, B:005, PT:028C, BT:042C, PV:110709, M:Charge 05366 12/07/2025 09:49:34 SOC:11406,65861,24306,114800,79,82,83,-20 05367 12/07/2025 09:59:34 Discharge level 022 AH, SOC: 85%, I:-10A, L:3971, l:3958, H:3975, B:004, PT:028C, BT:042C, PV:111268, M:Charge 05368 12/07/2025 09:59:34 SOC:10228,66494,22513,114800,81,84,85,-20 05369 12/07/2025 10:09:34 Discharge level 020 AH, SOC: 87%, I:-10A, L:3991, l:3977, H:3994, B:003, PT:028C, BT:042C, PV:111805, M:Charge 05370 12/07/2025 10:09:34 SOC:9059,67115,20741,114800,82,86,87,-20 05371 12/07/2025 10:19:34 Discharge level 018 AH, SOC: 89%, I:-10A, L:4010, l:3997, H:4013, B:003, PT:028C, BT:041C, PV:112343, M:Charge 05372 12/07/2025 10:19:34 SOC:7983,67807,18991,114800,84,88,89,-19 05373 12/07/2025 10:27:45 Charged To Full 017 AH, SOC: 90%, L:4026, H:4029, B:003, PT:027C, BT:040C, PV:112753 05374 12/07/2025 10:27:45 SOC adjusted for voltage old: 7095180uAH (soc:90%), new: 6154429uAH (soc:91%), low cell: 4026 mV 05375 12/07/2025 10:29:34 Discharge level 010 AH, SOC: 91%, I:-10A, L:4030, l:4017, H:4033, B:003, PT:027C, BT:039C, PV:112893, M:Charge 05376 12/07/2025 10:29:35 SOC:6256,68806,10013,114800,92,90,91,-20 05377 12/07/2025 10:39:34 Discharge level 008 AH, SOC: 92%, I:-10A, L:4050, l:4037, H:4053, B:003, PT:027C, BT:036C, PV:113445, M:Charge 05378 12/07/2025 10:39:34 SOC:5678,70015,8242,114800,93,92,92,-20 05379 12/07/2025 10:49:43 Discharge level 006 AH, SOC: 94%, I:-10A, L:4072, l:4059, H:4074, B:002, PT:027C, BT:033C, PV:114035, M:Charge 05380 12/07/2025 10:49:43 SOC:4259,70422,6435,114800,95,94,94,-20 05381 12/07/2025 10:59:43 Discharge level 004 AH, SOC: 96%, I:-10A, L:4091, l:4078, H:4094, B:003, PT:027C, BT:034C, PV:114597, M:Charge 05382 12/07/2025 10:59:43 SOC:3017,70964,4669,114800,96,96,96,-20 05383 12/07/2025 11:43:03 DEBUG: CAN Link Is Down 05384 12/07/2025 11:43:08 Contactor was Opened Pack V: 116080mV, Switched V: 116066mV, Prechg Pct: 100%, Dischg Cur: 545mA 05385 12/07/2025 11:43:08 DEBUG: CAN Link Is Up 05386 12/07/2025 11:43:10 System Turned Off 05387 12/07/2025 11:43:11 DEBUG: CAN Link Is Down 05388 12/07/2025 11:43:11 DEBUG: Entered Idle State 05389 12/07/2025 11:43:17 Current Sensor Zeroed old: 2504mV, new: 2505mV, corrfact: 251 05390 12/07/2025 11:43:18 Discharge level 000 AH, SOC:100%, I: 0A, L:4148, l:4146, H:4151, B:003, PT:026C, BT:035C, PV:116064, M:Idle 05391 12/07/2025 11:43:18 SOC:0,71791,0,114800,100,100,100,-3 05392 12/07/2025 11:43:38 Voltage Across Contactor: 103237mV (Okay) 05393 12/07/2025 14:18:56 DEBUG: Adjusted System time sec from 12/07/2025 14:19:56 (1765142396) to 12/07/2025 14:18:56 (1765142337) 05394 12/08/2025 12:15:16 Discharge level 000 AH, SOC:100%, I: 0A, L:4119, l:4116, H:4120, B:001, PT:016C, BT:022C, PV:115359, M:Idle 05395 12/08/2025 12:15:16 SOC:0,71791,0,114800,100,99,100,-3 05396 12/08/2025 12:15:18 Entering Hibernate 05397 12/08/2025 12:15:18 HDCR = 0x000C204E, HDSTAT = 0x00000000 05398 12/09/2025 05:13:24 Successfully Read Settings in 1 attempt(s) 05399 12/09/2025 05:13:24 Exiting Hibernate 05400 12/09/2025 05:13:24 DEBUG: Exiting Hibernate From Wake Pin 05401 12/09/2025 05:13:24 DEBUG: Entered Idle State 05402 12/09/2025 05:13:24 System Turned On 05403 12/09/2025 05:13:24 Rev:45,Build:2023-05-20_045619 958 banka 05404 12/09/2025 05:13:24 Pack:2019_monolith,Numbricks:4 05405 12/09/2025 05:13:24 DEBUG: Entered Running State 05406 12/09/2025 05:13:24 DEBUG: CAN Link Is Up 05407 12/09/2025 05:13:24 DEBUG: Resetting CAN0 due to error passive mode 05408 12/09/2025 05:13:25 DEBUG: CAN Link Is Down 05409 12/09/2025 05:13:25 DEBUG: CAN Link Is Up 05410 12/09/2025 05:13:25 Discharge level 000 AH, SOC:100%, I: 0A, L:4117, l:4117, H:4119, B:002, PT:015C, BT:014C, PV:115310, M:Bike On 05411 12/09/2025 05:13:25 SOC:0,71791,0,114800,100,99,100,0 05412 12/09/2025 05:13:27 DEBUG: CAN Receiving Syncs 05413 12/09/2025 05:13:32 Contactor drive turned on Pack V: 115291mV, Switched V: 101730mV, Duty Cycle: 34% 05414 12/09/2025 05:13:32 Contactor was Closed Pack V: 115291mV, Switched V: 101730mV, Prechg Pct: 88%, Dischg Cur: 272mA 05415 12/09/2025 05:14:25 Discharge level 000 AH, SOC:100%, I: 0A, L:4116, l:4116, H:4118, B:002, PT:015C, BT:014C, PV:115283, M:Bike On 05416 12/09/2025 05:14:25 SOC:67,71790,0,114800,100,99,100,0 05417 12/09/2025 05:15:25 Discharge level 000 AH, SOC:100%, I: 0A, L:4116, l:4117, H:4118, B:002, PT:015C, BT:015C, PV:115271, M:Bike On 05418 12/09/2025 05:15:25 SOC:127,71790,0,114800,100,99,100,1 05419 12/09/2025 05:16:25 Discharge level 000 AH, SOC:100%, I: 65A, L:3921, l:3986, H:3954, B:033, PT:015C, BT:016C, PV:110333, M:Bike On 05420 12/09/2025 05:16:25 SOC:306,71402,151,114800,100,87,100,56 05421 12/09/2025 05:17:25 Discharge level 000 AH, SOC:100%, I: 0A, L:4091, l:4111, H:4094, B:003, PT:015C, BT:016C, PV:114593, M:Bike On 05422 12/09/2025 05:17:25 SOC:625,70590,452,114800,100,99,100,17 05423 12/09/2025 05:18:25 Discharge level 000 AH, SOC: 99%, I: 0A, L:4102, l:4110, H:4106, B:004, PT:015C, BT:016C, PV:114923, M:Bike On 05424 12/09/2025 05:18:25 SOC:719,70131,563,114800,100,99,99,7 05425 12/09/2025 05:19:25 Discharge level 000 AH, SOC: 99%, I:-13A, L:4137, l:4133, H:4144, B:007, PT:015C, BT:017C, PV:115921, M:Bike On 05426 12/09/2025 05:19:25 SOC:770,69721,634,114800,100,100,99,-3 05427 12/09/2025 05:20:25 Discharge level 000 AH, SOC: 99%, I:108A, L:3905, l:3994, H:3940, B:035, PT:015C, BT:017C, PV:109902, M:Bike On 05428 12/09/2025 05:20:25 SOC:782,69515,659,114800,100,88,99,77 05429 12/09/2025 05:21:25 Discharge level 000 AH, SOC: 99%, I: 49A, L:3952, l:4008, H:3978, B:026, PT:015C, BT:018C, PV:111059, M:Bike On 05430 12/09/2025 05:21:25 SOC:983,68806,899,114800,100,89,99,48 05431 12/09/2025 05:22:25 Discharge level 002 AH, SOC: 97%, I:149A, L:3671, l:3882, H:3729, B:058, PT:015C, BT:018C, PV:103688, M:Bike On 05432 12/09/2025 05:22:25 SOC:2523,66567,2408,114800,98,77,97,193 05433 12/09/2025 05:22:25 Discharge cutback 84% 05434 12/09/2025 05:22:25 722A 05435 12/09/2025 05:23:25 Discharge level 004 AH, SOC: 93%, I: 79A, L:3756, l:3946, H:3801, B:045, PT:016C, BT:018C, PV:105883, M:Bike On 05436 12/09/2025 05:23:25 SOC:4639,63890,4520,114800,97,83,93,173 05437 12/09/2025 05:24:25 Discharge level 005 AH, SOC: 91%, I: 35A, L:3869, l:3977, H:3895, B:026, PT:017C, BT:019C, PV:108748, M:Bike On 05438 12/09/2025 05:24:25 SOC:5907,62490,5785,114800,95,86,91,103 05439 12/09/2025 05:25:25 Discharge level 007 AH, SOC: 87%, I: 46A, L:3709, l:3894, H:3752, B:043, PT:018C, BT:019C, PV:104532, M:Bike On 05440 12/09/2025 05:25:25 SOC:8004,60670,7928,114800,94,78,87,182 05441 12/09/2025 05:26:25 Discharge level 009 AH, SOC: 84%, I:-32A, L:3917, l:4044, H:3930, B:013, PT:019C, BT:020C, PV:109927, M:Bike On 05442 12/09/2025 05:26:25 SOC:9796,59251,9871,114800,92,91,84,123 05443 12/09/2025 05:26:25 Discharge cutback 84% 05444 12/09/2025 05:26:25 725A 05445 12/09/2025 05:27:25 Discharge level 011 AH, SOC: 80%, I:126A, L:3645, l:3849, H:3702, B:057, PT:020C, BT:020C, PV:103062, M:Bike On 05446 12/09/2025 05:27:25 SOC:11683,58314,11802,114800,90,74,80,224 05447 12/09/2025 05:28:25 Discharge level 013 AH, SOC: 77%, I:122A, L:3656, l:3843, H:3712, B:056, PT:021C, BT:021C, PV:103368, M:Bike On 05448 12/09/2025 05:28:25 SOC:13497,57733,13624,114800,89,72,77,203 05449 12/09/2025 05:29:25 Discharge level 014 AH, SOC: 76%, I: 32A, L:3819, l:3900, H:3850, B:031, PT:022C, BT:021C, PV:107505, M:Bike On 05450 12/09/2025 05:29:25 SOC:14183,57850,14399,114800,88,79,76,95 05451 12/09/2025 05:30:25 Discharge level 014 AH, SOC: 76%, I: 52A, L:3798, l:3881, H:3834, B:036, PT:022C, BT:020C, PV:107009, M:Bike On 05452 12/09/2025 05:30:25 SOC:14377,57989,14806,114800,88,77,76,100 05453 12/09/2025 05:31:25 Discharge level 015 AH, SOC: 76%, I: 14A, L:3878, l:3916, H:3898, B:020, PT:022C, BT:021C, PV:108981, M:Bike On 05454 12/09/2025 05:31:25 SOC:14483,58292,15100,114800,87,80,76,45 05455 12/09/2025 05:32:25 Discharge level 015 AH, SOC: 75%, I: 0A, L:3890, l:3917, H:3907, B:017, PT:022C, BT:022C, PV:109266, M:Bike On 05456 12/09/2025 05:32:25 SOC:14864,58689,15567,114800,87,81,75,33 05457 12/09/2025 05:33:25 Discharge level 016 AH, SOC: 74%, I: 1A, L:3869, l:3910, H:3888, B:019, PT:023C, BT:023C, PV:108703, M:Bike On 05458 12/09/2025 05:33:25 SOC:15592,58910,16361,114800,86,80,74,49 05459 12/09/2025 05:34:25 Discharge level 016 AH, SOC: 74%, I: 0A, L:3874, l:3902, H:3893, B:019, PT:023C, BT:022C, PV:108842, M:Bike On 05460 12/09/2025 05:34:25 SOC:15759,59449,16626,114800,86,79,74,34 05461 12/09/2025 05:35:25 Discharge level 016 AH, SOC: 74%, I: 0A, L:3889, l:3907, H:3905, B:016, PT:023C, BT:023C, PV:109234, M:Bike On 05462 12/09/2025 05:35:25 SOC:15765,59966,16775,114800,86,80,74,22 05463 12/09/2025 05:36:25 Discharge level 016 AH, SOC: 75%, I: 72A, L:3795, l:3851, H:3830, B:035, PT:023C, BT:024C, PV:106881, M:Bike On 05464 12/09/2025 05:36:25 SOC:15278,59877,16772,114800,86,74,75,70 05465 12/09/2025 05:37:25 Discharge level 017 AH, SOC: 74%, I:115A, L:3708, l:3826, H:3752, B:044, PT:023C, BT:024C, PV:104627, M:Bike On 05466 12/09/2025 05:37:25 SOC:15829,59638,17575,114800,85,72,74,145 05467 12/09/2025 05:38:25 Discharge level 017 AH, SOC: 74%, I: 1A, L:3862, l:3891, H:3881, B:019, PT:024C, BT:023C, PV:108533, M:Bike On 05468 12/09/2025 05:38:25 SOC:15921,59956,17834,114800,85,78,74,36 05469 12/09/2025 05:39:25 Discharge level 018 AH, SOC: 73%, I: 89A, L:3729, l:3819, H:3769, B:040, PT:024C, BT:024C, PV:105173, M:Bike On 05470 12/09/2025 05:39:25 SOC:16705,60126,18664,114800,84,71,73,110 05471 12/09/2025 05:40:25 Discharge level 019 AH, SOC: 72%, I: 1A, L:3854, l:3880, H:3869, B:015, PT:024C, BT:024C, PV:108227, M:Bike On 05472 12/09/2025 05:40:25 SOC:17223,60442,19252,114800,84,77,72,32 05473 12/09/2025 05:41:25 Discharge level 020 AH, SOC: 71%, I: 0A, L:3830, l:3870, H:3848, B:018, PT:024C, BT:025C, PV:107615, M:Bike On 05474 12/09/2025 05:41:25 SOC:17996,60461,20143,114800,83,76,71,49 05475 12/09/2025 05:42:25 Discharge level 020 AH, SOC: 71%, I: 0A, L:3837, l:3869, H:3853, B:016, PT:024C, BT:024C, PV:107761, M:Bike On 05476 12/09/2025 05:42:25 SOC:18204,60708,20544,114800,83,76,71,39 05477 12/09/2025 05:43:25 Discharge level 021 AH, SOC: 70%, I:113A, L:3678, l:3788, H:3721, B:043, PT:024C, BT:024C, PV:103756, M:Bike On 05478 12/09/2025 05:43:25 SOC:18805,60771,21310,114800,82,67,70,135 05479 12/09/2025 05:44:25 Discharge level 021 AH, SOC: 70%, I: 1A, L:3832, l:3860, H:3847, B:015, PT:024C, BT:025C, PV:107612, M:Bike On 05480 12/09/2025 05:44:25 SOC:18794,60801,21631,114800,82,75,70,34 05481 12/09/2025 05:45:25 Discharge level 021 AH, SOC: 70%, I: 1A, L:3837, l:3858, H:3851, B:014, PT:024C, BT:025C, PV:107727, M:Bike On 05482 12/09/2025 05:45:25 SOC:18798,61113,21853,114800,81,75,70,27 05483 12/09/2025 05:46:25 Discharge level 021 AH, SOC: 70%, I: 1A, L:3846, l:3858, H:3861, B:015, PT:024C, BT:025C, PV:107988, M:Bike On 05484 12/09/2025 05:46:26 SOC:18655,61473,21946,114800,81,75,70,15 05485 12/09/2025 05:47:25 Discharge level 022 AH, SOC: 69%, I: 50A, L:3743, l:3810, H:3769, B:026, PT:025C, BT:026C, PV:105312, M:Bike On 05486 12/09/2025 05:47:26 SOC:19545,61393,22955,114800,81,70,69,85 05487 12/09/2025 05:48:26 Discharge level 023 AH, SOC: 67%, I: 97A, L:3673, l:3768, H:3711, B:038, PT:025C, BT:026C, PV:103537, M:Bike On 05488 12/09/2025 05:48:26 SOC:20318,61376,23856,114800,80,65,67,121 05489 12/09/2025 05:49:26 Discharge level 025 AH, SOC: 66%, I: 0A, L:3766, l:3820, H:3784, B:018, PT:025C, BT:025C, PV:105822, M:Bike On 05490 12/09/2025 05:49:26 SOC:21283,61137,25007,114800,79,71,66,70 05491 12/09/2025 05:50:26 Discharge level 025 AH, SOC: 66%, I: 0A, L:3800, l:3821, H:3813, B:013, PT:025C, BT:026C, PV:106670, M:Bike On 05492 12/09/2025 05:50:26 SOC:21150,61464,25110,114800,79,71,66,27 05493 12/09/2025 05:51:26 Discharge level 025 AH, SOC: 66%, I: 1A, L:3806, l:3821, H:3818, B:012, PT:025C, BT:025C, PV:106811, M:Bike On 05494 12/09/2025 05:51:26 SOC:21252,62013,25319,114800,78,71,66,19 05495 12/09/2025 05:52:26 Discharge level 025 AH, SOC: 66%, I:139A, L:3652, l:3743, H:3692, B:040, PT:025C, BT:026C, PV:102973, M:Bike On 05496 12/09/2025 05:52:26 SOC:21420,62384,25642,114800,78,62,66,117 05497 12/09/2025 05:53:26 Discharge level 026 AH, SOC: 66%, I: -8A, L:3799, l:3818, H:3810, B:011, PT:025C, BT:026C, PV:106573, M:Bike On 05498 12/09/2025 05:53:26 SOC:21636,62033,26240,114800,78,71,66,25 05499 12/09/2025 05:54:26 Discharge level 026 AH, SOC: 65%, I: 1A, L:3779, l:3803, H:3791, B:012, PT:026C, BT:025C, PV:106054, M:Bike On 05500 12/09/2025 05:54:26 SOC:21837,61982,26690,114800,77,69,65,31 05501 12/09/2025 05:55:23 Contactor was Opened Pack V: 106508mV, Switched V: 106456mV, Prechg Pct: 100%, Dischg Cur: 1000mA 05502 12/09/2025 05:55:23 System Turned Off 05503 12/09/2025 05:55:24 DEBUG: CAN Link Is Down 05504 12/09/2025 05:55:24 DEBUG: Entered Idle State 05505 12/09/2025 05:55:30 Current Sensor Zeroed old: 2505mV, new: 2506mV, corrfact: 250 05506 12/09/2025 05:55:32 Discharge level 026 AH, SOC: 66%, I: 0A, L:3799, l:3810, H:3809, B:010, PT:026C, BT:027C, PV:106565, M:Idle 05507 12/09/2025 05:55:32 SOC:21794,62539,26748,114800,77,70,66,15 05508 12/09/2025 05:55:53 Voltage Across Contactor: 93682mV (Okay) 05509 12/09/2025 06:55:29 System Turned On 05510 12/09/2025 06:55:29 Rev:45,Build:2023-05-20_045619 958 banka 05511 12/09/2025 06:55:29 Pack:2019_monolith,Numbricks:4 05512 12/09/2025 06:55:29 DEBUG: Entered Running State 05513 12/09/2025 06:55:29 DEBUG: CAN NOT Receiving Syncs 05514 12/09/2025 06:55:29 DEBUG: CAN Link Is Up 05515 12/09/2025 06:55:30 DEBUG: Resetting CAN0 due to error passive mode 05516 12/09/2025 06:55:30 Discharge level 026 AH, SOC: 66%, I: 0A, L:3832, l:3844, H:3840, B:008, PT:024C, BT:027C, PV:107401, M:Bike On 05517 12/09/2025 06:55:30 SOC:21789,62539,26748,114800,77,73,66,15 05518 12/09/2025 06:55:33 DEBUG: CAN Receiving Syncs 05519 12/09/2025 06:55:33 Contactor drive turned on Pack V: 107386mV, Switched V: 93932mV, Duty Cycle: 37% 05520 12/09/2025 06:55:33 Contactor was Closed Pack V: 107386mV, Switched V: 93932mV, Prechg Pct: 87%, Dischg Cur: 636mA 05521 12/09/2025 06:56:30 Discharge level 026 AH, SOC: 66%, I: 1A, L:3831, l:3838, H:3838, B:007, PT:024C, BT:026C, PV:107374, M:Bike On 05522 12/09/2025 06:56:30 SOC:21749,63683,26763,114800,77,73,66,9 05523 12/09/2025 06:57:30 Discharge level 026 AH, SOC: 67%, I: 1A, L:3830, l:3835, H:3838, B:008, PT:024C, BT:027C, PV:107371, M:Bike On 05524 12/09/2025 06:57:30 SOC:21749,64847,26779,114800,77,73,67,7 05525 12/09/2025 06:58:30 Discharge level 026 AH, SOC: 67%, I: 1A, L:3829, l:3833, H:3837, B:008, PT:024C, BT:027C, PV:107342, M:Bike On 05526 12/09/2025 06:58:30 SOC:21752,65906,26798,114800,77,72,67,6 05527 12/09/2025 06:59:30 Discharge level 027 AH, SOC: 67%, I: 73A, L:3745, l:3795, H:3761, B:016, PT:024C, BT:027C, PV:105141, M:Bike On 05528 12/09/2025 06:59:30 SOC:21865,66201,27108,114800,77,68,67,63 05529 12/09/2025 07:00:30 Discharge level 027 AH, SOC: 68%, I: 1A, L:3819, l:3825, H:3826, B:007, PT:024C, BT:027C, PV:107043, M:Bike On 05530 12/09/2025 07:00:30 SOC:21863,66946,27156,114800,77,72,68,8 05531 12/09/2025 07:01:30 Discharge level 027 AH, SOC: 68%, I: 1A, L:3814, l:3821, H:3822, B:008, PT:024C, BT:027C, PV:106921, M:Bike On 05532 12/09/2025 07:01:30 SOC:21991,67481,27328,114800,77,71,68,9 05533 12/09/2025 07:02:30 Discharge level 027 AH, SOC: 68%, I: 1A, L:3800, l:3815, H:3808, B:008, PT:024C, BT:027C, PV:106530, M:Bike On 05534 12/09/2025 07:02:30 SOC:22223,67651,27677,114800,76,71,68,19 05535 12/09/2025 07:03:30 Discharge level 027 AH, SOC: 68%, I: 1A, L:3800, l:3812, H:3807, B:007, PT:024C, BT:027C, PV:106521, M:Bike On 05536 12/09/2025 07:03:30 SOC:22354,67944,27891,114800,76,70,68,15 05537 12/09/2025 07:04:30 Discharge level 028 AH, SOC: 67%, I: 83A, L:3699, l:3757, H:3719, B:020, PT:024C, BT:027C, PV:103890, M:Bike On 05538 12/09/2025 07:04:30 SOC:22594,68222,28168,114800,76,64,67,73 05539 12/09/2025 07:05:30 Discharge level 029 AH, SOC: 66%, I: 70A, L:3718, l:3786, H:3732, B:014, PT:025C, BT:027C, PV:104320, M:Bike On 05540 12/09/2025 07:05:30 SOC:23355,67783,29081,114800,75,67,66,87 05541 12/09/2025 07:06:30 Discharge level 029 AH, SOC: 66%, I: 1A, L:3768, l:3791, H:3775, B:007, PT:025C, BT:028C, PV:105617, M:Bike On 05542 12/09/2025 07:06:30 SOC:23561,67506,29522,114800,75,68,66,29 05543 12/09/2025 07:07:04 Contactor was Opened Pack V: 105846mV, Switched V: 105787mV, Prechg Pct: 100%, Dischg Cur: 1000mA 05544 12/09/2025 07:07:04 System Turned Off 05545 12/09/2025 07:07:05 DEBUG: CAN Link Is Down 05546 12/09/2025 07:07:05 DEBUG: Entered Idle State 05547 12/09/2025 07:07:11 Current Sensor Zeroed old: 2506mV, new: 2504mV, corrfact: 252 05548 12/09/2025 07:07:12 Discharge level 029 AH, SOC: 66%, I: 0A, L:3779, l:3792, H:3785, B:006, PT:025C, BT:027C, PV:105925, M:Idle 05549 12/09/2025 07:07:12 SOC:23574,67796,29540,114800,75,68,66,17 05550 12/09/2025 07:07:34 Voltage Across Contactor: 93201mV (Okay) 05551 12/09/2025 07:11:46 System Turned On 05552 12/09/2025 07:11:46 Rev:45,Build:2023-05-20_045619 958 banka 05553 12/09/2025 07:11:46 Pack:2019_monolith,Numbricks:4 05554 12/09/2025 07:11:46 DEBUG: Entered Running State 05555 12/09/2025 07:11:46 DEBUG: CAN NOT Receiving Syncs 05556 12/09/2025 07:11:46 DEBUG: CAN Link Is Up 05557 12/09/2025 07:11:47 DEBUG: Resetting CAN0 due to error passive mode 05558 12/09/2025 07:11:47 Discharge level 029 AH, SOC: 66%, I: 0A, L:3792, l:3805, H:3798, B:006, PT:025C, BT:027C, PV:106278, M:Bike On 05559 12/09/2025 07:11:47 SOC:23570,67796,29540,114800,75,70,66,17 05560 12/09/2025 07:11:50 DEBUG: CAN Receiving Syncs 05561 12/09/2025 07:11:51 Contactor drive turned on Pack V: 106266mV, Switched V: 93026mV, Duty Cycle: 37% 05562 12/09/2025 07:11:51 Contactor was Closed Pack V: 106266mV, Switched V: 93026mV, Prechg Pct: 88%, Dischg Cur: 909mA 05563 12/09/2025 07:12:15 Contactor was Opened Pack V: 106268mV, Switched V: 106220mV, Prechg Pct: 100%, Dischg Cur: 1182mA 05564 12/09/2025 07:12:16 System Turned Off 05565 12/09/2025 07:12:16 DEBUG: CAN Link Is Down 05566 12/09/2025 07:12:17 DEBUG: Entered Idle State 05567 12/09/2025 07:12:23 Discharge level 029 AH, SOC: 66%, I: 0A, L:3793, l:3802, H:3799, B:006, PT:025C, BT:027C, PV:106307, M:Idle 05568 12/09/2025 07:12:23 SOC:23558,68091,29549,114800,75,69,66,12 05569 12/09/2025 07:12:45 Voltage Across Contactor: 93363mV (Okay) 05570 12/09/2025 07:14:22 System Turned On 05571 12/09/2025 07:14:22 Rev:45,Build:2023-05-20_045619 958 banka 05572 12/09/2025 07:14:22 Pack:2019_monolith,Numbricks:4 05573 12/09/2025 07:14:22 DEBUG: Entered Running State 05574 12/09/2025 07:14:22 DEBUG: CAN NOT Receiving Syncs 05575 12/09/2025 07:14:22 DEBUG: CAN Link Is Up 05576 12/09/2025 07:14:23 DEBUG: Resetting CAN0 due to error passive mode 05577 12/09/2025 07:14:23 Discharge level 029 AH, SOC: 66%, I: 0A, L:3793, l:3803, H:3801, B:008, PT:025C, BT:027C, PV:106326, M:Bike On 05578 12/09/2025 07:14:23 SOC:23555,68091,29549,114800,75,69,66,12 05579 12/09/2025 07:14:26 DEBUG: CAN Receiving Syncs 05580 12/09/2025 07:14:26 Contactor drive turned on Pack V: 106314mV, Switched V: 93184mV, Duty Cycle: 37% 05581 12/09/2025 07:14:26 Contactor was Closed Pack V: 106314mV, Switched V: 93184mV, Prechg Pct: 88%, Dischg Cur: 1091mA 05582 12/09/2025 07:15:23 Discharge level 029 AH, SOC: 66%, I: 1A, L:3793, l:3799, H:3800, B:007, PT:025C, BT:027C, PV:106310, M:Bike On 05583 12/09/2025 07:15:23 SOC:23561,68699,29570,114800,75,69,66,8 05584 12/09/2025 07:15:57 Contactor was Opened Pack V: 106308mV, Switched V: 106259mV, Prechg Pct: 100%, Dischg Cur: 1364mA 05585 12/09/2025 07:15:57 System Turned Off 05586 12/09/2025 07:15:58 DEBUG: CAN Link Is Down 05587 12/09/2025 07:15:58 DEBUG: Entered Idle State 05588 12/09/2025 07:16:05 Discharge level 029 AH, SOC: 66%, I: 0A, L:3794, l:3799, H:3801, B:007, PT:024C, BT:027C, PV:106340, M:Idle 05589 12/09/2025 07:16:05 SOC:23568,69041,29582,114800,75,69,66,6 05590 12/09/2025 07:16:27 Voltage Across Contactor: 93122mV (Okay) 05591 12/09/2025 07:41:12 System Turned On 05592 12/09/2025 07:41:12 Rev:45,Build:2023-05-20_045619 958 banka 05593 12/09/2025 07:41:12 Pack:2019_monolith,Numbricks:4 05594 12/09/2025 07:41:12 DEBUG: Entered Running State 05595 12/09/2025 07:41:12 DEBUG: CAN NOT Receiving Syncs 05596 12/09/2025 07:41:12 DEBUG: CAN Link Is Up 05597 12/09/2025 07:41:13 DEBUG: Resetting CAN0 due to error passive mode 05598 12/09/2025 07:41:13 Discharge level 029 AH, SOC: 66%, I: 0A, L:3798, l:3803, H:3808, B:010, PT:024C, BT:026C, PV:106470, M:Bike On 05599 12/09/2025 07:41:13 SOC:23565,69041,29582,114800,75,69,66,6 05600 12/09/2025 07:41:16 DEBUG: CAN Receiving Syncs 05601 12/09/2025 07:41:16 Contactor drive turned on Pack V: 106451mV, Switched V: 93026mV, Duty Cycle: 37% 05602 12/09/2025 07:41:17 Contactor was Closed Pack V: 106451mV, Switched V: 93026mV, Prechg Pct: 87%, Dischg Cur: 909mA 05603 12/09/2025 07:42:13 Discharge level 029 AH, SOC: 67%, I: 0A, L:3798, l:3802, H:3807, B:009, PT:024C, BT:026C, PV:106453, M:Bike On 05604 12/09/2025 07:42:13 SOC:23483,69353,29594,114800,75,69,67,5 05605 12/09/2025 07:43:13 Discharge level 029 AH, SOC: 67%, I: 82A, L:3697, l:3744, H:3716, B:019, PT:024C, BT:026C, PV:103813, M:Bike On 05606 12/09/2025 07:43:13 SOC:23404,69539,29630,114800,75,63,67,60 05607 12/09/2025 07:44:13 Discharge level 029 AH, SOC: 67%, I: 76A, L:3703, l:3751, H:3722, B:019, PT:024C, BT:027C, PV:103986, M:Bike On 05608 12/09/2025 07:44:13 SOC:23440,69633,29784,114800,75,64,67,61 05609 12/09/2025 07:45:13 Discharge level 030 AH, SOC: 66%, I: 12A, L:3756, l:3782, H:3765, B:009, PT:024C, BT:027C, PV:105318, M:Bike On 05610 12/09/2025 07:45:13 SOC:23842,69484,30276,114800,74,67,66,33 05611 12/09/2025 07:46:13 Discharge level 030 AH, SOC: 66%, I: 52A, L:3708, l:3754, H:3721, B:013, PT:024C, BT:027C, PV:104022, M:Bike On 05612 12/09/2025 07:46:13 SOC:24035,69382,30592,114800,74,64,66,59 05613 12/09/2025 07:47:13 Discharge level 031 AH, SOC: 65%, I: 59A, L:3634, l:3697, H:3656, B:022, PT:024C, BT:027C, PV:102067, M:Bike On 05614 12/09/2025 07:47:13 SOC:24441,69159,31084,114800,73,57,65,80 05615 12/09/2025 07:48:13 Discharge level 031 AH, SOC: 65%, I: 27A, L:3714, l:3745, H:3727, B:013, PT:024C, BT:027C, PV:104191, M:Bike On 05616 12/09/2025 07:48:13 SOC:24471,69216,31224,114800,73,63,65,40 05617 12/09/2025 07:49:13 Discharge level 031 AH, SOC: 65%, I: 32A, L:3718, l:3754, H:3729, B:011, PT:024C, BT:027C, PV:104263, M:Bike On 05618 12/09/2025 07:49:13 SOC:24762,69095,31596,114800,73,64,65,47 05619 12/09/2025 07:50:13 Discharge level 031 AH, SOC: 64%, I:-18A, L:3772, l:3786, H:3778, B:006, PT:024C, BT:027C, PV:105709, M:Bike On 05620 12/09/2025 07:50:13 SOC:25015,68920,31960,114800,73,68,64,18 05621 12/09/2025 07:51:13 Discharge level 032 AH, SOC: 64%, I: 1A, L:3753, l:3768, H:3759, B:006, PT:024C, BT:027C, PV:105174, M:Bike On 05622 12/09/2025 07:51:13 SOC:25088,68885,32154,114800,72,65,64,19 05623 12/09/2025 07:52:13 Discharge level 033 AH, SOC: 62%, I: 1A, L:3714, l:3762, H:3722, B:008, PT:024C, BT:027C, PV:104139, M:Bike On 05624 12/09/2025 07:52:13 SOC:26130,67976,33341,114800,71,65,62,62 05625 12/09/2025 07:53:13 Discharge level 034 AH, SOC: 59%, I: 2A, L:3679, l:3749, H:3691, B:012, PT:025C, BT:027C, PV:103244, M:Bike On 05626 12/09/2025 07:53:13 SOC:27516,67002,34834,114800,70,63,59,91 05627 12/09/2025 07:53:13 Discharge cutback 84% 05628 12/09/2025 07:53:13 722A 05629 12/09/2025 07:54:13 Discharge level 035 AH, SOC: 59%, I: 1A, L:3711, l:3738, H:3720, B:009, PT:025C, BT:027C, PV:104072, M:Bike On 05630 12/09/2025 07:54:13 SOC:27672,67154,35098,114800,70,62,59,36 05631 12/09/2025 07:55:13 Discharge level 035 AH, SOC: 59%, I: 14A, L:3702, l:3727, H:3712, B:010, PT:025C, BT:026C, PV:103818, M:Bike On 05632 12/09/2025 07:55:13 SOC:27708,67330,35257,114800,70,61,59,33 05633 12/09/2025 07:56:13 Discharge level 035 AH, SOC: 58%, I: 17A, L:3688, l:3722, H:3699, B:011, PT:025C, BT:026C, PV:103477, M:Bike On 05634 12/09/2025 07:56:13 SOC:28280,67297,35875,114800,69,60,58,45 05635 12/09/2025 07:57:13 Discharge level 036 AH, SOC: 57%, I: 1A, L:3682, l:3729, H:3692, B:010, PT:025C, BT:026C, PV:103291, M:Bike On 05636 12/09/2025 07:57:13 SOC:29254,66916,36900,114800,68,61,57,62 05637 12/09/2025 07:57:13 Discharge cutback 89% 05638 12/09/2025 07:57:13 763A 05639 12/09/2025 07:58:13 Discharge level 037 AH, SOC: 56%, I:-18A, L:3709, l:3728, H:3716, B:007, PT:025C, BT:027C, PV:103979, M:Bike On 05640 12/09/2025 07:58:13 SOC:29729,66666,37545,114800,68,61,56,26 05641 12/09/2025 07:59:13 Discharge level 037 AH, SOC: 56%, I: 15A, L:3672, l:3707, H:3685, B:013, PT:025C, BT:027C, PV:103065, M:Bike On 05642 12/09/2025 07:59:13 SOC:29959,66774,37896,114800,67,58,56,47 05643 12/09/2025 08:00:13 Discharge level 039 AH, SOC: 54%, I:-26A, L:3683, l:3719, H:3693, B:010, PT:025C, BT:026C, PV:103310, M:Bike On 05644 12/09/2025 08:00:13 SOC:30967,66250,39008,114800,67,60,54,48 05645 12/09/2025 08:00:13 Discharge cutback 82% 05646 12/09/2025 08:00:13 709A 05647 12/09/2025 08:01:13 Discharge level 039 AH, SOC: 54%, I:-26A, L:3708, l:3722, H:3714, B:006, PT:025C, BT:025C, PV:103922, M:Bike On 05648 12/09/2025 08:01:13 SOC:30818,66035,39230,114800,66,60,54,18 05649 12/09/2025 08:02:13 Discharge level 039 AH, SOC: 54%, I: 0A, L:3681, l:3704, H:3691, B:010, PT:025C, BT:025C, PV:103271, M:Bike On 05650 12/09/2025 08:02:13 SOC:30683,65794,39466,114800,66,58,54,31 05651 12/09/2025 08:03:13 Discharge level 039 AH, SOC: 54%, I:184A, L:3480, l:3598, H:3531, B:051, PT:025C, BT:026C, PV: 98344, M:Bike On 05652 12/09/2025 08:03:13 SOC:30711,65477,39831,114800,66,40,54,157 05653 12/09/2025 08:03:13 Discharge cutback 89% 05654 12/09/2025 08:03:13 769A 05655 12/09/2025 08:04:13 Discharge level 040 AH, SOC: 52%, I: 1A, L:3667, l:3693, H:3677, B:010, PT:025C, BT:026C, PV:102885, M:Bike On 05656 12/09/2025 08:04:13 SOC:31527,65191,40731,114800,65,56,52,35 05657 12/09/2025 08:04:13 Discharge cutback 89% 05658 12/09/2025 08:04:13 763A 05659 12/09/2025 08:05:13 Discharge level 041 AH, SOC: 51%, I: 1A, L:3662, l:3688, H:3674, B:012, PT:025C, BT:025C, PV:102780, M:Bike On 05660 12/09/2025 08:05:13 SOC:32066,65435,41297,114800,65,55,51,35 05661 12/09/2025 08:05:13 Discharge cutback 89% 05662 12/09/2025 08:05:13 769A 05663 12/09/2025 08:06:13 Discharge level 041 AH, SOC: 51%, I:126A, L:3516, l:3608, H:3558, B:042, PT:025C, BT:026C, PV: 99201, M:Bike On 05664 12/09/2025 08:06:13 SOC:32382,65729,41681,114800,64,42,51,125 05665 12/09/2025 08:06:13 Discharge cutback 87% 05666 12/09/2025 08:06:13 752A 05667 12/09/2025 08:07:13 Discharge level 042 AH, SOC: 49%, I: 1A, L:3638, l:3682, H:3651, B:013, PT:025C, BT:026C, PV:102140, M:Bike On 05668 12/09/2025 08:07:13 SOC:33472,65436,42800,114800,63,55,49,60 05669 12/09/2025 08:07:13 Discharge cutback 82% 05670 12/09/2025 08:07:13 702A 05671 12/09/2025 08:08:13 Discharge level 043 AH, SOC: 49%, I: 71A, L:3573, l:3638, H:3601, B:028, PT:025C, BT:026C, PV:100596, M:Bike On 05672 12/09/2025 08:08:13 SOC:33950,65530,43391,114800,63,48,49,89 05673 12/09/2025 08:08:13 Discharge cutback 84% 05674 12/09/2025 08:08:13 722A 05675 12/09/2025 08:09:13 Discharge level 044 AH, SOC: 48%, I:-11A, L:3660, l:3675, H:3670, B:010, PT:025C, BT:026C, PV:102698, M:Bike On 05676 12/09/2025 08:09:13 SOC:34340,65137,44080,114800,62,54,48,21 05677 12/09/2025 08:09:13 Discharge cutback 85% 05678 12/09/2025 08:09:13 736A 05679 12/09/2025 08:10:13 Discharge level 044 AH, SOC: 48%, I: 1A, L:3652, l:3671, H:3663, B:011, PT:026C, BT:025C, PV:102500, M:Bike On 05680 12/09/2025 08:10:13 SOC:34282,65235,44314,114800,62,53,48,26 05681 12/09/2025 08:10:13 Discharge cutback 87% 05682 12/09/2025 08:10:13 752A 05683 12/09/2025 08:11:13 Discharge level 044 AH, SOC: 47%, I: 0A, L:3630, l:3661, H:3645, B:015, PT:025C, BT:026C, PV:101974, M:Bike On 05684 12/09/2025 08:11:13 SOC:34656,65374,44831,114800,61,51,47,42 05685 12/09/2025 08:11:13 Discharge cutback 84% 05686 12/09/2025 08:11:13 719A 05687 12/09/2025 08:12:13 Discharge level 044 AH, SOC: 48%, I: 83A, L:3582, l:3634, H:3607, B:025, PT:025C, BT:026C, PV:100785, M:Bike On 05688 12/09/2025 08:12:13 SOC:34370,65485,44879,114800,61,47,48,71 05689 12/09/2025 08:12:13 Discharge cutback 89% 05690 12/09/2025 08:12:13 763A 05691 12/09/2025 08:13:13 Discharge level 044 AH, SOC: 48%, I: 0A, L:3651, l:3665, H:3663, B:012, PT:025C, BT:025C, PV:102483, M:Bike On 05692 12/09/2025 08:13:13 SOC:34161,65626,44967,114800,61,52,48,20 05693 12/09/2025 08:13:13 Discharge cutback 89% 05694 12/09/2025 08:13:13 766A 05695 12/09/2025 08:14:13 Discharge level 045 AH, SOC: 49%, I: 1A, L:3658, l:3668, H:3668, B:010, PT:025C, BT:026C, PV:102640, M:Bike On 05696 12/09/2025 08:14:13 SOC:34187,66081,45116,114800,61,53,49,13 05697 12/09/2025 08:15:13 Discharge level 045 AH, SOC: 48%, I: 91A, L:3538, l:3612, H:3570, B:032, PT:025C, BT:025C, PV: 99664, M:Bike On 05698 12/09/2025 08:15:13 SOC:34573,66065,45625,114800,61,43,48,102 05699 12/09/2025 08:15:13 Discharge cutback 83% 05700 12/09/2025 08:15:13 712A 05701 12/09/2025 08:16:13 Discharge level 046 AH, SOC: 46%, I: 78A, L:3519, l:3616, H:3553, B:034, PT:025C, BT:026C, PV: 99172, M:Bike On 05702 12/09/2025 08:16:13 SOC:35660,65439,46769,114800,60,43,46,134 05703 12/09/2025 08:16:13 Discharge cutback 71% 05704 12/09/2025 08:16:13 611A 05705 12/09/2025 08:17:13 Discharge level 047 AH, SOC: 45%, I:148A, L:3449, l:3563, H:3500, B:051, PT:025C, BT:026C, PV: 97504, M:Bike On 05706 12/09/2025 08:17:13 SOC:36180,65330,47411,114800,59,32,45,158 05707 12/09/2025 08:17:13 Discharge cutback 76% 05708 12/09/2025 08:17:13 651A 05709 12/09/2025 08:18:13 Discharge level 047 AH, SOC: 45%, I: 16A, L:3613, l:3643, H:3629, B:016, PT:026C, BT:026C, PV:101505, M:Bike On 05710 12/09/2025 08:18:13 SOC:36479,65637,47795,114800,59,49,45,42 05711 12/09/2025 08:18:13 Discharge cutback 82% 05712 12/09/2025 08:18:13 705A 05713 12/09/2025 08:19:13 Discharge level 048 AH, SOC: 45%, I: 30A, L:3597, l:3633, H:3616, B:019, PT:025C, BT:026C, PV:101097, M:Bike On 05714 12/09/2025 08:19:13 SOC:36851,66011,48205,114800,59,47,45,50 05715 12/09/2025 08:19:13 Discharge cutback 82% 05716 12/09/2025 08:19:13 705A 05717 12/09/2025 08:20:13 Discharge level 048 AH, SOC: 44%, I: 43A, L:3574, l:3622, H:3597, B:023, PT:026C, BT:026C, PV:100545, M:Bike On 05718 12/09/2025 08:20:13 SOC:37358,66196,48755,114800,58,45,44,67 05719 12/09/2025 08:20:13 Discharge cutback 78% 05720 12/09/2025 08:20:13 675A 05721 12/09/2025 08:21:13 Discharge level 049 AH, SOC: 42%, I: 69A, L:3519, l:3605, H:3552, B:033, PT:026C, BT:025C, PV: 99157, M:Bike On 05722 12/09/2025 08:21:13 SOC:38278,65970,49694,114800,57,41,42,120 05723 12/09/2025 08:21:13 Discharge cutback 70% 05724 12/09/2025 08:21:13 601A 05725 12/09/2025 08:22:13 Discharge level 050 AH, SOC: 41%, I: 1A, L:3595, l:3633, H:3611, B:016, PT:026C, BT:025C, PV:101011, M:Bike On 05726 12/09/2025 08:22:13 SOC:39246,65593,50770,114800,56,47,41,53 05727 12/09/2025 08:22:13 Discharge cutback 73% 05728 12/09/2025 08:22:13 624A 05729 12/09/2025 08:23:13 Discharge level 051 AH, SOC: 41%, I: 0A, L:3605, l:3633, H:3621, B:016, PT:026C, BT:025C, PV:101279, M:Bike On 05730 12/09/2025 08:23:13 SOC:39363,66006,51054,114800,56,47,41,39 05731 12/09/2025 08:23:13 Discharge cutback 77% 05732 12/09/2025 08:23:13 661A 05733 12/09/2025 08:24:13 Discharge level 051 AH, SOC: 41%, I: 1A, L:3605, l:3632, H:3619, B:014, PT:026C, BT:025C, PV:101246, M:Bike On 05734 12/09/2025 08:24:13 SOC:39789,66327,51581,114800,56,47,41,38 05735 12/09/2025 08:24:13 Discharge cutback 76% 05736 12/09/2025 08:24:13 658A 05737 12/09/2025 08:25:13 Discharge level 052 AH, SOC: 39%, I: 1A, L:3585, l:3632, H:3601, B:016, PT:026C, BT:025C, PV:100722, M:Bike On 05738 12/09/2025 08:25:13 SOC:40410,65964,52382,114800,55,47,39,66 05739 12/09/2025 08:25:13 Discharge cutback 63% 05740 12/09/2025 08:25:13 543A 05741 12/09/2025 08:26:13 Discharge level 052 AH, SOC: 39%, I: 1A, L:3597, l:3624, H:3612, B:015, PT:026C, BT:025C, PV:101042, M:Bike On 05742 12/09/2025 08:26:13 SOC:40465,65308,52939,114800,54,45,39,38 05743 12/09/2025 08:26:13 Discharge cutback 75% 05744 12/09/2025 08:26:13 641A 05745 12/09/2025 08:27:13 Discharge level 053 AH, SOC: 39%, I: 27A, L:3577, l:3608, H:3598, B:021, PT:026C, BT:025C, PV:100587, M:Bike On 05746 12/09/2025 08:27:13 SOC:40521,65950,53159,114800,54,42,39,43 05747 12/09/2025 08:27:13 Discharge cutback 79% 05748 12/09/2025 08:27:13 678A 05749 12/09/2025 08:28:13 Discharge level 053 AH, SOC: 39%, I: -3A, L:3613, l:3626, H:3626, B:013, PT:026C, BT:026C, PV:101456, M:Bike On 05750 12/09/2025 08:28:13 SOC:40594,66417,53434,114800,54,46,39,19 05751 12/09/2025 08:28:13 Discharge cutback 80% 05752 12/09/2025 08:28:13 685A 05753 12/09/2025 08:29:13 Discharge level 053 AH, SOC: 40%, I: 2A, L:3612, l:3627, H:3626, B:014, PT:026C, BT:026C, PV:101431, M:Bike On 05754 12/09/2025 08:29:13 SOC:40677,67437,53544,114800,54,46,40,21 05755 12/09/2025 08:29:13 Discharge cutback 81% 05756 12/09/2025 08:29:13 695A 05757 12/09/2025 08:30:13 Discharge level 053 AH, SOC: 41%, I:-14A, L:3627, l:3629, H:3640, B:013, PT:026C, BT:026C, PV:101834, M:Bike On 05758 12/09/2025 08:30:13 SOC:40455,67548,53685,114800,54,46,41,4 05759 12/09/2025 08:30:13 Discharge cutback 82% 05760 12/09/2025 08:30:14 702A 05761 12/09/2025 08:31:13 Discharge level 053 AH, SOC: 41%, I:-16A, L:3638, l:3638, H:3648, B:010, PT:026C, BT:026C, PV:102087, M:Bike On 05762 12/09/2025 08:31:13 SOC:40297,68078,53724,114800,54,48,41,0 05763 12/09/2025 08:31:13 Discharge cutback 82% 05764 12/09/2025 08:31:14 709A 05765 12/09/2025 08:32:13 Discharge level 053 AH, SOC: 42%, I: -2A, L:3626, l:3629, H:3639, B:013, PT:026C, BT:026C, PV:101812, M:Bike On 05766 12/09/2025 08:32:13 SOC:40099,68542,53727,114800,54,46,42,5 05767 12/09/2025 08:32:13 Discharge cutback 84% 05768 12/09/2025 08:32:14 722A 05769 12/09/2025 08:33:13 Discharge level 053 AH, SOC: 43%, I: 1A, L:3624, l:3629, H:3636, B:012, PT:026C, BT:027C, PV:101735, M:Bike On 05770 12/09/2025 08:33:13 SOC:40038,69047,53777,114800,54,46,43,7 05771 12/09/2025 08:33:13 Discharge cutback 84% 05772 12/09/2025 08:33:14 722A 05773 12/09/2025 08:34:13 Discharge level 053 AH, SOC: 43%, I:157A, L:3458, l:3539, H:3503, B:045, PT:026C, BT:026C, PV: 97651, M:Bike On 05774 12/09/2025 08:34:13 SOC:40060,69441,53893,114800,54,25,43,113 05775 12/09/2025 08:34:13 Discharge cutback 82% 05776 12/09/2025 08:34:14 705A 05777 12/09/2025 08:35:13 Discharge level 053 AH, SOC: 43%, I: 1A, L:3622, l:3627, H:3636, B:014, PT:026C, BT:026C, PV:101717, M:Bike On 05778 12/09/2025 08:35:13 SOC:40068,69971,53946,114800,54,46,43,7 05779 12/09/2025 08:35:14 Discharge cutback 84% 05780 12/09/2025 08:35:14 722A 05781 12/09/2025 08:36:13 Discharge level 053 AH, SOC: 44%, I: 5A, L:3619, l:3625, H:3633, B:014, PT:026C, BT:027C, PV:101638, M:Bike On 05782 12/09/2025 08:36:13 SOC:40088,70462,53994,114800,53,46,44,8 05783 12/09/2025 08:36:14 Discharge cutback 84% 05784 12/09/2025 08:36:14 725A 05785 12/09/2025 08:37:13 Discharge level 054 AH, SOC: 44%, I:-14A, L:3635, l:3639, H:3645, B:010, PT:026C, BT:026C, PV:102009, M:Bike On 05786 12/09/2025 08:37:13 SOC:40179,70693,54144,114800,53,48,44,6 05787 12/09/2025 08:37:14 Discharge cutback 81% 05788 12/09/2025 08:37:14 695A 05789 12/09/2025 08:38:13 Discharge level 054 AH, SOC: 44%, I: 5A, L:3614, l:3624, H:3628, B:014, PT:026C, BT:026C, PV:101501, M:Bike On 05790 12/09/2025 08:38:14 SOC:40261,70787,54333,114800,53,45,44,14 05791 12/09/2025 08:38:14 Discharge cutback 82% 05792 12/09/2025 08:38:14 705A 05793 12/09/2025 08:39:13 Discharge level 054 AH, SOC: 44%, I: 0A, L:3619, l:3626, H:3632, B:013, PT:026C, BT:027C, PV:101613, M:Bike On 05794 12/09/2025 08:39:14 SOC:40332,71002,54473,114800,53,46,44,11 05795 12/09/2025 08:39:14 Discharge cutback 82% 05796 12/09/2025 08:39:14 709A 05797 12/09/2025 08:40:13 Discharge level 054 AH, SOC: 44%, I: 1A, L:3619, l:3626, H:3631, B:012, PT:025C, BT:027C, PV:101598, M:Bike On 05798 12/09/2025 08:40:14 SOC:40402,71187,54617,114800,53,46,44,10 05799 12/09/2025 08:40:14 Discharge cutback 82% 05800 12/09/2025 08:40:14 709A 05801 12/09/2025 08:40:55 Contactor was Opened Pack V: 101669mV, Switched V: 101651mV, Prechg Pct: 100%, Dischg Cur: 1546mA 05802 12/09/2025 08:40:55 System Turned Off 05803 12/09/2025 08:40:56 DEBUG: CAN Link Is Down 05804 12/09/2025 08:40:56 DEBUG: Entered Idle State 05805 12/09/2025 08:41:02 Current Sensor Zeroed old: 2504mV, new: 2506mV, corrfact: 250 05806 12/09/2025 08:41:03 Discharge level 054 AH, SOC: 44%, I: 0A, L:3622, l:3626, H:3635, B:013, PT:025C, BT:027C, PV:101703, M:Idle 05807 12/09/2025 08:41:03 SOC:40414,71537,54633,114800,53,46,44,5 05808 12/09/2025 08:41:25 Voltage Across Contactor: 87910mV (Okay) 05809 12/09/2025 09:34:51 System Turned On 05810 12/09/2025 09:34:51 Rev:45,Build:2023-05-20_045619 958 banka 05811 12/09/2025 09:34:51 Pack:2019_monolith,Numbricks:4 05812 12/09/2025 09:34:51 DEBUG: Entered Running State 05813 12/09/2025 09:34:51 DEBUG: CAN NOT Receiving Syncs 05814 12/09/2025 09:34:52 DEBUG: CAN Link Is Up 05815 12/09/2025 09:34:52 DEBUG: Resetting CAN0 due to error passive mode 05816 12/09/2025 09:34:53 Discharge level 054 AH, SOC: 44%, I: 0A, L:3635, l:3639, H:3646, B:011, PT:024C, BT:026C, PV:102025, M:Bike On 05817 12/09/2025 09:34:53 SOC:40410,71537,54633,114800,53,48,44,5 05818 12/09/2025 09:34:53 Discharge cutback 87% 05819 12/09/2025 09:34:53 746A 05820 12/09/2025 09:34:56 DEBUG: CAN Receiving Syncs 05821 12/09/2025 09:35:01 Contactor drive turned on Pack V: 102016mV, Switched V: 90190mV, Duty Cycle: 39% 05822 12/09/2025 09:35:01 Contactor was Closed Pack V: 102016mV, Switched V: 90190mV, Prechg Pct: 88%, Dischg Cur: 454mA 05823 12/09/2025 09:35:53 Discharge level 054 AH, SOC: 44%, I: 0A, L:3636, l:3639, H:3646, B:010, PT:024C, BT:025C, PV:102012, M:Bike On 05824 12/09/2025 09:35:53 SOC:40167,71698,54636,114800,53,48,44,4 05825 12/09/2025 09:35:53 Discharge cutback 87% 05826 12/09/2025 09:35:53 746A 05827 12/09/2025 09:36:53 Discharge level 054 AH, SOC: 45%, I: 0A, L:3634, l:3638, H:3644, B:010, PT:024C, BT:026C, PV:101974, M:Bike On 05828 12/09/2025 09:36:53 SOC:40045,71972,54672,114800,53,48,45,6 05829 12/09/2025 09:36:53 Discharge cutback 85% 05830 12/09/2025 09:36:53 736A 05831 12/09/2025 09:37:53 Discharge level 054 AH, SOC: 45%, I: 1A, L:3632, l:3637, H:3642, B:010, PT:024C, BT:025C, PV:101918, M:Bike On 05832 12/09/2025 09:37:53 SOC:40108,72366,54776,114800,53,48,45,7 05833 12/09/2025 09:37:53 Discharge cutback 85% 05834 12/09/2025 09:37:53 732A 05835 12/09/2025 09:38:53 Discharge level 054 AH, SOC: 45%, I: 0A, L:3629, l:3634, H:3640, B:011, PT:024C, BT:025C, PV:101852, M:Bike On 05836 12/09/2025 09:38:53 SOC:40093,72376,54913,114800,53,47,45,7 05837 12/09/2025 09:38:53 Discharge cutback 84% 05838 12/09/2025 09:38:53 722A 05839 12/09/2025 09:39:53 Discharge level 055 AH, SOC: 45%, I: 60A, L:3549, l:3592, H:3573, B:024, PT:024C, BT:026C, PV: 99815, M:Bike On 05840 12/09/2025 09:39:53 SOC:40327,72210,55240,114800,52,39,45,57 05841 12/09/2025 09:39:53 Discharge cutback 81% 05842 12/09/2025 09:39:53 695A 05843 12/09/2025 09:40:53 Discharge level 055 AH, SOC: 44%, I: 68A, L:3525, l:3587, H:3551, B:026, PT:024C, BT:026C, PV: 99179, M:Bike On 05844 12/09/2025 09:40:53 SOC:40882,71756,55829,114800,52,38,44,84 05845 12/09/2025 09:40:53 Discharge cutback 75% 05846 12/09/2025 09:40:53 641A 05847 12/09/2025 09:41:53 Discharge level 057 AH, SOC: 41%, I:-33A, L:3617, l:3639, H:3628, B:011, PT:024C, BT:026C, PV:101513, M:Bike On 05848 12/09/2025 09:41:53 SOC:42080,70393,57070,114800,51,48,41,30 05849 12/09/2025 09:41:53 Discharge cutback 64% 05850 12/09/2025 09:41:53 553A 05851 12/09/2025 09:42:53 Discharge level 057 AH, SOC: 40%, I:-33A, L:3607, l:3630, H:3619, B:012, PT:024C, BT:026C, PV:101248, M:Bike On 05852 12/09/2025 09:42:53 SOC:42511,69779,57642,114800,50,46,40,31 05853 12/09/2025 09:42:53 Discharge cutback 68% 05854 12/09/2025 09:42:53 587A 05855 12/09/2025 09:43:53 Discharge level 058 AH, SOC: 38%, I: 2A, L:3572, l:3609, H:3587, B:015, PT:024C, BT:025C, PV:100340, M:Bike On 05856 12/09/2025 09:43:53 SOC:42997,68936,58347,114800,50,42,38,51 05857 12/09/2025 09:43:53 Discharge cutback 66% 05858 12/09/2025 09:43:53 570A 05859 12/09/2025 09:44:53 Discharge level 060 AH, SOC: 32%, I: 3A, L:3514, l:3598, H:3536, B:022, PT:025C, BT:026C, PV: 98843, M:Bike On 05860 12/09/2025 09:44:53 SOC:45375,66239,60737,114800,48,40,32,117 05861 12/09/2025 09:44:53 Discharge cutback 44% 05862 12/09/2025 09:44:53 381A 05863 12/09/2025 09:45:53 Discharge level 063 AH, SOC: 25%, I:116A, L:3362, l:3521, H:3410, B:048, PT:025C, BT:025C, PV: 95012, M:Bike On 05864 12/09/2025 09:45:53 SOC:47979,63842,63353,114800,45,18,25,210 05865 12/09/2025 09:45:53 Discharge cutback 42% 05866 12/09/2025 09:45:53 364A 05867 12/09/2025 09:46:53 Discharge level 063 AH, SOC: 26%, I: 94A, L:3449, l:3542, H:3484, B:035, PT:026C, BT:026C, PV: 97242, M:Bike On 05868 12/09/2025 09:46:53 SOC:47877,64578,63641,114800,45,27,26,129 05869 12/09/2025 09:46:53 Discharge cutback 62% 05870 12/09/2025 09:46:53 533A 05871 12/09/2025 09:47:53 Discharge level 064 AH, SOC: 26%, I: 1A, L:3526, l:3576, H:3547, B:021, PT:026C, BT:026C, PV: 99179, M:Bike On 05872 12/09/2025 09:47:53 SOC:48266,64376,64497,114800,44,35,26,70 05873 12/09/2025 09:47:53 Discharge cutback 62% 05874 12/09/2025 09:47:53 530A 05875 12/09/2025 09:48:53 Discharge level 065 AH, SOC: 26%, I: 39A, L:3501, l:3561, H:3526, B:025, PT:026C, BT:025C, PV: 98534, M:Bike On 05876 12/09/2025 09:48:53 SOC:48810,65493,65054,114800,44,31,26,83 05877 12/09/2025 09:48:53 Discharge cutback 64% 05878 12/09/2025 09:48:53 550A 05879 12/09/2025 09:49:53 Discharge level 065 AH, SOC: 27%, I:102A, L:3442, l:3521, H:3482, B:040, PT:026C, BT:025C, PV: 97151, M:Bike On 05880 12/09/2025 09:49:53 SOC:48863,66381,65336,114800,44,19,27,111 05881 12/09/2025 09:49:53 Discharge cutback 67% 05882 12/09/2025 09:49:53 574A 05883 12/09/2025 09:50:53 Discharge level 065 AH, SOC: 27%, I: 36A, L:3511, l:3557, H:3536, B:025, PT:026C, BT:026C, PV: 98833, M:Bike On 05884 12/09/2025 09:50:53 SOC:49036,66839,65766,114800,43,31,27,64 05885 12/09/2025 09:50:53 Discharge cutback 67% 05886 12/09/2025 09:50:53 577A 05887 12/09/2025 09:51:53 Discharge level 065 AH, SOC: 29%, I: 0A, L:3563, l:3580, H:3579, B:016, PT:026C, BT:026C, PV:100133, M:Bike On 05888 12/09/2025 09:51:53 SOC:48899,68015,65785,114800,43,36,29,24 05889 12/09/2025 09:51:53 Discharge cutback 71% 05890 12/09/2025 09:51:53 614A 05891 12/09/2025 09:52:32 Contactor was Opened Pack V: 100236mV, Switched V: 100194mV, Prechg Pct: 100%, Dischg Cur: 1182mA 05892 12/09/2025 09:52:33 System Turned Off 05893 12/09/2025 09:52:34 DEBUG: CAN Link Is Down 05894 12/09/2025 09:52:34 DEBUG: Entered Idle State 05895 12/09/2025 09:52:40 Current Sensor Zeroed old: 2506mV, new: 2504mV, corrfact: 252 05896 12/09/2025 09:52:41 Discharge level 065 AH, SOC: 30%, I: 0A, L:3569, l:3582, H:3585, B:016, PT:026C, BT:025C, PV:100283, M:Idle 05897 12/09/2025 09:52:41 SOC:48842,68841,65800,114800,43,37,30,19 05898 12/09/2025 09:53:02 Voltage Across Contactor: 87299mV (Okay) 05899 12/09/2025 09:53:47 System Turned On 05900 12/09/2025 09:53:47 Rev:45,Build:2023-05-20_045619 958 banka 05901 12/09/2025 09:53:47 Pack:2019_monolith,Numbricks:4 05902 12/09/2025 09:53:47 DEBUG: Entered Running State 05903 12/09/2025 09:53:47 DEBUG: CAN NOT Receiving Syncs 05904 12/09/2025 09:53:47 DEBUG: CAN Link Is Up 05905 12/09/2025 09:53:48 DEBUG: Resetting CAN0 due to error passive mode 05906 12/09/2025 09:53:48 Discharge level 065 AH, SOC: 30%, I: 0A, L:3573, l:3586, H:3589, B:016, PT:026C, BT:026C, PV:100403, M:Bike On 05907 12/09/2025 09:53:48 SOC:48835,68841,65800,114800,43,38,30,19 05908 12/09/2025 09:53:48 Discharge cutback 74% 05909 12/09/2025 09:53:48 638A 05910 12/09/2025 09:53:51 DEBUG: CAN Receiving Syncs 05911 12/09/2025 09:53:51 Contactor drive turned on Pack V: 100395mV, Switched V: 88221mV, Duty Cycle: 40% 05912 12/09/2025 09:53:51 Contactor was Closed Pack V: 100395mV, Switched V: 88221mV, Prechg Pct: 88%, Dischg Cur: 545mA 05913 12/09/2025 09:53:53 DEBUG: Entered Charging State 05914 12/09/2025 09:53:53 DEBUG: CAN NOT Receiving Syncs 05915 12/09/2025 09:53:54 Discharge level 065 AH, SOC: 30%, I: 1A, L:3573, l:3586, H:3589, B:016, PT:026C, BT:026C, PV:100403, M:Charge 05916 12/09/2025 09:53:54 SOC:48787,68854,65800,114800,43,38,30,19 05917 12/09/2025 09:53:55 DEBUG: CAN Receiving Syncs 05918 12/09/2025 10:03:54 Discharge level 063 AH, SOC: 38%, I:-12A, L:3626, l:3612, H:3639, B:013, PT:026C, BT:026C, PV:101784, M:Charge 05919 12/09/2025 10:03:54 SOC:36520,58727,63736,114800,45,43,38,-21 05920 12/09/2025 10:13:54 Discharge level 061 AH, SOC: 45%, I:-12A, L:3641, l:3625, H:3652, B:011, PT:026C, BT:027C, PV:102187, M:Charge 05921 12/09/2025 10:13:54 SOC:30364,54665,61658,114800,47,46,45,-23 05922 12/09/2025 10:23:54 Discharge level 059 AH, SOC: 49%, I:-12A, L:3653, l:3637, H:3663, B:010, PT:026C, BT:028C, PV:102504, M:Charge 05923 12/09/2025 10:23:54 SOC:28055,54425,59604,114800,49,48,49,-23 05924 12/09/2025 10:33:54 Discharge level 057 AH, SOC: 52%, I:-12A, L:3664, l:3648, H:3672, B:008, PT:026C, BT:028C, PV:102762, M:Charge 05925 12/09/2025 10:33:54 SOC:27225,55648,57567,114800,50,50,52,-23 05926 12/09/2025 10:43:54 Discharge level 055 AH, SOC: 53%, I:-12A, L:3674, l:3658, H:3681, B:007, PT:026C, BT:028C, PV:103019, M:Charge 05927 12/09/2025 10:43:54 SOC:27149,57609,55547,114800,52,51,53,-23 05928 12/09/2025 10:53:54 Discharge level 053 AH, SOC: 55%, I:-11A, L:3684, l:3668, H:3690, B:006, PT:026C, BT:029C, PV:103260, M:Charge 05929 12/09/2025 10:53:54 SOC:27137,59599,53561,114800,54,53,55,-22 05930 12/09/2025 11:04:01 Discharge level 051 AH, SOC: 56%, I:-11A, L:3696, l:3680, H:3701, B:005, PT:026C, BT:029C, PV:103538, M:Charge 05931 12/09/2025 11:04:01 SOC:27311,61759,51592,114800,56,55,56,-22 05932 12/09/2025 11:14:01 Discharge level 049 AH, SOC: 58%, I:-11A, L:3706, l:3690, H:3710, B:004, PT:026C, BT:034C, PV:103838, M:Charge 05933 12/09/2025 11:14:01 SOC:27245,63654,49645,114800,57,56,58,-22 05934 12/09/2025 11:24:01 Discharge level 047 AH, SOC: 59%, I:-12A, L:3717, l:3701, H:3722, B:005, PT:026C, BT:037C, PV:104163, M:Charge 05935 12/09/2025 11:24:01 SOC:27195,65565,47699,114800,59,57,59,-22 05936 12/09/2025 11:34:01 Discharge level 045 AH, SOC: 61%, I:-11A, L:3729, l:3713, H:3735, B:006, PT:026C, BT:040C, PV:104509, M:Charge 05937 12/09/2025 11:34:01 SOC:26827,67145,45768,114800,61,59,61,-21 05938 12/09/2025 11:44:01 Discharge level 043 AH, SOC: 62%, I:-11A, L:3742, l:3726, H:3748, B:006, PT:026C, BT:040C, PV:104878, M:Charge 05939 12/09/2025 11:44:01 SOC:26329,68592,43838,114800,62,61,62,-21 05940 12/09/2025 11:54:01 Discharge level 041 AH, SOC: 64%, I:-11A, L:3757, l:3741, H:3764, B:007, PT:026C, BT:039C, PV:105301, M:Charge 05941 12/09/2025 11:54:01 SOC:25714,69939,41892,114800,64,63,64,-21 05942 12/09/2025 12:04:01 Discharge level 039 AH, SOC: 65%, I:-11A, L:3772, l:3756, H:3781, B:009, PT:026C, BT:039C, PV:105742, M:Charge 05943 12/09/2025 12:04:01 SOC:24884,71086,39930,114800,66,64,65,-22 05944 12/09/2025 12:14:09 Discharge level 037 AH, SOC: 67%, I:-11A, L:3790, l:3774, H:3799, B:009, PT:026C, BT:040C, PV:106226, M:Charge 05945 12/09/2025 12:14:09 SOC:23915,72114,37949,114800,67,66,67,-22 05946 12/09/2025 12:24:09 Discharge level 035 AH, SOC: 69%, I:-12A, L:3808, l:3791, H:3818, B:010, PT:026C, BT:041C, PV:106734, M:Charge 05947 12/09/2025 12:24:09 SOC:22856,73019,35999,114800,69,68,69,-22 05948 12/09/2025 12:34:09 Discharge level 034 AH, SOC: 71%, I:-11A, L:3828, l:3811, H:3839, B:011, PT:027C, BT:040C, PV:107297, M:Charge 05949 12/09/2025 12:34:09 SOC:21604,73732,34051,114800,71,70,71,-22 05950 12/09/2025 12:44:09 Discharge level 032 AH, SOC: 73%, I:-11A, L:3849, l:3833, H:3859, B:010, PT:027C, BT:039C, PV:107866, M:Charge 05951 12/09/2025 12:44:09 SOC:20293,74373,32114,114800,73,72,73,-22 05952 12/09/2025 12:54:09 Discharge level 030 AH, SOC: 76%, I:-11A, L:3871, l:3855, H:3880, B:009, PT:027C, BT:039C, PV:108478, M:Charge 05953 12/09/2025 12:54:09 SOC:18631,74635,30206,114800,74,75,76,-21 05954 12/09/2025 13:04:09 Discharge level 028 AH, SOC: 78%, I:-11A, L:3894, l:3878, H:3899, B:005, PT:027C, BT:040C, PV:109092, M:Charge 05955 12/09/2025 13:04:09 SOC:17128,75005,28349,114800,76,77,78,-21 05956 12/09/2025 13:14:09 Discharge level 026 AH, SOC: 80%, I:-11A, L:3915, l:3899, H:3919, B:004, PT:027C, BT:043C, PV:109683, M:Charge 05957 12/09/2025 13:14:09 SOC:15591,75352,26484,114800,77,79,80,-21 05958 12/09/2025 13:24:17 Discharge level 024 AH, SOC: 82%, I:-11A, L:3935, l:3920, H:3940, B:005, PT:027C, BT:041C, PV:110266, M:Charge 05959 12/09/2025 13:24:17 SOC:14222,75897,24586,114800,79,81,82,-21 05960 12/09/2025 13:34:17 Discharge level 022 AH, SOC: 83%, I:-11A, L:3955, l:3940, H:3958, B:003, PT:027C, BT:042C, PV:110795, M:Charge 05961 12/09/2025 13:34:17 SOC:13024,76550,22754,114800,81,83,83,-21 05962 12/09/2025 13:44:17 Discharge level 020 AH, SOC: 85%, I:-10A, L:3973, l:3958, H:3976, B:003, PT:027C, BT:041C, PV:111300, M:Charge 05963 12/09/2025 13:44:18 SOC:11863,77233,20927,114800,82,84,85,-20 05964 12/09/2025 13:54:17 Discharge level 019 AH, SOC: 87%, I:-11A, L:3993, l:3978, H:3995, B:002, PT:026C, BT:040C, PV:111836, M:Charge 05965 12/09/2025 13:54:18 SOC:10536,77745,19106,114800,84,86,87,-20 05966 12/09/2025 14:04:17 Discharge level 017 AH, SOC: 89%, I:-10A, L:4010, l:3996, H:4013, B:003, PT:026C, BT:037C, PV:112337, M:Charge 05967 12/09/2025 14:04:18 SOC:9390,78414,17308,114800,85,88,89,-20 05968 12/09/2025 14:12:01 Charged To Full 015 AH, SOC: 90%, L:4025, H:4028, B:003, PT:026C, BT:033C, PV:112738 05969 12/09/2025 14:12:01 SOC adjusted for voltage old: 8332886uAH (soc:90%), new: 7875128uAH (soc:90%), low cell: 4025 mV 05970 12/09/2025 14:14:18 Discharge level 011 AH, SOC: 91%, I:-10A, L:4029, l:4015, H:4031, B:002, PT:026C, BT:033C, PV:112849, M:Charge 05971 12/09/2025 14:14:18 SOC:7774,79062,11071,114800,91,90,91,-20 05972 12/09/2025 14:24:18 Discharge level 009 AH, SOC: 92%, I:-10A, L:4048, l:4034, H:4050, B:002, PT:026C, BT:031C, PV:113370, M:Charge 05973 12/09/2025 14:24:18 SOC:6750,79818,9310,114800,92,91,92,-19 05974 12/09/2025 14:34:26 Discharge level 007 AH, SOC: 94%, I:-10A, L:4067, l:4053, H:4070, B:003, PT:026C, BT:031C, PV:113916, M:Charge 05975 12/09/2025 14:34:26 SOC:5290,80192,7493,114800,94,93,94,-20 05976 12/09/2025 14:44:26 Discharge level 005 AH, SOC: 96%, I:-10A, L:4087, l:4073, H:4089, B:002, PT:026C, BT:031C, PV:114463, M:Charge 05977 12/09/2025 14:44:26 SOC:3899,80603,5708,114800,96,95,96,-20 05978 12/09/2025 15:33:06 DEBUG: CAN Link Is Down 05979 12/09/2025 15:33:11 Contactor was Opened Pack V: 116180mV, Switched V: 116066mV, Prechg Pct: 100%, Dischg Cur: 545mA 05980 12/09/2025 15:33:11 DEBUG: CAN Link Is Up 05981 12/09/2025 15:33:13 System Turned Off 05982 12/09/2025 15:33:14 DEBUG: CAN Link Is Down 05983 12/09/2025 15:33:14 DEBUG: Entered Idle State 05984 12/09/2025 15:33:21 Discharge level 000 AH, SOC:100%, I: 0A, L:4147, l:4145, H:4150, B:003, PT:025C, BT:034C, PV:116164, M:Idle 05985 12/09/2025 15:33:21 SOC:0,81406,0,114800,100,100,100,-4 05986 12/09/2025 15:33:41 Voltage Across Contactor: 103252mV (Okay) 05987 12/10/2025 02:39:32 System Turned On 05988 12/10/2025 02:39:32 Rev:45,Build:2023-05-20_045619 958 banka 05989 12/10/2025 02:39:32 Pack:2019_monolith,Numbricks:4 05990 12/10/2025 02:39:32 DEBUG: Entered Charging State 05991 12/10/2025 02:39:32 DEBUG: CAN NOT Receiving Syncs 05992 12/10/2025 02:39:32 DEBUG: Entered Running State 05993 12/10/2025 02:39:32 DEBUG: CAN Link Is Up 05994 12/10/2025 02:39:33 DEBUG: Resetting CAN0 due to error passive mode 05995 12/10/2025 02:39:33 Discharge level 000 AH, SOC:100%, I: 0A, L:4118, l:4114, H:4122, B:004, PT:017C, BT:022C, PV:115375, M:Bike On 05996 12/10/2025 02:39:33 SOC:1,81406,0,114800,100,99,100,-3 05997 12/10/2025 02:39:36 DEBUG: CAN Receiving Syncs 05998 12/10/2025 02:39:36 Contactor drive turned on Pack V: 115345mV, Switched V: 100982mV, Duty Cycle: 34% 05999 12/10/2025 02:39:36 Contactor was Closed Pack V: 115345mV, Switched V: 100982mV, Prechg Pct: 88%, Dischg Cur: 363mA 06000 12/10/2025 02:40:33 Discharge level 000 AH, SOC:100%, I: 0A, L:4117, l:4117, H:4121, B:004, PT:017C, BT:022C, PV:115345, M:Bike On 06001 12/10/2025 02:40:33 SOC:76,81405,0,114800,100,99,100,0 06002 12/10/2025 02:41:33 Discharge level 000 AH, SOC:100%, I: 1A, L:4110, l:4115, H:4115, B:005, PT:017C, BT:022C, PV:115176, M:Bike On 06003 12/10/2025 02:41:33 SOC:183,81245,56,114800,100,99,100,5 06004 12/10/2025 02:42:33 Discharge level 000 AH, SOC:100%, I: 1A, L:4069, l:4091, H:4081, B:012, PT:017C, BT:022C, PV:114134, M:Bike On 06005 12/10/2025 02:42:33 SOC:522,80422,390,114800,100,97,100,21 06006 12/10/2025 02:43:33 Discharge level 000 AH, SOC:100%, I: 1A, L:4098, l:4110, H:4104, B:006, PT:017C, BT:022C, PV:114865, M:Bike On 06007 12/10/2025 02:43:33 SOC:792,79717,656,114800,100,98,100,11 06008 12/10/2025 02:44:33 Discharge level 000 AH, SOC: 99%, I: 1A, L:4090, l:4097, H:4097, B:007, PT:017C, BT:022C, PV:114631, M:Bike On 06009 12/10/2025 02:44:33 SOC:802,79299,710,114800,100,97,99,6 06010 12/10/2025 02:45:33 Discharge level 000 AH, SOC: 99%, I: 13A, L:4044, l:4064, H:4059, B:015, PT:017C, BT:022C, PV:113451, M:Bike On 06011 12/10/2025 02:45:33 SOC:869,78846,807,114800,100,94,99,20 06012 12/10/2025 02:46:33 Discharge level 001 AH, SOC: 98%, I: 2A, L:3969, l:4054, H:3992, B:023, PT:017C, BT:022C, PV:111512, M:Bike On 06013 12/10/2025 02:46:33 SOC:1873,77365,1801,114800,99,93,98,82 06014 12/10/2025 02:47:33 Discharge level 002 AH, SOC: 98%, I: 9A, L:4039, l:4070, H:4051, B:012, PT:018C, BT:022C, PV:113281, M:Bike On 06015 12/10/2025 02:47:33 SOC:2124,76518,2116,114800,99,95,98,32 06016 12/10/2025 02:48:33 Discharge level 002 AH, SOC: 97%, I: 8A, L:4048, l:4072, H:4059, B:011, PT:018C, BT:023C, PV:113540, M:Bike On 06017 12/10/2025 02:48:33 SOC:2354,75901,2327,114800,98,95,97,24 06018 12/10/2025 02:49:33 Discharge level 002 AH, SOC: 97%, I: 28A, L:4002, l:4037, H:4019, B:017, PT:018C, BT:022C, PV:112318, M:Bike On 06019 12/10/2025 02:49:33 SOC:2585,75321,2535,114800,98,92,97,36 06020 12/10/2025 02:50:33 Discharge level 002 AH, SOC: 97%, I: 1A, L:4055, l:4073, H:4065, B:010, PT:018C, BT:023C, PV:113711, M:Bike On 06021 12/10/2025 02:50:33 SOC:2824,74732,2757,114800,98,95,97,18 06022 12/10/2025 02:51:33 Discharge level 003 AH, SOC: 96%, I: 1A, L:4051, l:4096, H:4060, B:009, PT:018C, BT:022C, PV:113611, M:Bike On 06023 12/10/2025 02:51:33 SOC:3419,73675,3367,114800,98,97,96,46 06024 12/10/2025 02:52:33 Discharge level 003 AH, SOC: 96%, I: 1A, L:4045, l:4061, H:4056, B:011, PT:018C, BT:023C, PV:113447, M:Bike On 06025 12/10/2025 02:52:33 SOC:3595,73208,3567,114800,97,94,96,17 06026 12/10/2025 02:53:33 Discharge level 003 AH, SOC: 95%, I: 0A, L:4054, l:4063, H:4063, B:009, PT:018C, BT:023C, PV:113669, M:Bike On 06027 12/10/2025 02:53:33 SOC:3658,73126,3580,114800,97,94,95,9 06028 12/10/2025 02:54:33 Discharge level 003 AH, SOC: 95%, I: 0A, L:4058, l:4064, H:4067, B:009, PT:018C, BT:023C, PV:113781, M:Bike On 06029 12/10/2025 02:54:33 SOC:3722,73109,3582,114800,97,94,95,6 06030 12/10/2025 02:55:33 Discharge level 003 AH, SOC: 95%, I: 28A, L:3989, l:4017, H:4008, B:019, PT:018C, BT:023C, PV:112000, M:Bike On 06031 12/10/2025 02:55:33 SOC:3850,72922,3673,114800,97,90,95,29 06032 12/10/2025 02:56:33 Discharge level 003 AH, SOC: 95%, I: 1A, L:4056, l:4064, H:4064, B:008, PT:018C, BT:024C, PV:113727, M:Bike On 06033 12/10/2025 02:56:33 SOC:4058,72474,3903,114800,97,94,95,8 06034 12/10/2025 02:57:33 Discharge level 003 AH, SOC: 95%, I: -1A, L:4065, l:4068, H:4072, B:007, PT:018C, BT:024C, PV:113948, M:Bike On 06035 12/10/2025 02:57:33 SOC:4040,72346,3903,114800,97,94,95,3 06036 12/10/2025 02:58:33 Discharge level 003 AH, SOC: 95%, I: -2A, L:4064, l:4067, H:4072, B:008, PT:018C, BT:023C, PV:113937, M:Bike On 06037 12/10/2025 02:58:33 SOC:4102,72198,3958,114800,97,94,95,3 06038 12/10/2025 02:59:33 Discharge level 004 AH, SOC: 95%, I: 1A, L:4055, l:4059, H:4064, B:009, PT:018C, BT:024C, PV:113710, M:Bike On 06039 12/10/2025 02:59:33 SOC:4158,72101,4001,114800,97,94,95,5 06040 12/10/2025 03:00:33 Discharge level 004 AH, SOC: 95%, I: 1A, L:4055, l:4059, H:4064, B:009, PT:018C, BT:024C, PV:113704, M:Bike On 06041 12/10/2025 03:00:33 SOC:4219,71920,4077,114800,97,94,95,4 06042 12/10/2025 03:01:33 Discharge level 004 AH, SOC: 95%, I: -4A, L:4068, l:4069, H:4076, B:008, PT:018C, BT:023C, PV:114069, M:Bike On 06043 12/10/2025 03:01:33 SOC:4276,71762,4149,114800,97,95,95,1 06044 12/10/2025 03:02:33 Discharge level 004 AH, SOC: 94%, I:-15A, L:4069, l:4075, H:4076, B:007, PT:018C, BT:024C, PV:114059, M:Bike On 06045 12/10/2025 03:02:33 SOC:4486,71248,4409,114800,97,95,94,6 06046 12/10/2025 03:03:33 Discharge level 005 AH, SOC: 93%, I: 1A, L:3986, l:4043, H:4003, B:017, PT:019C, BT:024C, PV:111889, M:Bike On 06047 12/10/2025 03:03:33 SOC:5096,70451,5050,114800,96,92,93,58 06048 12/10/2025 03:04:33 Discharge level 005 AH, SOC: 92%, I: 1A, L:3995, l:4032, H:4008, B:013, PT:019C, BT:024C, PV:112097, M:Bike On 06049 12/10/2025 03:04:33 SOC:5811,69277,5883,114800,95,91,92,39 06050 12/10/2025 03:05:33 Discharge level 006 AH, SOC: 91%, I:-27A, L:4025, l:4066, H:4033, B:008, PT:020C, BT:023C, PV:112855, M:Bike On 06051 12/10/2025 03:05:33 SOC:6712,68235,6813,114800,95,94,91,44 06052 12/10/2025 03:06:33 Discharge level 007 AH, SOC: 90%, I: 1A, L:3948, l:3985, H:3969, B:021, PT:020C, BT:022C, PV:110897, M:Bike On 06053 12/10/2025 03:06:33 SOC:7017,67695,7188,114800,94,87,90,40 06054 12/10/2025 03:07:33 Discharge level 007 AH, SOC: 90%, I: -8A, L:4013, l:4028, H:4023, B:010, PT:020C, BT:024C, PV:112559, M:Bike On 06055 12/10/2025 03:07:33 SOC:7152,67500,7344,114800,94,91,90,17 06056 12/10/2025 03:08:33 Discharge level 007 AH, SOC: 89%, I: 47A, L:3919, l:3978, H:3941, B:022, PT:020C, BT:024C, PV:110095, M:Bike On 06057 12/10/2025 03:08:33 SOC:7514,67004,7766,114800,94,86,89,67 06058 12/10/2025 03:09:33 Discharge level 007 AH, SOC: 89%, I: 1A, L:4000, l:4012, H:4011, B:011, PT:020C, BT:024C, PV:112203, M:Bike On 06059 12/10/2025 03:09:33 SOC:7548,66967,7825,114800,94,89,89,14 06060 12/10/2025 03:10:33 Discharge level 007 AH, SOC: 89%, I: 1A, L:4006, l:4014, H:4017, B:011, PT:020C, BT:024C, PV:112370, M:Bike On 06061 12/10/2025 03:10:33 SOC:7563,67012,7842,114800,94,89,89,9 06062 12/10/2025 03:11:33 Discharge level 007 AH, SOC: 89%, I: 1A, L:4009, l:4015, H:4020, B:011, PT:020C, BT:024C, PV:112455, M:Bike On 06063 12/10/2025 03:11:33 SOC:7577,67095,7859,114800,94,89,89,6 06064 12/10/2025 03:12:33 Discharge level 007 AH, SOC: 89%, I: 1A, L:4011, l:4015, H:4021, B:010, PT:020C, BT:024C, PV:112505, M:Bike On 06065 12/10/2025 03:12:33 SOC:7588,67261,7875,114800,94,90,89,5 06066 12/10/2025 03:13:33 Discharge level 007 AH, SOC: 89%, I: 1A, L:4013, l:4017, H:4022, B:009, PT:020C, BT:024C, PV:112535, M:Bike On 06067 12/10/2025 03:13:34 SOC:7598,67476,7892,114800,94,90,89,4 06068 12/10/2025 03:14:33 Discharge level 007 AH, SOC: 89%, I: 1A, L:4014, l:4017, H:4023, B:009, PT:020C, BT:024C, PV:112562, M:Bike On 06069 12/10/2025 03:14:34 SOC:7605,67683,7909,114800,94,90,89,3 06070 12/10/2025 03:15:33 Discharge level 007 AH, SOC: 89%, I: 1A, L:4014, l:4017, H:4023, B:009, PT:020C, BT:024C, PV:112582, M:Bike On 06071 12/10/2025 03:15:34 SOC:7611,67883,7925,114800,94,90,89,3 06072 12/10/2025 03:16:34 Discharge level 007 AH, SOC: 89%, I: 1A, L:4015, l:4017, H:4024, B:009, PT:020C, BT:024C, PV:112596, M:Bike On 06073 12/10/2025 03:16:34 SOC:7618,68081,7941,114800,94,90,89,3 06074 12/10/2025 03:17:34 Discharge level 008 AH, SOC: 89%, I: 33A, L:3936, l:3964, H:3957, B:021, PT:020C, BT:025C, PV:110560, M:Bike On 06075 12/10/2025 03:17:34 SOC:7685,68183,8020,114800,94,85,89,32 06076 12/10/2025 03:18:34 Discharge level 008 AH, SOC: 89%, I: 80A, L:3853, l:3922, H:3886, B:033, PT:020C, BT:025C, PV:108378, M:Bike On 06077 12/10/2025 03:18:34 SOC:7952,67817,8365,114800,93,81,89,79 06078 12/10/2025 03:19:34 Discharge level 008 AH, SOC: 89%, I: 1A, L:3998, l:4008, H:4009, B:011, PT:020C, BT:025C, PV:112150, M:Bike On 06079 12/10/2025 03:19:34 SOC:8069,67674,8539,114800,93,89,89,11 06080 12/10/2025 03:20:34 Discharge level 008 AH, SOC: 89%, I: 1A, L:4001, l:4008, H:4011, B:010, PT:020C, BT:024C, PV:112225, M:Bike On 06081 12/10/2025 03:20:34 SOC:8118,67741,8604,114800,93,89,89,8 06082 12/10/2025 03:21:34 Discharge level 008 AH, SOC: 88%, I: 1A, L:3997, l:4007, H:4008, B:011, PT:020C, BT:023C, PV:112125, M:Bike On 06083 12/10/2025 03:21:34 SOC:8240,67655,8769,114800,93,89,88,11 06084 12/10/2025 03:22:34 Discharge level 009 AH, SOC: 88%, I: 27A, L:3954, l:3983, H:3970, B:016, PT:020C, BT:025C, PV:111003, M:Bike On 06085 12/10/2025 03:22:34 SOC:8473,67591,9005,114800,93,87,88,33 06086 12/10/2025 03:23:34 Discharge level 009 AH, SOC: 87%, I: 1A, L:3952, l:4000, H:3966, B:014, PT:020C, BT:023C, PV:110898, M:Bike On 06087 12/10/2025 03:23:34 SOC:9278,66888,9834,114800,92,88,87,53 06088 12/10/2025 03:24:34 Discharge level 011 AH, SOC: 85%, I: 77A, L:3811, l:3912, H:3843, B:032, PT:021C, BT:024C, PV:107198, M:Bike On 06089 12/10/2025 03:24:34 SOC:10517,65942,11091,114800,91,79,85,112 06090 12/10/2025 03:25:34 Discharge level 012 AH, SOC: 83%, I: 1A, L:3902, l:3970, H:3919, B:017, PT:021C, BT:025C, PV:109557, M:Bike On 06091 12/10/2025 03:25:34 SOC:11602,65066,12244,114800,90,85,83,76 06092 12/10/2025 03:26:34 Discharge level 012 AH, SOC: 82%, I: 62A, L:3836, l:3897, H:3867, B:031, PT:021C, BT:025C, PV:107905, M:Bike On 06093 12/10/2025 03:26:34 SOC:11746,64704,12601,114800,90,79,82,73 06094 12/10/2025 03:27:34 Discharge level 013 AH, SOC: 81%, I:136A, L:3708, l:3842, H:3755, B:047, PT:021C, BT:024C, PV:104554, M:Bike On 06095 12/10/2025 03:27:34 SOC:12762,63964,13726,114800,89,73,81,159 06096 12/10/2025 03:28:34 Discharge level 014 AH, SOC: 80%, I: 1A, L:3912, l:3941, H:3928, B:016, PT:022C, BT:025C, PV:109822, M:Bike On 06097 12/10/2025 03:28:34 SOC:12945,63607,14161,114800,88,83,80,34 06098 12/10/2025 03:29:34 Discharge level 014 AH, SOC: 80%, I:105A, L:3772, l:3851, H:3811, B:039, PT:022C, BT:025C, PV:106238, M:Bike On 06099 12/10/2025 03:29:34 SOC:12816,63372,14322,114800,88,74,80,93 06100 12/10/2025 03:30:34 Discharge level 015 AH, SOC: 78%, I: 1A, L:3877, l:3932, H:3893, B:016, PT:022C, BT:025C, PV:108853, M:Bike On 06101 12/10/2025 03:30:34 SOC:14081,62682,15685,114800,87,82,78,65 06102 12/10/2025 03:31:34 Discharge level 016 AH, SOC: 78%, I: 60A, L:3806, l:3868, H:3837, B:031, PT:022C, BT:024C, PV:107096, M:Bike On 06103 12/10/2025 03:31:34 SOC:14382,62694,16111,114800,86,76,78,74 06104 12/10/2025 03:32:34 Discharge level 016 AH, SOC: 76%, I: 57A, L:3776, l:3878, H:3807, B:031, PT:022C, BT:025C, PV:106247, M:Bike On 06105 12/10/2025 03:32:34 SOC:15175,62547,16970,114800,86,77,76,123 06106 12/10/2025 03:33:34 Discharge level 018 AH, SOC: 74%, I: 94A, L:3705, l:3837, H:3743, B:038, PT:023C, BT:023C, PV:104380, M:Bike On 06107 12/10/2025 03:33:34 SOC:16414,62169,18305,114800,85,72,74,159 06108 12/10/2025 03:34:34 Discharge level 020 AH, SOC: 70%, I:224A, L:3490, l:3750, H:3559, B:069, PT:024C, BT:025C, PV: 98851, M:Bike On 06109 12/10/2025 03:34:34 SOC:18941,61430,20847,114800,82,63,70,311 06110 12/10/2025 03:35:34 Discharge level 022 AH, SOC: 68%, I: 52A, L:3719, l:3821, H:3752, B:033, PT:024C, BT:025C, PV:104723, M:Bike On 06111 12/10/2025 03:35:34 SOC:20339,61643,22290,114800,81,71,68,126 06112 12/10/2025 03:36:34 Discharge level 024 AH, SOC: 63%, I:172A, L:3511, l:3737, H:3577, B:066, PT:025C, BT:025C, PV: 99470, M:Bike On 06113 12/10/2025 03:36:34 SOC:22893,61157,24847,114800,79,61,63,290 06114 12/10/2025 03:36:34 Discharge cutback 84% 06115 12/10/2025 03:36:34 719A 06116 12/10/2025 03:37:34 Discharge level 027 AH, SOC: 59%, I:172A, L:3477, l:3697, H:3547, B:070, PT:026C, BT:025C, PV: 98604, M:Bike On 06117 12/10/2025 03:37:34 SOC:25557,61024,27513,114800,77,56,59,298 06118 12/10/2025 03:37:34 Discharge cutback 83% 06119 12/10/2025 03:37:34 712A 06120 12/10/2025 03:38:34 Discharge level 029 AH, SOC: 56%, I: 2A, L:3652, l:3757, H:3687, B:035, PT:027C, BT:026C, PV:102950, M:Bike On 06121 12/10/2025 03:38:34 SOC:27335,61584,29307,114800,75,64,56,143 06122 12/10/2025 03:38:34 Discharge cutback 89% 06123 12/10/2025 03:38:34 766A 06124 12/10/2025 03:39:34 Discharge level 030 AH, SOC: 54%, I: 1A, L:3674, l:3764, H:3702, B:028, PT:027C, BT:025C, PV:103432, M:Bike On 06125 12/10/2025 03:39:34 SOC:28936,62230,30931,114800,74,65,54,129 06126 12/10/2025 03:39:34 Discharge cutback 84% 06127 12/10/2025 03:39:34 719A 06128 12/10/2025 03:40:34 Discharge level 032 AH, SOC: 52%, I:171A, L:3499, l:3667, H:3562, B:063, PT:028C, BT:026C, PV: 99121, M:Bike On 06129 12/10/2025 03:40:34 SOC:29979,62093,32392,114800,72,50,52,244 06130 12/10/2025 03:40:34 Discharge cutback 83% 06131 12/10/2025 03:40:34 712A 06132 12/10/2025 03:41:34 Discharge level 032 AH, SOC: 53%, I:-13A, L:3715, l:3750, H:3733, B:018, PT:028C, BT:026C, PV:104405, M:Bike On 06133 12/10/2025 03:41:34 SOC:30024,62650,32873,114800,72,63,53,53 06134 12/10/2025 03:42:34 Discharge level 033 AH, SOC: 53%, I: -5A, L:3712, l:3749, H:3728, B:016, PT:029C, BT:027C, PV:104273, M:Bike On 06135 12/10/2025 03:42:34 SOC:30057,62707,33513,114800,71,63,53,56 06136 12/10/2025 03:43:34 Discharge level 033 AH, SOC: 54%, I: 24A, L:3698, l:3731, H:3718, B:020, PT:029C, BT:027C, PV:103944, M:Bike On 06137 12/10/2025 03:43:34 SOC:29919,63798,33620,114800,71,61,54,50 06138 12/10/2025 03:44:34 Discharge level 033 AH, SOC: 54%, I:-10A, L:3734, l:3749, H:3745, B:011, PT:029C, BT:027C, PV:104785, M:Bike On 06139 12/10/2025 03:44:34 SOC:29784,64557,33805,114800,71,63,54,23 06140 12/10/2025 03:45:34 Discharge level 033 AH, SOC: 55%, I: 1A, L:3733, l:3744, H:3745, B:012, PT:029C, BT:026C, PV:104759, M:Bike On 06141 12/10/2025 03:45:34 SOC:29633,65651,33826,114800,71,63,55,17 06142 12/10/2025 03:45:40 Contactor was Opened Pack V: 104774mV, Switched V: 104723mV, Prechg Pct: 100%, Dischg Cur: 1091mA 06143 12/10/2025 03:45:41 System Turned Off 06144 12/10/2025 03:45:42 DEBUG: CAN Link Is Down 06145 12/10/2025 03:45:42 DEBUG: Entered Idle State 06146 12/10/2025 03:45:47 Current Sensor Zeroed old: 2504mV, new: 2506mV, corrfact: 250 06147 12/10/2025 03:45:49 Discharge level 033 AH, SOC: 55%, I: 0A, L:3735, l:3745, H:3746, B:011, PT:029C, BT:027C, PV:104806, M:Idle 06148 12/10/2025 03:45:49 SOC:29622,65805,33828,114800,71,63,55,16 06149 12/10/2025 03:46:10 Voltage Across Contactor: 90946mV (Okay) 06150 12/10/2025 05:18:38 System Turned On 06151 12/10/2025 05:18:38 Rev:45,Build:2023-05-20_045619 958 banka 06152 12/10/2025 05:18:38 Pack:2019_monolith,Numbricks:4 06153 12/10/2025 05:18:38 DEBUG: Entered Running State 06154 12/10/2025 05:18:38 DEBUG: CAN NOT Receiving Syncs 06155 12/10/2025 05:18:39 DEBUG: CAN Link Is Up 06156 12/10/2025 05:18:39 DEBUG: Resetting CAN0 due to error passive mode 06157 12/10/2025 05:18:39 Discharge level 033 AH, SOC: 55%, I: 0A, L:3764, l:3775, H:3771, B:007, PT:027C, BT:029C, PV:105505, M:Bike On 06158 12/10/2025 05:18:39 SOC:29614,65805,33828,114800,71,66,55,16 06159 12/10/2025 05:18:42 DEBUG: CAN Receiving Syncs 06160 12/10/2025 05:18:43 Contactor drive turned on Pack V: 105496mV, Switched V: 92593mV, Duty Cycle: 38% 06161 12/10/2025 05:18:43 Contactor was Closed Pack V: 105496mV, Switched V: 92593mV, Prechg Pct: 88%, Dischg Cur: 636mA 06162 12/10/2025 05:19:39 Discharge level 033 AH, SOC: 57%, I: 27A, L:3734, l:3755, H:3746, B:012, PT:027C, BT:029C, PV:104735, M:Bike On 06163 12/10/2025 05:19:39 SOC:29424,67108,33851,114800,71,64,57,30 06164 12/10/2025 05:20:39 Discharge level 034 AH, SOC: 57%, I: 36A, L:3720, l:3750, H:3730, B:010, PT:027C, BT:028C, PV:104316, M:Bike On 06165 12/10/2025 05:20:39 SOC:29452,68119,34100,114800,71,63,57,43 06166 12/10/2025 05:21:39 Discharge level 034 AH, SOC: 57%, I: 1A, L:3740, l:3758, H:3746, B:006, PT:027C, BT:029C, PV:104811, M:Bike On 06167 12/10/2025 05:21:39 SOC:29785,68838,34600,114800,70,64,57,26 06168 12/10/2025 05:22:39 Discharge level 035 AH, SOC: 57%, I:234A, L:3487, l:3627, H:3531, B:044, PT:027C, BT:029C, PV: 98295, M:Bike On 06169 12/10/2025 05:22:39 SOC:30169,68886,35319,114800,70,45,57,198 06170 12/10/2025 05:23:39 Discharge level 036 AH, SOC: 55%, I: 84A, L:3604, l:3695, H:3627, B:023, PT:027C, BT:029C, PV:101297, M:Bike On 06171 12/10/2025 05:23:39 SOC:31102,69051,36343,114800,69,56,55,130 06172 12/10/2025 05:23:39 Discharge cutback 89% 06173 12/10/2025 05:23:39 766A 06174 12/10/2025 05:24:39 Discharge level 037 AH, SOC: 54%, I: 33A, L:3658, l:3719, H:3672, B:014, PT:027C, BT:029C, PV:102668, M:Bike On 06175 12/10/2025 05:24:39 SOC:32002,69253,37330,114800,68,60,54,92 06176 12/10/2025 05:24:39 Discharge cutback 89% 06177 12/10/2025 05:24:39 763A 06178 12/10/2025 05:25:39 Discharge level 038 AH, SOC: 52%, I: 75A, L:3585, l:3672, H:3609, B:024, PT:027C, BT:029C, PV:100798, M:Bike On 06179 12/10/2025 05:25:39 SOC:33248,69225,38619,114800,67,53,52,132 06180 12/10/2025 05:25:39 Discharge cutback 86% 06181 12/10/2025 05:25:39 739A 06182 12/10/2025 05:26:39 Discharge level 039 AH, SOC: 51%, I: 1A, L:3665, l:3700, H:3678, B:013, PT:027C, BT:029C, PV:102844, M:Bike On 06183 12/10/2025 05:26:39 SOC:34117,69361,39628,114800,66,57,51,54 06184 12/10/2025 05:26:39 Discharge cutback 88% 06185 12/10/2025 05:26:39 756A 06186 12/10/2025 05:27:39 Discharge level 040 AH, SOC: 51%, I: 55A, L:3606, l:3666, H:3627, B:021, PT:027C, BT:028C, PV:101333, M:Bike On 06187 12/10/2025 05:27:39 SOC:34789,69655,40418,114800,65,52,51,92 06188 12/10/2025 05:27:39 Discharge cutback 87% 06189 12/10/2025 05:27:39 752A 06190 12/10/2025 05:28:39 Discharge level 041 AH, SOC: 50%, I: 0A, L:3656, l:3691, H:3668, B:012, PT:028C, BT:029C, PV:102603, M:Bike On 06191 12/10/2025 05:28:39 SOC:35424,69885,41203,114800,65,56,50,54 06192 12/10/2025 05:28:39 Discharge cutback 87% 06193 12/10/2025 05:28:40 746A 06194 12/10/2025 05:29:39 Discharge level 041 AH, SOC: 50%, I: 87A, L:3573, l:3647, H:3600, B:027, PT:028C, BT:029C, PV:100508, M:Bike On 06195 12/10/2025 05:29:39 SOC:35744,70255,41696,114800,64,50,50,113 06196 12/10/2025 05:29:39 Discharge cutback 87% 06197 12/10/2025 05:29:40 746A 06198 12/10/2025 05:30:39 Discharge level 042 AH, SOC: 48%, I: 35A, L:3601, l:3668, H:3621, B:020, PT:028C, BT:029C, PV:101219, M:Bike On 06199 12/10/2025 05:30:39 SOC:36865,69757,42986,114800,63,52,48,103 06200 12/10/2025 05:30:39 Discharge cutback 77% 06201 12/10/2025 05:30:40 661A 06202 12/10/2025 05:31:39 Discharge level 043 AH, SOC: 48%, I: 1A, L:3650, l:3674, H:3662, B:012, PT:028C, BT:029C, PV:102431, M:Bike On 06203 12/10/2025 05:31:39 SOC:36972,69987,43359,114800,63,53,48,37 06204 12/10/2025 05:31:40 Discharge cutback 86% 06205 12/10/2025 05:31:40 742A 06206 12/10/2025 05:32:39 Discharge level 043 AH, SOC: 48%, I: 0A, L:3650, l:3674, H:3663, B:013, PT:028C, BT:030C, PV:102481, M:Bike On 06207 12/10/2025 05:32:40 SOC:37046,70540,43590,114800,63,53,48,37 06208 12/10/2025 05:32:40 Discharge cutback 87% 06209 12/10/2025 05:32:40 752A 06210 12/10/2025 05:33:39 Discharge level 044 AH, SOC: 47%, I:470A, L:3214, l:3477, H:3313, B:099, PT:028C, BT:029C, PV: 91660, M:Bike On 06211 12/10/2025 05:33:40 SOC:37964,70363,44594,114800,62,8,47,405 06212 12/10/2025 05:33:40 Discharge cutback 65% 06213 12/10/2025 05:33:40 563A 06214 12/10/2025 05:34:39 Discharge level 045 AH, SOC: 45%, I: 1A, L:3623, l:3658, H:3638, B:015, PT:028C, BT:029C, PV:101750, M:Bike On 06215 12/10/2025 05:34:40 SOC:38807,70182,45603,114800,61,51,45,55 06216 12/10/2025 05:34:40 Discharge cutback 79% 06217 12/10/2025 05:34:40 682A 06218 12/10/2025 05:35:40 Discharge level 046 AH, SOC: 44%, I: 42A, L:3578, l:3633, H:3601, B:023, PT:028C, BT:029C, PV:100628, M:Bike On 06219 12/10/2025 05:35:40 SOC:39476,70399,46369,114800,60,47,44,86 06220 12/10/2025 05:35:40 Discharge cutback 78% 06221 12/10/2025 05:35:40 675A 06222 12/10/2025 05:36:40 Discharge level 047 AH, SOC: 43%, I: 1A, L:3603, l:3653, H:3620, B:017, PT:028C, BT:029C, PV:101249, M:Bike On 06223 12/10/2025 05:36:40 SOC:40249,698,57,32,42,137 06224 12/10/2025 05:42:40 Discharge level 050 AH, SOC: 42%, I: 1A, L:3614, l:3635, H:3629, B:015, PT:029C, BT:030C, PV:101521, M:Bike On 06225 12/10/2025 05:42:40 SOC:41203,70091,50259,114800,57,47,42,34 06226 12/10/2025 05:42:40 Discharge cutback 79% 06227 12/10/2025 05:42:40 678A 06228 12/10/2025 05:43:40 Discharge level 050 AH, SOC: 41%, I:283A, L:3333, l:3487, H:3402, B:069, PT:029C, BT:030C, PV: 94502, M:Bike On 06229 12/10/2025 05:43:40 SOC:41381,69767,50819,114800,56,12,41,250 06230 12/10/2025 05:43:40 Discharge cutback 72% 06231 12/10/2025 05:43:40 621A 06232 12/10/2025 05:44:40 Discharge level 051 AH, SOC: 41%, I:-24A, L:3638, l:3647, H:3649, B:011, PT:029C, BT:030C, PV:102103, M:Bike On 06233 12/10/2025 05:44:40 SOC:41097,69363,51098,114800,56,50,41,16 06234 12/10/2025 05:44:40 Discharge cutback 78% 06235 12/10/2025 05:44:40 668A 06236 12/10/2025 05:45:40 Discharge level 051 AH, SOC: 42%, I: 24A, L:3603, l:3621, H:3620, B:017, PT:029C, BT:029C, PV:101239, M:Bike On 06237 12/10/2025 05:45:40 SOC:40721,69280,51210,114800,56,45,42,30 06238 12/10/2025 05:45:40 Discharge cutback 83% 06239 12/10/2025 05:45:40 712A 06240 12/10/2025 05:46:40 Discharge level 051 AH, SOC: 42%, I:138A, L:3489, l:3564, H:3530, B:041, PT:029C, BT:030C, PV: 98452, M:Bike On 06241 12/10/2025 05:46:40 SOC:40550,68856,51544,114800,56,33,42,121 06242 12/10/2025 05:46:40 Discharge cutback 78% 06243 12/10/2025 05:46:40 671A 06244 12/10/2025 05:47:40 Discharge level 052 AH, SOC: 39%, I:125A, L:3462, l:3559, H:3505, B:043, PT:029C, BT:030C, PV: 97716, M:Bike On 06245 12/10/2025 05:47:40 SOC:41778,67758,52999,114800,54,32,39,158 06246 12/10/2025 05:47:40 Discharge cutback 67% 06247 12/10/2025 05:47:40 577A 06248 12/10/2025 05:48:40 Discharge level 053 AH, SOC: 39%, I: 1A, L:3600, l:3622, H:3616, B:016, PT:029C, BT:029C, PV:101149, M:Bike On 06249 12/10/2025 05:48:40 SOC:41765,67667,53359,114800,54,45,39,35 06250 12/10/2025 05:48:40 Discharge cutback 76% 06251 12/10/2025 05:48:40 658A 06252 12/10/2025 05:49:40 Discharge level 053 AH, SOC: 39%, I: 14A, L:3596, l:3615, H:3614, B:018, PT:029C, BT:030C, PV:101066, M:Bike On 06253 12/10/2025 05:49:40 SOC:41357,67502,53480,114800,54,43,39,30 06254 12/10/2025 05:49:40 Discharge cutback 80% 06255 12/10/2025 05:49:40 692A 06256 12/10/2025 05:50:40 Discharge level 054 AH, SOC: 39%, I: 39A, L:3565, l:3601, H:3588, B:023, PT:029C, BT:030C, PV:100286, M:Bike On 06257 12/10/2025 05:50:40 SOC:41892,67807,54098,114800,53,41,39,59 06258 12/10/2025 05:50:40 Discharge cutback 77% 06259 12/10/2025 05:50:40 665A 06260 12/10/2025 05:51:40 Discharge level 054 AH, SOC: 38%, I:285A, L:3315, l:3465, H:3391, B:076, PT:029C, BT:030C, PV: 94188, M:Bike On 06261 12/10/2025 05:51:40 SOC:42349,67775,54738,114800,53,7,38,243 06262 12/10/2025 05:51:40 Discharge cutback 67% 06263 12/10/2025 05:51:40 574A 06264 12/10/2025 05:52:40 Discharge level 055 AH, SOC: 38%, I:145A, L:3450, l:3540, H:3498, B:048, PT:029C, BT:030C, PV: 97489, M:Bike On 06265 12/10/2025 05:52:40 SOC:42641,67808,55243,114800,52,25,38,146 06266 12/10/2025 05:52:40 Discharge cutback 71% 06267 12/10/2025 05:52:40 611A 06268 12/10/2025 05:53:40 Discharge level 057 AH, SOC: 34%, I:136A, L:3414, l:3534, H:3464, B:050, PT:029C, BT:030C, PV: 96518, M:Bike On 06269 12/10/2025 05:53:40 SOC:44401,66402,57064,114800,51,22,34,193 06270 12/10/2025 05:53:40 Discharge cutback 60% 06271 12/10/2025 05:53:40 519A 06272 12/10/2025 05:54:40 Discharge level 059 AH, SOC: 29%, I:133A, L:3420, l:3539, H:3468, B:048, PT:030C, BT:030C, PV: 96642, M:Bike On 06273 12/10/2025 05:54:40 SOC:46497,64755,59207,114800,49,24,29,188 06274 12/10/2025 05:54:40 Discharge cutback 57% 06275 12/10/2025 05:54:40 489A 06276 12/10/2025 05:55:40 Discharge level 060 AH, SOC: 27%, I: 1A, L:3527, l:3591, H:3552, B:025, PT:030C, BT:030C, PV: 99272, M:Bike On 06277 12/10/2025 05:55:40 SOC:47620,64860,60427,114800,48,38,27,100 06278 12/10/2025 05:55:40 Discharge cutback 53% 06279 12/10/2025 05:55:40 455A 06280 12/10/2025 05:56:40 Discharge level 061 AH, SOC: 27%, I: 1A, L:3551, l:3590, H:3571, B:020, PT:030C, BT:030C, PV: 99863, M:Bike On 06281 12/10/2025 05:56:40 SOC:47943,64980,61202,114800,47,38,27,63 06282 12/10/2025 05:56:40 Discharge cutback 63% 06283 12/10/2025 05:56:40 540A 06284 12/10/2025 05:57:40 Discharge level 062 AH, SOC: 26%, I:118A, L:3419, l:3528, H:3465, B:046, PT:030C, BT:030C, PV: 96615, M:Bike On 06285 12/10/2025 05:57:40 SOC:48889,65195,62308,114800,46,20,26,176 06286 12/10/2025 05:57:40 Discharge cutback 56% 06287 12/10/2025 05:57:40 486A 06288 12/10/2025 05:58:40 Discharge level 063 AH, SOC: 24%, I: 1A, L:3526, l:3578, H:3549, B:023, PT:031C, BT:029C, PV: 99207, M:Bike On 06289 12/10/2025 05:58:40 SOC:49946,65290,63502,114800,45,36,24,84 06290 12/10/2025 05:58:40 Discharge cutback 60% 06291 12/10/2025 05:58:40 513A 06292 12/10/2025 05:59:40 Discharge level 064 AH, SOC: 23%, I: 1A, L:3522, l:3575, H:3545, B:023, PT:031C, BT:030C, PV: 99112, M:Bike On 06293 12/10/2025 05:59:40 SOC:50775,65265,64599,114800,44,35,23,84 06294 12/10/2025 05:59:40 Discharge cutback 57% 06295 12/10/2025 05:59:40 492A 06296 12/10/2025 06:00:40 Discharge level 064 AH, SOC: 24%, I: 1A, L:3552, l:3577, H:3572, B:020, PT:031C, BT:029C, PV: 99900, M:Bike On 06297 12/10/2025 06:00:40 SOC:50417,65980,64760,114800,44,36,24,41 06298 12/10/2025 06:00:40 Discharge cutback 68% 06299 12/10/2025 06:00:40 584A 06300 12/10/2025 06:01:40 Discharge level 064 AH, SOC: 26%, I: 1A, L:3568, l:3585, H:3584, B:016, PT:031C, BT:029C, PV:100266, M:Bike On 06301 12/10/2025 06:01:40 SOC:49446,66104,64706,114800,44,38,26,28 06302 12/10/2025 06:01:40 Discharge cutback 72% 06303 12/10/2025 06:01:40 621A 06304 12/10/2025 06:02:40 Discharge level 064 AH, SOC: 27%, I: 1A, L:3570, l:3586, H:3586, B:016, PT:031C, BT:030C, PV:100323, M:Bike On 06305 12/10/2025 06:02:40 SOC:48826,66391,64809,114800,44,38,27,26 06306 12/10/2025 06:02:40 Discharge cutback 72% 06307 12/10/2025 06:02:40 617A 06308 12/10/2025 06:03:40 Discharge level 064 AH, SOC: 29%, I: 1A, L:3576, l:3586, H:3592, B:016, PT:031C, BT:030C, PV:100474, M:Bike On 06309 12/10/2025 06:03:40 SOC:48582,67707,64823,114800,44,38,29,17 06310 12/10/2025 06:03:40 Discharge cutback 75% 06311 12/10/2025 06:03:40 641A 06312 12/10/2025 06:04:30 Contactor was Opened Pack V: 100547mV, Switched V: 100470mV, Prechg Pct: 100%, Dischg Cur: 727mA 06313 12/10/2025 06:04:30 System Turned Off 06314 12/10/2025 06:04:31 DEBUG: CAN Link Is Down 06315 12/10/2025 06:04:31 DEBUG: Entered Idle State 06316 12/10/2025 06:04:33 System Turned On 06317 12/10/2025 06:04:33 Rev:45,Build:2023-05-20_045619 958 banka 06318 12/10/2025 06:04:33 Pack:2019_monolith,Numbricks:4 06319 12/10/2025 06:04:33 DEBUG: Entered Running State 06320 12/10/2025 06:04:33 DEBUG: CAN NOT Receiving Syncs 06321 12/10/2025 06:04:33 DEBUG: CAN Link Is Up 06322 12/10/2025 06:04:34 DEBUG: Resetting CAN0 due to error passive mode 06323 12/10/2025 06:04:34 DEBUG: CAN Receiving Syncs 06324 12/10/2025 06:04:34 DEBUG: CAN NOT Receiving Syncs 06325 12/10/2025 06:04:37 DEBUG: CAN Receiving Syncs 06326 12/10/2025 06:04:37 Contactor drive turned on Pack V: 100557mV, Switched V: 89088mV, Duty Cycle: 40% 06327 12/10/2025 06:04:37 Contactor was Closed Pack V: 100557mV, Switched V: 89088mV, Prechg Pct: 89%, Dischg Cur: 636mA 06328 12/10/2025 06:04:40 Discharge level 064 AH, SOC: 30%, I: 1A, L:3579, l:3587, H:3595, B:016, PT:031C, BT:029C, PV:100561, M:Bike On 06329 12/10/2025 06:04:40 SOC:48445,68907,64841,114800,44,38,30,14 06330 12/10/2025 06:04:40 Discharge cutback 75% 06331 12/10/2025 06:04:40 644A 06332 12/10/2025 06:05:11 DEBUG: Entered Charging State 06333 12/10/2025 06:05:11 DEBUG: CAN NOT Receiving Syncs 06334 12/10/2025 06:05:12 Discharge level 064 AH, SOC: 31%, I: 0A, L:3579, l:3586, H:3596, B:017, PT:031C, BT:030C, PV:100593, M:Charge 06335 12/10/2025 06:05:12 SOC:48344,69388,64847,114800,44,38,31,12 06336 12/10/2025 06:05:12 DEBUG: CAN Receiving Syncs 06337 12/10/2025 06:15:12 Discharge level 062 AH, SOC: 39%, I:-12A, L:3625, l:3612, H:3638, B:013, PT:031C, BT:032C, PV:101796, M:Charge 06338 12/10/2025 06:15:12 SOC:36776,59974,62759,114800,46,43,39,-22 06339 12/10/2025 06:22:29 DEBUG: Resetting CAN0 due to error passive mode 06340 12/10/2025 06:25:12 Discharge level 060 AH, SOC: 46%, I:-12A, L:3641, l:3627, H:3653, B:012, PT:030C, BT:034C, PV:102213, M:Charge 06341 12/10/2025 06:25:12 SOC:30938,56256,60655,114800,48,46,46,-24 06342 12/10/2025 06:35:12 Discharge level 058 AH, SOC: 49%, I:-12A, L:3652, l:3638, H:3664, B:012, PT:030C, BT:034C, PV:102504, M:Charge 06343 12/10/2025 06:35:12 SOC:28747,56181,58555,114800,49,48,49,-23 06344 12/10/2025 06:45:12 Discharge level 056 AH, SOC: 52%, I:-12A, L:3663, l:3649, H:3673, B:010, PT:030C, BT:034C, PV:102758, M:Charge 06345 12/10/2025 06:45:12 SOC:27972,57500,56476,114800,51,50,52,-23 06346 12/10/2025 06:55:12 Discharge level 054 AH, SOC: 54%, I:-12A, L:3673, l:3659, H:3682, B:009, PT:030C, BT:035C, PV:103032, M:Charge 06347 12/10/2025 06:55:12 SOC:27989,59588,54421,114800,53,51,54,-23 06348 12/10/2025 07:05:12 Discharge level 052 AH, SOC: 55%, I:-12A, L:3685, l:3671, H:3692, B:007, PT:030C, BT:034C, PV:103312, M:Charge 06349 12/10/2025 07:05:12 SOC:27914,61592,52358,114800,55,53,55,-23 06350 12/10/2025 07:15:19 Discharge level 050 AH, SOC: 57%, I:-11A, L:3696, l:3682, H:3702, B:006, PT:030C, BT:035C, PV:103599, M:Charge 06351 12/10/2025 07:15:19 SOC:279iDEBUG: Entered Running State 06352 12/10/2025 07:39:06 DEBUG: CAN NOT Receiving Syncs 06353 12/10/2025 07:39:07 Discharge level 045 AH, SOC: 60%, I: 0A, L:3716, l:3708, H:3719, B:003, PT:030C, BT:039C, PV:104081, M:Bike On 06354 12/10/2025 07:39:07 SOC:27176,67755,45506,114800,61,58,60,-13 06355 12/10/2025 07:39:07 Discharge cutback 64% 06356 12/10/2025 07:39:07 546A 06357 12/10/2025 07:39:07 DEBUG: CAN Receiving Syncs 06358 12/10/2025 07:40:07 Discharge level 045 AH, SOC: 60%, I: 1A, L:3709, l:3707, H:3713, B:004, PT:030C, BT:038C, PV:103922, M:Bike On 06359 12/10/2025 07:40:07 SOC:27199,67450,45521,114800,61,58,60,-3 06360 12/10/2025 07:41:07 Discharge level 045 AH, SOC: 60%, I: 14A, L:3692, l:3699, H:3700, B:008, PT:030C, BT:038C, PV:103517, M:Bike On 06361 12/10/2025 07:41:07 SOC:27332,67129,45639,114800,61,57,60,11 06362 12/10/2025 07:42:07 Discharge level 045 AH, SOC: 59%, I: 1A, L:3698, l:3700, H:3705, B:007, PT:030C, BT:037C, PV:103667, M:Bike On 06363 12/10/2025 07:42:07 SOC:27508,66816,45779,114800,61,57,59,4 06364 12/10/2025 07:43:07 Discharge level 045 AH, SOC: 59%, I: 1A, L:3695, l:3698, H:3702, B:007, PT:030C, BT:037C, PV:103580, M:Bike On 06365 12/10/2025 07:43:07 SOC:27703,66474,45956,114800,60,57,59,6 06366 12/10/2025 07:43:16 DEBUG: Entered Charging State 06367 12/10/2025 07:43:16 DEBUG: CAN NOT Receiving Syncs 06368 12/10/2025 07:43:17 Discharge level 045 AH, SOC: 59%, I: 0A, L:3696, l:3699, H:3702, B:006, PT:030C, BT:036C, PV:103594, M:Charge 06369 12/10/2025 07:43:17 SOC:27715,66468,45956,114800,60,57,59,5 06370 12/10/2025 07:43:17 DEBUG: CAN Receiving Syncs 06371 12/10/2025 07:50:04 DEBUG: Entered Standby State 06372 12/10/2025 07:50:04 DEBUG: CAN NOT Receiving Syncs 06373 12/10/2025 07:50:05 System Turned Off 06374 12/10/2025 07:50:06 DEBUG: CAN Link Is Down 06375 12/10/2025 07:50:06 DEBUG: Entered Idle State 06376 12/10/2025 07:50:06 Contactor was Opened Pack V: 104987mV, Switched V: 104881mV, Prechg Pct: 100%, Dischg Cur: 636mA 06377 12/10/2025 07:50:07 System Turned On 06378 12/10/2025 07:50:07 Rev:45,Build:2023-05-20_045619 958 banka 06379 12/10/2025 07:50:07 Pack:2019_monolith,Numbricks:4 06380 12/10/2025 07:50:07 DEBUG: Entered Standby State 06381 12/10/2025 07:50:07 DEBUG: Entered Running State 06382 12/10/2025 07:50:07 DEBUG: CAN Link Is Up 06383 12/10/2025 07:50:08 DEBUG: Resetting CAN0 due to error passive mode 06384 12/10/2025 07:50:08 Discharge level 042 AH, SOC: 64%, I: 0A, L:3746, l:3726, H:3750, B:004, PT:030C, BT:040C, PV:104944, M:Bike On 06385 12/10/2025 07:50:08 SOC:24689,66978,42416,114800,64,61,64,-32 06386 12/10/2025 07:50:08 Discharge cutback 69% 06387 12/10/2025 07:50:08 597A 06388 12/10/2025 07:50:09 DEBUG: CAN Receiving Syncs 06389 12/10/2025 07:50:09 DEBUG: CAN NOT Receiving Syncs 06390 12/10/2025 07:50:11 DEBUG: CAN Receiving Syncs 06391 12/10/2025 07:50:11 Contactor drive turned on Pack V: 104907mV, Switched V: 92987mV, Duty Cycle: 38% 06392 12/10/2025 07:50:11 Contactor was Closed Pack V: 104907mV, Switched V: 92987mV, Prechg Pct: 89%, Dischg Cur: 727mA 06393 12/10/2025 07:51:08 Discharge level 042 AH, SOC: 63%, I: 32A, L:3708, l:3716, H:3714, B:006, PT:031C, BT:039C, PV:103932, M:Bike On 06394 12/10/2025 07:51:08 SOC:24819,66676,42502,114800,63,59,63,12 06395 12/10/2025 07:52:08 Discharge level 042 AH, SOC: 63%, I:-12A, L:3733, l:3728, H:3737, B:004, PT:031C, BT:038C, PV:104578, M:Bike On 06396 12/10/2025 07:52:08 SOC:25079,66212,42736,114800,63,61,63,-8 06397 12/10/2025 07:53:08 Discharge level 042 AH, SOC: 62%, I: 1A, L:3722, l:3722, H:3727, B:005, PT:031C, BT:037C, PV:104294, M:Bike On 06398 12/10/2025 07:53:08 SOC:25145,65913,42776,114800,63,60,62,0 06399 12/10/2025 07:53:15 DEBUG: Entered Charging State 06400 12/10/2025 07:53:15 DEBUG: CAN NOT Receiving Syncs 06401 12/10/2025 07:53:16 Discharge level 042 AH, SOC: 62%, I: 0A, L:3722, l:3722, H:3727, B:005, PT:031C, BT:036C, PV:104293, M:Charge 06402 12/10/2025 07:53:16 SOC:25156,65907,42776,114800,63,60,62,0 06403 12/10/2025 07:53:16 DEBUG: CAN Receiving Syncs 06404 12/10/2025 08:03:16 Discharge level 037 AH, SOC: 69%, I:-31A, L:3813, l:3775, H:3827, B:014, PT:031C, BT:042C, PV:106928, M:Charge 06405 12/10/2025 08:03:16 SOC:21561,67499,37588,114800,68,67,69,-58 06406 12/10/2025 08:13:16 Discharge level 032 AH, SOC: 74%, I:-31A, L:3866, l:3829, H:3880, B:014, PT:032C, BT:043C, PV:108399, M:Charge 06407 12/10/2025 08:13:16 SOC:18574,69646,32468,114800,72,72,74,-58 06408 12/10/2025 08:23:16 Discharge level 027 AH, SOC: 79%, I:-29A, L:3921, l:3886, H:3930, B:009, PT:032C, BT:043C, PV:109893, M:Charge 06409 12/10/2025 08:23:16 SOC:15243,71322,27476,114800,77,78,79,-56 06410 12/10/2025 08:33:24 Discharge level 022 AH, SOC: 84%, I:-30A, L:3974, l:3941, H:3981, B:007, PT:032C, BT:049C, PV:111360, M:Charge 06411 12/10/2025 08:33:24 SOC:11911,72990,22490,114800,81,83,84,-56 06412 12/10/2025 08:43:24 Discharge level 017 AH, SOC: 89%, I:-28A, L:4023, l:3992, H:4030, B:007, PT:033C, BT:047C, PV:112718, M:Charge 06413 12/10/2025 08:43:24 SOC:8802,74799,17589,114800,85,87,89,-54 06414 12/10/2025 08:45:35 Charged To Full 016 AH, SOC: 90%, L:4033, H:4041, B:008, PT:033C, BT:048C, PV:112755 06415 12/10/2025 08:45:35 SOC adjusted for voltage old: 8117176uAH (soc:90%), new: 6766487uAH (soc:91%), low cell: 4033 mV 06416 12/10/2025 08:53:24 Discharge level 006 AH, SOC: 94%, I:-28A, L:4073, l:4044, H:4081, B:008, PT:033C, BT:047C, PV:114121, M:Charge 06417 12/10/2025 08:53:24 SOC:5354,77554,6561,114800,95,92,94,-54 06418 12/10/2025 09:03:24 Discharge level 001 AH, SOC: 98%, I:-29A, L:4122, l:4093, H:4131, B:009, PT:033C, BT:049C, PV:115508, M:Charge 06419 12/10/2025 09:03:24 SOC:1950,78888,1839,114800,99,97,98,-54 06420 12/10/2025 09:13:24 Discharge level 000 AH, SOC:100%, I:-15A, L:4151, l:4133, H:4156, B:005, PT:033C, BT:048C, PV:116269, M:Charge 06421 12/10/2025 09:13:24 SOC:0,79503,0,114800,100,100,100,-33 06422 12/10/2025 09:23:24 Discharge level 000 AH, SOC:100%, I: -8A, L:4155, l:4147, H:4158, B:003, PT:033C, BT:043C, PV:116372, M:Charge 06423 12/10/2025 09:23:24 SOC:0,79503,0,114800,100,100,100,-15 06424 12/10/2025 09:33:42 DEBUG: Entered Standby State 06425 12/10/2025 09:33:42 DEBUG: CAN NOT Receiving Syncs 06426 12/10/2025 09:33:43 System Turned Off 06427 12/10/2025 09:33:44 DEBUG: CAN Link Is Down 06428 12/10/2025 09:33:44 DEBUG: Entered Idle State 06429 12/10/2025 09:33:44 Contactor was Opened Pack V: 116274mV, Switched V: 116184mV, Prechg Pct: 100%, Dischg Cur: 636mA 06430 12/10/2025 09:33:50 Current Sensor Zeroed old: 2506mV, new: 2508mV, corrfact: 248 06431 12/10/2025 09:33:50 Current Sensor Zeroed old: 2504mV, new: 2505mV, corrfact: 251 06432 12/10/2025 09:33:51 Discharge level 000 AH, SOC:100%, I: 0A, L:4151, l:4149, H:4154, B:003, PT:032C, BT:042C, PV:116258, M:Idle 06433 12/10/2025 09:33:52 SOC:0,79503,0,114800,100,100,100,-4 06434 12/10/2025 09:34:12 Voltage Across Contactor: 103193mV (Okay) 06435 12/10/2025 11:24:50 System Turned On 06436 12/10/2025 11:24:50 Rev:45,Build:2023-05-20_045619 958 banka 06437 12/10/2025 11:24:50 Pack:2019_monolith,Numbricks:4 06438 12/10/2025 11:24:50 DEBUG: Entered Standby State 06439 12/10/2025 11:24:51 DEBUG: CAN Link Is Up 06440 12/10/2025 11:24:51 DEBUG: Entered Running State 06441 12/10/2025 11:24:51 DEBUG: Resetting CAN0 due to error passive mode 06442 12/10/2025 11:24:52 Discharge level 000 AH, SOC:100%, I: 0A, L:4131, l:4129, H:4137, B:006, PT:029C, BT:030C, PV:115774, M:Bike On 06443 12/10/2025 11:24:52 SOC:0,79503,0,114800,100,100,100,-3 06444 12/10/2025 11:24:54 DEBUG: CAN Receiving Syncs 06445 12/10/2025 11:24:55 Contactor drive turned on Pack V: 115766mV, Switched V: 101376mV, Duty Cycle: 34% 06446 12/10/2025 11:24:55 Contactor was Closed Pack V: 115766mV, Switched V: 101376mV, Prechg Pct: 88%, Dischg Cur: 454mA 06447 12/10/2025 11:25:52 Discharge level 000 AH, SOC:100%, I: 0A, L:4130, l:4130, H:4137, B:007, PT:028C, BT:030C, PV:115763, M:Bike On 06448 12/10/2025 11:25:52 SOC:0,79503,0,114800,100,100,100,0 06449 12/10/2025 11:26:52 Discharge level 000 AH, SOC:100%, I: 0A, L:4130, l:4130, H:4136, B:006, PT:028C, BT:031C, PV:115752, M:Bike On 06450 12/10/2025 11:26:52 SOC:0,79503,0,114800,100,100,100,0 06451 12/10/2025 11:27:52 Discharge level 000 AH, SOC:100%, I: 0A, L:4130, l:4130, H:4136, B:006, PT:028C, BT:031C, PV:115746, M:Bike On 06452 12/10/2025 11:27:52 SOC:0,79503,0,114800,100,100,100,0 06453 12/10/2025 11:28:52 Discharge level 000 AH, SOC:100%, I: 1A, L:4117, l:4125, H:4125, B:008, PT:028C, BT:030C, PV:115435, M:Bike On 06454 12/10/2025 11:28:52 SOC:75,79446,77,114800,100,100,100,13 06455 12/10/2025 11:29:52 Discharge level 000 AH, SOC:100%, I: 2A, L:4113, l:4122, H:4121, B:008, PT:028C, BT:031C, PV:115313, M:Bike On 06456 12/10/2025 11:29:52 SOC:395,79138,407,114800,100,100,100,14 06457 12/10/2025 11:30:52 Discharge level 000 AH, SOC:100%, I: 1A, L:4112, l:4123, H:4120, B:008, PT:028C, BT:030C, PV:115272, M:Bike On 06458 12/10/2025 11:30:52 SOC:465,78965,513,114800,100,100,100,17 06459 12/10/2025 11:31:52 Discharge level 000 AH, SOC:100%, I: 39A, L:4057, l:4088, H:4077, B:020, PT:028C, BT:030C, PV:113925, M:Bike On 06460 12/10/2025 11:31:52 SOC:633,78706,710,114800,100,96,100,47 06461 12/10/2025 11:32:52 Discharge level 000 AH, SOC:100%, I: 1A, L:4112, l:4116, H:4120, B:008, PT:028C, BT:030C, PV:115278, M:Bike On 06462 12/10/2025 11:32:52 SOC:684,78553,795,114800,100,99,100,6 06463 12/10/2025 11:33:52 Discharge level 000 AH, SOC: 99%, I: 80A, L:4015, l:4058, H:4041, B:026, PT:028C, BT:030C, PV:112850, M:Bike On 06464 12/10/2025 11:33:52 SOC:865,78338,985,114800,100,93,99,67 06465 12/10/2025 11:34:52 Discharge level 002 AH, SOC: 98%, I: 80A, L:3960, l:4039, H:3996, B:036, PT:028C, BT:030C, PV:111510, M:Bike On 06466 12/10/2025 11:34:52 SOC:1900,77339,2032,114800,99,91,98,122 06467 12/10/2025 11:35:52 Discharge level 003 AH, SOC: 97%, I: 60A, L:3972, l:4039, H:4004, B:032, PT:028C, BT:030C, PV:111786, M:Bike On 06468 12/10/2025 11:35:52 SOC:2885,76372,3015,114800,98,91,97,103 06469 12/10/2025 11:36:52 Discharge level 004 AH, SOC: 95%, I: 79A, L:3930, l:4007, H:3970, B:040, PT:029C, BT:028C, PV:110768, M:Bike On 06470 12/10/2025 11:36:52 SOC:4010,75284,4137,114800,97,88,95,120 06471 12/10/2025 11:37:52 Discharge level 005 AH, SOC: 94%, I: 26A, L:3986, l:4046, H:4011, B:025, PT:029C, BT:029C, PV:112075, M:Bike On 06472 12/10/2025 11:37:52 SOC:5187,74193,5314,114800,96,92,94,92 06473 12/10/2025 11:38:52 Discharge level 006 AH, SOC: 92%, I:112A, L:3875, l:3973, H:3920, B:045, PT:029C, BT:028C, PV:109326, M:Bike On 06474 12/10/2025 11:38:52 SOC:6199,73382,6325,114800,95,85,92,149 06475 12/10/2025 11:39:52 Discharge level 968 AH, SOC:105%, I:942A, L:3831, l:13868, H:3881, B:050, PT:029C, BT:029C, PV:977489747, M:None 06476 12/10/2025 11:43:52 Discharge level 016 AH, SOC: 77%, I: 99A, L:3724, l:3880, H:3784, B:060, PT:031C, BT:029C, PV:105444, M:Bike On 06477 12/10/2025 11:43:52 Discharge level 016 AH, SOC: 77%, I: 99A, L:3724, l:3880, H:3784, B:060, PT:031C, BT:029C, PV:105444, M:Bike On 06478 12/10/2025 11:43:52 SOC:16212,68765,16351,114800,86,76,77,226 06479 12/10/2025 11:44:52 Discharge level 018 AH, SOC: 73%, I:177A, L:3624, l:3817, H:3702, B:078, PT:032C, BT:028C, PV:103011, M:Bike On 06480 12/10/2025 11:44:52 SOC:18799,68231,18973,114800,84,69,73,288 06481 12/10/2025 11:45:52 Discharge level 022 AH, SOC: 68%, I:170A, L:3579, l:3792, H:3663, B:084, PT:033C, BT:028C, PV:101893, M:Bike On 06482 12/10/2025 11:45:52 SOC:21902,67714,22078,114800,81,66,68,323 06483 12/10/2025 11:46:52 Discharge level 024 AH, SOC: 64%, I: 2A, L:3730, l:3838, H:3772, B:042, PT:033C, BT:028C, PV:105301, M:Bike On 06484 12/10/2025 11:46:52 SOC:24546,67598,24743,114800,79,72,64,174 06485 12/10/2025 11:47:52 Discharge level 027 AH, SOC: 60%, I:332A, L:3427, l:3668, H:3538, B:111, PT:034C, BT:027C, PV: 98181, M:Bike On 06486 12/10/2025 11:47:52 SOC:27375,67414,27592,114800,76,51,60,420 06487 12/10/2025 11:47:52 Discharge cutback 87% 06488 12/10/2025 11:47:52 749A 06489 12/10/2025 11:48:52 Discharge level 030 AH, SOC: 56%, I:151A, L:3535, l:3704, H:3613, B:078, PT:035C, BT:027C, PV:100574, M:Bike On 06490 12/10/2025 11:48:52 SOC:30090,67592,30315,114800,74,57,56,307 06491 12/10/2025 11:48:52 Discharge cutback 82% 06492 12/10/2025 11:48:52 709A 06493 12/10/2025 11:49:52 Discharge level 032 AH, SOC: 53%, I:415A, L:3342, l:3597, H:3469, B:127, PT:036C, BT:028C, PV: 96169, M:Bike On 06494 12/10/2025 11:49:52 SOC:32289,67664,32653,114800,72,38,53,469 06495 12/10/2025 11:49:52 Discharge cutback 73% 06496 12/10/2025 11:49:52 628A 06497 12/10/2025 11:50:52 Discharge level 033 AH, SOC: 52%, I: 67A, L:3628, l:3717, H:3675, B:047, PT:036C, BT:029C, PV:102586, M:Bike On 06498 12/10/2025 11:50:52 SOC:33506,68791,33919,114800,71,59,52,167 06499 12/10/2025 11:51:52 Discharge level 035 AH, SOC: 51%, I: 77A, L:3626, l:3708, H:3671, B:045, PT:037C, BT:029C, PV:102461, M:Bike On 06500 12/10/2025 11:51:52 SOC:34493,69834,35035,114800,70,58,51,154 06501 12/10/2025 11:52:52 Discharge level 038 AH, SOC: 46%, I:200A, L:3455, l:3624, H:3539, B:084, PT:038C, BT:028C, PV: 98468, M:Bike On 06502 12/10/2025 11:52:52 SOC:37618,69411,38168,114800,67,45,46,327 06503 12/10/2025 11:52:52 Discharge cutback 70% 06504 12/10/2025 11:52:52 601A 06505 12/10/2025 11:53:52 Discharge level 039 AH, SOC: 44%, I: 0A, L:3624, l:3688, H:3659, B:035, PT:038C, BT:029C, PV:102239, M:Bike On 06506 12/10/2025 11:53:52 SOC:39089,69578,39920,114800,66,55,44,124 06507 12/10/2025 11:53:52 Discharge cutback 78% 06508 12/10/2025 11:53:52 668A 06509 12/10/2025 11:54:52 Discharge level 040 AH, SOC: 46%, I: 83A, L:3605, l:3667, H:3648, B:043, PT:038C, BT:028C, PV:101850, M:Bike On 06510 12/10/2025 11:54:52 SOC:38669,70333,40091,114800,66,52,46,119 06511 12/10/2025 11:54:52 Discharge cutback 89% 06512 12/10/2025 11:54:52 769A 06513 12/10/2025 11:55:31 Contactor was Opened Pack V: 103407mV, Switched V: 103345mV, Prechg Pct: 100%, Dischg Cur: 818mA 06514 12/10/2025 11:55:32 System Turned Off 06515 12/10/2025 11:55:33 DEBUG: CAN Link Is Down 06516 12/10/2025 11:55:33 DEBUG: Entered Idle State 06517 12/10/2025 11:55:38 Current Sensor Zeroed old: 2508mV, new: 2507mV, corrfact: 249 06518 12/10/2025 11:55:39 Current Sensor Zeroed old: 2505mV, new: 2504mV, corrfact: 252 06519 12/10/2025 11:55:40 Discharge level 040 AH, SOC: 47%, I: 0A, L:3678, l:3700, H:3700, B:022, PT:038C, BT:028C, PV:103467, M:Idle 06520 12/10/2025 11:55:40 SOC:38519,71398,40106,114800,66,57,47,43 06521 12/10/2025 11:56:01 Voltage Across Contactor: 90594mV (Okay) 06522 12/10/2025 11:56:27 System Turned On 06523 12/10/2025 11:56:27 Rev:45,Build:2023-05-20_045619 958 banka 06524 12/10/2025 11:56:27 Pack:2019_monolith,Numbricks:4 06525 12/10/2025 11:56:27 DEBUG: Entered Running State 06526 12/10/2025 11:56:27 DEBUG: CAN NOT Receiving Syncs 06527 12/10/2025 11:56:27 DEBUG: CAN Link Is Up 06528 12/10/2025 11:56:28 DEBUG: Resetting CAN0 due to error passive mode 06529 12/10/2025 11:56:28 Discharge level 040 AH, SOC: 47%, I: 0A, L:3686, l:3708, H:3705, B:019, PT:038C, BT:028C, PV:103629, M:Bike On 06530 12/10/2025 11:56:28 SOC:38510,71398,40106,114800,66,58,47,43 06531 12/10/2025 11:56:31 DEBUG: CAN Receiving Syncs 06532 12/10/2025 11:56:36 DEBUG: Entered Charging State 06533 12/10/2025 11:56:36 Contactor drive turned on Pack V: 103645mV, Switched V: 89993mV, Duty Cycle: 38% 06534 12/10/2025 11:56:37 Contactor was Closed Pack V: 103645mV, Switched V: 89993mV, Prechg Pct: 87%, Dischg Cur: 545mA 06535 12/10/2025 11:56:37 DEBUG: CAN NOT Receiving Syncs 06536 12/10/2025 11:56:38 Discharge level 040 AH, SOC: 47%, I: 0A, L:3687, l:3707, H:3706, B:019, PT:038C, BT:030C, PV:103646, M:Charge 06537 12/10/2025 11:56:38 SOC:38399,71408,40106,114800,66,58,47,40 06538 12/10/2025 11:56:38 DEBUG: CAN Link Is Down 06539 12/10/2025 11:56:38 Contactor was Opened Pack V: 103645mV, Switched V: 103620mV, Prechg Pct: 100%, Dischg Cur: 909mA 06540 12/10/2025 11:56:38 DEBUG: CAN Link Is Up 06541 12/10/2025 11:56:38 DEBUG: CAN Receiving Syncs 06542 12/10/2025 11:56:40 DEBUG: Entered Running State 06543 12/10/2025 11:56:40 DEBUG: CAN NOT Receiving Syncs 06544 12/10/2025 11:56:41 Discharge level 040 AH, SOC: 47%, I: 0A, L:3687, l:3707, H:3706, B:019, PT:038C, BT:029C, PV:103657, M:Bike On 06545 12/10/2025 11:56:41 SOC:38385,71408,40106,114800,66,58,47,39 06546 12/10/2025 11:56:41 Discharge cutback 85% 06547 12/10/2025 11:56:41 729A 06548 12/10/2025 11:56:41 DEBUG: CAN Receiving Syncs 06549 12/10/2025 11:56:42 System Turned Off 06550 12/10/2025 11:56:42 DEBUG: CAN Link Is Down 06551 12/10/2025 11:56:43 DEBUG: Entered Idle State 06552 12/10/2025 11:56:45 System Turned On 06553 12/10/2025 11:56:45 Rev:45,Build:2023-05-20_045619 958 banka 06554 12/10/2025 11:56:45 Pack:2019_monolith,Numbricks:4 06555 12/10/2025 11:56:45 DEBUG: Entered Running State 06556 12/10/2025 11:56:45 DEBUG: CAN NOT Receiving Syncs 06557 12/10/2025 11:56:46 DEBUG: CAN Link Is Up 06558 12/10/2025 11:56:46 DEBUG: Resetting CAN0 due to error passive mode 06559 12/10/2025 11:56:49 DEBUG: CAN Receiving Syncs 06560 12/10/2025 11:56:50 DEBUG: Entered Charging State 06561 12/10/2025 11:56:50 DEBUG: CAN NOT Receiving Syncs 06562 12/10/2025 11:56:50 Contactor drive turned on Pack V: 103675mV, Switched V: 89560mV, Duty Cycle: 38% 06563 12/10/2025 11:56:50 Contactor was Closed Pack V: 103675mV, Switched V: 89560mV, Prechg Pct: 86%, Dischg Cur: 545mA 06564 12/10/2025 11:56:51 Discharge level 040 AH, SOC: 47%, I: 0A, L:3688, l:3707, H:3707, B:019, PT:038C, BT:028C, PV:103676, M:Charge 06565 12/10/2025 11:56:51 SOC:38301,71413,40106,114800,66,58,47,37 06566 12/10/2025 11:56:51 DEBUG: CAN Receiving Syncs 06567 12/10/2025 12:06:51 Discharge level 034 AH, SOC: 64%, I:-32A, L:3797, l:3765, H:3806, B:009, PT:038C, BT:038C, PV:106420, M:Charge 06568 12/10/2025 12:06:51 SOC:22103,60509,34909,114800,70,65,64,-57 06569 12/10/2025 12:16:51 Discharge level 029 AH, SOC: 73%, I:-30A, L:3859, l:3825, H:3871, B:012, PT:038C, BT:042C, PV:108171, M:Charge 06570 12/10/2025 12:16:51 SOC:16535,60113,29751,114800,75,72,73,-58 06571 12/10/2025 12:26:51 Discharge level 024 AH, SOC: 80%, I:-30A, L:3922, l:3889, H:3928, B:006, PT:038C, BT:046C, PV:109895, M:Charge 06572 12/10/2025 12:26:51 SOC:12782,61408,24716,114800,79,78,80,-57 06573 12/10/2025 12:36:59 Discharge level 019 AH, SOC: 85%, I:-29A, L:3978, l:3947, H:3982, B:004, PT:038C, BT:048C, PV:111447, M:Charge 06574 12/10/2025 12:36:59 SOC:9701,63351,19708,114800,83,83,85,-55 06575 12/10/2025 12:46:36 Charged To Full 015 AH, SOC: 90%, L:4028, H:4033, B:005, PT:037C, BT:046C, PV:112748 06576 12/10/2025 12:46:37 SOC adjusted for voltage old: 6991646uAH (soc:90%), new: 5881079uAH (soc:91%), low cell: 4028 mV 06577 12/10/2025 12:46:59 Discharge level 010 AH, SOC: 92%, I:-29A, L:4030, l:4001, H:4036, B:006, PT:037C, BT:045C, PV:112905, M:Charge 06578 12/10/2025 12:46:59 SOC:5895,65540,10151,114800,92,88,92,-55 06579 12/10/2025 12:56:59 Discharge level 005 AH, SOC: 95%, I:-28A, L:4083, l:4055, H:4090, B:007, PT:037C, BT:047C, PV:114400, M:Charge 06580 12/10/2025 12:56:59 SOC:3892,68362,5343,114800,96,93,95,-54 06581 12/10/2025 13:06:59 Discharge level 000 AH, SOC:100%, I:-28A, L:4136, l:4107, H:4145, B:009, PT:036C, BT:050C, PV:115883, M:Charge 06582 12/10/2025 13:06:59 SOC:673,69889,616,114800,100,98,100,-53 06583 12/10/2025 13:16:59 Discharge level 000 AH, SOC:100%, I:-12A, L:4153, l:4140, H:4157, B:004, PT:036C, BT:045C, PV:116333, M:Charge 06584 12/10/2025 13:16:59 SOC:0,70195,0,114800,100,100,100,-25 06585 12/10/2025 13:30:07 DEBUG: Entered Standby State 06586 12/10/2025 13:30:07 DEBUG: CAN NOT Receiving Syncs 06587 12/10/2025 13:30:08 System Turned Off 06588 12/10/2025 13:30:09 DEBUG: CAN Link Is Down 06589 12/10/2025 13:30:09 DEBUG: Entered Idle State 06590 12/10/2025 13:30:09 Contactor was Opened Pack V: 116271mV, Switched V: 116184mV, Prechg Pct: 100%, Dischg Cur: 818mA 06591 12/10/2025 13:30:15 Current Sensor Zeroed old: 2507mV, new: 2510mV, corrfact: 246 06592 12/10/2025 13:30:15 Current Sensor Zeroed old: 2504mV, new: 2506mV, corrfact: 250 06593 12/10/2025 13:30:16 Discharge level 000 AH, SOC:100%, I: 0A, L:4149, l:4147, H:4154, B:005, PT:035C, BT:041C, PV:116251, M:Idle 06594 12/10/2025 13:30:17 SOC:0,70195,0,114800,100,100,100,-4 06595 12/10/2025 13:30:37 Voltage Across Contactor: 103231mV (Okay) 06596 12/10/2025 21:47:54 System Turned On 06597 12/10/2025 21:47:54 Rev:45,Build:2023-05-20_045619 958 banka 06598 12/10/2025 21:47:54 Pack:2019_monolith,Numbricks:4 06599 12/10/2025 21:47:54 DEBUG: Entered Standby State 06600 12/10/2025 21:47:54 DEBUG: CAN Link Is Up 06601 12/10/2025 21:47:54 DEBUG: Entered Running State 06602 12/10/2025 21:47:55 DEBUG: Resetting CAN0 due to error passive mode 06603 12/10/2025 21:47:55 Discharge level 000 AH, SOC:100%, I: 0A, L:4126, l:4122, H:4133, B:007, PT:016C, BT:019C, PV:115655, M:Bike On 06604 12/10/2025 21:47:55 SOC:0,70195,0,114800,100,100,100,-4 06605 12/10/2025 21:47:58 DEBUG: CAN Receiving Syncs 06606 12/10/2025 21:47:58 Contactor drive turned on Pack V: 115605mV, Switched V: 101100mV, Duty Cycle: 34% 06607 12/10/2025 21:47:58 Contactor was Closed Pack V: 115605mV, Switched V: 101100mV, Prechg Pct: 87%, Dischg Cur: 272mA 06608 12/10/2025 21:48:55 Discharge level 000 AH, SOC:100%, I: 0A, L:4125, l:4124, H:4131, B:006, PT:016C, BT:020C, PV:115593, M:Bike On 06609 12/10/2025 21:48:55 SOC:1,70195,4,114800,100,100,100,0 06610 12/10/2025 21:49:55 Discharge level 000 AH, SOC:100%, I: 0A, L:4123, l:4123, H:4130, B:007, PT:016C, BT:020C, PV:115579, M:Bike On 06611 12/10/2025 21:49:55 SOC:4,70195,9,114800,100,100,100,0 06612 12/10/2025 21:50:55 Discharge level 000 AH, SOC:100%, I: 1A, L:4123, l:4123, H:4130, B:007, PT:016C, BT:019C, PV:115560, M:Bike On 06613 12/10/2025 21:50:55 SOC:8,70195,15,114800,100,100,100,0 06614 12/10/2025 21:51:55 Discharge level 000 AH, SOC:100%, I: 0A, L:4113, l:4120, H:4121, B:008, PT:016C, BT:019C, PV:115299, M:Bike On 06615 12/10/2025 21:51:55 SOC:169,69957,152,114800,100,99,100,6 06616 12/10/2025 21:52:55 Discharge level 000 AH, SOC:100%, I: 1A, L:4076, l:4099, H:4087, B:011, PT:016C, BT:019C, PV:114308, M:Bike On 06617 12/10/2025 21:52:55 SOC:635,69159,602,114800,100,97,100,20 06618 12/10/2025 21:53:55 Discharge level 002 AH, SOC: 97%, I: 88A, L:3806, l:3963, H:3851, B:045, PT:016C, BT:019C, PV:107255, M:Bike On 06619 12/10/2025 21:53:55 SOC:2198,67246,2141,114800,99,84,97,137 06620 12/10/2025 21:54:55 Discharge level 003 AH, SOC: 95%, I: 1A, L:3913, l:4017, H:3942, B:029, PT:017C, BT:019C, PV:110035, M:Bike On 06621 12/10/2025 21:54:55 SOC:3732,65383,3667,114800,97,90,95,96 06622 12/10/2025 21:55:55 Discharge level 004 AH, SOC: 94%, I:110A, L:3851, l:3993, H:3893, B:042, PT:017C, BT:019C, PV:108499, M:Bike On 06623 12/10/2025 21:55:55 SOC:4348,64516,4331,114800,97,87,94,130 06624 12/10/2025 21:56:55 Discharge level 004 AH, SOC: 93%, I: 1A, L:3997, l:4036, H:4016, B:019, PT:018C, BT:019C, PV:112259, M:Bike On 06625 12/10/2025 21:56:55 SOC:4886,63792,4922,114800,96,91,93,38 06626 12/10/2025 21:57:55 Discharge level 005 AH, SOC: 92%, I: 53A, L:3880, l:3974, H:3918, B:038, PT:018C, BT:019C, PV:109278, M:Bike On 06627 12/10/2025 21:57:55 SOC:5500,63084,5541,114800,96,85,92,89 06628 12/10/2025 21:58:55 Discharge level 006 AH, SOC: 90%, I: 49A, L:3910, l:4018, H:3941, B:031, PT:019C, BT:020C, PV:110026, M:Bike On 06629 12/10/2025 21:58:55 SOC:6611,61996,6666,114800,95,89,90,102 06630 12/10/2025 21:59:55 Discharge level 007 AH, SOC: 88%, I: 60A, L:3827, l:3943, H:3871, B:044, PT:019C, BT:020C, PV:107909, M:Bike On 06631 12/10/2025 21:59:55 SOC:7750,61053,7804,114800,94,83,88,115 06632 12/10/2025 22:00:55 Discharge level 009 AH, SOC: 86%, I: 81A, L:3775, l:3911, H:3826, B:051, PT:019C, BT:019C, PV:106567, M:Bike On 06633 12/10/2025 22:00:55 SOC:9016,60146,9077,114800,93,79,86,134 06634 12/10/2025 22:01:55 Discharge level 010 AH, SOC: 84%, I: 0A, L:3858, l:3957, H:3895, B:037, PT:020C, BT:020C, PV:108695, M:Bike On 06635 12/10/2025 22:01:55 SOC:10037,59585,10113,114800,92,84,84,96 06636 12/10/2025 22:02:55 Discharge level 012 AH, SOC: 80%, I:233A, L:3452, l:3775, H:3553, B:101, PT:021C, BT:020C, PV: 98437, M:Bike On 06637 12/10/2025 22:02:55 SOC:11983,58189,12070,114800,90,64,80,330 06638 12/10/2025 22:02:55 Discharge cutback 69% 06639 12/10/2025 22:02:55 590A 06640 12/10/2025 22:03:55 Discharge level 014 AH, SOC: 75%, I:177A, L:3518, l:3803, H:3609, B:091, PT:022C, BT:021C, PV:100185, M:Bike On 06641 12/10/2025 22:03:55 SOC:14733,56954,14831,114800,88,67,75,309 06642 12/10/2025 22:03:55 Discharge cutback 80% 06643 12/10/2025 22:03:55 685A 06644 12/10/2025 22:04:55 Discharge level 017 AH, SOC: 70%, I:136A, L:3573, l:3798, H:3653, B:080, PT:023C, BT:020C, PV:101575, M:Bike On 06645 12/10/2025 22:04:55 SOC:17435,56254,17536,114800,85,68,70,262 06646 12/10/2025 22:05:55 Discharge level 019 AH, SOC: 67%, I: 2A, L:3744, l:3870, H:3787, B:043, PT:024C, BT:020C, PV:105701, M:Bike On 06647 12/10/2025 22:05:55 SOC:18990,56438,19119,114800,84,76,67,150 06648 12/10/2025 22:05:55 Discharge cutback 86% 06649 12/10/2025 22:05:55 742A 06650 12/10/2025 22:06:55 Discharge level 020 AH, SOC: 65%, I:107A, L:3636, l:3798, H:3704, B:068, PT:025C, BT:021C, PV:103168, M:Bike On 06651 12/10/2025 22:06:55 SOC:20168,57065,20353,114800,83,68,65,194 06652 12/10/2025 22:07:55 Discharge level 022 AH, SOC: 62%, I:109A, L:3610, l:3779, H:3681, B:071, PT:026C, BT:021C, PV:102493, M:Bike On 06653 12/10/2025 22:07:55 SOC:21904,57551,22111,114800,81,65,62,210 06654 12/10/2025 22:08:55 Discharge level 024 AH, SOC: 59%, I: 2A, L:3699, l:3822, H:3742, B:043, PT:026C, BT:021C, PV:104477, M:Bike On 06655 12/10/2025 22:08:55 SOC:24017,57864,24240,114800,79,71,59,161 06656 12/10/2025 22:08:55 Discharge cutback 81% 06657 12/10/2025 22:08:55 698A 06658 12/10/2025 22:09:55 Discharge level 026 AH, SOC: 55%, I:201A, L:3446, l:3678, H:3551, B:105, PT:027C, BT:022C, PV: 98603, M:Bike On 06659 12/10/2025 22:09:55 SOC:26223,58111,26476,114800,77,51,55,307 06660 12/10/2025 22:09:55 Discharge cutback 80% 06661 12/10/2025 22:09:55 692A 06662 12/10/2025 22:10:55 Discharge level 028 AH, SOC: 51%, I:126A, L:3520, l:3694, H:3601, B:081, PT:028C, BT:022C, PV:100217, M:Bike On 06663 12/10/2025 22:10:55 SOC:28668,58410,28925,114800,75,55,51,245 06664 12/10/2025 22:10:55 Discharge cutback 80% 06665 12/10/2025 22:10:55 688A 06666 12/10/2025 22:11:55 Discharge level 030 AH, SOC: 48%, I:143A, L:3485, l:3671, H:3573, B:088, PT:029C, BT:021C, PV: 99391, M:Bike On 06667 12/10/2025 22:11:55 SOC:30715,59014,30995,114800,74,51,48,264 06668 12/10/2025 22:11:55 Discharge cutback 75% 06669 12/10/2025 22:11:55 648A 06670 12/10/2025 22:12:55 Discharge level 033 AH, SOC: 45%, I: 0A, L:3621, l:3728, H:3668, B:047, PT:029C, BT:023C, PV:102373, M:Bike On 06671 12/10/2025 22:12:55 SOC:32886,59503,33190,114800,72,60,45,160 06672 12/10/2025 22:12:55 Discharge cutback 75% 06673 12/10/2025 22:12:55 641A 06674 12/10/2025 22:13:55 Discharge level 035 AH, SOC: 43%, I:116A, L:3497, l:3651, H:3576, B:079, PT:030C, BT:022C, PV: 99562, M:Bike On 06675 12/10/2025 22:13:55 SOC:34765,60382,35090,114800,70,47,43,230 06676 12/10/2025 22:13:55 Discharge cutback 74% 06677 12/10/2025 22:13:55 634A 06678 12/10/2025 22:14:55 Discharge level 037 AH, SOC: 40%, I: 0A, L:3604, l:3697, H:3648, B:044, PT:030C, BT:023C, PV:101836, M:Bike On 06679 12/10/2025 22:14:55 SOC:36857,60819,37226,114800,68,56,40,145 06680 12/10/2025 22:14:55 Discharge cutback 69% 06681 12/10/2025 22:14:55 597A 06682 12/10/2025 22:15:55 Discharge level 037 AH, SOC: 41%, I: 58A, L:3587, l:3666, H:3638, B:051, PT:031C, BT:023C, PV:101515, M:Bike On 06683 12/10/2025 22:15:55 SOC:36916,61537,37875,114800,68,51,41,123 06684 12/10/2025 22:15:55 Discharge cutback 83% 06685 06/30/1993 17:53:31 44,8 06686 12/10/2025 22:19:55 Discharge level 039 AH, SOC: 45%, I: 43A, L:3630, l:3667, H:3664, B:034, PT:031C, BT:023C, PV:102370, M:Bike On 06687 12/10/2025 22:19:55 SOC:37061,66204,39560,114800,66,52,45,61 06688 12/10/2025 22:20:55 Discharge level 039 AH, SOC: 46%, I: 1A, L:3676, l:3689, H:3697, B:021, PT:031C, BT:023C, PV:103390, M:Bike On 06689 12/10/2025 22:20:55 SOC:36922,67410,39694,114800,66,56,46,22 06690 12/10/2025 22:21:55 Discharge level 039 AH, SOC: 47%, I: 1A, L:3684, l:3693, H:3702, B:018, PT:031C, BT:024C, PV:103533, M:Bike On 06691 12/10/2025 22:21:55 SOC:36708,68667,39709,114800,66,56,47,15 06692 12/10/2025 22:22:55 Discharge level 039 AH, SOC: 48%, I: 0A, L:3687, l:3694, H:3704, B:017, PT:031C, BT:025C, PV:103615, M:Bike On 06693 12/10/2025 22:22:55 SOC:36241,69067,39713,114800,66,56,48,11 06694 12/10/2025 22:23:55 Discharge level 039 AH, SOC: 49%, I: 0A, L:3690, l:3695, H:3705, B:015, PT:031C, BT:023C, PV:103661, M:Bike On 06695 12/10/2025 22:23:55 SOC:35835,69469,39717,114800,66,56,49,8 06696 12/10/2025 22:24:55 Discharge level 039 AH, SOC: 50%, I: 0A, L:3692, l:3696, H:3707, B:015, PT:031C, BT:025C, PV:103709, M:Bike On 06697 12/10/2025 22:24:55 SOC:35467,69902,39722,114800,66,57,50,6 06698 12/10/2025 22:25:16 Contactor was Opened Pack V: 103710mV, Switched V: 103699mV, Prechg Pct: 100%, Dischg Cur: 818mA 06699 12/10/2025 22:25:17 System Turned Off 06700 12/10/2025 22:25:18 DEBUG: CAN Link Is Down 06701 12/10/2025 22:25:18 DEBUG: Entered Idle State 06702 12/10/2025 22:25:24 Current Sensor Zeroed old: 2510mV, new: 2504mV, corrfact: 252 06703 12/10/2025 22:25:24 Current Sensor Zeroed old: 2506mV, new: 2503mV, corrfact: 253 06704 12/10/2025 22:25:25 Discharge level 039 AH, SOC: 50%, I: 0A, L:3693, l:3696, H:3708, B:015, PT:031C, BT:025C, PV:103742, M:Idle 06705 12/10/2025 22:25:25 SOC:35332,70060,39724,114800,66,57,50,5 06706 12/10/2025 22:25:46 Voltage Across Contactor: 90642mV (Okay) 06707 12/10/2025 22:29:52 System Turned On 06708 12/10/2025 22:29:52 Rev:45,Build:2023-05-20_045619 958 banka 06709 12/10/2025 22:29:52 Pack:2019_monolith,Numbricks:4 06710 12/10/2025 22:29:52 DEBUG: Entered Running State 06711 12/10/2025 22:29:52 DEBUG: CAN NOT Receiving Syncs 06712 12/10/2025 22:29:52 DEBUG: CAN Link Is Up 06713 12/10/2025 22:29:53 DEBUG: Resetting CAN0 due to error passive mode 06714 12/10/2025 22:29:53 Discharge level 039 AH, SOC: 50%, I: 0A, L:3699, l:3702, H:3712, B:013, PT:031C, BT:025C, PV:103853, M:Bike On 06715 12/10/2025 22:29:53 SOC:35326,70060,39724,114800,66,57,50,6 06716 12/10/2025 22:29:56 DEBUG: CAN Receiving Syncs 06717 12/10/2025 22:29:57 Contactor drive turned on Pack V: 103851mV, Switched V: 91057mV, Duty Cycle: 38% 06718 12/10/2025 22:29:57 Contactor was Closed Pack V: 103851mV, Switched V: 91057mV, Prechg Pct: 88%, Dischg Cur: 545mA 06719 12/10/2025 22:29:59 DEBUG: Entered Charging State 06720 12/10/2025 22:29:59 DEBUG: CAN NOT Receiving Syncs 06721 12/10/2025 22:30:00 Discharge level 039 AH, SOC: 50%, I: 0A, L:3699, l:3702, H:3712, B:013, PT:031C, BT:025C, PV:103850, M:Charge 06722 12/10/2025 22:30:00 SOC:35283,70066,39724,114800,66,57,50,6 06723 12/10/2025 22:30:00 DEBUG: CAN Receiving Syncs 06724 12/10/2025 22:40:00 Discharge level 037 AH, SOC: 60%, I:-11A, L:3747, l:3734, H:3753, B:006, PT:030C, BT:034C, PV:105040, M:Charge 06725 12/10/2025 22:40:00 SOC:25243,62022,37799,114800,68,62,60,-21 06726 12/10/2025 22:50:00 Discharge level 035 AH, SOC: 65%, I:-11A, L:3772, l:3757, H:3775, B:003, PT:030C, BT:038C, PV:105666, M:Charge 06727 12/10/2025 22:50:00 SOC:21549,60260,35884,114800,69,65,65,-21 06728 12/10/2025 23:00:00 Discharge level 033 AH, SOC: 68%, I:-11A, L:3793, l:3778, H:3798, B:005, PT:030C, BT:039C, PV:106278, M:Charge 06729 12/10/2025 23:00:00 SOC:19877,60524,33963,114800,71,67,68,-21 06730 12/10/2025 23:10:08 Discharge level 032 AH, SOC: 70%, I:-11A, L:3815, l:3800, H:3821, B:006, PT:030C, BT:040C, PV:106895, M:Charge 06731 12/10/2025 23:10:08 SOC:18599,61202,32024,114800,73,69,70,-21 06732 12/10/2025 23:20:08 Discharge level 030 AH, SOC: 72%, I:-11A, L:3838, l:3823, H:3845, B:007, PT:029C, BT:040C, PV:107556, M:Charge 06733 12/10/2025 23:20:08 SOC:17422,61953,30112,114800,74,72,72,-21 06734 12/10/2025 23:30:08 Discharge level 028 AH, SOC: 75%, I:-11A, L:3862, l:3847, H:3868, B:006, PT:029C, BT:040C, PV:108221, M:Charge 06735 12/10/2025 23:30:08 SOC:16034,62461,28233,114800,76,74,75,-21 06736 12/10/2025 23:40:08 Discharge level 026 AH, SOC: 77%, I:-11A, L:3886, l:3871, H:3891, B:005, PT:029C, BT:042C, PV:108889, M:Charge 06737 12/10/2025 23:40:08 SOC:14702,63013,26366,114800,78,76,77,-21 06738 12/10/2025 23:50:08 Discharge level 024 AH, SOC: 79%, I:-10A, L:3907, l:3892, H:3913, B:006, PT:029C, BT:042C, PV:109526, M:Charge 06739 12/10/2025 23:50:08 SOC:13496,63678,24513,114800,79,78,79,-20 06740 12/11/2025 00:00:08 Discharge level 022 AH, SOC: 81%, I:-10A, L:3928, l:3914, H:3935, B:007, PT:029C, BT:043C, PV:110119, M:Charge 06741 12/11/2025 00:00:08 SOC:12346,64370,22686,114800,81,80,81,-20 06742 12/11/2025 00:10:08 Discharge level 020 AH, SOC: 83%, I:-11A, L:3948, l:3933, H:3955, B:007, PT:028C, BT:044C, PV:110675, M:Charge 06743 12/11/2025 00:10:08 SOC:11343,65201,20870,114800,82,82,83,-20 06744 12/11/2025 00:20:16 Discharge level 019 AH, SOC: 85%, I:-10A, L:3969, l:3954, H:3975, B:006, PT:028C, BT:044C, PV:111256, M:Charge 06745 12/11/2025 00:20:16 SOC:10198,65941,19002,114800,84,84,85,-21 06746 12/11/2025 00:30:16 Discharge level 017 AH, SOC: 87%, I:-10A, L:3989, l:3975, H:3994, B:005, PT:028C, BT:043C, PV:111788, M:Charge 06747 12/11/2025 00:30:16 SOC:9111,66703,17169,114800,86,86,87,-20 06748 12/11/2025 00:40:16 Discharge level 015 AH, SOC: 89%, I:-11A, L:4008, l:3993, H:4013, B:005, PT:028C, BT:042C, PV:112318, M:Charge 06749 12/11/2025 00:40:16 SOC:8061,67477,15363,114800,87,88,89,-20 06750 12/11/2025 00:49:27 Charged To Full 013 AH, SOC: 90%, L:4026, H:4031, B:005, PT:027C, BT:042C, PV:112748 06751 12/11/2025 00:49:27 SOC adjusted for voltage old: 7056614uAH (soc:90%), new: 6132423uAH (soc:91%), low cell: 4026 mV 06752 12/11/2025 00:50:16 Discharge level 010 AH, SOC: 91%, I:-10A, L:4028, l:4014, H:4032, B:004, PT:027C, BT:043C, PV:112855, M:Charge 06753 12/11/2025 00:50:16 SOC:6242,68395,10186,114800,92,90,91,-20 06754 12/11/2025 01:00:16 Discharge level 008 AH, SOC: 92%, I:-10A, L:4047, l:4033, H:4051, B:004, PT:027C, BT:043C, PV:113395, M:Charge 06755 12/11/2025 01:00:16 SOC:5800,69741,8416,114800,93,91,92,-20 06756 12/11/2025 01:10:16 Discharge level 006 AH, SOC: 94%, I:-10A, L:4067, l:4054, H:4070, B:003, PT:027C, BT:040C, PV:113931, M:Charge 06757 12/11/2025 01:10:16 SOC:4549,70256,6668,114800,95,93,94,-19 06758 12/11/2025 01:20:16 Discharge level 004 AH, SOC: 96%, I:-10A, L:4088, l:4074, H:4090, B:002, PT:027C, BT:034C, PV:114490, M:Charge 06759 12/11/2025 01:20:16 SOC:3233,70697,4927,114800,96,95,96,-20 06760 12/11/2025 02:05:16 DEBUG: CAN Link Is Down 06761 12/11/2025 02:05:20 Contactor was Opened Pack V: 116070mV, Switched V: 116066mV, Prechg Pct: 100%, Dischg Cur: 545mA 06762 12/11/2025 02:05:20 DEBUG: CAN Link Is Up 06763 12/11/2025 02:05:22 System Turned Off 06764 12/11/2025 02:05:23 DEBUG: CAN Link Is Down 06765 12/11/2025 02:05:23 DEBUG: Entered Idle State 06766 12/11/2025 02:05:29 Current Sensor Zeroed old: 2503mV, new: 2504mV, corrfact: 252 06767 12/11/2025 02:05:30 Discharge level 000 AH, SOC:100%, I: 0A, L:4147, l:4145, H:4150, B:003, PT:026C, BT:034C, PV:116164, M:Idle 06768 12/11/2025 02:05:30 SOC:0,71612,0,114800,100,100,100,-4 06769 12/11/2025 02:05:50 Voltage Across Contactor: 103296mV (Okay) 06770 12/11/2025 08:54:12 System Turned On 06771 12/11/2025 08:54:12 Rev:45,Build:2023-05-20_045619 958 banka 06772 12/11/2025 08:54:12 Pack:2019_monolith,Numbricks:4 06773 12/11/2025 08:54:12 DEBUG: Entered Charging State 06774 12/11/2025 08:54:12 DEBUG: CAN NOT Receiving Syncs 06775 12/11/2025 08:54:12 DEBUG: Entered Running State 06776 12/11/2025 08:54:12 DEBUG: CAN Link Is Up 06777 12/11/2025 08:54:13 DEBUG: Resetting CAN0 due to error passive mode 06778 12/11/2025 08:54:13 Discharge level 000 AH, SOC:100%, I: 0A, L:4121, l:4118, H:4129, B:008, PT:019C, BT:024C, PV:115522, M:Bike On 06779 12/11/2025 08:54:13 SOC:0,71612,0,114800,100,99,100,-3 06780 12/11/2025 08:54:16 DEBUG: CAN Receiving Syncs 06781 12/11/2025 08:54:21 Contactor drive turned on Pack V: 115510mV, Switched V: 102321mV, Duty Cycle: 34% 06782 12/11/2025 08:54:21 Contactor was Closed Pack V: 115510mV, Switched V: 102321mV, Prechg Pct: 89%, Dischg Cur: 363mA 06783 12/11/2025 08:55:13 Discharge level 000 AH, SOC:100%, I: 0A, L:4120, l:4120, H:4128, B:008, PT:019C, BT:023C, PV:115501, M:Bike On 06784 12/11/2025 08:55:13 SOC:10,71611,0,114800,100,100,100,0 06785 12/11/2025 08:56:13 Discharge level 000 AH, SOC:100%, I: 22A, L:4080, l:4096, H:4092, B:012, PT:019C, BT:024C, PV:114407, M:Bike On 06786 12/11/2025 08:56:13 SOC:64,71500,52,114800,100,97,100,18 06787 12/11/2025 08:57:13 Discharge level 000 AH, SOC:100%, I:121A, L:3878, l:3966, H:3917, B:039, PT:019C, BT:024C, PV:109147, M:Bike On 06788 12/11/2025 08:57:13 SOC:360,70948,350,114800,100,85,100,96 06789 12/11/2025 08:58:13 Discharge level 000 AH, SOC: 99%, I: 1A, L:4093, l:4107, H:4104, B:011, PT:019C, BT:024C, PV:114791, M:Bike On 06790 12/11/2025 08:58:13 SOC:703,70326,690,114800,100,98,99,15 06791 12/11/2025 08:59:13 Discharge level 000 AH, SOC: 99%, I: 1A, L:4105, l:4109, H:4114, B:009, PT:019C, BT:024C, PV:115101, M:Bike On 06792 12/11/2025 08:59:13 SOC:723,70114,724,114800,100,98,99,5 06793 12/11/2025 09:00:13 Discharge level 000 AH, SOC: 99%, I: 1A, L:4102, l:4107, H:4112, B:010, PT:019C, BT:024C, PV:115011, M:Bike On 06794 12/11/2025 09:00:13 SOC:711,69928,737,114800,100,98,99,5 06795 12/11/2025 09:01:13 Discharge level 001 AH, SOC: 99%, I:138A, L:3866, l:3972, H:3907, B:041, PT:019C, BT:024C, PV:108865, M:Bike On 06796 12/11/2025 09:01:13 SOC:1123,69274,1168,114800,99,85,99,115 06797 12/11/2025 09:02:13 Discharge level 001 AH, SOC: 98%, I: 1A, L:4051, l:4083, H:4065, B:014, PT:020C, BT:024C, PV:113650, M:Bike On 06798 12/11/2025 09:02:13 SOC:1664,68436,1708,114800,99,96,98,37 06799 12/11/2025 09:03:13 Discharge level 002 AH, SOC: 98%, I: 8A, L:4051, l:4074, H:4066, B:015, PT:020C, BT:023C, PV:113690, M:Bike On 06800 12/11/2025 09:03:13 SOC:1990,67896,2019,114800,99,95,98,26 06801 12/11/2025 09:03:35 Contactor was Opened Pack V: 114274mV, Switched V: 114254mV, Prechg Pct: 100%, Dischg Cur: 909mA 06802 12/11/2025 09:03:36 System Turned Off 06803 12/11/2025 09:03:36 DEBUG: CAN Link Is Down 06804 12/11/2025 09:03:37 DEBUG: Entered Idle State 06805 12/11/2025 09:03:42 Current Sensor Zeroed old: 2504mV, new: 2506mV, corrfact: 250 06806 12/11/2025 09:03:43 SOC adjusted for voltage old: 1998659uAH (soc:98%), new: 3391230uAH (soc:95%), low cell: 4076 mV 06807 12/11/2025 09:03:44 Discharge level 005 AH, SOC: 95%, I: 0A, L:4076, l:4087, H:4088, B:012, PT:020C, BT:024C, PV:114352, M:Idle 06808 12/11/2025 09:03:44 SOC:3391,67824,5740,114800,95,96,95,13 06809 12/11/2025 09:04:05 Voltage Across Contactor: 101350mV (Okay) 06810 12/11/2025 09:06:24 System Turned On 06811 12/11/2025 09:06:24 Rev:45,Build:2023-05-20_045619 958 banka 06812 12/11/2025 09:06:24 Pack:2019_monolith,Numbricks:4 06813 12/11/2025 09:06:24 DEBUG: Entered Running State 06814 12/11/2025 09:06:24 DEBUG: CAN NOT Receiving Syncs 06815 12/11/2025 09:06:24 DEBUG: CAN Link Is Up 06816 12/11/2025 09:06:25 DEBUG: Resetting CAN0 due to error passive mode 06817 12/11/2025 09:06:25 Discharge level 005 AH, SOC: 98%, I: 0A, L:4088, l:4100, H:4097, B:009, PT:020C, BT:024C, PV:114620, M:Bike On 06818 12/11/2025 09:06:25 SOC:1998,67824,5740,114800,95,97,98,13 06819 12/11/2025 09:06:28 DEBUG: CAN Receiving Syncs 06820 12/11/2025 09:06:29 Contactor drive turned on Pack V: 114593mV, Switched V: 100548mV, Duty Cycle: 35% 06821 12/11/2025 09:06:29 Contactor was Closed Pack V: 114593mV, Switched V: 100548mV, Prechg Pct: 88%, Dischg Cur: 636mA 06822 12/11/2025 09:07:25 Discharge level 005 AH, SOC: 98%, I: 0A, L:4088, l:4095, H:4097, B:009, PT:020C, BT:023C, PV:114622, M:Bike On 06823 12/11/2025 09:07:25 SOC:2002,67824,5740,114800,95,97,98,7 06824 12/11/2025 09:08:25 Discharge level 005 AH, SOC: 97%, I: 6A, L:4074, l:4086, H:4084, B:010, PT:020C, BT:023C, PV:114254, M:Bike On 06825 12/11/2025 09:08:25 SOC:2159,67585,5898,114800,95,96,97,13 06826 12/11/2025 09:09:25 Discharge level 006 AH, SOC: 97%, I: 0A, L:4076, l:4087, H:4087, B:011, PT:020C, BT:024C, PV:114310, M:Bike On 06827 12/11/2025 09:09:25 SOC:2344,67207,6105,114800,95,96,97,12 06828 12/11/2025 09:10:25 Discharge level 006 AH, SOC: 97%, I: 33A, L:4004, l:4036, H:4025, B:021, PT:020C, BT:023C, PV:112448, M:Bike On 06829 12/11/2025 09:10:25 SOC:2483,66883,6267,114800,95,91,97,35 06830 12/11/2025 09:11:25 Discharge level 006 AH, SOC: 96%, I: 1A, L:4067, l:4079, H:4078, B:011, PT:020C, BT:024C, PV:114070, M:Bike On 06831 12/11/2025 09:11:25 SOC:2729,66495,6526,114800,95,96,96,14 06832 12/11/2025 09:12:25 Discharge level 006 AH, SOC: 96%, I: 10A, L:4049, l:4064, H:4063, B:014, PT:020C, BT:023C, PV:113599, M:Bike On 06833 12/11/2025 09:12:25 SOC:2846,66230,6650,114800,95,94,96,16 06834 12/11/2025 09:13:25 Discharge level 006 AH, SOC: 96%, I: 0A, L:4063, l:4076, H:4076, B:013, PT:020C, BT:024C, PV:113984, M:Bike On 06835 12/11/2025 09:13:25 SOC:3011,65977,6808,114800,95,95,96,14 06836 12/11/2025 09:14:25 Discharge level 006 AH, SOC: 96%, I: 1A, L:4069, l:4076, H:4080, B:011, PT:020C, BT:023C, PV:114130, M:Bike On 06837 12/11/2025 09:14:25 SOC:3067,65691,6914,114800,94,95,96,8 06838 12/11/2025 09:15:25 Discharge level 006 AH, SOC: 96%, I: 0A, L:4070, l:4075, H:4080, B:010, PT:020C, BT:023C, PV:114133, M:Bike On 06839 12/11/2025 09:15:25 SOC:3106,65662,6935,114800,94,95,96,5 06840 12/11/2025 09:16:25 Discharge level 006 AH, SOC: 96%, I: 0A, L:4071, l:4074, H:4083, B:012, PT:020C, BT:024C, PV:114180, M:Bike On 06841 12/11/2025 09:16:25 SOC:3121,65662,6935,114800,94,95,96,3 06842 12/11/2025 09:17:25 Discharge level 007 AH, SOC: 95%, I: -9A, L:4071, l:4095, H:4079, B:008, PT:020C, BT:024C, PV:114144, M:Bike On 06843 12/11/2025 09:17:25 SOC:3519,65075,7378,114800,94,97,95,26 06844 12/11/2025 09:18:25 Discharge level 007 AH, SOC: 95%, I: 0A, L:4044, l:4062, H:4057, B:013, PT:020C, BT:022C, PV:113472, M:Bike On 06845 12/11/2025 09:18:25 SOC:3874,64613,7741,114800,94,94,95,20 06846 12/11/2025 09:18:54 Contactor was Opened Pack V: 113644mV, Switched V: 113585mV, Prechg Pct: 100%, Dischg Cur: 727mA 06847 12/11/2025 09:18:55 System Turned Off 06848 12/11/2025 09:18:55 DEBUG: CAN Link Is Down 06849 12/11/2025 09:18:55 DEBUG: Entered Idle State 06850 12/11/2025 09:19:01 Current Sensor Zeroed old: 2506mV, new: 2505mV, corrfact: 251 06851 12/11/2025 09:19:02 SOC adjusted for voltage old: 3875987uAH (soc:95%), new: 4522926uAH (soc:93%), low cell: 4053 mV 06852 12/11/2025 09:19:03 Discharge level 008 AH, SOC: 93%, I: 0A, L:4053, l:4063, H:4065, B:012, PT:020C, BT:024C, PV:113706, M:Idle 06853 12/11/2025 09:19:03 SOC:4522,64613,8036,114800,93,94,93,11 06854 12/11/2025 09:19:24 Voltage Across Contactor: 100619mV (Okay) 06855 12/11/2025 09:28:58 System Turned On 06856 12/11/2025 09:28:58 Rev:45,Build:2023-05-20_045619 958 banka 06857 12/11/2025 09:28:58 Pack:2019_monolith,Numbricks:4 06858 12/11/2025 09:28:59 DEBUG: Entered Running State 06859 12/11/2025 09:28:59 DEBUG: CAN NOT Receiving Syncs 06860 12/11/2025 09:28:59 DEBUG: CAN Link Is Up 06861 12/11/2025 09:28:59 DEBUG: Resetting CAN0 due to error passive mode 06862 12/11/2025 09:29:00 Discharge level 008 AH, SOC: 95%, I: 0A, L:4067, l:4077, H:4077, B:010, PT:020C, BT:023C, PV:114059, M:Bike On 06863 12/11/2025 09:29:00 SOC:3875,64613,8036,114800,93,95,95,11 06864 12/11/2025 09:29:03 DEBUG: CAN Receiving Syncs 06865 12/11/2025 09:29:08 Contactor drive turned on Pack V: 114038mV, Switched V: 101257mV, Duty Cycle: 35% 06866 12/11/2025 09:29:08 Contactor was Closed Pack V: 114038mV, Switched V: 101257mV, Prechg Pct: 89%, Dischg Cur: 454mA 06867 12/11/2025 09:30:00 Discharge level 008 AH, SOC: 95%, I: 1A, L:4067, l:4073, H:4077, B:010, PT:020C, BT:023C, PV:114040, M:Bike On 06868 12/11/2025 09:30:00 SOC:3846,64688,8043,114800,93,95,95,6 06869 12/11/2025 09:31:00 Discharge level 008 AH, SOC: 95%, I: 1A, L:4052, l:4059, H:4064, B:012, PT:020C, BT:022C, PV:113672, M:Bike On 06870 12/11/2025 09:31:00 SOC:3876,64738,8092,114800,93,94,95,8 06871 12/11/2025 09:32:00 Discharge level 008 AH, SOC: 94%, I: -7A, L:4052, l:4072, H:4063, B:011, PT:020C, BT:022C, PV:113653, M:Bike On 06872 12/11/2025 09:32:00 SOC:4407,64078,8677,114800,93,95,94,21 06873 12/11/2025 09:33:00 Discharge level 008 AH, SOC: 93%, I: 1A, L:4042, l:4054, H:4056, B:014, PT:020C, BT:023C, PV:113411, M:Bike On 06874 12/11/2025 09:33:00 SOC:4492,63994,8768,114800,93,93,93,13 06875 12/11/2025 09:34:00 Discharge level 009 AH, SOC: 93%, I: 9A, L:4028, l:4048, H:4043, B:015, PT:020C, BT:021C, PV:113064, M:Bike On 06876 12/11/2025 09:34:00 SOC:4757,63701,9051,114800,93,92,93,21 06877 12/11/2025 09:35:00 Discharge level 009 AH, SOC: 92%, I:117A, L:3843, l:3938, H:3884, B:041, PT:020C, BT:023C, PV:108238, M:Bike On 06878 12/11/2025 09:35:00 SOC:5355,62882,9769,114800,92,82,92,109 06879 12/11/2025 09:36:00 Discharge level 010 AH, SOC: 91%, I: 1A, L:4017, l:4036, H:4031, B:014, PT:020C, BT:023C, PV:112733, M:Bike On 06880 12/11/2025 09:36:00 SOC:5639,62354,10156,114800,92,91,91,22 06881 12/11/2025 09:37:00 Discharge level 010 AH, SOC: 90%, I: 43A, L:3946, l:4015, H:3969, B:023, PT:020C, BT:023C, PV:110869, M:Bike On 06882 12/11/2025 09:37:00 SOC:6375,61644,10926,114800,91,90,90,79 06883 12/11/2025 09:38:00 Discharge level 011 AH, SOC: 89%, I: 30A, L:3968, l:4008, H:3989, B:021, PT:020C, BT:023C, PV:111466, M:Bike On 06884 12/11/2025 09:38:00 SOC:6747,61325,11334,114800,91,89,89,46 06885 12/11/2025 09:39:00 Discharge level 011 AH, SOC: 89%, I: 94A, L:3844, l:3922, H:3883, B:039, PT:021C, BT:023C, PV:108237, M:Bike On 06886 12/11/2025 09:39:00 SOC:7099,60998,11749,114800,90,81,89,89 06887 12/11/2025 09:40:00 Discharge level 011 AH, SOC: 89%, I: 0A, L:4001, l:4015, H:4015, B:014, PT:021C, BT:023C, PV:112298, M:Bike On 06888 12/11/2025 09:40:00 SOC:7191,60887,11909,114800,90,90,89,16 06889 12/11/2025 09:41:00 Discharge level 011 AH, SOC: 89%, I: 0A, L:4008, l:4016, H:4022, B:014, PT:021C, BT:023C, PV:112481, M:Bike On 06890 12/11/2025 09:41:00 SOC:7130,60949,11918,114800,90,90,89,9 06891 12/11/2025 09:41:03 Contactor was Opened Pack V: 112491mV, Switched V: 112443mV, Prechg Pct: 100%, Dischg Cur: 727mA 06892 12/11/2025 09:41:04 System Turned Off 06893 12/11/2025 09:41:04 DEBUG: CAN Link Is Down 06894 12/11/2025 09:41:05 DEBUG: Entered Idle State 06895 12/11/2025 09:41:10 Current Sensor Zeroed old: 2505mV, new: 2504mV, corrfact: 252 06896 12/11/2025 09:41:12 Discharge level 011 AH, SOC: 89%, I: 0A, L:4011, l:4018, H:4024, B:013, PT:021C, BT:023C, PV:112537, M:Idle 06897 12/11/2025 09:41:12 SOC:7122,60949,11918,114800,90,90,89,8 06898 12/11/2025 09:41:18 System Turned On 06899 12/11/2025 09:41:18 Rev:45,Build:2023-05-20_045619 958 banka 06900 12/11/2025 09:41:18 Pack:2019_monolith,Numbricks:4 06901 12/11/2025 09:41:18 DEBUG: Entered Running State 06902 12/11/2025 09:41:18 DEBUG: CAN NOT Receiving Syncs 06903 12/11/2025 09:41:19 DEBUG: CAN Link Is Up 06904 12/11/2025 09:41:19 DEBUG: Resetting CAN0 due to error passive mode 06905 12/11/2025 09:41:19 Discharge level 011 AH, SOC: 89%, I: 0A, L:4010, l:4017, H:4023, B:013, PT:021C, BT:022C, PV:112531, M:Bike On 06906 12/11/2025 09:41:19 SOC:7121,60949,11918,114800,90,90,89,9 06907 12/11/2025 09:41:22 DEBUG: CAN Receiving Syncs 06908 12/11/2025 09:41:23 Contactor drive turned on Pack V: 112523mV, Switched V: 99328mV, Duty Cycle: 35% 06909 12/11/2025 09:41:23 Contactor was Closed Pack V: 112523mV, Switched V: 99328mV, Prechg Pct: 88%, Dischg Cur: 545mA 06910 12/11/2025 09:41:32 DEBUG: Entered Charging State 06911 12/11/2025 09:41:32 DEBUG: CAN NOT Receiving Syncs 06912 12/11/2025 09:41:33 Discharge level 011 AH, SOC: 89%, I: 0A, L:4011, l:4018, H:4024, B:013, PT:021C, BT:024C, PV:112546, M:Charge 06913 12/11/2025 09:41:33 SOC:7101,60950,11918,114800,90,90,89,8 06914 12/11/2025 09:41:33 DEBUG: CAN Receiving Syncs 06915 12/11/2025 09:41:42 Charged To Full 011 AH, SOC: 89%, L:4032, H:4042, B:010, PT:021C, BT:024C, PV:113093 06916 12/11/2025 09:41:42 SOC adjusted for voltage old: 7079165uAH (soc:89%), new: 5485066uAH (soc:91%), low cell: 4032 mV 06917 12/11/2025 09:51:33 Discharge level 008 AH, SOC: 95%, I:-10A, L:4081, l:4065, H:4087, B:006, PT:021C, BT:033C, PV:114371, M:Charge 06918 12/11/2025 09:51:33 SOC:3493,60689,8614,114800,93,94,95,-18 06919 12/11/2025 10:01:33 Discharge level 006 AH, SOC: 97%, I:-10A, L:4107, l:4091, H:4112, B:005, PT:021C, BT:037C, PV:115086, M:Charge 06920 12/11/2025 10:01:33 SOC:1921,60864,6885,114800,95,97,97,-19 06921 12/11/2025 10:11:33 Discharge level 005 AH, SOC:100%, I:-10A, L:4131, l:4115, H:4136, B:005, PT:021C, BT:039C, PV:115758, M:Charge 06922 12/11/2025 10:11:33 SOC:476,61127,5195,114800,96,99,100,-19 06923 12/11/2025 10:21:41 Discharge level 003 AH, SOC:100%, I: -9A, L:4154, l:4139, H:4159, B:005, PT:021C, BT:040C, PV:116386, M:Charge 06924 12/11/2025 10:21:41 SOC:0,61151,3513,114800,97,100,100,-18 06925 12/11/2025 10:31:52 DEBUG: CAN Link Is Down 06926 12/11/2025 10:31:57 Contactor was Opened Pack V: 115944mV, Switched V: 116027mV, Prechg Pct: 100%, Dischg Cur: 363mA 06927 12/11/2025 10:31:57 DEBUG: CAN Link Is Up 06928 12/11/2025 10:31:59 System Turned Off 06929 12/11/2025 10:32:00 DEBUG: CAN Link Is Down 06930 12/11/2025 10:32:00 DEBUG: Entered Idle State 06931 12/11/2025 10:32:07 Discharge level 002 AH, SOC:100%, I: 0A, L:4144, l:4140, H:4148, B:004, PT:020C, BT:036C, PV:116095, M:Idle 06932 12/11/2025 10:32:07 SOC:0,61151,2423,114800,98,100,100,-4 06933 12/11/2025 10:32:27 Voltage Across Contactor: 103182mV (Okay) 06934 12/11/2025 11:44:52 System Turned On 06935 12/11/2025 11:44:52 Rev:45,Build:2023-05-20_045619 958 banka 06936 12/11/2025 11:44:52 Pack:2019_monolith,Numbricks:4 06937 12/11/2025 11:44:52 DEBUG: Entered Charging State 06938 12/11/2025 11:44:52 DEBUG: CAN NOT Receiving Syncs 06939 12/11/2025 11:44:53 DEBUG: Entered Running State 06940 12/11/2025 11:44:53 DEBUG: CAN Link Is Up 06941 12/11/2025 11:44:53 DEBUG: Resetting CAN0 due to error passive mode 06942 12/11/2025 11:44:54 Discharge level 002 AH, SOC:100%, I: 0A, L:4127, l:4124, H:4135, B:008, PT:020C, BT:024C, PV:115684, M:Bike On 06943 12/11/2025 11:44:54 SOC:0,61151,2423,114800,98,100,100,-4 06944 12/11/2025 11:44:57 DEBUG: CAN Receiving Syncs 06945 12/11/2025 11:44:57 Contactor drive turned on Pack V: 115648mV, Switched V: 101218mV, Duty Cycle: 34% 06946 12/11/2025 11:44:57 Contactor was Closed Pack V: 115648mV, Switched V: 101218mV, Prechg Pct: 88%, Dischg Cur: 909mA 06947 12/11/2025 11:45:54 Discharge level 002 AH, SOC:100%, I: 1A, L:4125, l:4125, H:4133, B:008, PT:020C, BT:024C, PV:115627, M:Bike On 06948 12/11/2025 11:45:54 SOC:12,61151,2438,114800,98,100,100,0 06949 12/11/2025 11:46:54 Discharge level 002 AH, SOC:100%, I: 1A, L:4125, l:4125, H:4131, B:006, PT:020C, BT:024C, PV:115599, M:Bike On 06950 12/11/2025 11:46:54 SOC:30,61148,2457,114800,98,100,100,0 06951 12/11/2025 11:47:54 Discharge level 002 AH, SOC:100%, I: 41A, L:4049, l:4078, H:4067, B:018, PT:020C, BT:024C, PV:113665, M:Bike On 06952 12/11/2025 11:47:54 SOC:294,60742,2731,114800,98,95,100,34 06953 12/11/2025 11:48:54 Discharge level 003 AH, SOC: 99%, I:-17A, L:4126, l:4132, H:4132, B:006, PT:020C, BT:025C, PV:115625, M:Bike On 06954 12/11/2025 11:48:54 SOC:669,60176,3125,114800,98,100,99,7 06955 12/11/2025 11:49:54 Discharge level 003 AH, SOC: 99%, I: 1A, L:4098, l:4105, H:4108, B:010, PT:020C, BT:024C, PV:114905, M:Bike On 06956 12/11/2025 11:49:54 SOC:686,59978,3187,114800,98,98,99,8 06957 12/11/2025 11:50:54 Discharge level 003 AH, SOC: 99%, I:-17A, L:4133, l:4133, H:4138, B:005, PT:020C, BT:024C, PV:115810, M:Bike On 06958 12/11/2025 11:50:54 SOC:752,59751,3295,114800,98,100,99,0 06959 12/11/2025 11:51:54 Discharge level 004 AH, SOC: 98%, I: 0A, L:4067, l:4103, H:4080, B:013, PT:020C, BT:024C, PV:114086, M:Bike On 06960 12/11/2025 11:51:54 SOC:1493,58824,4066,114800,97,98,98,42 06961 12/11/2025 11:52:54 Discharge level 005 AH, SOC: 96%, I: 92A, L:3843, l:3972, H:3881, B:038, PT:020C, BT:024C, PV:108171, M:Bike On 06962 12/11/2025 11:52:54 SOC:2682,57559,5290,114800,96,85,96,149 06963 12/11/2025 11:53:54 Discharge level 007 AH, SOC: 93%, I: 97A, L:3803, l:3955, H:3845, B:042, PT:021C, BT:024C, PV:107119, M:Bike On 06964 12/11/2025 11:53:54 SOC:4429,56049,7037,114800,94,84,93,175 06965 12/11/2025 11:54:54 Discharge level 008 AH, SOC: 89%, I:102A, L:3775, l:3925, H:3822, B:047, PT:021C, BT:024C, PV:106457, M:Bike On 06966 12/11/2025 11:54:54 SOC:6190,54759,8799,114800,93,81,89,182 06967 12/11/2025 11:55:54 Discharge level 011 AH, SOC: 85%, I:149A, L:3676, l:3877, H:3737, B:061, PT:022C, BT:024C, PV:103942, M:Bike On 06968 12/11/2025 11:55:54 SOC:8521,53486,11131,114800,91,76,85,241 06969 12/11/2025 11:56:54 Discharge level 013 AH, SOC: 79%, I:150A, L:3634, l:3858, H:3702, B:068, PT:023C, BT:023C, PV:102952, M:Bike On 06970 12/11/2025 11:56:54 SOC:11283,52459,13895,114800,88,74,79,272 06971 12/11/2025 11:57:54 Discharge level 016 AH, SOC: 74%, I:399A, L:3322, l:3687, H:3450, B:128, PT:024C, BT:022C, PV: 95293, M:Bike On 06972 12/11/2025 11:57:54 SOC:13979,52032,16596,114800,86,55,74,450 06973 12/11/2025 11:58:54 Discharge level 019 AH, SOC: 68%, I:159A, L:3587, l:3818, H:3665, B:078, PT:025C, BT:024C, PV:101896, M:Bike On 06974 12/11/2025 11:58:54 SOC:16728,52089,19347,114800,84,69,68,285 06975 12/11/2025 11:59:54 Discharge level 021 AH, SOC: 64%, I:134A, L:3610, l:3813, H:3683, B:073, PT:026C, BT:022C, PV:102506, M:Bike On 06976 12/11/2025 11:59:54 SOC:19013,52697,21636,114800,82,70,64,261 06977 12/11/2025 12:00:54 Discharge level 024 AH, SOC: 60%, I:129A, L:3587, l:3782, H:3665, B:078, PT:027C, BT:024C, PV:101989, M:Bike On 06978 12/11/2025 12:00:54 SOC:21474,53403,24099,114800,80,66,60,262 06979 12/11/2025 12:01:54 Discharge level 026 AH, SOC: 56%, I:178A, L:3520, l:3743, H:3609, B:089, PT:028C, BT:024C, PV:100354, M:Bike On 06980 12/11/2025 12:01:54 SOC:24001,53752,26744,114800,77,61,56,317 06981 12/11/2025 12:01:54 Discharge cutback 80% 06982 12/11/2025 12:01:54 692A 06983 12/11/2025 12:02:54 Discharge level 029 AH, SOC: 51%, I:147A, L:3518, l:3714, H:3605, B:087, PT:029C, BT:024C, PV:100276, M:Bike On 06984 12/11/2025 12:02:54 SOC:26900,54445,29645,114800,75,58,51,297 06985 12/11/2025 12:02:54 Discharge cutback 82% 06986 12/11/2025 12:02:54 702A 06987 12/11/2025 12:03:54 Discharge level 031 AH, SOC: 48%, I:193A, L:3492, l:3688, H:3581, B:089, PT:030C, BT:024C, PV: 99582, M:Bike On 06988 12/11/2025 12:03:54 SOC:28972,55176,31909,114800,73,53,48,301 06989 12/11/2025 12:03:54 Discharge cutback 81% 06990 12/11/2025 12:03:54 695A 06991 12/11/2025 12:04:54 Discharge level 035 AH, SOC: 43%, I:231A, L:3417, l:3636, H:3520, B:103, PT:031C, BT:023C, PV: 97789, M:Bike On 06992 12/11/2025 12:04:54 SOC:32075,55671,35033,114800,70,45,43,354 06993 12/11/2025 12:04:54 Discharge cutback 71% 06994 12/11/2025 12:04:54 611A 06995 12/11/2025 12:05:54 Discharge level 037 AH, SOC: 39%, I:218A, L:3400, l:3614, H:3505, B:105, PT:032C, BT:024C, PV: 97387, M:Bike On 06996 12/11/2025 12:05:54 SOC:34993,56536,37957,114800,67,40,39,359 06997 12/11/2025 12:05:54 Discharge cutback 66% 06998 12/11/2025 12:05:54 567A 06999 12/11/2025 12:06:54 Discharge level 039 AH, SOC: 37%, I: 2A, L:3617, l:3698, H:3661, B:044, PT:033C, BT:023C, PV:102204, M:Bike On 07000 12/11/2025 12:06:54 SOC:36629,57264,39960,114800,66,56,37,142 07001 12/11/2025 12:06:54 Discharge cutback 68% 07002 12/11/2025 12:06:54 584A 07003 12/11/2025 12:07:54 Discharge level 040 AH, SOC: 38%, I:422A, L:3330, l:3539, H:3452, B:122, PT:034C, BT:025C, PV: 95720, M:Bike On 07004 12/11/2025 12:07:54 SOC:37248,59870,40636,114800,65,23,38,382 07005 12/11/2025 12:07:54 Discharge cutback 82% 07006 12/11/2025 12:07:54 709A 07007 12/11/2025 12:08:54 Discharge level 042 AH, SOC: 37%, I: 0A, L:3622, l:3684, H:3658, B:036, PT:034C, BT:025C, PV:102193, M:Bike On 07008 12/11/2025 12:08:54 SOC:38888,61141,42462,114800,64,55,37,113 07009 12/11/2025 12:08:54 Discharge cutback 76% 07010 12/11/2025 12:08:54 651A 07011 12/11/2025 12:09:54 Discharge level 046 AH, SOC: 31%, I:251A, L:3335, l:3553, H:3446, B:111, PT:035C, BT:026C, PV: 95710, M:Bike On 07012 12/11/2025 12:09:54 SOC:42569,60865,46166,114800,60,28,31,398 07013 12/11/2025 12:09:54 Discharge cutback 53% 07014 12/11/2025 12:09:54 455A 07015 12/11/2025 12:10:54 Discharge level 048 AH, SOC: 29%, I:-31A, L:3588, l:3665, H:3624, B:036, PT:036C, BT:026C, PV:101247, M:Bike On 07016 12/11/2025 12:10:54 SOC:44122,61482,48136,114800,59,52,29,143 07017 12/11/2025 12:10:54 Discharge cutback 61% 07018 12/11/2025 12:10:54 523A 07019 12/11/2025 12:11:54 Discharge level 048 AH, SOC: 32%, I: 1A, L:3615, l:3659, H:3647, B:032, PT:036C, BT:025C, PV:101936, M:Bike On 07020 12/11/2025 12:11:54 SOC:43456,63269,48253,114800,58,51,32,83 07021 12/11/2025 12:11:54 Discharge cutback 79% 07022 12/11/2025 12:11:54 682A 07023 12/11/2025 12:12:54 Discharge level 048 AH, SOC: 35%, I: 1A, L:3637, l:3662, H:3661, B:024, PT:036C, BT:027C, PV:102383, M:Bike On 07024 12/11/2025 12:12:54 SOC:43479,66490,48279,114800,58,52,35,47 07025 12/11/2025 12:12:54 Discharge cutback 85% 07026 12/11/2025 12:12:54 736A 07027 12/11/2025 12:13:30 Contactor was Opened Pack V: 102523mV, Switched V: 102478mV, Prechg Pct: 100%, Dischg Cur: 1546mA 07028 12/11/2025 12:13:30 System Turned Off 07029 12/11/2025 12:13:31 DEBUG: CAN Link Is Down 07030 12/11/2025 12:13:31 DEBUG: Entered Idle State 07031 12/11/2025 12:13:37 Current Sensor Zeroed old: 2504mV, new: 2505mV, corrfact: 251 07032 12/11/2025 12:13:39 Discharge level 048 AH, SOC: 37%, I: 0A, L:3646, l:3664, H:3668, B:022, PT:036C, BT:026C, PV:102573, M:Idle 07033 12/11/2025 12:13:39 SOC:43479,68340,48294,114800,58,52,37,35 07034 12/11/2025 12:13:50 System Turned On 07035 12/11/2025 12:13:50 Rev:45,Build:2023-05-20_045619 958 banka 07036 12/11/2025 12:13:50 Pack:2019_monolith,Numbricks:4 07037 12/11/2025 12:13:50 DEBUG: Entered Running State 07038 12/11/2025 12:13:50 DEBUG: CAN NOT Receiving Syncs 07039 12/11/2025 12:13:51 DEBUG: CAN Link Is Up 07040 12/11/2025 12:13:51 DEBUG: Resetting CAN0 due to error passive mode 07041 12/11/2025 12:13:52 Discharge level 048 AH, SOC: 37%, I: 0A, L:3647, l:3665, H:3669, B:022, PT:036C, BT:027C, PV:102606, M:Bike On 07042 12/11/2025 12:13:52 SOC:43468,68340,48294,114800,58,52,37,35 07043 12/11/2025 12:13:52 Discharge cutback 88% 07044 12/11/2025 12:13:52 759A 07045 12/11/2025 12:13:55 DEBUG: CAN Receiving Syncs 07046 12/11/2025 12:13:55 Contactor drive turned on Pack V: 102613mV, Switched V: 90308mV, Duty Cycle: 39% 07047 12/11/2025 12:13:55 Contactor was Closed Pack V: 102613mV, Switched V: 90308mV, Prechg Pct: 88%, Dischg Cur: 727mA 07048 12/11/2025 12:14:02 DEBUG: Entered Charging State 07049 12/11/2025 12:14:02 DEBUG: CAN NOT Receiving Syncs 07050 12/11/2025 12:14:04 Discharge level 048 AH, SOC: 37%, I: 1A, L:3649, l:3666, H:3670, B:021, PT:036C, BT:026C, PV:102636, M:Charge 07051 12/11/2025 12:14:04 SOC:43413,68699,48296,114800,58,52,37,33 07052 12/11/2025 12:14:04 DEBUG: CAN Receiving Syncs 07053 12/11/2025 12:24:04 Discharge level 046 AH, SOC: 51%, I:-11A, L:3703, l:3693, H:3714, B:011, PT:036C, BT:032C, PV:103927, M:Charge 07054 12/11/2025 12:24:04 SOC:26448,53803,46338,114800,60,56,51,-20 07055 12/11/2025 12:34:04 Discharge level 044 AH, SOC: 59%, I:-11A, L:3725, l:3713, H:3733, B:008, PT:036C, BT:037C, PV:104472, M:Charge 07056 12/11/2025 12:34:04 SOC:20934,50270,44376,114800,62,59,59,-21 07057 12/11/2025 12:44:04 Discharge level 042 AH, SOC: 63%, I:-11A, L:3747, l:3735, H:3751, B:004, PT:035C, BT:038C, PV:104993, M:Charge 07058 12/11/2025 12:44:04 SOC:18939,50226,42444,114800,64,62,63,-22 07059 12/11/2025 12:54:11 Discharge level 040 AH, SOC: 66%, I:-11A, L:3767, l:3754, H:3770, B:003, PT:035C, BT:039C, PV:105528, M:Charge 07060 12/11/2025 12:54:11 SOC:17883,51145,40487,114800,65,64,66,-22 07061 12/11/2025 13:04:11 Discharge level 038 AH, SOC: 68%, I:-11A, L:3786, l:3773, H:3791, B:005, PT:034C, BT:040C, PV:106067, M:Charge 07062 12/11/2025 13:04:11 SOC:17171,52362,38576,114800,67,66,68,-21 07063 12/11/2025 13:14:11 Discharge level 036 AH, SOC: 70%, I:-11A, L:3806, l:3793, H:3811, B:005, PT:034C, BT:040C, PV:106633, M:Charge 07064 12/11/2025 13:14:11 SOC:16503,53618,36669,114800,69,68,70,-21 07065 12/11/2025 13:24:11 Discharge level 034 AH, SOC: 72%, I:-11A, L:3827, l:3814, H:3834, B:007, PT:033C, BT:041C, PV:107230, M:Charge 07066 12/11/2025 13:24:11 SOC:15686,54712,34775,114800,70,71,72,-21 07067 12/11/2025 13:34:11 Discharge level 032 AH, SOC: 74%, I:-10A, L:3849, l:3836, H:3855, B:006, PT:033C, BT:040C, PV:107850, M:Charge 07068 12/11/2025 13:34:11 SOC:14772,55700,32890,114800,72,73,74,-21 07069 12/11/2025 13:44:11 Discharge level 031 AH, SOC: 76%, I:-10A, L:3874, l:3860, H:3878, B:004, PT:033C, BT:041C, PV:108523, M:Charge 07070 12/11/2025 13:44:11 SOC:13700,56525,31013,114800,73,75,76,-21 07071 12/11/2025 13:54:11 Discharge level 029 AH, SOC: 78%, I:-11A, L:3896, l:3882, H:3900, B:004, PT:032C, BT:041C, PV:109163, M:Charge 07072 12/11/2025 13:54:11 SOC:12641,57351,29147,114800,75,77,78,-21 07073 12/11/2025 14:04:19 Discharge level 027 AH, SOC: 81%, I:-10A, L:3918, l:3904, H:3922, B:004, PT:032C, BT:044C, PV:109785, M:Charge 07074 12/11/2025 14:04:19 SOC:11636,58227,27286,114800,77,80,81,-20 07075 12/11/2025 14:14:19 Discharge level 025 AH, SOC: 82%, I:-11A, L:3937, l:3923, H:3943, B:006, PT:031C, BT:043C, PV:110352, M:Charge 07076 12/11/2025 14:14:19 SOC:10705,59145,25456,114800,78,81,82,-21 07077 12/11/2025 14:24:19 Discharge level 023 AH, SOC: 84%, I:-10A, L:3957, l:3943, H:3962, B:005, PT:031C, BT:045C, PV:110905, M:Charge 07078 12/11/2025 14:24:19 SOC:9785,60067,23632,114800,80,83,84,-20 07079 12/11/2025 14:34:19 Discharge level 021 AH, SOC: 86%, I:-10A, L:3977, l:3963, H:3981, B:004, PT:030C, BT:044C, PV:111443, M:Charge 07080 12/11/2025 14:34:19 SOC:8777,60888,21823,114800,81,85,86,-20 07081 12/11/2025 14:44:19 Discharge level 020 AH, SOC: 88%, I:-10A, L:3996, l:3983, H:4000, B:004, PT:030C, BT:043C, PV:111965, M:Charge 07082 12/11/2025 14:44:20 SOC:8000,61919,20033,114800,83,87,88,-20 07083 12/11/2025 14:54:19 Discharge level 018 AH, SOC: 89%, I:-11A, L:4016, l:4002, H:4019, B:003, PT:029C, BT:040C, PV:112501, M:Charge 07084 12/11/2025 14:54:20 SOC:7036,62745,18262,114800,85,88,89,-20 07085 12/11/2025 14:58:42 Charged To Full 017 AH, SOC: 90%, L:4025, H:4027, B:002, PT:029C, BT:039C, PV:112740 07086 12/11/2025 14:58:42 SOC adjusted for voltage old: 6507424uAH (soc:90%), new: 6300044uAH (soc:90%), low cell: 4025 mV 07087 12/11/2025 15:04:19 Discharge level 010 AH, SOC: 91%, I:-10A, L:4036, l:4023, H:4038, B:002, PT:029C, BT:036C, PV:113055, M:Charge 07088 12/11/2025 15:04:20 SOC:5859,63568,10482,114800,91,90,91,-20 07089 12/11/2025 15:14:19 Discharge level 008 AH, SOC: 93%, I:-10A, L:4056, l:4043, H:4058, B:002, PT:029C, BT:033C, PV:113592, M:Charge 07090 12/11/2025 15:14:20 SOC:4797,64284,8724,114800,93,92,93,-19 07091 12/11/2025 15:24:20 Discharge level 006 AH, SOC: 95%, I:-10A, L:4075, l:4062, H:4078, B:003, PT:028C, BT:031C, PV:114143, M:Charge 07092 12/11/2025 15:24:20 SOC:3595,64844,6981,114800,94,94,95,-19 07093 12/11/2025 15:34:27 Discharge level 005 AH, SOC: 97%, I:-10A, L:4094, l:4081, H:4097, B:003, PT:028C, BT:032C, PV:114684, M:Charge 07094 12/11/2025 15:34:27 SOC:2452,65467,5236,114800,96,96,97,-19 07095 12/11/2025 16:16:29 DEBUG: CAN Link Is Down 07096 12/11/2025 16:16:33 DEBUG: CAN Link Is Up 07097 12/11/2025 16:16:33 Contactor was Opened Pack V: 116104mV, Switched V: 116105mV, Prechg Pct: 100%, Dischg Cur: 454mA 07098 12/11/2025 16:16:35 System Turned Off 07099 12/11/2025 16:16:36 DEBUG: CAN Link Is Down 07100 12/11/2025 16:16:36 DEBUG: Entered Idle State 07101 12/11/2025 16:16:42 Current Sensor Zeroed old: 2505mV, new: 2507mV, corrfact: 249 07102 12/11/2025 16:16:43 Discharge level 000 AH, SOC:100%, I: 0A, L:4148, l:4145, H:4152, B:004, PT:026C, BT:035C, PV:116194, M:Idle 07103 12/11/2025 16:16:43 SOC:0,66547,0,114800,100,100,100,-4 07104 12/11/2025 16:17:03 Voltage Across Contactor: 103324mV (Okay) 07105 12/11/2025 21:55:27 System Turned On 07106 12/11/2025 21:55:27 Rev:45,Build:2023-05-20_045619 958 banka 07107 12/11/2025 21:55:27 Pack:2019_monolith,Numbricks:4 07108 12/11/2025 21:55:27 DEBUG: Entered Charging State 07109 12/11/2025 21:55:27 DEBUG: CAN NOT Receiving Syncs 07110 12/11/2025 21:55:28 DEBUG: Entered Running State 07111 12/11/2025 21:55:28 DEBUG: CAN Link Is Up 07112 12/11/2025 21:55:28 DEBUG: Resetting CAN0 due to error passive mode 07113 12/11/2025 21:55:29 Discharge level 000 AH, SOC:100%, I: 0A, L:4123, l:4119, H:4130, B:007, PT:017C, BT:021C, PV:115554, M:Bike On 07114 12/11/2025 21:55:29 SOC:0,66547,0,114800,100,100,100,-3 07115 12/11/2025 21:55:31 DEBUG: CAN Receiving Syncs 07116 12/11/2025 21:55:36 Contactor drive turned on Pack V: 115508mV, Switched V: 102203mV, Duty Cycle: 34% 07117 12/11/2025 21:55:36 Contactor was Closed Pack V: 115508mV, Switched V: 102203mV, Prechg Pct: 88%, Dischg Cur: 818mA 07118 12/11/2025 21:56:29 Discharge level 000 AH, SOC:100%, I: 1A, L:4121, l:4121, H:4127, B:006, PT:017C, BT:021C, PV:115492, M:Bike On 07119 12/11/2025 21:56:29 SOC:23,66515,12,114800,100,100,100,0 07120 12/11/2025 21:57:29 Discharge level 000 AH, SOC:100%, I: 1A, L:4114, l:4120, H:4122, B:008, PT:017C, BT:021C, PV:115328, M:Bike On 07121 12/11/2025 21:57:29 SOC:125,66366,106,114800,100,99,100,5 07122 12/11/2025 21:58:29 Discharge level 000 AH, SOC:100%, I: 98A, L:3928, l:4014, H:3960, B:032, PT:017C, BT:021C, PV:110440, M:Bike On 07123 12/11/2025 21:58:29 SOC:514,65752,482,114800,100,89,100,83 07124 12/11/2025 21:59:29 Discharge level 001 AH, SOC: 97%, I: 46A, L:3951, l:4035, H:3976, B:025, PT:018C, BT:021C, PV:111006, M:Bike On 07125 12/11/2025 21:59:29 SOC:1929,64182,1884,114800,99,91,97,81 07126 12/11/2025 22:00:29 Discharge level 003 AH, SOC: 95%, I: 0A, L:3998, l:4076, H:4017, B:019, PT:018C, BT:021C, PV:112257, M:Bike On 07127 12/11/2025 22:00:29 SOC:3273,62538,3222,114800,98,95,95,80 07128 12/11/2025 22:01:29 Discharge level 003 AH, SOC: 95%, I: 37A, L:3958, l:4036, H:3983, B:025, PT:019C, BT:021C, PV:111241, M:Bike On 07129 12/11/2025 22:01:29 SOC:3697,61710,3772,114800,97,91,95,80 07130 12/11/2025 22:02:29 Discharge level 004 AH, SOC: 94%, I: 1A, L:4014, l:4057, H:4031, B:017, PT:019C, BT:021C, PV:112684, M:Bike On 07131 12/11/2025 22:02:29 SOC:4226,61092,4297,114800,97,93,94,44 07132 12/11/2025 22:03:29 Discharge level 004 AH, SOC: 93%, I: 34A, L:3964, l:4015, H:3989, B:025, PT:019C, BT:022C, PV:111406, M:Bike On 07133 12/11/2025 22:03:29 SOC:4423,60869,4493,114800,97,89,93,52 07134 12/11/2025 22:04:29 Discharge level 005 AH, SOC: 91%, I: 79A, L:3839, l:3963, H:3880, B:041, PT:019C, BT:021C, PV:108161, M:Bike On 07135 12/11/2025 22:04:29 SOC:5531,59808,5614,114800,96,84,91,125 07136 12/11/2025 22:05:29 Discharge level 006 AH, SOC: 90%, I: 59A, L:3894, l:3980, H:3927, B:033, PT:020C, BT:022C, PV:109585, M:Bike On 07137 12/11/2025 22:05:29 SOC:6234,59286,6318,114800,95,86,90,92 07138 12/11/2025 22:06:29 Discharge level 007 AH, SOC: 88%, I:403A, L:3337, l:3698, H:3455, B:118, PT:020C, BT:021C, PV: 95269, M:Bike On 07139 12/11/2025 22:06:29 SOC:7381,58385,7467,114800,94,54,88,381 07140 12/11/2025 22:06:29 Discharge cutback 86% 07141 12/11/2025 22:06:29 739A 07142 12/11/2025 22:07:29 Discharge level 009 AH, SOC: 83%, I:170A, L:3613, l:3845, H:3683, B:070, PT:021C, BT:022C, PV:102317, M:Bike On 07143 12/11/2025 22:07:29 SOC:9796,56970,9888,114800,92,72,83,256 07144 12/11/2025 22:08:29 Discharge level 012 AH, SOC: 79%, I:174A, L:3615, l:3842, H:3684, B:069, PT:022C, BT:022C, PV:102398, M:Bike On 07145 12/11/2025 22:08:29 SOC:11916,55923,12039,114800,90,72,79,249 07146 12/11/2025 22:08:29 Discharge cutback 84% 07147 12/11/2025 22:08:29 725A 07148 12/11/2025 22:09:29 Discharge level 015 AH, SOC: 73%, I:153A, L:3564, l:3819, H:3644, B:080, PT:024C, BT:021C, PV:101252, M:Bike On 07149 12/11/2025 22:09:29 SOC:15182,54869,15308,114800,87,70,73,297 07150 12/11/2025 22:10:29 Discharge level 017 AH, SOC: 69%, I:407A, L:3276, l:3665, H:3417, B:141, PT:025C, BT:022C, PV: 94340, M:Bike On 07151 12/11/2025 22:10:29 SOC:17510,54787,17641,114800,85,48,69,464 07152 12/11/2025 22:10:29 Discharge cutback 70% 07153 12/11/2025 22:10:29 601A 07154 12/11/2025 22:11:29 Discharge level 019 AH, SOC: 65%, I: 2A, L:3761, l:3873, H:3800, B:039, PT:026C, BT:022C, PV:106091, M:Bike On 07155 12/11/2025 22:11:29 SOC:19402,55195,19573,114800,83,76,65,139 07156 12/11/2025 22:12:29 Discharge level 021 AH, SOC: 63%, I:182A, L:3550, l:3750, H:3635, B:085, PT:027C, BT:022C, PV:101048, M:Bike On 07157 12/11/2025 22:12:29 SOC:21003,55972,21212,114800,82,62,63,257 07158 12/11/2025 22:13:29 Discharge level 022 AH, SOC: 61%, I: 88A, L:3662, l:3791, H:3719, B:057, PT:027C, BT:022C, PV:103676, M:Bike On 07159 12/11/2025 22:13:29 SOC:22386,56981,22622,114800,81,68,61,174 07160 12/11/2025 22:14:29 Discharge level 024 AH, SOC: 58%, I: 5A, L:3664, l:3807, H:3716, B:052, PT:028C, BT:024C, PV:103675, M:Bike On 07161 12/11/2025 22:14:29 SOC:24548,57374,24797,114800,79,69,58,194 07162 12/11/2025 22:14:29 Discharge cutback 73% 07163 12/11/2025 22:14:29 624A 07164 12/11/2025 22:15:29 Discharge level 025 AH, SOC: 57%, I: 80A, L:3642, l:3761, H:3697, B:055, PT:029C, BT:024C, PV:103099, M:Bike On 07165 12/11/2025 22:15:29 SOC:25677,58597,25965,114800,78,64,57,168 07166 12/11/2025 22:16:29 Discharge level 027 AH, SOC: 55%, I: 91A, L:3617, l:3739, H:3676, B:059, PT:029C, BT:023C, PV:102457, M:Bike On 07167 12/11/2025 22:16:29 SOC:27161,59606,27470,114800,77,61,55,174 07168 12/11/2025 22:17:29 Discharge level 029 AH, SOC: 52%, I:273A, L:3410, l:3621, H:3516, B:106, PT:030C, BT:024C, PV: 97598, M:Bike On 07169 12/11/2025 22:17:29 SOC:29070,60227,29403,114800,75,42,52,320 07170 12/11/2025 22:17:29 Discharge cutback 85% 07171 12/11/2025 22:17:29 732A 07172 12/11/2025 22:18:29 Discharge level 033 AH, SOC: 45%, I:218A, L:3362, l:3609, H:3477, B:115, PT:031C, BT:023C, PV: 96479, M:Bike On 07173 12/11/2025 22:18:29 SOC:32859,59200,33194,114800,72,39,45,382 07174 12/11/2025 22:18:29 Discharge cutback 55% 07175 12/11/2025 22:18:29 476A 07176 12/11/2025 22:19:29 Discharge level 035 AH, SOC: 42%, I:152A, L:3468, l:3642, H:3550, B:082, PT:032C, BT:025C, PV: 98773, M:Bike On 07177 12/11/2025 22:19:29 SOC:34997,59604,35381,114800,70,46,42,281 07178 12/11/2025 22:19:29 Discharge cutback 57% 07179 12/11/2025 22:19:29 489A 07180 12/11/2025 22:20:29 Discharge level 038 AH, SOC: 35%, I:207A, L:3339, l:3569, H:3451, B:112, PT:033C, BT:025C, PV: 95804, M:Bike On 07181 12/11/2025 22:20:29 SOC:38289,58569,38805,114800,67,30,35,386 07182 12/11/2025 22:20:29 Discharge cutback 49% 07183 12/11/2025 22:20:29 418A 07184 12/11/2025 22:21:29 Discharge level 039 AH, SOC: 35%, I:141A, L:3496, l:3623, H:3565, B:069, PT:033C, BT:025C, PV: 99303, M:Bike On 07185 12/11/2025 22:21:29 SOC:39004,59536,39952,114800,66,44,35,222 07186 12/11/2025 22:21:29 Discharge cutback 73% 07187 12/11/2025 22:21:29 631A 07188 12/11/2025 22:22:29 Discharge level 040 AH, SOC: 36%, I: 1A, L:3617, l:3672, H:3654, B:037, PT:034C, BT:025C, PV:102071, M:Bike On 07189 12/11/2025 22:22:29 SOC:39101,60858,40599,114800,65,53,36,97 07190 12/11/2025 22:22:29 Discharge cutback 81% 07191 12/11/2025 22:22:29 695A 07192 12/11/2025 22:23:29 Discharge level 041 AH, SOC: 38%, I: 17A, L:3633, l:3669, H:3663, B:030, PT:034C, BT:026C, PV:102369, M:Bike On 07193 12/11/2025 22:23:29 SOC:39235,62573,41093,114800,65,53,38,66 07194 12/11/2025 22:23:29 Discharge cutback 85% 07195 12/11/2025 22:23:29 736A 07196 12/11/2025 22:24:29 Discharge level 041 AH, SOC: 39%, I: 1A, L:3653, l:3675, H:3677, B:024, PT:034C, BT:026C, PV:102817, M:Bike On 07197 12/11/2025 22:24:29 SOC:39152,64110,41425,114800,64,54,39,41 07198 12/11/2025 22:24:29 Discharge cutback 88% 07199 12/11/2025 22:24:29 759A 07200 12/11/2025 22:25:29 Discharge level 041 AH, SOC: 41%, I: 0A, L:3663, l:3679, H:3684, B:021, PT:034C, BT:026C, PV:103012, M:Bike On 07201 12/11/2025 22:25:29 SOC:38558,64548,41591,114800,64,54,41,29 07202 12/11/2025 22:26:12 Contactor was Opened Pack V: 103144mV, Switched V: 103108mV, Prechg Pct: 100%, Dischg Cur: 545mA 07203 12/11/2025 22:26:13 System Turned Off 07204 12/11/2025 22:26:14 DEBUG: CAN Link Is Down 07205 12/11/2025 22:26:14 DEBUG: Entered Idle State 07206 12/11/2025 22:26:19 Current Sensor Zeroed old: 2507mV, new: 2504mV, corrfact: 252 07207 12/11/2025 22:26:21 Discharge level 041 AH, SOC: 42%, I: 0A, L:3670, l:3681, H:3689, B:019, PT:034C, BT:025C, PV:103178, M:Idle 07208 12/11/2025 22:26:21 SOC:37944,64606,41594,114800,64,55,42,20 07209 12/11/2025 22:26:21 System Turned On 07210 12/11/2025 22:26:21 Rev:45,Build:2023-05-20_045619 958 banka 07211 12/11/2025 22:26:21 Pack:2019_monolith,Numbricks:4 07212 12/11/2025 22:26:21 DEBUG: Entered Running State 07213 12/11/2025 22:26:22 DEBUG: CAN NOT Receiving Syncs 07214 12/11/2025 22:26:22 DEBUG: CAN Link Is Up 07215 12/11/2025 22:26:22 DEBUG: Resetting CAN0 due to error passive mode 07216 12/11/2025 22:26:23 Discharge level 041 AH, SOC: 42%, I: 0A, L:3669, l:3680, H:3689, B:020, PT:034C, BT:026C, PV:103176, M:Bike On 07217 12/11/2025 22:26:23 SOC:37935,64606,41594,114800,64,55,42,21 07218 12/11/2025 22:26:26 DEBUG: CAN Receiving Syncs 07219 12/11/2025 22:26:26 Contactor drive turned on Pack V: 103179mV, Switched V: 90899mV, Duty Cycle: 39% 07220 12/11/2025 22:26:26 Contactor was Closed Pack V: 103179mV, Switched V: 90899mV, Prechg Pct: 88%, Dischg Cur: 636mA 07221 12/11/2025 22:26:53 DEBUG: Entered Charging State 07222 12/11/2025 22:26:53 DEBUG: CAN NOT Receiving Syncs 07223 12/11/2025 22:26:54 Discharge level 041 AH, SOC: 42%, I: 0A, L:3672, l:3681, H:3691, B:019, PT:034C, BT:026C, PV:103235, M:Charge 07224 12/11/2025 22:26:54 SOC:37540,64705,41595,114800,64,55,42,18 07225 12/11/2025 22:26:54 DEBUG: CAN Receiving Syncs 07226 12/11/2025 22:36:54 Discharge level 039 AH, SOC: 56%, I:-11A, L:3728, l:3716, H:3736, B:008, PT:033C, BT:034C, PV:104560, M:Charge 07227 12/11/2025 22:36:54 SOC:23679,52938,39595,114800,66,60,56,-21 07228 12/11/2025 22:46:54 Discharge level 037 AH, SOC: 62%, I:-11A, L:3753, l:3741, H:3757, B:004, PT:033C, BT:038C, PV:105150, M:Charge 07229 12/11/2025 22:46:54 SOC:19215,50444,37641,114800,68,62,62,-21 07230 12/11/2025 22:56:54 Discharge level 035 AH, SOC: 66%, I:-11A, L:3774, l:3761, H:3778, B:004, PT:033C, BT:040C, PV:105730, M:Charge 07231 12/11/2025 22:56:54 SOC:17402,50561,35728,114800,69,65,66,-22 07232 12/11/2025 23:07:02 Discharge level 033 AH, SOC: 69%, I:-11A, L:3795, l:3782, H:3799, B:004, PT:033C, BT:041C, PV:106307, M:Charge 07233 12/11/2025 23:07:02 SOC:16517,51620,33802,114800,71,67,69,-21 07234 12/11/2025 23:17:02 Discharge level 031 AH, SOC: 71%, I:-11A, L:3815, l:3801, H:3821, B:006, PT:032C, BT:042C, PV:106899, M:Charge 07235 12/11/2025 23:17:02 SOC:15721,52741,31903,114800,73,69,71,-21 07236 12/11/2025 23:27:02 Discharge level 030 AH, SOC: 73%, I:-11A, L:3837, l:3823, H:3843, B:006, PT:032C, BT:042C, PV:107515, M:Charge 07237 12/11/2025 23:27:02 SOC:14876,53771,30044,114800,74,72,73,-21 07238 12/11/2025 23:37:02 Discharge level 028 AH, SOC: 75%, I:-11A, L:3861, l:3847, H:3866, B:005, PT:032C, BT:042C, PV:108168, M:Charge 07239 12/11/2025 23:37:02 SOC:13905,54671,28190,114800,76,74,75,-21 07240 12/11/2025 23:47:02 Discharge level 026 AH, SOC: 77%, I:-11A, L:3885, l:3871, H:3889, B:004, PT:032C, BT:043C, PV:108839, M:Charge 07241 12/11/2025 23:47:02 SOC:12811,55430,26353,114800,78,76,77,-21 07242 12/11/2025 23:57:02 Discharge level 024 AH, SOC: 79%, I:-11A, L:3906, l:3892, H:3911, B:005, PT:031C, BT:043C, PV:109460, M:Charge 07243 12/11/2025 23:57:02 SOC:11839,56312,24515,114800,79,78,79,-21 07244 12/12/2025 00:07:02 Discharge level 022 AH, SOC: 81%, I:-10A, L:3927, l:3914, H:3933, B:006, PT:031C, BT:044C, PV:110067, M:Charge 07245 12/12/2025 00:07:02 SOC:10892,57232,22665,114800,81,80,81,-20 07246 12/12/2025 00:17:10 Discharge level 020 AH, SOC: 83%, I:-11A, L:3947, l:3933, H:3953, B:006, PT:031C, BT:046C, PV:110624, M:Charge 07247 12/12/2025 00:17:10 SOC:10009,58229,20803,114800,82,82,83,-21 07248 12/12/2025 00:27:10 Discharge level 018 AH, SOC: 85%, I:-10A, L:3967, l:3954, H:3972, B:005, PT:031C, BT:045C, PV:111171, M:Charge 07249 12/12/2025 00:27:10 SOC:9128,59189,18978,114800,84,84,85,-20 07250 12/12/2025 00:37:10 Discharge level 017 AH, SOC: 87%, I:-10A, L:3985, l:3972, H:3991, B:006, PT:030C, BT:045C, PV:111704, M:Charge 07251 12/12/2025 00:37:10 SOC:8292,60169,17180,114800,86,86,87,-20 07252 12/12/2025 00:47:10 Discharge level 015 AH, SOC: 88%, I:-10A, L:4005, l:3992, H:4009, B:004, PT:030C, BT:043C, PV:112231, M:Charge 07253 12/12/2025 00:47:10 SOC:7397,61099,15374,114800,87,87,88,-20 07254 12/12/2025 00:57:10 Discharge level 013 AH, SOC: 90%, I:-10A, L:4025, l:4013, H:4029, B:004, PT:030C, BT:044C, PV:112774, M:Charge 07255 12/12/2025 00:57:10 SOC:6340,61875,13557,114800,89,89,90,-20 07256 12/12/2025 00:57:11 Charged To Full 013 AH, SOC: 90%, L:4025, H:4028, B:003, PT:030C, BT:044C, PV:112772 07257 12/12/2025 00:57:11 SOC adjusted for voltage old: 6339749uAH (soc:90%), new: 6187757uAH (soc:90%), low cell: 4025 mV 07258 12/12/2025 01:07:10 Discharge level 009 AH, SOC: 92%, I:-11A, L:4045, l:4032, H:4049, B:004, PT:030C, BT:043C, PV:113336, M:Charge 07259 12/12/2025 01:07:10 SOC:5236,62734,9687,114800,92,91,92,-20 07260 12/12/2025 01:17:10 Discharge level 007 AH, SOC: 94%, I:-10A, L:4065, l:4052, H:4068, B:003, PT:029C, BT:039C, PV:113872, M:Charge 07261 12/12/2025 01:17:10 SOC:4077,63376,7905,114800,94,93,94,-20 07262 12/12/2025 01:27:10 Discharge level 006 AH, SOC: 96%, I:-10A, L:4086, l:4074, H:4088, B:002, PT:029C, BT:035C, PV:114428, M:Charge 07263 12/12/2025 01:27:10 SOC:2898,63971,6148,114800,95,95,96,-19 07264 12/12/2025 01:37:10 Discharge level 004 AH, SOC: 98%, I:-10A, L:4105, l:4092, H:4108, B:003, PT:029C, BT:034C, PV:114987, M:Charge 07265 12/12/2025 01:37:10 SOC:1693,64542,4391,114800,97,97,98,-20 07266 12/12/2025 02:13:00 DEBUG: CAN Link Is Down 07267 12/12/2025 02:13:04 DEBUG: CAN Link Is Up 07268 12/12/2025 02:13:05 Contactor was Opened Pack V: 116101mV, Switched V: 116066mV, Prechg Pct: 100%, Dischg Cur: 545mA 07269 12/12/2025 02:13:07 System Turned Off 07270 12/12/2025 02:13:07 DEBUG: CAN Link Is Down 07271 12/12/2025 02:13:08 DEBUG: Entered Idle State 07272 12/12/2025 02:13:15 Discharge level 000 AH, SOC:100%, I: 0A, L:4148, l:4146, H:4151, B:003, PT:028C, BT:037C, PV:116193, M:Idle 07273 12/12/2025 02:13:15 SOC:0,65330,0,114800,100,100,100,-3 07274 12/12/2025 02:13:34 Voltage Across Contactor: 103366mV (Okay) 07275 12/12/2025 11:53:49 System Turned On 07276 12/12/2025 11:53:49 Rev:45,Build:2023-05-20_045619 958 banka 07277 12/12/2025 11:53:49 Pack:2019_monolith,Numbricks:4 07278 12/12/2025 11:53:49 DEBUG: Entered Charging State 07279 12/12/2025 11:53:49 DEBUG: CAN NOT Receiving Syncs 07280 12/12/2025 11:53:49 DEBUG: Entered Running State 07281 12/12/2025 11:53:49 DEBUG: CAN Link Is Up 07282 12/12/2025 11:53:50 DEBUG: Resetting CAN0 due to error passive mode 07283 12/12/2025 11:53:50 Discharge level 000 AH, SOC:100%, I: 0A, L:4122, l:4119, H:4130, B:008, PT:019C, BT:024C, PV:115543, M:Bike On 07284 12/12/2025 11:53:50 SOC:0,65330,0,114800,100,100,100,-3 07285 12/12/2025 11:53:53 DEBUG: CAN Receiving Syncs 07286 12/12/2025 11:53:53 Contactor drive turned on Pack V: 115520mV, Switched V: 101257mV, Duty Cycle: 34% 07287 12/12/2025 11:53:53 Contactor was Closed Pack V: 115520mV, Switched V: 101257mV, Prechg Pct: 88%, Dischg Cur: 363mA 07288 12/12/2025 11:54:50 Discharge level 000 AH, SOC:100%, I: 1A, L:4120, l:4120, H:4127, B:007, PT:018C, BT:023C, PV:115478, M:Bike On 07289 12/12/2025 11:54:50 SOC:6,65313,6,114800,100,100,100,0 07290 12/12/2025 11:55:50 Discharge level 000 AH, SOC:100%, I: -6A, L:4122, l:4134, H:4130, B:008, PT:019C, BT:023C, PV:115562, M:Bike On 07291 12/12/2025 11:55:50 SOC:291,64846,292,114800,100,100,100,13 07292 12/12/2025 11:56:50 Discharge level 000 AH, SOC: 99%, I: 2A, L:4021, l:4050, H:4041, B:020, PT:019C, BT:023C, PV:112903, M:Bike On 07293 12/12/2025 11:56:50 SOC:704,64145,715,114800,100,93,99,31 07294 12/12/2025 11:57:50 Discharge level 000 AH, SOC: 99%, I: 1A, L:4088, l:4102, H:4098, B:010, PT:019C, BT:023C, PV:114616, M:Bike On 07295 12/12/2025 11:57:50 SOC:879,63687,916,114800,100,98,99,15 07296 12/12/2025 11:58:50 Discharge level 000 AH, SOC: 99%, I: 38A, L:4027, l:4057, H:4044, B:017, PT:019C, BT:023C, PV:113010, M:Bike On 07297 12/12/2025 11:58:50 SOC:916,63408,991,114800,100,93,99,32 07298 12/12/2025 11:59:50 Discharge level 001 AH, SOC: 99%, I: 68A, L:3983, l:4036, H:4007, B:024, PT:019C, BT:023C, PV:111872, M:Bike On 07299 12/12/2025 11:59:50 SOC:1042,63077,1141,114800,100,91,99,58 07300 12/12/2025 12:00:50 Discharge level 001 AH, SOC: 98%, I: 19A, L:4044, l:4073, H:4059, B:015, PT:019C, BT:023C, PV:113470, M:Bike On 07301 12/12/2025 12:00:50 SOC:1654,62136,1795,114800,99,95,98,32 07302 12/12/2025 12:01:50 Discharge level 003 AH, SOC: 95%, I: 97A, L:3798, l:3951, H:3842, B:044, PT:019C, BT:023C, PV:107034, M:Bike On 07303 12/12/2025 12:01:50 SOC:3607,60147,3747,114800,97,84,95,166 07304 12/12/2025 12:02:50 Discharge level 005 AH, SOC: 92%, I: 2A, L:3955, l:4050, H:3976, B:021, PT:020C, BT:023C, PV:111091, M:Bike On 07305 12/12/2025 12:02:50 SOC:4973,58797,5158,114800,96,92,92,102 07306 12/12/2025 12:03:50 Discharge level 006 AH, SOC: 89%, I:101A, L:3761, l:3922, H:3808, B:047, PT:020C, BT:022C, PV:106044, M:Bike On 07307 12/12/2025 12:03:50 SOC:6701,57484,6886,114800,95,81,89,182 07308 12/12/2025 12:04:50 Discharge level 008 AH, SOC: 86%, I:109A, L:3768, l:3924, H:3816, B:048, PT:021C, BT:023C, PV:106272, M:Bike On 07309 12/12/2025 12:04:50 SOC:8123,56600,8310,114800,93,80,86,174 07310 12/12/2025 12:05:50 Discharge level 011 AH, SOC: 79%, I:219A, L:3517, l:3819, H:3600, B:083, PT:022C, BT:023C, PV: 99875, M:Bike On 07311 12/12/2025 12:05:50 SOC:11567,54767,11755,114800,90,70,79,356 07312 12/12/2025 12:06:50 Discharge level 014 AH, SOC: 74%, I:309A, L:3372, l:3733, H:3484, B:112, PT:024C, BT:023C, PV: 96383, M:Bike On 07313 12/12/2025 12:06:50 SOC:14386,54003,14577,114800,88,60,74,433 07314 12/12/2025 12:06:50 Discharge cutback 65% 07315 12/12/2025 12:06:50 560A 07316 12/12/2025 12:07:50 Discharge level 017 AH, SOC: 68%, I:197A, L:3510, l:3794, H:3597, B:087, PT:025C, BT:024C, PV: 99912, M:Bike On 07317 12/12/2025 12:07:50 SOC:17607,53698,17801,114800,85,66,68,350 07318 12/12/2025 12:08:50 Discharge level 020 AH, SOC: 62%, I:184A, L:3503, l:3757, H:3592, B:089, PT:027C, BT:023C, PV: 99821, M:Bike On 07319 12/12/2025 12:08:50 SOC:20801,53840,20996,114800,82,63,62,340 07320 12/12/2025 12:08:50 Discharge cutback 89% 07321 12/12/2025 12:08:50 769A 07322 12/12/2025 12:09:50 Discharge level 023 AH, SOC: 57%, I: 0A, L:3657, l:3816, H:3712, B:055, PT:028C, BT:024C, PV:103522, M:Bike On 07323 12/12/2025 12:09:50 SOC:23561,54131,23855,114800,80,69,57,226 07324 12/12/2025 12:09:50 Discharge cutback 67% 07325 12/12/2025 12:09:50 580A 07326 12/12/2025 12:10:50 Discharge level 027 AH, SOC: 51%, I:198A, L:3444, l:3689, H:3540, B:096, PT:030C, BT:024C, PV: 98340, M:Bike On 07327 12/12/2025 12:10:50 SOC:27001,54512,27298,114800,77,53,51,372 07328 12/12/2025 12:10:50 Discharge cutback 75% 07329 12/12/2025 12:10:50 648A 07330 12/12/2025 12:11:50 Discharge level 030 AH, SOC: 45%, I:186A, L:3436, l:3665, H:3534, B:098, PT:031C, BT:023C, PV: 98210, M:Bike On 07331 12/12/2025 12:11:50 SOC:30492,54941,30790,114800,74,49,45,370 07332 12/12/2025 12:11:50 Discharge cutback 69% 07333 12/12/2025 12:11:50 597A 07334 12/12/2025 12:12:50 Discharge level 033 AH, SOC: 40%, I:201A, L:3410, l:3627, H:3510, B:100, PT:033C, BT:025C, PV: 97540, M:Bike On 07335 12/12/2025 12:12:50 SOC:33577,55637,33903,114800,71,44,40,381 07336 12/12/2025 12:12:50 Discharge cutback 64% 07337 12/12/2025 12:12:50 553A 07338 12/12/2025 12:13:50 Discharge level 035 AH, SOC: 39%, I:171A, L:3520, l:3654, H:3590, B:070, PT:034C, BT:025C, PV:100001, M:Bike On 07339 12/12/2025 12:13:50 SOC:35288,57120,35762,114800,69,50,39,246 07340 12/12/2025 12:13:50 Discharge cutback 76% 07341 12/12/2025 12:13:50 655A 07342 12/12/2025 12:14:50 Discharge level 039 AH, SOC: 33%, I: 0A, L:3556, l:3679, H:3608, B:052, PT:035C, BT:025C, PV:100696, M:Bike On 07343 12/12/2025 12:14:50 SOC:39119,57825,39597,114800,66,54,33,226 07344 12/12/2025 12:14:50 Discharge cutback 61% 07345 12/12/2025 12:14:50 523A 07346 12/12/2025 12:15:50 Discharge level 041 AH, SOC: 31%, I: 50A, L:3543, l:3652, H:3597, B:054, PT:036C, BT:025C, PV:100343, M:Bike On 07347 12/12/2025 12:15:50 SOC:41084,59069,41852,114800,64,50,31,204 07348 12/12/2025 12:15:50 Discharge cutback 66% 07349 12/12/2025 12:15:51 570A 07350 12/12/2025 12:16:50 Discharge level 044 AH, SOC: 29%, I:150A, L:3437, l:3597, H:3516, B:079, PT:037C, BT:026C, PV: 97895, M:Bike On 07351 12/12/2025 12:16:50 SOC:43068,60519,44079,114800,62,39,29,302 07352 12/12/2025 12:16:50 Discharge cutback 57% 07353 12/12/2025 12:16:51 492A 07354 12/12/2025 12:17:50 Discharge level 047 AH, SOC: 25%, I:195A, L:3365, l:3552, H:3460, B:095, PT:038C, BT:026C, PV: 96223, M:Bike On 07355 12/12/2025 12:17:50 SOC:46324,61244,47363,114800,59,28,25,357 07356 12/12/2025 12:17:50 Discharge cutback 53% 07357 12/12/2025 12:17:51 455A 07358 12/12/2025 12:18:50 Discharge level 049 AH, SOC: 24%, I: 1A, L:3555, l:3637, H:3597, B:042, PT:039C, BT:027C, PV:100442, M:Bike On 07359 12/12/2025 12:18:50 SOC:47363,62077,49043,114800,58,47,24,156 07360 12/12/2025 12:18:50 Discharge cutback 61% 07361 12/12/2025 12:18:51 526A 07362 12/12/2025 12:19:50 Discharge level 049 AH, SOC: 27%, I: 1A, L:3594, l:3644, H:3627, B:033, PT:039C, BT:027C, PV:101347, M:Bike On 07363 12/12/2025 12:19:50 SOC:46769,63553,49406,114800,57,49,27,98 07364 12/12/2025 12:19:51 Discharge cutback 75% 07365 12/12/2025 12:19:51 644A 07366 12/12/2025 12:20:09 Contactor was Opened Pack V: 101550mV, Switched V: 101494mV, Prechg Pct: 100%, Dischg Cur: 1546mA 07367 12/12/2025 12:20:10 System Turned Off 07368 12/12/2025 12:20:11 DEBUG: CAN Link Is Down 07369 12/12/2025 12:20:11 DEBUG: Entered Idle State 07370 12/12/2025 12:20:16 Current Sensor Zeroed old: 2504mV, new: 2507mV, corrfact: 249 07371 12/12/2025 12:20:18 Discharge level 049 AH, SOC: 28%, I: 0A, L:3608, l:3650, H:3636, B:028, PT:039C, BT:028C, PV:101646, M:Idle 07372 12/12/2025 12:20:18 SOC:46759,64790,49415,114800,57,50,28,83 07373 12/12/2025 12:20:39 Voltage Across Contactor: 88997mV (Okay) 07374 12/12/2025 12:20:44 System Turned On 07375 12/12/2025 12:20:44 Rev:45,Build:2023-05-20_045619 958 banka 07376 12/12/2025 12:20:44 Pack:2019_monolith,Numbricks:4 07377 12/12/2025 12:20:44 DEBUG: Entered Running State 07378 12/12/2025 12:20:44 DEBUG: CAN NOT Receiving Syncs 07379 12/12/2025 12:20:44 DEBUG: CAN Link Is Up 07380 12/12/2025 12:20:45 DEBUG: Resetting CAN0 due to error passive mode 07381 12/12/2025 12:20:45 Discharge level 049 AH, SOC: 28%, I: 0A, L:3616, l:3658, H:3642, B:026, PT:039C, BT:028C, PV:101823, M:Bike On 07382 12/12/2025 12:20:45 SOC:46744,64790,49415,114800,57,51,28,83 07383 12/12/2025 12:20:45 Discharge cutback 81% 07384 12/12/2025 12:20:45 698A 07385 12/12/2025 12:20:48 DEBUG: CAN Receiving Syncs 07386 12/12/2025 12:20:49 Contactor drive turned on Pack V: 101840mV, Switched V: 89560mV, Duty Cycle: 39% 07387 12/12/2025 12:20:49 Contactor was Closed Pack V: 101840mV, Switched V: 89560mV, Prechg Pct: 88%, Dischg Cur: 545mA 07388 12/12/2025 12:20:51 DEBUG: Entered Charging State 07389 12/12/2025 12:20:51 DEBUG: CAN NOT Receiving Syncs 07390 12/12/2025 12:20:52 Discharge level 049 AH, SOC: 29%, I: 0A, L:3618, l:3658, H:3643, B:025, PT:039C, BT:027C, PV:101856, M:Charge 07391 12/12/2025 12:20:52 SOC:46620,64805,49415,114800,57,51,29,80 07392 12/12/2025 12:20:52 DEBUG: CAN Receiving Syncs 07393 12/12/2025 12:30:52 Discharge level 047 AH, SOC: 45%, I:-11A, L:3681, l:3672, H:3692, B:011, PT:039C, BT:031C, PV:103324, M:Charge 07394 12/12/2025 12:30:52 SOC:25168,45532,47390,114800,59,53,45,-18 07395 12/12/2025 12:40:52 Discharge level 045 AH, SOC: 55%, I:-12A, L:3701, l:3690, H:3709, B:008, PT:038C, BT:037C, PV:103802, M:Charge 07396 12/12/2025 12:40:52 SOC:18620,41015,45375,114800,61,56,55,-22 07397 12/12/2025 12:50:52 Discharge level 043 AH, SOC: 60%, I:-12A, L:3719, l:3707, H:3725, B:006, PT:038C, BT:041C, PV:104250, M:Charge 07398 12/12/2025 12:50:52 SOC:16745,41159,43373,114800,63,58,60,-22 07399 12/12/2025 13:00:59 Discharge level 041 AH, SOC: 63%, I:-12A, L:3737, l:3725, H:3741, B:004, PT:037C, BT:041C, PV:104704, M:Charge 07400 12/12/2025 13:01:00 SOC:16063,42495,41374,114800,64,61,63,-22 07401 12/12/2025 13:10:59 Discharge level 039 AH, SOC: 65%, I:-12A, L:3755, l:3743, H:3758, B:003, PT:037C, BT:041C, PV:105183, M:Charge 07402 12/12/2025 13:11:00 SOC:15803,44216,39411,114800,66,63,65,-22 07403 12/12/2025 13:21:00 Discharge level 037 AH, SOC: 67%, I:-11A, L:3772, l:3760, H:3776, B:004, PT:037C, BT:043C, PV:105669, M:Charge 07404 12/12/2025 13:21:00 SOC:15463,45833,37471,114800,68,65,67,-21 07405 12/12/2025 13:31:00 Discharge level 035 AH, SOC: 69%, I:-11A, L:3791, l:3779, H:3796, B:005, PT:036C, BT:045C, PV:106196, M:Charge 07406 12/12/2025 13:31:00 SOC:15158,47470,35545,114800,70,67,69,-21 07407 12/12/2025 13:41:00 Discharge level 033 AH, SOC: 71%, I:-11A, L:3810, l:3797, H:3815, B:005, PT:036C, BT:045C, PV:106746, M:Charge 07408 12/12/2025 13:41:00 SOC:14669,48933,33612,114800,71,69,71,-22 07409 12/12/2025 13:51:00 Discharge level 031 AH, SOC: 72%, I:-11A, L:3830, l:3817, H:3836, B:006, PT:036C, BT:045C, PV:107318, M:Charge 07410 12/12/2025 13:51:00 SOC:14076,50267,31702,114800,73,71,72,-21 07411 12/12/2025 14:01:00 Discharge level 029 AH, SOC: 75%, I:-11A, L:3853, l:3840, H:3858, B:005, PT:035C, BT:043C, PV:107940, M:Charge 07412 12/12/2025 14:01:00 SOC:13357,51481,29786,114800,75,73,75,-21 07413 12/12/2025 14:11:08 Discharge level 027 AH, SOC: 77%, I:-11A, L:3876, l:3863, H:3881, B:005, PT:035C, BT:043C, PV:108594, M:Charge 07414 12/12/2025 14:11:08 SOC:12492,52561,27861,114800,76,76,77,-21 07415 12/12/2025 14:21:08 Discharge level 025 AH, SOC: 79%, I:-11A, L:3899, l:3886, H:3903, B:004, PT:034C, BT:043C, PV:109228, M:Charge 07416 12/12/2025 14:21:08 SOC:11521,53494,25976,114800,78,78,79,-21 07417 12/12/2025 14:31:08 Discharge level 024 AH, SOC: 81%, I:-11A, L:3918, l:3906, H:3924, B:006, PT:034C, BT:044C, PV:109815, M:Charge 07418 12/12/2025 14:31:08 SOC:10625,54495,24099,114800,80,80,81,-21 07419 12/12/2025 14:41:08 Discharge level 022 AH, SOC: 83%, I:-11A, L:3938, l:3925, H:3944, B:006, PT:034C, BT:045C, PV:110381, M:Charge 07420 12/12/2025 14:41:08 SOC:9947,55684,22250,114800,81,81,83,-21 07421 12/12/2025 14:51:08 Discharge level 020 AH, SOC: 84%, I:-10A, L:3957, l:3945, H:3962, B:005, PT:033C, BT:045C, PV:110910, M:Charge 07422 12/12/2025 14:51:08 SOC:9116,56699,20422,114800,83,83,84,-20 07423 12/12/2025 15:01:08 Discharge level 018 AH, SOC: 86%, I:-11A, L:3977, l:3965, H:3982, B:005, PT:033C, BT:044C, PV:111453, M:Charge 07424 12/12/2025 15:01:08 SOC:8227,57650,18599,114800,84,85,86,-20 07425 12/12/2025 15:11:08 Discharge level 016 AH, SOC: 88%, I:-10A, L:3996, l:3984, H:4000, B:004, PT:032C, BT:043C, PV:111967, M:Charge 07426 12/12/2025 15:11:08 SOC:7453,58715,16779,114800,86,87,88,-20 07427 12/12/2025 15:21:16 Discharge level 014 AH, SOC: 89%, I:-11A, L:4015, l:4003, H:4019, B:004, PT:032C, BT:042C, PV:112499, M:Charge 07428 12/12/2025 15:21:16 SOC:6592,59694,14959,114800,87,88,89,-20 07429 12/12/2025 15:26:27 Charged To Full 014 AH, SOC: 90%, L:4026, H:4029, B:003, PT:032C, BT:042C, PV:112737 07430 12/12/2025 15:26:27 SOC adjusted for voltage old: 6080650uAH (soc:90%), new: 5411331uAH (soc:91%), low cell: 4026 mV 07431 12/12/2025 15:31:16 Discharge level 009 AH, SOC: 92%, I:-10A, L:4035, l:4023, H:4038, B:003, PT:031C, BT:040C, PV:113025, M:Charge 07432 12/12/2025 15:31:16 SOC:5397,60979,9473,114800,92,90,92,-20 07433 12/12/2025 15:41:16 Discharge level 007 AH, SOC: 93%, I:-10A, L:4055, l:4043, H:4058, B:003, PT:031C, BT:036C, PV:113583, M:Charge 07434 12/12/2025 15:41:16 SOC:4552,61932,7696,114800,94,92,93,-20 07435 12/12/2025 15:51:16 Discharge level 005 AH, SOC: 95%, I:-10A, L:4075, l:4063, H:4077, B:002, PT:031C, BT:034C, PV:114113, M:Charge 07436 12/12/2025 15:51:16 SOC:3438,62608,5926,114800,95,94,95,-20 07437 12/12/2025 16:01:16 Discharge level 004 AH, SOC: 97%, I:-10A, L:4093, l:4081, H:4096, B:003, PT:030C, BT:033C, PV:114643, M:Charge 07438 12/12/2025 16:01:16 SOC:2347,63285,4177,114800,97,96,97,-19 07439 12/12/2025 16:44:26 DEBUG: CAN Link Is Down 07440 12/12/2025 16:44:30 DEBUG: CAN Link Is Up 07441 12/12/2025 16:44:30 Contactor was Opened Pack V: 116137mV, Switched V: 116145mV, Prechg Pct: 100%, Dischg Cur: 363mA 07442 12/12/2025 16:44:32 System Turned Off 07443 12/12/2025 16:44:33 DEBUG: CAN Link Is Down 07444 12/12/2025 16:44:33 DEBUG: Entered Idle State 07445 12/12/2025 16:44:40 Discharge level 000 AH, SOC:100%, I: 0A, L:4150, l:4148, H:4154, B:004, PT:029C, BT:038C, PV:116234, M:Idle 07446 12/12/2025 16:44:40 SOC:0,64533,0,114800,100,100,100,-4 07447 12/12/2025 16:45:00 Voltage Across Contactor: 103370mV (Okay) 07448 12/12/2025 22:06:57 System Turned On 07449 12/12/2025 22:06:57 Rev:45,Build:2023-05-20_045619 958 banka 07450 12/12/2025 22:06:57 Pack:2019_monolith,Numbricks:4 07451 12/12/2025 22:06:57 DEBUG: Entered Charging State 07452 12/12/2025 22:06:57 DEBUG: CAN NOT Receiving Syncs 07453 12/12/2025 22:06:57 DEBUG: Entered Running State 07454 12/12/2025 22:06:57 DEBUG: CAN Link Is Up 07455 12/12/2025 22:06:58 DEBUG: Resetting CAN0 due to error passive mode 07456 12/12/2025 22:06:58 Discharge level 000 AH, SOC:100%, I: 0A, L:4126, l:4122, H:4133, B:007, PT:018C, BT:022C, PV:115642, M:Bike On 07457 12/12/2025 22:06:58 SOC:0,64533,0,114800,100,100,100,-3 07458 12/12/2025 22:07:01 DEBUG: CAN Receiving Syncs 07459 12/12/2025 22:07:01 Contactor drive turned on Pack V: 115589mV, Switched V: 101297mV, Duty Cycle: 34% 07460 12/12/2025 22:07:01 Contactor was Closed Pack V: 115589mV, Switched V: 101297mV, Prechg Pct: 88%, Dischg Cur: 818mA 07461 12/12/2025 22:07:58 Discharge level 000 AH, SOC:100%, I: 0A, L:4124, l:4124, H:4131, B:007, PT:018C, BT:021C, PV:115588, M:Bike On 07462 12/12/2025 22:07:58 SOC:13,64533,13,114800,100,100,100,0 07463 12/12/2025 22:08:58 Discharge level 000 AH, SOC:100%, I: 1A, L:4123, l:4123, H:4130, B:007, PT:018C, BT:022C, PV:115564, M:Bike On 07464 12/12/2025 22:08:58 SOC:26,64533,28,114800,100,100,100,0 07465 12/12/2025 22:09:58 Discharge level 000 AH, SOC:100%, I: 33A, L:4064, l:4092, H:4078, B:014, PT:018C, BT:021C, PV:114015, M:Bike On 07466 12/12/2025 22:09:58 SOC:82,64472,82,114800,100,97,100,26 07467 12/12/2025 22:10:58 Discharge level 000 AH, SOC:100%, I: 18A, L:4060, l:4091, H:4075, B:015, PT:018C, BT:021C, PV:113920, M:Bike On 07468 12/12/2025 22:10:58 SOC:375,64011,370,114800,100,97,100,30 07469 12/12/2025 22:11:58 Discharge level 001 AH, SOC: 99%, I: 24A, L:3919, l:4000, H:3951, B:032, PT:018C, BT:022C, PV:110236, M:Bike On 07470 12/12/2025 22:11:58 SOC:1017,63106,1014,114800,100,88,99,78 07471 12/12/2025 22:12:58 Discharge level 002 AH, SOC: 97%, I:102A, L:3817, l:3955, H:3864, B:047, PT:018C, BT:021C, PV:107574, M:Bike On 07472 12/12/2025 22:12:58 SOC:2393,61550,2385,114800,98,84,97,141 07473 12/12/2025 22:13:58 Discharge level 003 AH, SOC: 94%, I: 70A, L:3883, l:4005, H:3917, B:034, PT:019C, BT:022C, PV:109261, M:Bike On 07474 12/12/2025 22:13:58 SOC:3952,59896,3946,114800,97,89,94,125 07475 12/12/2025 22:14:58 Discharge level 005 AH, SOC: 91%, I: 14A, L:3944, l:4023, H:3969, B:025, PT:020C, BT:021C, PV:110867, M:Bike On 07476 12/12/2025 22:14:58 SOC:5795,58340,5877,114800,95,90,91,80 07477 12/12/2025 22:15:58 Discharge level 008 AH, SOC: 86%, I:149A, L:3658, l:3891, H:3724, B:066, PT:021C, BT:022C, PV:103510, M:Bike On 07478 12/12/2025 22:15:58 SOC:8006,56859,8092,114800,93,77,86,244 07479 12/12/2025 22:16:58 Discharge level 010 AH, SOC: 81%, I:125A, L:3655, l:3890, H:3719, B:064, PT:022C, BT:021C, PV:103474, M:Bike On 07480 12/12/2025 22:16:58 SOC:10818,55408,10938,114800,91,76,81,258 07481 12/12/2025 22:17:58 Discharge level 013 AH, SOC: 77%, I: 2A, L:3828, l:3948, H:3863, B:035, PT:023C, BT:022C, PV:107853, M:Bike On 07482 12/12/2025 22:17:58 SOC:13093,54789,13226,114800,89,83,77,141 07483 12/12/2025 22:18:58 Discharge level 015 AH, SOC: 72%, I:242A, L:3471, l:3776, H:3572, B:101, PT:024C, BT:022C, PV: 99064, M:Bike On 07484 12/12/2025 22:18:58 SOC:15594,54474,15742,114800,87,65,72,364 07485 12/12/2025 22:19:58 Discharge level 018 AH, SOC: 67%, I:515A, L:3181, l:3625, H:3341, B:160, PT:026C, BT:023C, PV: 92049, M:Bike On 07486 12/12/2025 22:19:58 SOC:18361,54400,18527,114800,84,40,67,548 07487 12/12/2025 22:19:58 Discharge cutback 76% 07488 12/12/2025 22:19:58 658A 07489 12/12/2025 22:20:58 Discharge level 022 AH, SOC: 60%, I:210A, L:3452, l:3738, H:3559, B:107, PT:027C, BT:022C, PV: 98768, M:Bike On 07490 12/12/2025 22:20:58 SOC:21871,54285,22040,114800,81,60,60,371 07491 12/12/2025 22:20:58 Discharge cutback 84% 07492 12/12/2025 22:20:58 719A 07493 12/12/2025 22:21:58 Discharge level 025 AH, SOC: 54%, I:123A, L:3550, l:3750, H:3630, B:080, PT:029C, BT:023C, PV:101029, M:Bike On 07494 12/12/2025 22:21:58 SOC:25222,54535,25405,114800,78,62,54,288 07495 12/12/2025 22:21:58 Discharge cutback 81% 07496 12/12/2025 22:21:58 695A 07497 12/12/2025 22:22:58 Discharge level 028 AH, SOC: 49%, I:188A, L:3447, l:3685, H:3549, B:102, PT:030C, BT:023C, PV: 98600, M:Bike On 07498 12/12/2025 22:22:58 SOC:28504,55019,28693,114800,76,52,49,364 07499 12/12/2025 22:22:58 Discharge cutback 68% 07500 12/12/2025 22:22:58 584A 07501 12/12/2025 22:23:58 Discharge level 031 AH, SOC: 43%, I:233A, L:3394, l:3646, H:3505, B:111, PT:032C, BT:023C, PV: 97319, M:Bike On 07502 12/12/2025 22:23:58 SOC:31741,55649,31933,114800,73,46,43,407 07503 12/12/2025 22:23:58 Discharge cutback 62% 07504 12/12/2025 22:23:58 536A 07505 12/12/2025 22:24:58 Discharge level 035 AH, SOC: 37%, I:318A, L:3307, l:3586, H:3437, B:130, PT:033C, BT:024C, PV: 95294, M:Bike On 07506 12/12/2025 22:24:58 SOC:35524,55872,35718,114800,69,32,37,469 07507 12/12/2025 22:24:58 Discharge cutback 60% 07508 12/12/2025 22:24:58 516A 07509 12/12/2025 22:25:58 Discharge level 039 AH, SOC: 31%, I:184A, L:3381, l:3603, H:3487, B:106, PT:035C, BT:024C, PV: 96906, M:Bike On 07510 12/12/2025 22:25:58 SOC:39207,56442,39403,114800,66,38,31,384 07511 12/12/2025 22:25:58 Discharge cutback 56% 07512 12/12/2025 22:25:58 482A 07513 12/12/2025 22:26:58 Discharge level 042 AH, SOC: 26%, I:376A, L:3251, l:3520, H:3388, B:137, PT:036C, BT:024C, PV: 93869, M:Bike On 07514 12/12/2025 22:26:58 SOC:42572,57484,42783,114800,63,17,26,486 07515 12/12/2025 22:26:58 Discharge cutback 53% 07516 12/12/2025 22:26:58 455A 07517 12/12/2025 22:27:58 Discharge level 046 AH, SOC: 22%, I:153A, L:3400, l:3590, H:3489, B:089, PT:037C, BT:025C, PV: 97100, M:Bike On 07518 12/12/2025 22:27:58 SOC:46012,58783,46226,114800,60,36,22,344 07519 12/12/2025 22:27:58 Discharge cutback 54% 07520 12/12/2025 22:27:58 462A 07521 12/12/2025 22:28:58 Discharge level 049 AH, SOC: 21%, I:190A, L:3368, l:3560, H:3464, B:096, PT:038C, BT:025C, PV: 96344, M:Bike On 07522 12/12/2025 22:28:58 SOC:48796,61009,49012,114800,58,30,21,353 07523 12/12/2025 22:28:58 Discharge cutback 55% 07524 12/12/2025 22:28:58 472A 07525 12/12/2025 22:29:58 Discharge level 052 AH, SOC: 18%, I:228A, L:3326, l:3535, H:3434, B:108, PT:039C, BT:025C, PV: 95442, M:Bike On 07526 12/12/2025 22:29:58 SOC:51857,62697,52078,114800,55,22,18,378 07527 12/12/2025 22:29:58 Discharge cutback 51% 07528 12/12/2025 22:29:58 438A 07529 12/12/2025 22:30:58 Discharge level 053 AH, SOC: 19%, I: 27A, L:3522, l:3616, H:3568, B:046, PT:039C, BT:025C, PV: 99611, M:Bike On 07530 12/12/2025 22:30:58 SOC:52552,64402,53477,114800,54,43,19,173 07531 12/12/2025 22:30:58 Discharge cutback 62% 07532 12/12/2025 22:30:58 533A 07533 12/12/2025 22:31:58 Discharge level 054 AH, SOC: 22%, I:132A, L:3475, l:3579, H:3539, B:064, PT:039C, BT:026C, PV: 98653, M:Bike On 07534 12/12/2025 22:31:58 SOC:52447,66830,54022,114800,53,36,22,200 07535 12/12/2025 22:31:58 Discharge cutback 70% 07536 12/12/2025 22:31:58 601A 07537 12/12/2025 22:32:58 Discharge level 054 AH, SOC: 24%, I: 0A, L:3568, l:3620, H:3603, B:035, PT:039C, BT:027C, PV:100675, M:Bike On 07538 12/12/2025 22:32:58 SOC:52629,68661,54860,114800,53,45,24,101 07539 12/12/2025 22:32:58 Discharge cutback 71% 07540 12/12/2025 22:32:58 607A 07541 12/12/2025 22:33:58 Discharge level 055 AH, SOC: 26%, I: -5A, L:3590, l:3625, H:3617, B:027, PT:039C, BT:026C, PV:101132, M:Bike On 07542 12/12/2025 22:33:58 SOC:51919,69564,55221,114800,52,46,26,69 07543 12/12/2025 22:33:58 Discharge cutback 74% 07544 12/12/2025 22:33:58 638A 07545 12/12/2025 22:34:58 Discharge level 055 AH, SOC: 28%, I: 0A, L:3596, l:3624, H:3622, B:026, PT:039C, BT:027C, PV:101261, M:Bike On 07546 12/12/2025 22:34:58 SOC:51076,70178,55437,114800,52,45,28,56 07547 12/12/2025 22:34:58 Discharge cutback 77% 07548 12/12/2025 22:34:58 665A 07549 12/12/2025 22:35:58 Discharge level 055 AH, SOC: 30%, I: 0A, L:3605, l:3626, H:3629, B:024, PT:039C, BT:027C, PV:101471, M:Bike On 07550 12/12/2025 22:35:58 SOC:49926,70429,55441,114800,52,46,30,42 07551 12/12/2025 22:35:58 Discharge cutback 80% 07552 12/12/2025 22:35:58 688A 07553 12/12/2025 22:36:58 Discharge level 055 AH, SOC: 31%, I: 0A, L:3612, l:3627, H:3632, B:020, PT:039C, BT:027C, PV:101596, M:Bike On 07554 12/12/2025 22:36:58 SOC:48796,70429,55441,114800,52,46,31,31 07555 12/12/2025 22:36:58 Discharge cutback 82% 07556 12/12/2025 22:36:59 702A 07557 12/12/2025 22:37:58 Discharge level 055 AH, SOC: 33%, I: 0A, L:3616, l:3627, H:3635, B:019, PT:039C, BT:027C, PV:101674, M:Bike On 07558 12/12/2025 22:37:58 SOC:47773,70429,55441,114800,52,46,33,22 07559 12/12/2025 22:37:58 Discharge cutback 82% 07560 12/12/2025 22:37:59 709A 07561 12/12/2025 22:38:58 Discharge level 055 AH, SOC: 34%, I: 0A, L:3619, l:3627, H:3637, B:018, PT:039C, BT:027C, PV:101732, M:Bike On 07562 12/12/2025 22:38:58 SOC:46847,70429,55441,114800,52,46,34,17 07563 12/12/2025 22:38:58 Discharge cutback 83% 07564 12/12/2025 22:38:59 715A 07565 12/12/2025 22:39:58 Discharge level 055 AH, SOC: 35%, I: 0A, L:3621, l:3627, H:3639, B:018, PT:039C, BT:028C, PV:101777, M:Bike On 07566 12/12/2025 22:39:58 SOC:46009,70429,55441,114800,52,46,35,13 07567 12/12/2025 22:39:58 Discharge cutback 84% 07568 12/12/2025 22:39:59 719A 07569 12/12/2025 22:40:58 Discharge level 055 AH, SOC: 36%, I: 0A, L:3622, l:3627, H:3640, B:018, PT:039C, BT:029C, PV:101811, M:Bike On 07570 12/12/2025 22:40:58 SOC:45251,70429,55441,114800,52,46,36,10 07571 12/12/2025 22:40:59 Discharge cutback 84% 07572 12/12/2025 22:40:59 722A 07573 12/12/2025 22:41:58 Discharge level 055 AH, SOC: 37%, I: 0A, L:3624, l:3628, H:3641, B:017, PT:039C, BT:028C, PV:101840, M:Bike On 07574 12/12/2025 22:41:58 SOC:44564,70429,55441,114800,52,46,37,8 07575 12/12/2025 22:41:59 Discharge cutback 84% 07576 12/12/2025 22:41:59 725A 07577 12/12/2025 22:42:58 Discharge level 055 AH, SOC: 38%, I: 0A, L:3624, l:3627, H:3642, B:018, PT:039C, BT:029C, PV:101864, M:Bike On 07578 12/12/2025 22:42:59 SOC:43943,70429,55441,114800,52,46,38,6 07579 12/12/2025 22:42:59 Discharge cutback 84% 07580 12/12/2025 22:42:59 725A 07581 12/12/2025 22:43:58 Discharge level 055 AH, SOC: 39%, I: 0A, L:3626, l:3628, H:3643, B:017, PT:039C, BT:029C, PV:101886, M:Bike On 07582 12/12/2025 22:43:59 SOC:43381,70429,55441,114800,52,46,39,5 07583 12/12/2025 22:43:59 Discharge cutback 85% 07584 12/12/2025 22:43:59 729A 07585 12/12/2025 22:44:58 Discharge level 055 AH, SOC: 40%, I: 0A, L:3626, l:3628, H:3643, B:017, PT:039C, BT:029C, PV:101903, M:Bike On 07586 12/12/2025 22:44:59 SOC:42872,70429,55441,114800,52,46,40,4 07587 12/12/2025 22:44:59 Discharge cutback 85% 07588 12/12/2025 22:44:59 729A 07589 12/12/2025 22:45:59 Discharge level 055 AH, SOC: 40%, I: 0A, L:3627, l:3629, H:3644, B:017, PT:039C, BT:030C, PV:101921, M:Bike On 07590 12/12/2025 22:45:59 SOC:42411,70429,55441,114800,52,46,40,4 07591 12/12/2025 22:45:59 Discharge cutback 85% 07592 12/12/2025 22:45:59 732A 07593 12/12/2025 22:46:59 Discharge level 055 AH, SOC: 41%, I: 0A, L:3628, l:3629, H:3644, B:016, PT:038C, BT:030C, PV:101928, M:Bike On 07594 12/12/2025 22:46:59 SOC:41993,70429,55441,114800,52,46,41,3 07595 12/12/2025 22:46:59 Discharge cutback 85% 07596 12/12/2025 22:46:59 732A 07597 12/12/2025 22:47:59 Discharge level 055 AH, SOC: 41%, I: 0A, L:3629, l:3630, H:3644, B:015, PT:038C, BT:030C, PV:101943, M:Bike On 07598 12/12/2025 22:47:59 SOC:41592,70429,55441,114800,52,47,41,3 07599 12/12/2025 22:47:59 Discharge cutback 85% 07600 12/12/2025 22:47:59 732A 07601 12/12/2025 22:48:59 Discharge level 055 AH, SOC: 42%, I: 0A, L:3629, l:3630, H:3645, B:016, PT:038C, BT:031C, PV:101952, M:Bike On 07602 12/12/2025 22:48:59 SOC:41235,70429,55441,114800,52,46,42,2 07603 12/12/2025 22:48:59 Discharge cutback 85% 07604 12/12/2025 22:48:59 736A 07605 12/12/2025 22:49:59 Discharge level 055 AH, SOC: 42%, I: 0A, L:3630, l:3631, H:3645, B:015, PT:038C, BT:030C, PV:101963, M:Bike On 07606 12/12/2025 22:49:59 SOC:40917,70429,55441,114800,52,47,42,2 07607 12/12/2025 22:49:59 Discharge cutback 85% 07608 12/12/2025 22:49:59 736A 07609 12/12/2025 22:50:59 Discharge level 055 AH, SOC: 43%, I: 0A, L:3630, l:3631, H:3645, B:015, PT:038C, BT:031C, PV:101967, M:Bike On 07610 12/12/2025 22:50:59 SOC:40591,70429,55441,114800,52,47,43,2 07611 12/12/2025 22:50:59 Discharge cutback 85% 07612 12/12/2025 22:50:59 736A 07613 12/12/2025 22:51:26 DEBUG: Entered Charging State 07614 12/12/2025 22:51:26 DEBUG: CAN NOT Receiving Syncs 07615 12/12/2025 22:51:27 Discharge level 055 AH, SOC: 43%, I: 0A, L:3631, l:3632, H:3645, B:014, PT:038C, BT:031C, PV:101976, M:Charge 07616 12/12/2025 22:51:27 SOC:40447,70429,55441,114800,52,47,43,2 07617 12/12/2025 22:51:27 DEBUG: CAN Receiving Syncs 07618 12/12/2025 23:01:27 Discharge level 053 AH, SOC: 49%, I:-11A, L:3662, l:3651, H:3673, B:011, PT:037C, BT:033C, PV:102786, M:Charge 07619 12/12/2025 23:01:27 SOC:33632,65619,53482,114800,54,50,49,-22 07620 11/26/2025 14:37:32 SOC:32185,53733,40372,114800,65,50,41,200 07621 11/26/2025 14:37:32 Discharge cutback 58% 07622 11/26/2025 14:37:32 Discharge cutback 58% 07623 11/26/2025 14:37:32 Discharge cutback 58% 07624 11/26/2025 14:37:32 499A 07625 11/26/2025 14:38:32 Discharge level 042 AH, SOC: 38%, I: 97A, L:3496, l:3627, H:3571, B:075, PT:032C, BT:024C, PV: 99489, M:Bike On 07626 11/26/2025 14:38:32 SOC:34115,54316,42341,114800,64,45,38,205 07627 11/26/2025 14:38:32 Discharge cutback 69% 07628 11/26/2025 14:38:32 597A 07629 11/26/2025 14:39:32 Discharge level 044 AH, SOC: 34%, I:158A, L:3407, l:3576, H:3508, B:101, PT:032C, BT:025C, PV: 97550, M:Bike On 07630 11/26/2025 14:39:32 SOC:36256,54725,44483,114800,62,31,34,262 07631 11/26/2025 14:39:32 Discharge cutback 64% 07632 11/26/2025 14:39:32 550A 07633 11/26/2025 14:40:32 Discharge level 046 AH, SOC: 31%, I:104A, L:3469, l:3607, H:3545, B:076, PT:032C, BT:024C, PV: 98759, M:Bike On 07634 11/26/2025 14:40:32 SOC:38273,55336,46503,114800,60,39,31,212 07635 11/26/2025 14:40:32 Discharge cutback 64% 07636 11/26/2025 14:40:32 550A 07637 11/26/2025 14:41:32 Discharge level 047 AH, SOC: 31%, I:129A, L:3463, l:3586, H:3541, B:078, PT:032C, BT:025C, PV: 98638, M:Bike On 07638 11/26/2025 14:41:32 SOC:39330,56910,47640,114800,59,36,31,196 07639 11/26/2025 14:41:32 Discharge cutback 69% 07640 11/26/2025 14:41:32 597A 07641 11/26/2025 14:42:32 Discharge level 049 AH, SOC: 29%, I:128A, L:3423, l:3565, H:3510, B:087, PT:032C, BT:024C, PV: 97686, M:Bike On 07642 11/26/2025 14:42:32 SOC:41325,57522,49636,114800,57,30,29,225 07643 11/26/2025 14:42:32 Discharge cutback 60% 07644 11/26/2025 14:42:32 513A 07645 11/26/2025 14:43:32 Discharge level 051 AH, SOC: 26%, I: 76A, L:3476, l:3592, H:3543, B:067, PT:033C, BT:025C, PV: 98770, M:Bike On 07646 11/26/2025 14:43:32 SOC:43182,58096,51500,114800,56,36,26,180 07647 11/26/2025 14:43:32 Discharge cutback 60% 07648 11/26/2025 14:43:32 519A 07649 11/26/2025 14:44:32 Discharge level 053 AH, SOC: 24%, I: 1A, L:3547, l:3627, H:3587, B:040, PT:033C, BT:023C, PV:100199, M:Bike On 07650 11/26/2025 14:44:32 SOC:44803,58845,53150,114800,54,44,24,123 07651 11/26/2025 14:44:32 Discharge cutback 61% 07652 11/26/2025 14:44:32 523A